Transition Networks CGETF1013-100, CGETF1014-100, CGETF1015-100, CGETF1017-100, CGETF1018-100 User Manual

...
COMPLIANCE INFORMATION
UL Listed C-UL Listed (Canada) CISPR/EN55022 Class A EN55024
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les measures spécifiques appropriées
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners.
Copyright Restrictions
© 2001 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Printed in the U.S.A. 33198.C
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
TRANSITION Networks CGETF10xx series Gigabit Ethernet™media converters,
designed to be installed in a PointSystem
Conversion Center
, connect
1000BASE-TX shielded or unshielded twisted-pair copper cable to 1000BASE-SX or 1000BASE-LX multimode or singlemode fiber-optic cable.
1000BASE-TX to 1000BASE-SX/LX
Slide-In-Module Media Converters
CGETF10xx-100
USER’S GUIDE
CGETF1013-100
Provides an RJ-45 twisted-pair copper 1000BASE-T connector and an RX (receive) and TX (transmit) SC connector to 850 nm 1000BASE-SX multimode fiber-optic cable.
CGETF1014-100
Provides an RJ-45 twisted-pair copper 1000BASE-T connector and an RX (receive) and TX (transmit) SC connector to 1300 nm 1000BASE-LX singlemode fiber-optic cable.
CGETF1015-100
Provides an RJ-45 twisted-pair copper 1000BASE-T connector and an RX (receive) and TX (transmit) SC connector to 1300 nm 1000BASE-LX singlemode fiber-optic cable.
CGETF1017-100
Provides an RJ-45 twisted-pair copper 1000BASE-T connector and an RX (receive) and TX (transmit) SC connector to 1550 nm 1000BASE-LX singlemode fiber-optic cable.
CGETF1018-100
Provides an RJ-45 twisted-pair copper 1000BASE-T connector and an RX (receive) and TX (transmit) MT-RJ connector to 850 nm 1000BASE-SX multimode fiber-optic cable.
CGETF1025-100
Provides an RJ-45 twisted-pair copper 1000BASE-T connector and an RX (receive) and TX (transmit) MT-RJ connector to 1300 nm 1000BASE-LX singlemode fiber-optic cable.
CFMFF100
CFMFF100
CFMFF100
CFMFF100
CETCF100
CETCF100
CFETF110
0
SPD
PWR
FRX
CRX
FLNK
CLNK
10/100TX
RX
TX
10/100SX
Link
Link
Alert
Alert
E
D
0
50
50
LA
PWR
PWR
RXF
RXC
LNK
LNK
COL
COL
10BASE-2
10BASE-FL
LKS
LKS
PWR
PWR
LKM
LKM
LKS
LKS
PWR
PWR
LKM
LKM
Multimode
Multimode
Singlemode
Singlemode
TX
TX
RX
RX
TX
TX
RX
RX
Multimode
Multimode
Singlemode
Singlemode
TX
TX
RX
RX
TX
TX
RX
RX
CGETF10xx in the Network . . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . . . .4
Fault Isolation and Correction . . . . .5
Cable Specifications . . . . . . . . . . . . .6
Technical Specifications . . . . . . . . . .7
Compliance Information . . . . . . . . . .8
CGETF10xx IN THE NETWORK
Install two CGETF10xx series media converters in series to extend, over fiber, the distance between two 1000BASE-TX devices. Or use one CGETF10xx media converter to connect a 1000BASE-TX terminal device and a 1000BASE-SX/LX hub, switch, or router. Or use one CGETF10xx media converter to connect a 1000BASE-TX hub, switch, or router and a 1000BASE-SX/LX terminal device.
NOTE: A TRANSITION Networks stand-alone media converter can be installed in series with a TRANSITION Networks chassis media converter that has a related model number, such as an SGETF10xx with a CGETF10xx.
INSTALLATION
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when setting switch and when installing Slide-in-Module in the Media Conversion Center. Failure to observe this caution could result in damage to, and subsequent failure of, the Media Converter Slide-in-Module.
Set 3-Position Jumper
NOTE: Jumper is located on Media Converter Slide-in-Module circuit board. Use small needle-nosed pliers or similar device to set
jumper. Refer to drawing for jumper positions. HARDWARE Converter mode is determined by 4-position
switch settings below. SOFTWARE Converter mode is determined by most-
recently-saved on-board microprocessor settings.
Set 4-Position Switch
NOTE: Switch is located on Media Converter Slide-in-Module circuit board. Use small flatblade screwdriver or
similar device to set recessed switches. Refer to drawing for four-position switch locations.
Full/Half-Duplex Advertisement (UP=Enabled) Allows full-duplex
mode. (DOWN) Allows half­duplex mode.
Pause Advertisement (UP=Enabled) Allows auto-negotiation pause. (DOWN) Allows NO auto-negotiation pause.
NOTE: If the Pause feature is present on all network devices attached to the media converter(s), enable Pause on the media converter(s). Otherwise, disable Pause on the media converter(s).
LPT (UP=Enabled) Allows a fault EITHER on the copper OR on the fiber side of the media coverter to stop signal and data transmission on the other side. (DOWN) Disables LPT.
CATEGORY 5:
Gauge 24 to 22 AWG Attenuation 22.0 dB /100m @ 100 MHz Maximum Cable Distance: 100 meters
The Gigabit Ethernet™ network uses all four wire pairs. The active pairs are pins 1 & 2, pins 3 & 6, pins 4 & 5, and pins 7 & 8. Use only
dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins.
NOTE: Straight-through/crossover configuration is automatic.
TECHNICAL SPECIFICATIONS
Standards IEEE 802.3ab, IEEE 802.3 1998 Data Rate 1000 Mb/s
Dimensions 3.4" x 0.86" x 5.0" (86mm x 22mm x 127mm) Weight 8 oz (approximate) Delay 300 nsec Power Consumption 6.5 Watts Environment Typical Operating Temperature*: 0-50°C (32°to 122°F )
Storage Temperature: -20 to 85°C Humidity 10-90%, non condensing Altitude 0-10,000 feet
Warranty Lifetime *Operating temperature range for this Slide-In-Module depends on the physical
characteristics and the installation configuration of the TRANSITION Networks chassis in which this Slide-In-Module will be installed. See the User’s Guide for the chassis in which this Slide-In-Module will be installed for a discussion of temperature-related installation constraints.
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA Model: CGETF10xx-100 Series Media Converters Part Number(s): CGETF1013-100, CGETF1014-100, CGETF1015-100,
CGETF1017-100, CGETF1018-100, CGETF1023-100
Regulation: EMC Directive 89/336/EEC Purpose: To declare that the CGETF10xx-100to which this declaration refers is
in conformity with the following standards.
EMC-CISPR 22: 1985 Class A&B; EN 55022:1988 Class A&B; EN 50082-1:1992; EN 60950 A4:1997; IEC 801.2, IEC 801.3, and IEC 801.4; IEC 950
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
_January 6, 2001_____
Stephen Anderson, Vice-President of Engineering Date
SOFTWARE MODE
H
S
HARDWARE MODE
H
S
toward network connectors toward chassis
Not Used
LPT UP=ON
Pause Advertisement UP=ON
Full/Half-Duplex Advertisement UP=ON
CABLE SPECIFICATIONS
The physical characteristics of the media cable must meet or exceed IEEE 802.3 specifications.
Fiber Cable
Bit error rate: 10-9
MULTIMODE
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber
Optional: 100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber CGETF1013 850 nM Fiber Optic Transmitter Power: min: -10.0 dBm max: -4.0 dBm Fiber Optic Receiver Sensitivity: min: -17.0 dBm max: -0.0 dBm Link Budget: 7.0 dB Typical Maximum Cable Distance*: 220 meters CGETF1018 850 nM Fiber Optic Transmitter Power: min: -9.5 dBm max: -4.0 dBm Fiber Optic Receiver Sensitivity: min: -17.0 dBm max: -0.0 dBm Link Budget: 7.0 dB Typical Maximum Cable Distance*: 220 meters
SINGLEMODE
Fiber Optic Cable Recommended: 9 µm singlemode fiber CGETF1014 1300 nM Fiber-optic Transmitter Power: min: -13.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -20.0 dBm max: -3.0 dBm Link Budget: 7.0 dB Typical Maximum Cable Distance*: 10 kilometers CGETF1015 1300 nM Fiber-optic Transmitter Power: min: -5.0 dBm max: -0.0 dBm Fiber-optic Receiver Sensitivity: min: -20.0 dBm max: -3.0 dBm Link Budget: 15.0 dB Typical Maximum Cable Distance*: 25 kilometers CGETF1017 1550 nM Fiber-optic Transmitter Power: min: -3.0 dBm max: -2.0 dBm Fiber-optic Receiver Sensitivity: min: -23.0 dBm max: -3.0 dBm Link Budget: 20.0 dB Typical Maximum Cable Distance*: 65 kilometers CGETF1025 1550 nM Fiber-optic Transmitter Power: min: -9.5 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -20.0 dBm max: -3.0 dBm Link Budget: 20.0 dB Typical Maximum Cable Distance*: 65 kilometers
*Actual distance dependent upon physical characteristics of network installation.
Copper Cable
Category 5 twisted-pair copper wire is required. Either shielded twisted-pair (STP) or unshielded twisted-pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.
Install Slide-In-Module in PointSystem™Chassis
CAUTION: Any Slide-in-Module installation slot in which a Media Converter Slide-in-Module is NOT installed MUST have a protective plate instead. Failure to observe this caution will void Class A and/or Class B compliance.
NOTE: Install Media Converter Slide-in-Modules in any slot, in any order.
1. Carefully slide Media Converter Slide-in-Module into installation slot, aligning Media Converter Slide-in-Module with installation guides.
NOTE: Ensure that Slide-in-Module is firmly seated against backplane.
2. Secure Slide-in-Module by securing panel fastener screw (attached to Slide-in-Module) to chassis front.
3. Install protective plate at ANY Slide-in-Module installation slot in which a Media Converter Slide-in-Module is not installed by securing attached protective plate panel fastener screw to chassis front.
Install Cable
COPPER
NOTE: The CGETF10xx series media converter auto-negotiation feature allows the media converter to bring up the copper link in the highest mode possible for ALL the attached network devices.
1. Locate or build 1000BASE-TX-compliant cables with male RJ-45
connectors installed at both ends.
2. Connect RJ-45 connector at one end of cable to media converter
RJ-45 port connector.
3. Connect RJ-45 connector at other end of cable to 1000BASE-TX-
compliant device RJ-45 port connector.
FIBER
1. Locate or build 1000BASE-SX/LX-compliant fiber cable with male
two-stranded TX to RX connectors installed at both ends.
2. Connect cable with connector installed at TX location on media
converter to RX location on attached device.
3. Connect cable with connector installed at RX location on media
converter to TX location on attached device.
Power the Slide-In-Module
NOTE: The Slide-In-Module is powered through the Conversion
Center
.
TX
RX
TX
RX
OPERATION
Using Status LEDs
Use the status LEDs to monitor media converter operation in the network. P(o)W(e)R Steady LED indicates connection to
external AC power.
RXF (Fiber receive) Flashing LED indicates
reception of data on fiber link.
LKF (Fiber link) Steady LED indicates fiber
link connection.
RXC (Copper receive) Flashing LED indicates reception of data on
copper link.
LKC (Copper link) Steady LED indicates copper link connection.
Using SNMP*
Use SNMP at an attached terminal or at a remote location to:
Monitor media converter by monitoring:
Media Converter Power Copper Link Status Copper Receive Status Twisted-pair Copper Cable Length Fiber Link Status Fiber Receive Status Master/Slave Status Hardware Switch settings Fault Conditiion Receive Error Count
Enter network commands that:
Enable/disable Full/Half-duplex Advertisement Enable/disable LPT Enable/disable Pause
*See the on-line documentation that comes with TRANSITION Networks
FocalPoint
software for applicable commands and usage.
FAULT ISOLATION and CORRECTION
If the media converter fails, isolate and correct the fault by determining the answers to the following questions and then taking the indicated action:
1. Is the P(o)W(e)RLED on the media converter illuminated? NO
Is the media converter inserted properly into the chassis?
Is the power cord properly installed in the chassis and at the
external power source?
Does the external power source provide power?
Contact Technical Support: (800) 260-1312.
YES
Proceed to step 2.
2. Is the LKCLED on the media converter illuminated? NO
Check twisted-pair cables for proper connection.
Check twisted-pair cables for connection of all four pairs.
Contact Technical Support: (800) 260-1312.
YES
Proceed to step 3.
3. Is the LKFLED on the media converter illuminated? NO
Check fiber cables for proper connection.
Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other device.
Contact Technical Support: (800) 260-1312.
YES
Proceed to step 4.
4. Is the RXCLED on the media converter flashing? NO
If there is NO ACTIVITY on the 1000BASE-TX port, proceed to step 5.
If there is ACTIVITY on the 1000BASE-TX port, disconnect and
reconnect the 1000BASE-TX cable to restart the initialization process.
Restart the workstation to restart the initialization process.
Contact Technical Support: (800) 260-1312.
YES
Proceed to step 5.
5. Is the RXF LED on the media converter flashing? NO
If there is NO ACTIVITY on the 1000BASE-SX/LX port, continue
below
If there is ACTIVITY on the 1000BASE-SX/LX port, disconnect and
reconnect the fiber cable to restart the initialization process.
Restart the workstation to restart the initialization process.
Contact Technical Support: (800) 260-1312.
YES
Contact Technical Support: (800) 260-1312.
PWR
RXF
RXC
LKF
LKC