Installation NOTES
To install the C/B-CF-01 series media converter:
1. Install the C/B-CF-01 in the E-MCC-1600 chassis.
NOTE: Media Converter Slide-in-Modules can be installed in any
installation slot, in any order.
• Remove Media Converter Slide-in-Module protective plate
from selected installation slot by removing two screws that
secure plate to front of E-MCC-1600. Retain one installation
screw.
• Carefully slide Media Converter Slide-in-Module into
installation slot, aligning Media Converter Slide-in-Module
with installation guides.
NOTE: Ensure that the Media Converter Slide-in-Module is firmly
seated against the backplane.
• Secure Slide-in-Module by installing retained installation
screw.
2. Connect host signal to C/B-CF-01 media converter.
NOTE: Set the configuration switch (located on the side of the media
converter) according to site requirements, using the following:
Switch 1 NOT USED
Switch 2 UP = Twisted Pair
DOWN = Coax
Twisted-pair:
• Locate or build twisted-pair cables (See specifications, page 7)
with male RJ-45 plug connectors at both cable ends.
NOTE: Install TRANSITION Networks balun part number: B-4554
between RJ-45 cable and coax connector.
• Install balun at host coax connector.
• Connect male RJ-45 plug connector at one end of twisted pair
cable to balun on host coax connector.
• Connect male RJ-45 plug connector at other end of cable to
female RJ-45 connector on B-CF-01 media converter.
Coax:
• Locate or build coaxial RG-62 cables (See specifications, page
7) with male BNC connectors at both ends.
CABLE SPECIFICATIONS
The physical characteristics of the cable must meet or exceed the following:
FIBER CABLE
MULTIMODE
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber
Fiber Optic Transmitter Power: min: -19.0
dBm
max: -14.0 dBm
Fiber Optic Receiver Sensitivity: min: -32.5 dBm max: -14.0 dBm
Wavelength: 850nM
Bit error rate: ≤10
-9
Maximum Cable Distance: 2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended: 9 µm singlemode fiber
Fiber Optic Transmitter Power: min: -27.0 dBm max: -17.0 dBm
Fiber Optic Receiver Sensitivity: min: -32.5 dBm max: -13.0 dBm
Wavelength: 1300nM
Bit error rate: ≤10
-9
Maximum Cable Distance: 8 kilometers
TWISTED PAIR CABLE AND CONNECTOR
Category 3 wire or better is required; category 5 wire is recommended. Either
shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO
NOT USE FLAT OR SILVER SATIN WIRE.
Category 3:
Gauge 24 to 22 AWG
Attenuation 28 dB/1000’ @ 10 MHz
Differential Characteristic Impedance 100 Ω ±10% @ 10 MHz
Category 5:
Gauge 24 to 22 AWG
Attenuation 20 dB/1000’ @ 10 MHz
Differential Characteristic Impedance 100 Ω ±10% @ 10 MHz
Minimum UTP/STP Cable Distance: 1.8 meters (6 feet)
Maximum UTP/STP Cable Distance: 762 meters (2500 feet)
RG-62 Cable
Cable Characteristics:
Cable type: Coaxial RG-62
Impedance: 93 Ω @ 10 MHz
Mutual Capacitance: 13 pF/ft ±20% @ 10 MHz
Maximum Cable Distance: 307 meters (1000 feet)
Minimum Distance/Connection: 1.8 meters (6 feet)
7
2
All cable connections to the C/B-CF-01 MUST be
AT LEAST 7.6 meters (25 feet) in length.
C/B-CF-01