Transition Networks CFMFF1316-210, CFMFF1329-211, CFMFF1317-210, CFMFF1329-210, CFMFF1329-212 User Manual

...
CFMFF1717-210 SC, 1550 nm singlemode
60 km (37.2 miles)
SC, 1550 nm singlemode 60 km (37.2 miles)
CFMFFxxxx-2xx User’s Guide
• Slide-in-Module Media Converter
• Fast Ethernet, ATM, SONET, or Gigabit
Transition Networks CFMFFxxxx-2xx series media converters extend multimode and singlemode interfaces to singlemode fiber optic cable over Fast Ethernet, ATM, SONET, and Gigabit networks. The CFMFFxxxx-2xx is also designed to install into the Transition Networks PointSystem™ chassis.
622 Mb/s cable speed:
The models with the -21x extension are for cable speeds of 622 Mb/s and extend ATM or SONET over singlemode fiber up to 60 km.
Part Number Port One - Fiber-Optic Port Two - Fiber-Optic
CFMFF1314-210 SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1310 nm singlemode 15 km (9.3 miles)
CFMFF1316-210 SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1310 nm singlemode 40 km (24.8 miles)
CFMFF1317-210 SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1550 nm singlemode 60 km (37.2 miles)
CFMFF1329-210 SC, 1300 nm multimode
duplex, 2 km (1.2 miles)
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1329-211 SC, 1300 nm multimode
duplex, 2 km (1.2 miles)
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1329-212 SC, 1300 nm multimode
duplex, 2 km (1.2 miles)
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 40 km (24.8 mi)
CFMFF1329-213 SC, 1300 nm multimode
duplex, 2 km (1.2 miles)
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 40 km (24.8 mi)
CFMFF1429-210 SC, 1310 nm singlemode
duplex, 15 km (9.3 miles)
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1429-211 SC, 1310 nm singlemode
duplex, 15 km (9.3 miles)
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1429-212 SC, 1310 nm singlemode
duplex, 15 km (9.3 miles)
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 40 km (24.8 mi)
CFMFF1429-213 SC, 1310 nm singlemode
duplex, 15 km (9.3 miles)
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 40 km (24.8 mi)
Installation . . . . . . . . . . . . . . . . . .4
Operation . . . . . . . . . . . . . . . . . . .6
Cable Specifications . . . . . . . . . . .7
Technical Specifications . . . . . . .13
Troubleshooting . . . . . . . . . . . . .14
Compliance Information . . . . . . .16
2
CFMFFxxxx-2xx
24-hour Technical Support: 1-800-260-1312 – International: 00-1-952-941-7600
155 Mb/s cable speed:
The models with the -20x extension are for cable speeds of 155 Mb/s and extend ATM or Fast Ethernet over singlemode fiber up to 80 km.
CFMFF1329-202 SC, 1300 nm multimode
duplex, 2 km (1.2 miles)
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 40 km (24.8 mi)
CFMFF1329-203 SC, 1300 nm multimode
duplex, 2 km (1.2 miles)
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 40 km (24.8 mi)
CFMFF1429-200 SC, 1310 nm singlemode
duplex, 20 km (12.4 miles)
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1429-201 SC, 1310 nm singlemode
duplex, 20 km (12.4 miles)
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1429-202 SC, 1310 nm singlemode
duplex, 20 km (12.4 miles)
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 40 km (24.8 mi)
CFMFF1429-203 SC, 1310 nm singlemode
duplex, 20 km (12.4 miles)
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 40 km (24.8 mi)
Part Number Port One - Fiber-Optic Port Two - Fiber-Optic
CFMFF1314-200 SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1310 nm singlemode 20 km (12.4 miles)
CFMFF1313-200 SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1300 nm multimode 2 km (1.2 miles)
CFMFF1315-200 SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1310 nm singlemode 40 km (24.8 miles)
CFMFF1316-200 SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1310 nm singlemode 60 km (37.2 miles)
CFMFF1317-200 SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1550 nm singlemode 80 km (49.7 miles)
CFMFF1329-200 SC, 1300 nm multimode
duplex, 2 km (1.2 miles)
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1329-201 SC, 1300 nm multimode
duplex, 2 km (1.2 miles)
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 20 km (12.4 mi)
The cable distances listed are typically maximum. The actual maximum cable distances are dependent upon the physical characteristics of the network installation.
SM = singlemode, TX = transmit, RX = receive.
CFMFF1414-200 SC, 1310 nm singlemode
duplex, 20 km (12.4 miles)
SC, 1310 nm singlemode duplex, 20 km (12.4 miles)
CFMFF1415-200 SC, 1310 nm singlemode
duplex, 20 km (12.4 miles)
SC, 1310 nm singlemode 40 km (24.8 miles)
1.25 Gb/s cable speed:
The models with the -22x extensions are for cable speeds of 1.2Gb/s and can extend gigabit Ethernet over a singlemode fiber up to 125 km.
3
techsupport@transition.com – Click the “Transition Now” link for a live Web chat.
Part Number Port One – Fiber Optic
Port Two – Fiber-Optic
CFMFF1314-220 SC, 850 nm multimode
220 m (721 ft)**
SC, 1310 nm singlemode 10 km (6.2 miles)
CFMFF1315-220 SC, 850 nm multimode
220 m (721 ft)**
SC, 1310 nm singlemode 25 km (15.5 miles)
CFMFF1317-220 SC, 850 nm multimode
220 m (721 ft)**
SC, 1550 nm singlemode 65 km (40.3 miles)
CFMFF1324-220 SC, 850 nm multimode
220 m (721 ft)**
SC, 1300 nm extended MM up to 2 km (1.2 miles)
(62.5/125 mm fiber only)
CFMFF1335-220 SC, 850 nm multimode
220 m (721 ft)**
SC, 1550 nm singlemode 125 km (77.5 mi)
CFMFF1414-220 SC, 1310 nm singlemode
10 km (6.2 miles)
SC, 1310 nm singlemode 10 km (6.2 miles)
CFMFF1424-220 SC, 1310 nm singlemode
10 km (6.2 miles)
SM = singlemode, MM = multimode, TX = transmit, RX = receive.
Unless otherwise indicated, the distances listed are the typical maximum cable distance. The actual maximum cable distances are dependent upon the physical characteristics of the network installation.
** Minimum cable distance: 2 meters
Typical maximum cable distance: 220 meters for 160/500MHz•Km
270 meters for 200/500MHz•Km
CFMFF1313-220 SC, 850 nm multimode
220 m (721 ft)**
SC, 850 nm multimode 220 m (721 ft)**
CFMFF1429-220
SC, 1310 nm singlemode 10 km (6.2 miles)
SC, 1300 nm extended MM up to 2 km (1.2 miles)
(62.5/125 mm fiber only)
CFMFF1825-220 MJ-RJ, 850 nm multimode
220 m (721 ft)
MJ-RJ, 1310 nm singlemode 10 km (6.2 miles)
CFMFF1329-220 SC, 850 nm duplex MM
220 m (721 ft)**
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1329-221 SC, 850 nm duplex MM
220 m (721 ft)**
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1329-222 SC, 850 nm multimode
220 m (721 ft)**
SC, 1310 nm (TX)/1550 nm (RX) SM SF, 40 km (24.9 miles)
CFMFF1329-223 SC, 850 nm multimode
220 m (721 ft)**
SC, 1310 nm (TX)/1550 nm (RX) SM SF, 40 km (24.9 miles)
SC, 1310 nm (TX)1550 nm (RX) SM single fiber, 20 km (12.4 mi)
4
CFMFFxxxx-2xx
24-hour Technical Support: 1-800-260-1312 – International: 00-1-952-941-7600
Installation
Install these Models in Pairs
The following media converter pairs are to be installed in the same network, where one serves as the local converter and the other a remote converter (either converter can be installed in either location).
155 Mb/s network:
• CFMFF1329-200 and CFMFF1329-201
• CFMFF1329-202 and CFMFF1329-203
• CFMFF1429-200 and CFMFF1429-201
• CFMFF1429-202 and CFMFF1429-203
622 Mb/s network:
• CFMFF1329-210 and CFMFF1329-211
• CFMFF1329-212 and CFMFF1329-213
• CFMFF1429-210 and CFMFF1429-211
• CFMFF1429-212 and CFMFF1429-213
1.2 GB/s network:
• CFMFF1329-220 and CFMFF1329-221
• CFMFF1329-222 and CFMFF1329-223
Install Slide-in-module in PointSystem™ chassis
CAUTION: Slots in the PointSystem™ chassis without a slide-in-module MUST have a protective plate covering the empty slot for Class B compliance.
The media converter slide-in-modules may be installed in any slot, in any order.
To install the slide-in-module:
1. Carefully slide the slide-in-module into the slot, aligning the module’s circuit board with the slot guides.
2. Ensure that the module is firmly seated in the chassis slot.
3. Secure the module by pushing its fastern in and turning it clockwise.
5
techsupport@transition.com – Click the “Transition Now” link for a live Web chat.
Installation – Continued
Install the fiber cable
CAUTION: Both connections (Port 1 and Port 2) to the CFMFFxxxx-2xx media converter must be the same network speed and network protocol. Failure to observe this caution could cause data transfers to fail.
1. Locate or build IEEE 802.3™ compliant fiber cable with male, two­stranded TX to RX connectors installed at both ends.
2. Connect the fiber cables to the CFMFFxxxx-2xx media converter as described:
• Connect the male TX cable connector to the female TX port.
• Connect the male RX cable connector to the female RX port.
3. Connect the fiber cables to the other device (another media converter, hub, etc.) as described:
• Connect the male TX cable connector to the female RX port.
• Connect the male RX cable connector to the female TX port.
Power the Media Converter
The media converter is powered through the Transition Networks PointSystem™ chassis.
Delay Times
Network worst-case delay through the CFMFFxxxx-2xx converter: 623 Mbps – 1 Gbps 1 nsec 156 Mbps – 622 Mbps 2 nsec 125-155 Mbps 3 nsec <125 Mbps 7 nsec
For example, in Ethernet environments, ensure that the network conforms to the 512-bit Rule by using the above numbers to determine the 'bit-time' delay, as:
6
CFMFFxxxx-2xx
24-hour Technical Support: 1-800-260-1312 – International: 00-1-952-941-7600
Operation
Status LEDs
Use the three status LEDs on the media converter (shown here) to monitor its operation in the network.
PWR ON = Connection to external power.
LKS ON = Singlemode fiber link is up.
LKM ON = Multimode fiber link is up.
SNMP
Use SNMP at an attached terminal or at a remote location to monitor the media converter by monitoring:
• Media converter power
• Singlemode fiber link status
• Multimode fiber link status
Also, use SNMP to enter network commands that:
• Power down the media converter
• Disable the multimode transmitter
• Disable the singlemode transmitter
See the on-line documentation that comes with Transition Networks FocalPoint™ software for applicable commands and usage at www.transition.com.
Link Pass-Through
The Link Pass-Through feature allows the media converter to monitor RX (receive) ports for loss of signal. In the event of a loss of an RX signal on one media port, the media converter will automatically disable the TX (transmit) signal of the other media port, thus “passing through” the link loss.
7
techsupport@transition.com – Click the “Transition Now” link for a live Web chat.
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Singlemode fiber (recommended): 9 µm Multimode fiber (recommended): 62.5/125 µm Multimode fiber (optional): 100/140, 85/140, 50/125 µm
155 Mb/s fiber specifications (CFMFF13xx-20x)
Bit Error Rate: <10-9
Port 1: 1300 nm multimode duplex Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm Link Budget: 11.0 dB
Port 2: CFMFF1313-200 1300 nm multimode duplex
Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm Link Budget: 11.0 dB
CFMFF1314-200 1310 nm singlemode Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm Fiber-optic Receiver Sensitivity: min: -31.0 dBm max: -8.0 dBm Link Budget: 16.0 dB
CFMFF1315-200 1310 nm singlemode Fiber-optic Transmitter Power: min: -8.0 dBm max: -2.0 dBm Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm Link Budget: 26.0 dB
CFMFF1316-200 1310 nm singlemode Fiber-optic Transmitter Power: min: -5.0 dBm max: 0.0 dBm Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm Link Budget: 29.0 dB
CFMFF1317-200 1550 nm singlemode Fiber-optic Transmitter Power: min: -5.0 dBm max: 0.0 dBm Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm Link Budget: 29.0 dB
CFMFF1329-200 1310 nm (TX) / 1550 nm (RX) singlemode Fiber-optic Transmitter Power: min: -13.0 dBm max: -6.0 dBm Fiber-optic Receiver Sensitivity: min: -32.0 dBm max: -3.0 dBm Link Budget: 19.0 dB
CFMFF1329-201 1550 nm (TX) / 1310 nm (RX) singlemode Fiber-optic Transmitter Power: min: -13.0 dBm max: -6.0 dBm Fiber-optic Receiver Sensitivity: min: -32.0 dBm max: -3.0 dBm Link Budget: 19.0 dB
CFMFF1329-202 1310 nm (TX) / 1550 nm (RX) singlemode Fiber-optic Transmitter Power: min: -8.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -33.0 dBm max: -3.0 dBm Link Budget: 25.0 dB
CFMFF1329-203 1550 nm (TX) / 1310 nm (RX) singlemode Fiber-optic Transmitter Power: min: -8.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -33.0 dBm max: -3.0 dBm Link Budget: 25.0 dB
8
CFMFFxxxx-2xx
24-hour Technical Support: 1-800-260-1312 – International: 00-1-952-941-7600
Cable Specifications – Continued
155 Mb/s fiber specifications (CFMFF14xx-20x)
Bit Error Rate: <10-9
Port 1: 1310 nm singlemode duplex Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm Fiber-optic Receiver Sensitivity: min: -31.0 dBm max: -8.0 dBm Link Budget: 16.0 dB
Port 2: CFMFF1414-200 1310 nm singlemode duplex
Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm Fiber-optic Receiver Sensitivity: min: -31.0 dBm max: -8.0 dBm Link Budget: 16.0 dB
CFMFF1415-200 1310 nm singlemode Fiber-optic Transmitter Power: min: -8.0 dBm max: -2.0 dBm Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm Link Budget: 26.0 dB
CFMFF1429-200 1310 nm (TX) / 1550 nm (RX) singlemode Fiber-optic Transmitter Power: min: -13.0 dBm max: -6.0 dBm Fiber-optic Receiver Sensitivity: min: -32.0 dBm max: -3.0 dBm Link Budget: 19.0 dB
CFMFF1429-201 1550 nm (TX) / 1310 nm (RX) singlemode Fiber-optic Transmitter Power: min: -13.0 dBm max: -6.0 dBm Fiber-optic Receiver Sensitivity: min: -32.0 dBm max: -3.0 dBm Link Budget: 19.0 dB
CFMFF1429-202 1310 nm (TX) / 1550 nm (RX) singlemode Fiber-optic Transmitter Power: min: -8.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -33.0 dBm max: -3.0 dBm Link Budget: 25.0 dB
CFMFF1429-203 1550 nm (TX) / 1310 nm (RX) singlemode Fiber-optic Transmitter Power: min: -8.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -33.0 dBm max: -3.0 dBm Link Budget: 25.0 dB
9
techsupport@transition.com – Click the “Transition Now” link for a live Web chat.
Cable Specifications – Continued
622 Mb/s fiber specifications (CFMFF13xx-21x)
Bit Error Rate: <10-9
Port 1: 1300 nm multimode duplex Fiber-optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber-optic Receiver Sensitivity: min: -26.0 dBm max: -14.0 dBm Link Budget 7.0 dB
Port 2: CFMFF1314-210 1310 nm singlemode
Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm Fiber-optic Receiver Sensitivity: min: -28.0 dBm max: -7.0 dBm Link Budget: 13.0 dB
CFMFF1316-210 1310 nm singlemode Fiber-optic Transmitter Power: min: -3.0 dBm max: +2.0 dBm Fiber-optic Receiver Sensitivity: min: -28.0 dBm max: -7.0 dBm Link Budget: 25.0 dB
CFMFF1317-210 1550 nm singlemode Fiber-optic Transmitter Power: min: -3.0 dBm max: +2.0 dBm Fiber-optic Receiver Sensitivity: min: -28.0 dBm max: -7.0 dBm Link Budget: 25.0 dB
CFMFF1329-210 1310 nm (TX) / 1550 nm (RX) singlemode Fiber-optic Transmitter Power: min: -14.0 dBm max: -8.0 dBm Fiber-optic Receiver Sensitivity: min: -28.0 dBm max: -8.0 dBm Link Budget: 14.0 dB
CFMFF1329-211 1550 nm (TX) / 1310 nm (RX) singlemode Fiber-optic Transmitter Power: min: -14.0 dBm max: -8.0 dBm Fiber-optic Receiver Sensitivity: min: -28.0 dBm max: -8.0 dBm Link Budget: 14.0 dB
CFMFF1329-212 1310 nm (TX) / 1550 nm (RX) singlemode Fiber-optic Transmitter Power: min: -5.0 dBm max: 0.0 dBm Fiber-optic Receiver Sensitivity: min: -28.0 dBm max: -8.0 dBm Link Budget: 23.0 dB
CFMFF1329-213 1550 nm (TX) / 1310 nm (RX) singlemode Fiber-optic Transmitter Power: min: -6.0 dBm max: 0.0 dBm Fiber-optic Receiver Sensitivity: min: -28.0 dBm max: -8.0 dBm Link Budget: 22.0 dB
10
CFMFFxxxx-2xx
24-hour Technical Support: 1-800-260-1312 – International: 00-1-952-941-7600
Cable Specifications – Continued
622 Mb/s fiber specifications (CFMFF14xx-21x)
Bit Error Rate: <10-9
Port 1: 1310 nm singlemode Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm Fiber-optic Receiver Sensitivity: min: -28.0 dBm max: -7.0 dBm Link Budget: 13.0 dB
Port 2: CFMFF1429-210 1310 nm (TX) / 1550 nm (RX) singlemode
Fiber-optic Transmitter Power: min: -14.0 dBm max: -8.0 dBm Fiber-optic Receiver Sensitivity: min: -28.0 dBm max: -8.0 dBm Link Budget: 14.0 dB
CFMFF1429-211 1550 nm (TX) / 1310 nm (RX) singlemode Fiber-optic Transmitter Power: min: -14.0 dBm max: -8.0 dBm Fiber-optic Receiver Sensitivity: min: -28.0 dBm max: -8.0 dBm Link Budget: 14.0 dB
CFMFF1429-212 1310 nm (TX) / 1550 nm (RX) singlemode Fiber-optic Transmitter Power: min: -5.0 dBm max: 0.0 dBm Fiber-optic Receiver Sensitivity: min: -28.0 dBm max: -8.0 dBm Link Budget: 23.0 dB
CFMFF1429-213 1550 nm (TX) / 1310 nm (RX) singlemode Fiber-optic Transmitter Power: min: -6.0 dBm max: 0.0 dBm Fiber-optic Receiver Sensitivity: min: -28.0 dBm max: -8.0 dBm Link Budget: 22.0 dB
622 Mb/s Fiber Specifications (CFMFF1717-210)
Bit Error Rate: <10-9
Port 1 1310 nm singlemode Fiber-optic Transmitter Power: min: -3.0 dBm max: +2.0 dBm Fiber-optic Receiver Sensitivity: min: -28.0 dBm max: -7.0 dBm Link Budget: 25.0 dB
Port 2 1310 nm singlemode Fiber-optic Transmitter Power: min: -3.0 dBm max: +2.0 dBm Fiber-optic Receiver Sensitivity: min: -28.0 dBm max: -7.0 dBm Link Budget: 25.0 dB
11
techsupport@transition.com – Click the “Transition Now” link for a live Web chat.
Cable Specifications – Continued
1.25 Gb/s fiber specifications (CFMFF13xx-22x)
Bit error rate: <10-12
Port 1: 1300 nm multimode Fiber-optic Transmitter Power: min: -10.0 dBm max: -4.0 dBm Fiber-optic Receiver Sensitivity: min: -17.0 dBm max: 0.0 dBm Link Budget: 7.0 dB
Port 2: CFMFF1313-220 1300 nm multimode
Fiber-optic Transmitter Power: min: -10.0 dBm max: -4.0 dBm Fiber-optic Receiver Sensitivity: min: -17.0 dBm max: 0.0 dBm Link Budget: 7.0 dB
CFMFF1314-220 1310 nm singlemode Fiber-optic Transmitter Power: min: -13.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -20.0 dBm max: -3.0 dBm Link Budget: 7.0 dB
CFMFF1315-220 1310 nm singlemode Fiber-optic Transmitter Power: min: -5.0 dBm max: 0.0 dBm Fiber-optic Receiver Sensitivity: min: -20.0 dBm max: -3.0 dBm Link Budget / Spectral Width: 15.0 dB / 5.9 nm FWHM
CFMFF1317-220 1550 nm singlemode Fiber-optic Transmitter Power: min: -3.0 dBm max: +2.0 dBm Fiber-optic Receiver Sensitivity: min: - 23.0 dBm max: -3.0 dBm Link Budget / Spectral Width: 20.0 dB / 2.3 nm FWHM
CFMFF1324-220 1300 nm extended multimode Fiber-optic Transmitter Power: min: -10.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -17.0 dBm max: -3.0 dBm Link Budget: 7.0 db
CFMFF1329-220 1310 nm (TX) / 1550 nm (RX) singlemode Fiber-optic Transmitter Power: min: -8.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -21.0 dBm max: -3.0 dBm Link Budget: 13.0 dB
CFMFF1329-221 1550 nm (TX) / 1310 nm (RX) singlemode Fiber-optic Transmitter Power: min: -8.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -21.0 dBm max: -3.0 dBm Link Budget: 13.0 dB
CFMFF1329-222 1550 nm (TX) / 1310 nm (RX) singlemode Fiber-optic Transmitter Power: min: -3.0 dBm max: +2.0 dBm Fiber-optic Receiver Sensitivity: min: -23.0 dBm max: -8.0 dBm Link Budget: 20.0 dB
CFMFF1329-223 1550 nm (TX) / 1310 nm (RX) singlemode Fiber-optic Transmitter Power: min: -3.0 dBm max: +2.0 dBm Fiber-optic Receiver Sensitivity: min: -23.0 dBm max: -8.0 dBm Link Budget: 20.0 dB
CFMFF1335-220 1550 nm singlemode Fiber-optic Transmitter Power: min: 0.0 dBm max: +5.0 dBm Fiber-optic Receiver Sensitivity: min: -27.0 dBm max: -3.0 dBm Link Budget / Spectral Width: 27.0 db / 0.3 nm FWHM
12
CFMFFxxxx-2xx
24-hour Technical Support: 1-800-260-1312 – International: 00-1-952-941-7600
Cable Specifications – Continued
1.25 Gb/s fiber specifications (CFMFF14xx-22x)
Bit error rate: <10-12
Port 1: CFMFF1414-220 1310 nm singlemode
Fiber-optic Transmitter Power: min: -13.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -20.0 dBm max: -3.0 dBm Link Budget: 7.0 db
Port 2: CFMFF1414-220 1310 nm singlemode
Fiber-optic Transmitter Power: min: -13.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -20.0 dBm max: -3.0 dBm Link Budget: 7.0 db
Port 1: CFMFF1424-220 1310 nm singlemode
Fiber-optic Transmitter Power: min: -13.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -20.0 dBm max: -3.0 dBm Link Budget: 7.0 db
Port 2: CFMFF1424-220 1300 nm extended multimode
Fiber-optic Transmitter Power: min: -10.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -17.0 dBm max: -3.0 dBm Link Budget: 7.0 db
Port 1: CFMFF1429-220 1310 nm singlemode
Fiber-optic Transmitter Power: min: -13.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -20.0 dBm max: -3.0 dBm Link Budget: 7.0 db
Port 2: CFMFF1429-220 1310 nm singlemode
Fiber-optic Transmitter Power: min: -8.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -21.0 dBm max: -3.0 dBm Link Budget: 13.0 db
1.25 Gb/s Fiber Specifications (CFMFF1825-220)
Bit error rate: <10-12
Port 1: 850 nm multimode Fiber-optic Transmitter Power: min: -10.0 dBm max: -4.0 dBm Fiber-optic Receiver Sensitivity: min: -17.0 dBm max: 0.0 dBm Link Budget: 7.0 db
Port 2: 1310 nm singlemode Fiber-optic Transmitter Power: min: -11.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -20.0 dBm max: -3.0 dBm Link Budget/Spectral Width: 9.0 db/7.0 nm FWHM
13
techsupport@transition.com – Click the “Transition Now” link for a live Web chat.
Technical Specifications
Applies to Transition Networks Model CFMFFxxxx-2xx or equivalent
Standards IEEE 802.3™ 1998 Fast Ethernet, ATM, OC-3,
STM-1, HSTR, FDDI
Dimensions 3.4" x 0.86" x 5.0" (86 mm x 22mm x 127mm)
Weight 3 oz (91 g) (approximate)
MTBF 650,318 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
1,793,425 hours (Bellcore7 V5.0)
Delay 623 Mbps - 1 Gbps: 1 nsec
156 Mbps - 622 Mbps: 2 nsec 125-155 Mbps: 3 nsec <125 Mbps: 7 nsec
Power Consumption 3.0 watts (typical)
Environment Tmra*: 0°C to 50°C (32°F to 122°F )
Storage Temp: -20°C to 85°C (-4°F to 185°F ) Humidity: 10 to 90%, non condensing Altitude: 0 to 10,000 feet
Warranty Lifetime
*Manufacturer’s rated ambient temperature: “Tmra” range for this slide-in­module depends on the physical characteristics and the installation configuration of the Transition Networks PointSystem™ chassis in which this slide-in-module will be installed.
Note: The CFMFFxxxx-2xx media converters are for use in Transition Networks’
model CPSMCxxxx-xxx chassis only. See the CPSMCxxxx-xx chassis manuals, available on-line @ www.transition.com, for information about the chassis.
Note: For the most up-to-date information on the CFMFFxxxx-2xx media
converter, view the user’s guide on-line @ www.transition.com
Note The SFMFFxxxx-2xx model is the stand alone version of the media
converter. For more information, see the user’s guide on-line at: www.transition.com.
The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC-825/CDRH standards and complies with 21 CFR1040.10 and 21CFR1040.11.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.
CAUTION:
Visible and Invisible Laser Radiation When Open. Do Not Stare Into
Beam Or View Directly With Optical Instruments.
CAUTION:
Use of controls, adjustments or the performance of procedures other
than those specified herein may result in hazardous radiation exposure.
14
CFMFFxxxx-2xx
24-hour Technical Support: 1-800-260-1312 – International: 00-1-952-941-7600
Troubleshooting
If the media converter fails, isolate and correct the fault by determining the answers to the following questions and then taking the indicated action:
1. Is the
PWR (power)
LED on the media converter illuminated?
NO
• Is the media converter inserted properly into the chassis?
• Is the power cord properly installed in the chassis and at the external power source?
• Does the external power source provide power?
• Contact Technical Support: US/Canada: 1-800-260-1312, International: 00-1-952-941-7600.
YES
• Proceed to step 2.
2. Is the LKS (link singlemode) LED illuminated? NO
• Check the singlemode fiber cables for proper connection.
• Verify that the TX and RX cables on the media converter are
connected to the RX and TX ports, respectively, on the other device.
• Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
• Proceed to step 3.
3. Is the LKM (link multimode) LED illuminated? NO
• Check the multimode fiber cables for proper connection.
• Verify that the TX and RX cables on the media converter are
connected to the RX and TX ports, respectively, on the other device.
• Restart the workstation to restart the initialization process.
• Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
• Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
15
techsupport@transition.com – Click the “Transition Now” link for a live Web chat.
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 U.S.A. Model: CFMFFxxxx-2xx Series Media Converters Part Number(s): CFMFF1313-200, CFMFF1314-200, CFMFF1314-210, CFMFF1313-220,
CFMFF1314-220, CFMFF1315-200, CFMFF1315-220, CFMFF1316-200, CFMFF1316-210, CFMFF1317-200, CFMFF1317-210, CFMFF1317-220, CFMFF1717-210, CFMFF1329-200, CFMFF1329-201, CFMFF1329-202, CFMFF1329-203,CFMFF1329-210, CFMFF1329-211, CFMFF1329-212, CFMFF1329-213,CFMFF1329-220, CFMFF1329-221, CFMFF1329-222, CFMFF1329-223, CFMFF1414-200, CFMFF1415-200, CFMFF1429-200, CFMFF1429-201, CFMFF1429-202, CFMFF1429-203,CFMFF1429-210, CFMFF1429-211, CFMFF1429-212, CFMFF1429-213, CFMFF1324-220, CFMFF1825-220, CFMFF1335-220, CFMFF1414-220, CFMFF1424-220
CFMFF1429-220 Regulation: EMC Directive 89/336/EEC Purpose: To declare that the
CFMFFxxxx-2xx
to which this declaration refers is
in conformity with the following standards.
EN 55022:1994, A-1:1995, A-2:1997 Class A&B; FCC Part 15 Subpart B; UL1950 EN 55024:1998; EN 61000-3-2:1995; EN 61000-3-3:1995; 21CFR subpart J
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
May, 2005_____
Stephen Anderson, Vice-President of Engineering Date
Contact Us
Technical support
Technical support is available 24 hours a day. US and Canada: 1-800-260-1312 International: 00-1-952-941-7600
Transition now
Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link.
Web-Based seminars
Transition Networks provides seminars via live web-based training. Log onto www.transition.com and click the Learning Center link.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff. techsupport@transition.com
Address
Transition Networks 6475 City West Parkway Minneapolis, MN 55344, U.S.A. telephone: 952-941-7600 toll free: 800-526-9267 fax: 952-941-2322
Trademark notice
All registered trademarks and trademarks are the property of their respective owners.
Copyright restrictions
© 2000 - 2004 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means—graphic, electronic, or mechanical—without written permission from Transition Networks.
Compliance Information
UL Listed Accessory C-UL Listed (Canada) CISPR22/EN55022 Class A & B + EN55024 CE Mark
FCC regulations
This equipment has been tested and found to comply with the limits for a Class A & B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's own expense.
Canadian regulations
This digital apparatus does not exceed the Class A & B limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A & B prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
Printed in the U.S.A. 33173.T
In accordance with European Union Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003, Transition Networks will accept post usage returns of this product for proper disposal. The contact information for this activity can be found in the 'Contact Us' portion of this document.