Transition Networks C-E-100BTX-FRL-03SM, C-E-100BTX-FRL-03SC, C-E-100BTX-FRL-03 User Manual

The TRANSITION Networks 100BASE-TX to 100BASE-FX slide-in-module media converters,
C/E-100BTX-FRL-03, C/E-100BTX-FRL-03(SC) and C/E-100BTX-FRL-03(SM),
which are designed to be installed in the TRANSITION Networks Media Conversion Center,
E-MCC-1600
, connect 100BASE-TX unshielded twisted pair cable to 100BASE­FX multimode OR singlemode fiber-optic cable. All media converters function in half- duplex mode or, when connected to devices capable of full-duplex connectivity, in full­duplex mode. An MDI/MDI-X switch allows straight-through twisted-pair cable to be used for crossover 100BASE-TX connections.
Minneapolis, MN 55344 USA
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Compliance Information
UL Listed C-UL Listed (Canada) CISPR/EN55022 Class B
FCC Regulations
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class B limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
Copyright Restrictions
© 1998, 1999 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners. 33044.C
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
MEDIA CONVERTER TECHNICAL SPECIFICATIONS
Standards IEEE 802.3u Environment Temperature: 0-40°C (32° to 104° F )
Humidity 10-90%, non condensing Altitude 0-10,000 feet
Warranty Five years
100BASE-TX/100BASE-FX
Slide-In-Module Media Converters
C/E-100BTX-FRL-03, C/E-100BTX-FRL-03(SC), C/E-100BTX-FRL-03(SM)
USER’S GUIDE
C/E-100BTX-FRL-03
Provides an RJ-45 twisted pair 100BASE-TX connector and a set of RX (receive) and TX (transmit) ST 100BASE-FX connectors to multimode fiber-optic cable.
C/E-100BTX-FRL-03(SC)
Provides an RJ-45 twisted pair 100BASE-TX connector and an RX (receive) and TX (transmit) SC 100BASE-FX connector to multimode fiber-optic cable.
C/E-100BTX-FRL-03(SM)
Provides an RJ-45 twisted pair 100BASE-TX connector and an RX (receive) and TX (transmit) SC 100BASE-FX connector to singlemode fiber-optic cable.
Power Illuminated green LED indicates connection to external
AC power.
SDF Signal Detect/Fiber: Steady green LED indicates fiber port
is connected to device.
SDC Signal Detect/Copper: Steady green LED indicates RJ-45
port is connected to device.
RXC Receive/Copper: Flashing green LED indicates packets
are seen on RJ-45 port.
RXF Receive/Fiber: Flashing green LED indicates packets are
seen on fiber port.
P
Status LEDs
Straight-through Cable Configuration
Straight-through/crossover 100BASE-TX requirements are satisfied using the MDI/MDI-X switch with straight-through cable.
The two active pairs in a 100BASE-TX network are pins 1 & 2 and pins 3 & 6. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins.
Straight Through Cable
Twisted Pair #1
Twisted Pair #2
1 2
3 6
1 2
3 6
P
100BASE-FX 100BASE-TX
TM
Fast Ethernet
C/E-100BTX-FRL
-03
C/100BTX-FRL-03
100BASE-TX
100BASE-FX 100BASE-TX
TM
-
Copper
100BASE-FX Multimode Fiber
-
-
-
P
100BASE-FX 100BASE-TX
TM
Fast Ethernet
C/E-100BTX-FRL
-03
P
Fast Ethernet
C/E-100BTX-FRL
-03
100BASE-TX Copper
100BASE-FX Multimode Fiber
100BASE-TX Copper
100BASE-FX Singlemode Fiber
1. Is the power LED on the media converter illuminated?
NO
Is the Slide-In-Module properly connected to the Media Conversion Center chasis backplane?
Is the Power Supply Module properly connected both to the Media Conversion Center chasis backplane and to the AC outlet?
Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
Proceed to step 2.
2. Is the 100BASE-TX Link LED illuminated?
NO
Check UTP cables for proper connection and pin assignment. (See above.)
Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
Proceed to step 3.
3. Is the fiber Link LED illuminated?
NO
Check fiber cables for proper connection.
Verify that TX and RX cables on media converter are connected to RX and TX ports, respectively, on the other 100BASE-FX device.
Refer to Tech Tips available at: http://www.transition.com
Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
Troubleshooting
The physical characteristics of the media cable must meet or exceed IEEE
802.3u 100BASE-TX and 100BASE-FX specifications.
ETHERNET CABLE SPECIFICATIONS
100BASE-FX CABLE SPECIFICATIONS
SINGLEMODE
Fiber-optic Cable Recommended: 9 µm singlemode fiber Fiber-optic Transmitter Power: min: -15.0
dBm max: -8.0 dBm
Fiber-optic Receiver Sensitivity: min: -32.5 dBm max: -8.0 dBm Wavelength: 1300nM Bit error rate: 10
-9
Maximum Cable Distance: 20 kilometers
MULTIMODE
Fiber-optic Cable Recommended: 62.5 / 125 µm multimode fiber
Optional: 100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber Fiber-optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber-optic Receiver Sensitivity: min: -32.5 dBm max: -14.0 dBm Wavelength: 1300nM Bit error rate: 10
-9
Maximum Cable Distance: 2 kilometers
100BASE-TX CABLE SPECIFICATIONS
Category 5 wire or better is required. Either shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. Use a straight­through cable configuration (see back page).
CATEGORY 5:
Gauge 24 to 22 AWG Attenuation 20 dB/1000’ @ 10 MHz Impedance 100 Ω ±10% @ 10 MHz
Maximum Cable Distance: 100 meters (330 feet)
Installing Slide-In-Module(s)
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when installing Media Converter Slide-in-Module(s) in the 16-Slot Media Conversion Center. Failure to observe this caution could result in damage to, and subsequent failure of, the Media Converter Slide-in-Module(s).
NOTE: Media Converter Slide-in-Modules can be installed in any installation slot, in any order.
To install the Media Converter Slide-in-Module in the E-MCC-1600 chassis:
1. Remove Media Converter Slide-in-Module protective plate from selected installation slot by removing two screws that secure plate to front of E-MCC-1600. Retain one installation screw.
2. Carefully slide Media Converter Slide-in-Module into installation slot, aligning Media Converter Slide-in-Module with installation guides. NOTE: Ensure that the Media Converter Slide-in-Module is firmly seated against the backplane.
3. Secure Slide-in-Module by installing retained installation screw.
100BASE-FX CABLE CONNECTIONS
Be certain that the correct mode and wavelength fiber cable is used for single­mode and/or for multimode fiber cable installations.
100BASE-TX CABLE CONNECTIONS
Be certain that the MDI/MDI-X switch located ON the Slide-In-Module circuit board is set correctly before installing Slide-In-Module in Media Conversion Center. Cable connections between a hub and the media converter require the
MDI/MDI-X switch to be set to MDI. Cable connections between the media converter and a terminal, transceiver or NIC require the switch to be set to MDI­X.
Using small flatblade screwdriver or similar tool, set MDI/MDI-X switch position for site installation.
C/E-100BTX-FRL-03
MDI position
Set switch
MDI-X position
Leave in default position
toward network connectors toward chassis