Your new thermostat will provide year of reliable service. Using this digital thermostat will provide more uniform comfort in your home through the seasons. Thank you for buying the product! Please read this manual for complete instructions on installing and operating your thermostat. If you require further assistance, please feel free to contact us.
Thermostat
Screws
User Guide
Wall plate
1pc
2pc
1pc
1pc
We offer the warranty of 18 months from the sales day. If it is not the problem of quality or beyond the warranty time, we will charge for the after-sale service.
In the box you will find
Service
About your thermostat
TR-BAC-1000-DX2 series Modern Touch Screen
Room Thermostats are designed to on/off control the compressor in air conditioner applications via comparison of the room temperature and setting temperature as reaching the aim of comfort and saving energy. . TR-BAC-1000-DX2 are microprocessor based thermostat with LCD display.
Features of your thermostat
Modern desgin similar as a cell phone. Beautiful Frame CHROME creates elegant life. Acrylic lenses to avoid the finger scrath. Touch Button makes simple operation. Large screen display with backlight is easy to read—even in the dark. 5+2 four periods program schedules maximize comfort and economy. One-touch temp control overrides program schedule at any time. Precise comfort control keeps temperature within
0.5°C of the level you set. Internal and external sensor selectable is suitable for any place. Data memory when power is off. Easy installation. 86mm hidden box and european 60mm round box is available.
Home screen quick reference
Power On/off
Up
Fan
Mode
Clock
Auto Fan
Timing On/Off
Cooling
Energysaving
Network
Room Temp.
Fan Speed
Manual
Lock
Period
Sleeping
Valve On/off
Down
Set Temp.
Operation
1. Setting the Temperature
a. In the mode of programmable, set temperature, time and timing on/off could not be adjusted. If the user want to change, please reprogram. b. In the mode of manual, press to set temperature. will display in the left corner of screen.
2. Setting Lock (optional function)
Press and hold for 3 sec. to lock the screen. The icon will display on the screen. Press and hold again for 3 sec. to unlock the screen.
Technical Data of your thermostat
SensorNTC Accuracy±0.5 Temp. Range5 -35 Power Consumption<1.5W Timing error<1
Power Supply
AC24V
, 50 ~60Hz
Current Load3A for Compressor, 5A for Fan Shell MaterialPC Fireproof
Dimension86x86x13.3mm
Installation box86*86mm or European 60mm Ambient Temp.0 ~ 45℃,5 ~ 95RH(Non condensing Storage Temp-5~ 55
1 - 5 minutes delay time protection for the
compressor on/off.
Stage
Compressor Control Functional
Mode Control: Troom: Room Temperature Tset: Setting Temperature
When Troom > ( Tset + Deadzone Temp.), the compressor will start operating according to the minumum output on time;
When Troom (Tset ), the compressor will stop
External Sensor
1pc
The deadzone temp. could be set in the item 11 of high senior options. Factory setting is 0 °C.
The minimum output on/off time could be set in the item 10 of high senior options. Factory setting is 3 minutes.
according to the minimum output off time.
Note:
1. When you turn on your thermostats, the compressor will output immediately;
2. The compressor will keep working for 3 minutes ( according to your setting of minimum output on/off time) even if the thermostats have sent signal to operate or stop.
Installing your thermostat
3. Setting the Sleeping
Press and Hold M to set the sleeping. will flash. Press to confirm, to cancel.
6. Setting functions and options
During power off, press and hold at the same time for 5 sec. to system functions. Then press M to change the different items.
All the settings will
confirm automatically
This product is suitable for standard 86mm wall box or european 60mm round box.
1. Connect the wire of power and other equipment into the terminals.
2. Fix the wall plate into the wall box by a screwdriver.
3. Connect the LCD board into the wall plate.
4. Finished.
(Fig 1)
(Fig 2)
(Fig 4)
(Fig 3)
WARNING: Please arrange the professional technician
to install this product according to installation drawing and instruction.
RISK OF ELECTRICAL SHOCK. Disconnect power supply
before making electrical connection. Contact with components carrying hazardous voltage can cause electrical shock and may result in severe personal injury or death.instruction.
4.Selecting manual and programmable
Press and hold , will flash. Press again, M
Press to select manual and press
to select weekly programmable.
5. Adjusting the weekly programmable
Then press M to change the different items.
The order is Minute adjusting→ Hour adjusting → Week adjusting→ Minute timing-on → Hour timing-on→ Minute timing-off→ Hour timing-off→
Temperature adjusting ( “12345”,”6”,”7”, is “5+1+1” programmable mode, every mode has two times zones and a time temperature setting)
Week
First Period Second Period
Turn-on
me
Turn-o
me
Set
temp.
Turn-on
me
Turn-o
me
Set
temp.
Mon. to Fri. 1 2 3 4 5 6
Sat. 7 8 9 10 11 12
Sun. 13 14 15 16 17 18
M
will flash.
Press to set minutes of the time; Press to set hours of the time; Press to set week of the time;
M M
M
Press into the adjustment of programmable.M
After the above steps, press into programmable.M
Press or to set the relative values.
Wiring your thermostat
M
Press or to set the
relative values.
Dimension of your thermostat
86.0
86.0
65.9
48.6 13.2
13.2 29.6
49.6
50.0
50.0
Unit: mm
No Func on Se ng & Op ons Default
1
Temp. Calibra
on
-9to 9 0
2 Fan Control
0:When room temp. reaches
the setpoint, the fan will t urn o.
1:When room temp. reaches
the setpoint, the fan will t urn
to low speed.
0
3 Lock
0:All the bu
ons are locked
except POWER 1 All the bu
ons a re locked
1
4 Heat/Cool
0:Cool only 1:Heat/Cool
0
5 Min. Set Temp. 5-15℃,default is 10 10
6 Max. Set Temp.
5-35℃,default is 30
30
7
Time Display
0:12 hours 1:24 hours
0
8 Display Mode
0Display set temp. only 1Display both set temp. and
room temp.
1
9
10
Minimum O utput
on/off Time
1-5 minutes
3
11
Deadzone
Temperature
0 ~ 5. 0
AC24V +
AC24V-COM
Fan
Valve
AC24V
IP20
M
NTC
Loading...