Transition Networks CFMFF1316-210, CFMFF1329-211, CFMFF1317-210, CFMFF1329-210, CFMFF1329-212 User Manual

...
CFMFF1717-210 SC, 1550 nm singlemode
60 km (37.2 miles)
SC, 1550 nm singlemode 60 km (37.2 miles)
CFMFFxxxx-2xx User’s Guide
• Slide-in-Module Media Converter
• Fast Ethernet, ATM, SONET, or Gigabit
Transition Networks CFMFFxxxx-2xx series media converters extend multimode and singlemode interfaces to singlemode fiber optic cable over Fast Ethernet, ATM, SONET, and Gigabit networks. The CFMFFxxxx-2xx is also designed to install into the Transition Networks PointSystem™ chassis.
622 Mb/s cable speed:
The models with the -21x extension are for cable speeds of 622 Mb/s and extend ATM or SONET over singlemode fiber up to 60 km.
Part Number Port One - Fiber-Optic Port Two - Fiber-Optic
CFMFF1314-210 SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1310 nm singlemode 15 km (9.3 miles)
CFMFF1316-210 SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1310 nm singlemode 40 km (24.8 miles)
CFMFF1317-210 SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1550 nm singlemode 60 km (37.2 miles)
CFMFF1329-210 SC, 1300 nm multimode
duplex, 2 km (1.2 miles)
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1329-211 SC, 1300 nm multimode
duplex, 2 km (1.2 miles)
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1329-212 SC, 1300 nm multimode
duplex, 2 km (1.2 miles)
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 40 km (24.8 mi)
CFMFF1329-213 SC, 1300 nm multimode
duplex, 2 km (1.2 miles)
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 40 km (24.8 mi)
CFMFF1429-210 SC, 1310 nm singlemode
duplex, 15 km (9.3 miles)
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1429-211 SC, 1310 nm singlemode
duplex, 15 km (9.3 miles)
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1429-212 SC, 1310 nm singlemode
duplex, 15 km (9.3 miles)
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 40 km (24.8 mi)
CFMFF1429-213 SC, 1310 nm singlemode
duplex, 15 km (9.3 miles)
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 40 km (24.8 mi)
Installation . . . . . . . . . . . . . . . . . .4
Operation . . . . . . . . . . . . . . . . . . .6
Cable Specifications . . . . . . . . . . .7
Technical Specifications . . . . . . .13
Troubleshooting . . . . . . . . . . . . .14
Compliance Information . . . . . . .16
2
CFMFFxxxx-2xx
24-hour Technical Support: 1-800-260-1312 – International: 00-1-952-941-7600
155 Mb/s cable speed:
The models with the -20x extension are for cable speeds of 155 Mb/s and extend ATM or Fast Ethernet over singlemode fiber up to 80 km.
CFMFF1329-202 SC, 1300 nm multimode
duplex, 2 km (1.2 miles)
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 40 km (24.8 mi)
CFMFF1329-203 SC, 1300 nm multimode
duplex, 2 km (1.2 miles)
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 40 km (24.8 mi)
CFMFF1429-200 SC, 1310 nm singlemode
duplex, 20 km (12.4 miles)
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1429-201 SC, 1310 nm singlemode
duplex, 20 km (12.4 miles)
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1429-202 SC, 1310 nm singlemode
duplex, 20 km (12.4 miles)
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 40 km (24.8 mi)
CFMFF1429-203 SC, 1310 nm singlemode
duplex, 20 km (12.4 miles)
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 40 km (24.8 mi)
Part Number Port One - Fiber-Optic Port Two - Fiber-Optic
CFMFF1314-200 SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1310 nm singlemode 20 km (12.4 miles)
CFMFF1313-200 SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1300 nm multimode 2 km (1.2 miles)
CFMFF1315-200 SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1310 nm singlemode 40 km (24.8 miles)
CFMFF1316-200 SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1310 nm singlemode 60 km (37.2 miles)
CFMFF1317-200 SC, 1300 nm multimode
2 km (1.2 miles)
SC, 1550 nm singlemode 80 km (49.7 miles)
CFMFF1329-200 SC, 1300 nm multimode
duplex, 2 km (1.2 miles)
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1329-201 SC, 1300 nm multimode
duplex, 2 km (1.2 miles)
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 20 km (12.4 mi)
The cable distances listed are typically maximum. The actual maximum cable distances are dependent upon the physical characteristics of the network installation.
SM = singlemode, TX = transmit, RX = receive.
CFMFF1414-200 SC, 1310 nm singlemode
duplex, 20 km (12.4 miles)
SC, 1310 nm singlemode duplex, 20 km (12.4 miles)
CFMFF1415-200 SC, 1310 nm singlemode
duplex, 20 km (12.4 miles)
SC, 1310 nm singlemode 40 km (24.8 miles)
1.25 Gb/s cable speed:
The models with the -22x extensions are for cable speeds of 1.2Gb/s and can extend gigabit Ethernet over a singlemode fiber up to 125 km.
3
techsupport@transition.com – Click the “Transition Now” link for a live Web chat.
Part Number Port One – Fiber Optic
Port Two – Fiber-Optic
CFMFF1314-220 SC, 850 nm multimode
220 m (721 ft)**
SC, 1310 nm singlemode 10 km (6.2 miles)
CFMFF1315-220 SC, 850 nm multimode
220 m (721 ft)**
SC, 1310 nm singlemode 25 km (15.5 miles)
CFMFF1317-220 SC, 850 nm multimode
220 m (721 ft)**
SC, 1550 nm singlemode 65 km (40.3 miles)
CFMFF1324-220 SC, 850 nm multimode
220 m (721 ft)**
SC, 1300 nm extended MM up to 2 km (1.2 miles)
(62.5/125 mm fiber only)
CFMFF1335-220 SC, 850 nm multimode
220 m (721 ft)**
SC, 1550 nm singlemode 125 km (77.5 mi)
CFMFF1414-220 SC, 1310 nm singlemode
10 km (6.2 miles)
SC, 1310 nm singlemode 10 km (6.2 miles)
CFMFF1424-220 SC, 1310 nm singlemode
10 km (6.2 miles)
SM = singlemode, MM = multimode, TX = transmit, RX = receive.
Unless otherwise indicated, the distances listed are the typical maximum cable distance. The actual maximum cable distances are dependent upon the physical characteristics of the network installation.
** Minimum cable distance: 2 meters
Typical maximum cable distance: 220 meters for 160/500MHz•Km
270 meters for 200/500MHz•Km
CFMFF1313-220 SC, 850 nm multimode
220 m (721 ft)**
SC, 850 nm multimode 220 m (721 ft)**
CFMFF1429-220
SC, 1310 nm singlemode 10 km (6.2 miles)
SC, 1300 nm extended MM up to 2 km (1.2 miles)
(62.5/125 mm fiber only)
CFMFF1825-220 MJ-RJ, 850 nm multimode
220 m (721 ft)
MJ-RJ, 1310 nm singlemode 10 km (6.2 miles)
CFMFF1329-220 SC, 850 nm duplex MM
220 m (721 ft)**
SC, 1310 nm (TX)/1550 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1329-221 SC, 850 nm duplex MM
220 m (721 ft)**
SC, 1550 nm (TX)/1310 nm (RX) SM single fiber, 20 km (12.4 mi)
CFMFF1329-222 SC, 850 nm multimode
220 m (721 ft)**
SC, 1310 nm (TX)/1550 nm (RX) SM SF, 40 km (24.9 miles)
CFMFF1329-223 SC, 850 nm multimode
220 m (721 ft)**
SC, 1310 nm (TX)/1550 nm (RX) SM SF, 40 km (24.9 miles)
SC, 1310 nm (TX)1550 nm (RX) SM single fiber, 20 km (12.4 mi)
4
CFMFFxxxx-2xx
24-hour Technical Support: 1-800-260-1312 – International: 00-1-952-941-7600
Installation
Install these Models in Pairs
The following media converter pairs are to be installed in the same network, where one serves as the local converter and the other a remote converter (either converter can be installed in either location).
155 Mb/s network:
• CFMFF1329-200 and CFMFF1329-201
• CFMFF1329-202 and CFMFF1329-203
• CFMFF1429-200 and CFMFF1429-201
• CFMFF1429-202 and CFMFF1429-203
622 Mb/s network:
• CFMFF1329-210 and CFMFF1329-211
• CFMFF1329-212 and CFMFF1329-213
• CFMFF1429-210 and CFMFF1429-211
• CFMFF1429-212 and CFMFF1429-213
1.2 GB/s network:
• CFMFF1329-220 and CFMFF1329-221
• CFMFF1329-222 and CFMFF1329-223
Install Slide-in-module in PointSystem™ chassis
CAUTION: Slots in the PointSystem™ chassis without a slide-in-module MUST have a protective plate covering the empty slot for Class B compliance.
The media converter slide-in-modules may be installed in any slot, in any order.
To install the slide-in-module:
1. Carefully slide the slide-in-module into the slot, aligning the module’s circuit board with the slot guides.
2. Ensure that the module is firmly seated in the chassis slot.
3. Secure the module by pushing its fastern in and turning it clockwise.
5
techsupport@transition.com – Click the “Transition Now” link for a live Web chat.
Installation – Continued
Install the fiber cable
CAUTION: Both connections (Port 1 and Port 2) to the CFMFFxxxx-2xx media converter must be the same network speed and network protocol. Failure to observe this caution could cause data transfers to fail.
1. Locate or build IEEE 802.3™ compliant fiber cable with male, two­stranded TX to RX connectors installed at both ends.
2. Connect the fiber cables to the CFMFFxxxx-2xx media converter as described:
• Connect the male TX cable connector to the female TX port.
• Connect the male RX cable connector to the female RX port.
3. Connect the fiber cables to the other device (another media converter, hub, etc.) as described:
• Connect the male TX cable connector to the female RX port.
• Connect the male RX cable connector to the female TX port.
Power the Media Converter
The media converter is powered through the Transition Networks PointSystem™ chassis.
Delay Times
Network worst-case delay through the CFMFFxxxx-2xx converter: 623 Mbps – 1 Gbps 1 nsec 156 Mbps – 622 Mbps 2 nsec 125-155 Mbps 3 nsec <125 Mbps 7 nsec
For example, in Ethernet environments, ensure that the network conforms to the 512-bit Rule by using the above numbers to determine the 'bit-time' delay, as: