To extend the life of your electronic scale, do not drop items to be weighed onto the
platform or overload the scale beyond its rated capacity. Shock-loading and overloading may damage the electronic components and void the warranty.
In Case of Trouble... .................................................................................................................... 14
Warranty and Service Information............................................................................................... 15
Page 3
Introduction
The EL-3000 Counting Scale, available in several capacities, is an easy to use, high resolution
counting scale featuring several programmable
weigh modes, multi-item print function, and a
weight accumulator.
Housed in a durable ivory-colored plastic enclosure, the unit displays its numerals on a 5½-digit
LCD type display. A removable 8"x 9" stainless
steel platform allows for easy cleaning when
used to count greasy or dusty items. A plastic
skirt is also included to protect the scale’s outer
enclosure.
The unit can transmit on demand or continuously
in a popular data protocol. A multi-item print
mode is also included for use with a printer.
A 5-key membrane panel contains all of the
scale's functions. A durable 8" x 9" stainless steel
platform allows for accurate piece counting.
A battery power option is available which allows
the unit to operate for approximately 10 hours on
a charge. The scale can then be charged overnight in a period of 8 to 10 hours.
Getting Started
After unpacking the scale, a small amount of assembly is required:
Locate the sub-platform, four (4) Hex screws, and enclosed Allen wrench. Place sub-platform onto
scale's load point with all rubber parts facing up. Install and tighten the four Hex screws.
Plug the enclosed adapter into the scale first, then an AC outlet.
If using the scale with a printer or remote device, plug the connecting serial cable into the DB-9 con-
nector on the back of the scale.
If the optional battery operation was ordered, please charge the battery overnight before using. See
Optional Battery Operation on Page 9 for more information.
Please Do...
Place the scale on a firm and stable floor or table.
If possible, leave the scale on for at least 20 minutes before using. You will find the ON/OFF switch
at the bottom of the scale on the right, towards the back.
Press the
key before operating the scale.
ZERO
Please Do Not...
Share an AC outlet with other noise producing products; i.e. anything with an electrical motor or re-
lay.
Operate the scale...
...in an area with changing ambient temperature.
...in direct sunlight.
...in an area with high humidity.
...in a dusty environment.
...in a windy area.
...in an area with vibration.
EL 3000 Operating Manual
1
Page 4
Basics of Operation
g
DISPLAY & KEYPAD OVERVIEW
Zero Annunciator
is shown when indication
is at the center of zero.
Stable Annunciator
provides motion detection.
Weight Indication
Units Indication
Memory Indication
Unit Wt.
MODE
pcs
lb
kg
HI
oz
OK
%
LO
Low Battery
Indication
ZERO
CLEAR
ZERO/CLEAR Key
zeroes the scale. When
held for a few seconds,
clears scale memory.
MODE Key
toggles the units
amon
those enabled.
Memory Recall Key
briefly displays contents
of accumulator memory.
Memory Plus Key
adds the current indication
to memory. Can be any
unit.
MR
O
T
E
G
M+
SAMPLE Key
enters a sample
when in Pieces
or Percentage
modes.
N
Mem
MR
SAMPLE
INDICATION MEANING
Weight
Indicates the weight currently on the platform. When the full scale capacity has
been exceeded, the scale shows "."
Units
Indicates the unit of the weight currently on the platform. The Unit Wt. indicator
shows the unit weight of a piece sampled while in the pieces mode.
Memory
"MEM” indicates that there is a reading in memory. "MR" indicates that the
reading on the display is from the memory accumulator.
Zero
Stable
Low Battery
Indicates that the weight reading is at the scale's zero position.
Indicates that the scale is stable and that the reading on the scale is valid.
If the optional battery operation was ordered, indicates that the internal battery
needs charging. See Optional Battery Operation on Page 9 For more
information.
Revision 2.95
2
Page 5
Percentage Operation
The EL 3000 Digital Scale contains a percentage operation which is useful for such applications as
filling, check weighing and moisture determination.
The total weight of the item being sampled determines the resolution of the percentage readout. For
example, if the sample weight is greater than or equal to 10,000 external scale divisions, the scale will
discern 0.01% increments. See table below more information.
To use the percentage operation:
1. Toggle the
MODE
key until the scale is in “%” mode. If there is no previous sample entered, the
scale will respond with the following display indication. If the following message does not appear,
press the
SAMPLE
This display indication is prompting you to
place 100% of the sample on the platform all
at once.
NOTE
accident, you can press the
escape.
2. Press the
ZERO
3. Place the sample on the platform all at once.
When the "Stable" flag becomes lit, the
display should look like this:
key once.
: If you entered this screen by
key to
MODE
key to zero the scale.
O
T
E
G
N
pcs
lb
kg
HI
oz
OK
%
LO
O
T
E
G
N
pcs
lb
kg
HI
oz
OK
%
LO
4. Press the
SAMPLE
key. If the sample weight is over the required sample weight, the scale will now
show the sample as being 100%. If not, a “Lo” message will flash briefly, prompting you for a
heavier sample. See table below for more information.
Percentage Operation Sample Weight Guide:
The minimum sample weight is 100 scale graduations. This will allow the scale to discern 1 part in 100.
To get a higher resolution, use 1,000 or even 10,000 times the scale’s graduations as your sample
weight. Below are three examples to help determine the best sample weight for your application.
Capacity / Graduation Minimum Sample Weight
30 lbs x 0.002-lbs 0.200-lbs 20-lbs
1200 g x 0.1 g 10 g 1000 g
6 lbs x 0.0005-lbs 0.05-lbs 5-lbs
(100 Graduations)
Best Sample Weight
(10,000 Graduations)
EL 3000 Operating Manual
3
Page 6
Piece Counting Operation
The EL 3000 Digital Scale uses the
sampling
method to determine the number of pieces on
the platform. The accuracy of this operation
depends upon part consistency and sample
weight. When sampling pieces, always count the
parts in your hand and place them on the
platform all at once.
by applying small quantities of pieces – two to
current piece count – to the platform. For example, if the current piece count shown on the display is 10, then adding 2 to 10 more pieces to
the platform at the same time will trigger AAWI.
When this occurs, the "Unit Wt." indication will
flash briefly.
To further increase the accuracy of this operation, the EL 3000 contains an algorithm called
"Automatic Average Weight Improvement"
(AAWI) which allows updating of the piece count
The total sample weight and the unit piece
weight both have limits to assure accuracy.
These limits can be found in the table at the bottom of the page.
by applying
To use the piece counting operation:
1. Toggle the
MODE
key until the scale is in “pcs” mode. If there is no previous sample entered, the
scale will respond with the following display indication. If the following message does not appear,
press the
SAMPLE
This display indication is prompting you to
place 10 identical samples on the platform
all at once.
NOTE
by accident, you can press the
key once.
: If you entered this screen
key to
MODE
O
T
E
G
N
pcs
lb
kg
HI
oz
OK
%
LO
escape.
2. Press the
3. Place 10 identical samples on the platform
all at once. When the "Stable" flag becomes
lit, the display should look like this:
key to zero the scale.
ZERO
pcs
lb
OK
G
kg
LO
4. Press the
SAMPLE
will now show the number of pieces. If not, you will be prompted to place
key. If the sample weight and/or unit weight is within the proper limits, the scale
20, 50, 100, 200 and 500
pieces on the platform in succession. If this operation fails even with 500 pieces, the unit weight of
the objects you wish to count is not heavy enough for the scale to process accurately. See table
below for more information.
Piece Count Sample Weight Guide:
The scale has both a minimum piece weight and a minimum sample weight to ensure accuracy. To
obtain the minimum piece weight, multiply the scale’s graduation by 0.8. To obtain the minimum sample
weight, multiply the scale’s graduation by 25. Shown below is an example for a 12 lb scale:
The EL-3000 comes equipped with a handy accumulator function which works in conjunction with all of
the scale's displayable units except Unit Weight. The accumulator uses a memory to store the weight
readings and piece counts. Much like a pocket calculator, this memory can be added to, displayed, and
cleared at any time.
When used with a printer, the EL-3000 prints the weight each time the M+ key is pressed and prints
the accumulated total when the MR key is pressed. See Multi-Item Print on Page 8 for more
information.
To use the accumulator function:
1. Use the
2. If the "MEM" indication is lit, press and hold the
key to toggle to the desired unit you wish to count.
MODE
ZERO/CLEAR
key to clear the accumulator
memory. The scale briefly displays "CL" to indicate that memory has been cleared.
3. Place the objects to count on the platform.
4. After the "STABLE" indication becomes lit,
press the M+ key to add this value to the
accumulator's memory. The scale reading
flashes once and the "MEM" indication
becomes lit to show that there is a value in
O
T
E
G
N
MemMR
memory.
5. Repeat steps 3 & 4 until all pieces are counted.
6. Press the MR key to briefly view the
contents of the accumulator. The "MR"
indication turns on to indicate that the
reading is from memory.
O
T
E
G
N
MemMR
Unit Wt.
Unit Wt.
pcs
lb
kg
pcs
lb
kg
HI
oz
OK
%
LO
HI
oz
OK
%
LO
EL 3000 Operating Manual
5
Page 8
Disabling or Enabling Units
This section is for users who wish to disable some of the available weight units displayable on the EL-
3000.
When first purchased, the EL-3000 comes with all available displayable units enabled. The units appear
in the following sequence with each press of the
LBkggoz%PcsUnit Wt.
MODE
key:
If the Pieces mode is disabled, the Unit Wt. Mode will automatically be disabled.
NOTE:
To enable or disable displayable units:
1. Turn the scale off. You will find the ON/OFF switch on the bottom of the scale, near the back.
2. While holding down the
key, turn the scale back on. Continue holding down the
MODE
MODE
key
until the scale shows the “LB” unit with either the “ON” message or the “OFF” message.
The “ON” and “OFF” messages designate the unit’s status, either enabled or disabled.
3. To change a unit’s status, press the
SAMPLE
key. Each press of the
SAMPLE
key will toggle the
shown unit between “ON” and “OFF”.
4. To change to the next unit, press the
MODE
key.
5. Repeat steps 3 and 4 until all units have been programmed as desired.
6. Once the desired units have been enabled or disabled, save the configuration by pressing the
ZERO/CLEAR
key to resume normal operation.
Revision 2.95
6
Page 9
User Configuration
All user parameters are embedded in a users
menu consisting of 5 separate menu selections,
each with its own sub-menu of choices. If your
scale is connected by RS-232 serial communication lines to other equipment, or you wish to
select the automatic power off period (battery
option only), you may have to modify some or all
of these parameters. To modify these parame-
ters
T o place the unit in USER MENU mode:
Turn the scale off.
While holding down the MR key,
turn the scale back on.
When the display shows "A1",
the unit is in USER MENU mode,
and you can release the MR key.
Shown at right are the directional
and SET key assignments.
USER MENU CHART
parameters, you must first enter the USER
MENU mode.
Once there, four of the front panel keys become
directional navigators to move around in the
menus, and one key is used to save or SET the
selections. Complete directions start below.
MR MEM Unit Wt
SET
EL-3000 in User Menu Mode
A1
Baud Rate
1200 2400 4800 9600
A2
Data Bits, Parity
87o7E
A3
Transmission Mode
Cd
A4
Serial Data Format
01
A5
Auto Power Off Period
OFF 1 3 5
10
15 20
30
To place the unit back into the NORMAL OPERATING mode, turn off the power to the unit.
With no keys held down, turn the power back on. All front panel keys will now return to
their normal mode of operation.
EL 3000 Operating Manual
7
Page 10
User Menu Descriptions
NAME/CODEDESCRIPTIONCODE/VALUE
A1
Baud Rate
A2
Data Bits and
Parity
A3
Mode of Serial
Transmission
A4
Serial Data
Format
A5
Auto Power Off
Period
Selects the baud rate for data transmission through the serial port. 1200 2400
4800 9600
Selects the number of data bits and parity of serial transmission.
"8" = 8 data bits with no parity bit
"7O" = 7 data bits with odd parity bit
"7E" = 7 data bits with even parity bit
Selects when data will be sent out of the serial port to a printer or
computer:
"d" = Demand mode; send data when a PRINT command is issued
Selects either full duplex mode or multi-item print mode. See Serial
Data Format section for more information.
Selects the auto power off time in minutes. Scale must be idle during
this period.
"C" = Continuous mode; send data continuously
from the printer, computer, or indicator.
"0" = Full Duplex Mode
"1" = Multi-item (Simplex) Mode
"OFF" = Indicates this feature is disabled.
8
7O
7E
C
d
0
1
OFF, 1, 3, 5, 10,
15, 20, 30
Notes on A5 Auto Power Off Period:
1. Should be set to “OFF” if there is no internal battery.
2. The scale “chirps” three times with 30 seconds left, then “chirps” three times again with 3
seconds left before it shuts itself off.
Multi-Item Print
The EL-3000 comes standard with a feature called “Multi-item Print”. This allows the user to have a
printout of each weighment transaction plus the total. To enable this feature, select “1” for A4 in the
User Menu and plug a serial printer into the DB-9 connector on the back of the scale. You may also
need to alter the serial parameters A1 and A2 in order to match the printer’s requirements.
Shown at right is an example of the multi-item
print function. Each weighment is printed when the
Here are a few notes for those users who ordered the Battery Operation option for the EL-3000:
Before using the scale for the first time, please charge the scale overnight.
The scale’s battery should operate for about 10 hours if left on continuously. Therefore, greater
usage times can be achieved by selecting an appropriate Auto Power Off Period under A5 of the
User Menu.
The scale can be charged while ON or OFF and can be operated while charging.
To charge the internal battery:
1. Connect the charger (AC Adapter 15 VDC, 800mA) to the scale , then plug the charger into an AC
outlet.
2. After the charging period expires, unplug the charger from the AC outlet, then from the scale. The
scale is now ready for use under its own battery power. If the scale is not allowed for charge for the
full recommended time period, you may notice a decline in the usage period. This is due to the battery’s reluctance to accept a charge. Therefore, always charge the scale for at least 10 hours before using.
3. The charger may be left connected to the scale indefinitely without damage to the internal battery.
When to charge the internal battery:
1. When the scale needs to be charged, the Low Battery Indicator will appear in the lower right-hand
corner of the display. The scale may be used for an additional 15 to 30 minutes without damage to
the internal battery. If the scale is used for more than 30 minutes after a low battery
indication, permanent damage may occur to the battery and/or the battery may not accept a
charge.
2. With the sealed lead-acid type battery, it is OK to charge the battery at any time to keep the battery
“fresh”. You do not necessarily have to wait for the Low Battery Indication.
When a low battery indication occurs, the scale automatically shuts off after 5 minutes if the
NOTE:
scale is idle. The period selected for Auto Power Off Period (A5) is not altered.
EL 3000 Operating Manual
9
Page 12
Calibration
The EL-3000 scale may be calibrated with any precision test weight from 10% to 100% of full scale
capacity. If the scale was ordered in a avoirdupois configuration, the test weight unit must be in pounds.
If the scale was ordered in a metric configuration, then the test weight unit must be in kilograms. The
recommended test weight is about 2/3 of the full scale capacity, but in general, the larger the test
weight, the more accurate the scale will be.
CALIBRATION MODE KEY FUNCTIONS
MR
M+
SAMPLE
SET
MODE
ZERO
CLEAR
To calibrate the scale:
Turn the scale off. While pressing and holding down the
1.
The message "
" appears on the display briefly, followed by a value which remains on the screen.
C 0
ZERO/CLEAR
Allow a 20 minute warm-up period for the load cell and indicator to become thermally stable.
key, turn the scale back on.
Press
2.
3.
ZERO/CLEAR
The display will momentarily prompt "
“0.0000”
depending on the scale capacity. The rightmost digit should be flashing. Place the test
weight on the platform.
Use the four directional keys shown above to adjust the displayed value to the actual test weight
4.
to zero the value, then press the
" for the span calibration, followed by "
C 1
SAMPLE
key to save the zero point value.
",
0.00
“0.000”,
or
value. Increase the flashing digit by pressing the MR key. Decrease the flashing digit by pressing the
key. The position of the flashing digit may be changed by pressing the
M+
key.
MODE
5. After setting the exact value and letting the scale stabilize, press the
ZERO/CLEAR
SAMPLE
key or the
key to save the
value.
If the calibration was successful, the display will show "
6.
" then freeze. Exit the Calibration mode
ECAL
and enter the Normal Operating Mode by turning off the scale, then turning it back on with no keys
held down.
7. If the calibration was not successful, one of the error messages below will appear. Take the indi-
cated action to correct the problem, then perform a new calibration.
"Err0"
- The calibration test weight or the adjusted keyed-in weight is larger than full scale. Change
the calibration test weight or check the keyed-in weight.
"Err1"
- The calibration test weight or the adjusted keyed-in weight is smaller than 10% of full scale.
Change the calibration test weight or check the keyed-in weight.
"Err2"
- Check keyed-in weight with the actual weight placed on platform.
Revision 2.95
10
Page 13
Serial Data Formats
Full Duplex Overview:
The EL-3000 is equipped with a full duplex ASCII compatible RS-232C serial communications terminal
wired as a DB-9 type connector mounted on the back of the scale. Full Duplex mode is enabled by selecting “0” for A4 in the User Menu. The data format provides both Continuous and Demand serial
transmission modes, selectable by A3 in the User Menu.
The Continuous mode is used to interface to computers, scoreboards, and other remote devices requiring constant data updating. The transmission occurs at the end of each display update. Primarily designed to interface to printers, the Demand mode allows control from a host device, usually a PC, and
can be activated by pressing the
key on the front panel.
MR
Full Duplex - Continuous Mode
<+/–>
<STX>
Start
Transmission
<LF>
Line
Feed
Polarity:
+ = Positive
– = Negative
XXXX.XXX<UNITS><S1><ETX>
Weight Data
Units:
OZ = ounces
LB = pounds
KG = kilograms
<SPACE>G = grams
<SPACE>% = percent
PC = pieces
Transcell Technology Continuous Format
<G/N>
Gross/Net:
G = Gross
N = Net
Status Character 1:
0 = valid
1 = Under
2 = Over
<LF>
Line
Feed
<S2>
Status Character 2:
0 = valid
1 = Motion
2 = Zero
3 = Motion and Zero
4 = Not Ready
1. Recognized host command(s):
"C" to change displayed units
"Z" to zero the scale
2. Restrictions for transmission: No transmission during Display Check Mode
Will send the "Invalid" format shown below if a) scale is not ready; b) scale is in motion; c) under
zero; or d) over capacity.
"Z" Command
:
Will not respond if the scale is in motion.
Revision 2.95
12
Page 15
Specifications
CONSTRUCTION:
Housing
Base & Sub-Platform
Platform
Feet
DISPLAY:
5½ Character, 7-Segment LCD
: Ivory ABS
: Metal
: Stainless Steel
: Non-skid Hard Rubber
POWER SOURCE:
AC Adapter, 12 VDC, 500mA
OPTIONAL POWER SOURCE:
Internal 12 VDC, 1.2 Ah
rechargeable lead acid battery.
Charger:
Charge Period:
AC Adapter, 15 VDC, 800mA
8-10 hours
KEYPAD:
5-key Tactile Switch
OVER CAPACITY ANNUNCIATION:
103% of Full Scale Capacity
OPERATING TEMPERATURE RANGE:
32°F to 104°F
(0°C to 40°C)
PHYSICAL DIMENSIONS:
8.9in [226mm]
3.4in [85mm]
9.2in [234mm]
Displayed Error Messages
WEIGHT:
Net Weight:
Shipping Weight:
Battery Option:
8.8 lbs (4 kg)
14.2 lb (6.4 kg)
Add 1.2 lb (0.5 kg)
SERIAL PORT:
Full Duplex RS-232 format
8.3in [210mm]
2.9in [72mm]
12.4in [316mm]
Display Message Cause or Condition
– – – – –
Total weight on platform exceeds scale's capacity.
During normal operation, the stainless steel platform was removed, resulting
in an underrange condition. Replace scale platform.
– ///////////////
Scale is negative during sample mode.
EL 3000 Operating Manual
13
Page 16
In Case of Trouble...
After reading your operating manual thoroughly, you should have no trouble using your
scale. However, if you are still experiencing difficulty, please review the following points
before calling or returning the scale.
PROBLEM
#1. Unstable Reading
#2. Does Not Weigh
#3. No Display
XXXXXXXX
PROBLEM:
1. When sample is placed on pan, display
reading will not stabilize, i.e. jumps one
or more divisions.
2. Display will not change after sample is
placed on platform or always shows
overweight condition.
3. No readout appears in the display window.
THINGS TO CHECK:
A. Proper warm-up time is at least 30
minutes. It is recommended that the unit
be left on continuously.
B. Large machinery may cause vibration in
the work area. The scale should be
placed on a stable surface.
C. Excessive air movement can affect
stability. Scale should be located away
from air conditioners, fans, fume hoods,
etc. A breeze shield may be required.
D. Extreme changes in room temperature
can affect the internal calibration of the
unit.
X
E. The sub-platform is held in place by four
screws which may vibrate loose. Remove the platform to check. IMPOR-
TANT: UNPLUG THE AC ADAPTER
FROM THE AC OUTLET PRIOR TO
REMOVING THE PLATFORM. Do not
over tighten screws.
F. Do not place the scale near magnetic
materials or instruments which incorporate magnets in their design.
G. Replace AC Adapter. IMPORTANT:
Replace only with same voltage,
current, and polarity of originally
supplied adapter.
H. The line voltage to the scale should be
reasonably constant and free from fluctuations. It is advisable not to share an
outlet with fluorescent lights or other
products which draw voltage in an inconsistent manner.
I. Calibration memory has been lost. Re-
calibrate scale.
J. A/D converter is not stable or load cell
has failed. Return scale for repair.
X
X
X
Revision 2.95
14
Page 17
Warranty and Service Information
Seller warrants that the EL 3000 Counting Scale will conform to written specifications,
drawings, and other descriptions made by the manufacturer, including any modifications
thereof. The Seller warrants the goods against faulty workmanship and defective materials. If
any goods fail to conform to these warranties, Seller will, as its sole and exclusive liability
hereunder, repair or replace such goods if they are returned within the following warranty
period:
Twelve (12) months from date of shipment from manufacturer.
These warranties are made upon the express condition that:
1) Transcell Technology, Inc. is given prompt written notice upon discovery by Buyer of such
non-conformity, with a detailed explanation of the alleged deficiencies;
2) Such goods are returned to the Seller at the expense of the Buyer;
3) Examination of such goods by Seller discloses that the nonconformity actually exists and was
not caused by accident, misuse, neglect, alteration, improper installation improper or unauthorized repair, or improper testing, and
4) Such goods have not been modified, altered, or changed by any person other than the Seller
or its duly authorized repair agents.
5) Transcell Technology, Inc. will have a reasonable time to repair or replace such goods.
THESE WARRANTIES EXCLUDE ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, ORAL
OR WRITTEN, INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. SELLER WILL NOT IN ANY EVENT BE LIABLE
FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.
IN ACCEPTING THIS WARRANTY, THE PURCHASER OR BUYER AGREES TO WAIVE ANY
AND ALL OTHER CLAIMS FOR RIGHT TO WARRANTY FROM TRANSCELL TECHNOLOGY,
INC. SHOULD THE SELLER BE OTHER THAN TRANSCELL TECHNOLOGY, INC., THE
BUYER AGREES TO LOOK ONLY TO THE SELLER FOR WARRANTY CLAIM OR CLAIMS.
No terms, conditions, understanding, or agreements purporting to modify the terms of this warranty shall have any legal effect unless made in writing and signed by a corporate officer of the
Seller.
EL 3000 Operating Manual
15