MAINTENANCE/REPLACEMENT SCHEDULE
Fan ON (Continuous Fan AUTO
Conditions Dusty Normal Dusty Normal
Cleanable 14-30 30-60 30-45 45-90
Pre-Filter Days Days Days Days
Collector Cells 1-2 3 3 6
Months Months Months Months
For maximum efficiency, the air cleaner cells and the pre-filter
should be inspected and cleaned on a regular basis. The Maintenance Schedule is dependent on the amount of air
passing through the filter as well as the amount of dust (pollen,
smoke, etc.) in the air. This schedule shows estimated time
periods and may be increased or decreased based on actual
conditions.
32-5032-03
02/03
Page 2
Congratulations - Your Electronic
Air Cleaner is a modern, economical
indoor pollution fighter. You should notice a marked improvement in your indoor
atmosphere as your Electronic Air Cleaner begins removing those tiny airborne pollution particles, such as dust, pollen, and smoke from the air in your home.
Home Care
Keeping your home furnishings clean is easier when the air is clean. Most of the
dust and grime you must remove is drifting in the air. With your Electronic Air Cleaner
operating in your home's environmental system, walls, windows, mirrors, draper- ies, and furniture stay cleaner longer. You should have a reduction in the soiling
effect of these pollution particles on your home furnishings.
Most staining and soiling problems are caused by these minute particles. These particles are so tiny that they are only slightly affected by gravity, and can stick as easily to a walt as to the floor. The
soiling of fabrics and the dull film on mirrors and windows are caused by these tiny particles. With your Electronic Air Cleaner operating, you should not have to
clean them as often as before.
A small percentage of the larger visible
particles in your home, such as large dust and lint, are too heavy to stay adrift long enough to be returned to the Electronic Air Cleaner. They settle out on horizontal surfaces and will have to be picked up by
dusting as before, though perhaps not quite so often. These visible dust particles represent a small percentage of all the drifting particles in your home.
Smoke
Smoke is comprised of submicroscopic particles. Collectively, these particles make up the familiar blue haze we all know. In dense concentration the particles form layers and can stay suspended on
the air currents for hours. These particles wilt eventually settle out as a dulling film
on mirrors and windows. Your Electronic Air Cleaner can remove nearly all of these
particles before they have a chance to soil your home and its furnishings.
Pollen
Pollens are also drifting particles, some which can be seen, but many are invisible to the eye. Your Electronic Air Cleaner
removes almost all of the pollen particles circulated to it.
How the Electronic Air Cleaner Works.
Air Cleaner -_
Cabinet
Electronic Cell
Figure 1. Electronic Air Cleaner Cabinet with 1" Pre-Filter
Components
A. The cabinet is installed into the return
ductwork of your air conditioning system.
B. The Power Door located on the front of
the Cabinet, contains the electronic
components that provide power for the
Air Cleaner and allows the removal of the Electronic Cells and Pre-filter when
Pre-Filter "_
cleaning is required. The On/Off switch and indicator light are located on the front panel of the Power Pack. The power cord plugs into the receptacle
below the ON/OFF switch.
C. The Pre-fitter catches large dust
particles and lint before they reach the
Electronic Cells.
Electronic Cell
j Power Door
Power Pack
1/4 Turn Latch
4e--"_ (Lock Position)
1/4 Turn Latch
(Unlock Position)
D, The Electronic Cells contain the
ionizing grids and collecting plates which electronically remove the dirt, pollen, and smoke particles from the air passing through them.
Page 2
Page 3
How It Works
The air in your home is circulated through your heating and/or cooling system, maintaining the temperature at a comfort- able level. At the same time, the circulated return air is passing through the Electronic
Air Cleaner. Millions of small dirt particles such as smoke and pollen, most of them so small as to be invisible, are carried by the returning air to the Electronic Air
Cleaner. To familiarize you with the operation of the
Electronic Air Cleaner, here is a brief description of how "drift-dirt" is removed from the air electronically,
1, Drift particles in your home are carried
to the Air Cleaner through the return air ductwork of your conditioning air system,
2, Lint, feathers, animal hair, and other
large particles are trapped by the pre-
filter,
3, Most of the drifting particles are too
small to be captured by the pre-fitter
and pass into the ionizing field of the Electronic Cells where they are
electrically charged,
4. As the air carries these charged particles into the collector section of the Electronic Cells, they are magneti- cally drawn against metal plates by the action of the powerful electrical field.
This process is comparable to a
magnet attracting iron filings.
5. These particles cling to the metal plates and the now filtered air passes on to the fan compartment of your
conditioning air system before being recirculated through your house.
Dirty Air In Pre- ilter i,F _,
// ! / 1/" / /_ \
A,
/-\_
\ / _ // \ I -_-
/. -- j
-qL.: \/ J....I
_- --- I /// \
Ionizing Wires
6. As additional "drifting dirt" particles are generated in your home, or infiltrated from outdoors, they are also carried to the Electronic Air Cleaner where they
are collected.
7. Because particles collected on the cells are so small, the cells may not appear dirty. The cells should be cleaned according to the maintenance
schedule.
Ionizing Section
_/ , i Collecting Section
Electronic Cell
Clean Air Out
\
Collecting Plates
Electronic Air Cleaner
Fan & Filter Operation
Your Air Cleaner only operates when air is circulating through the unit; consequently,
it operates only when the furnace or air conditioner fan operates. Your Air Cleaner can do more for you if the fan operates continuously. Most thermostats have a
switch that wilt permit continuous fan operation. However, it must be understood that continuous fan operation will increase operating expense somewhat.
On/Off Switch & Indicator Light
Your Electronic Air Cleaner has an air flow sensor that wilt provide power to the
electronic cells when your conditioning air system fan is on. For fully automatic operation, just turn the switch on the front
of the Power Pack "ON". The Air Cleaner will be on whenever the fan runs.
Indicator Lights
Your Electronic Air Cleaner has a green light on the front of the power pack that will be ON when the Electronic Air Cleaner is
operating. This light should be ON
whenever the fan is running and the switch
is turned "ON'. If the fan stops running, or power to the Air Cleaner has been
disrupted, the light wilt go out and remain off until the power has been reapplied.
Operation
1. With power turned on at the circuit
2. With the blower running, the green light
3. When the blower stops, the green light
Operation.
breaker and the system blower off, push the air cleaner ON-OFF switch to the "ON" position. The green light wilt turn ON for approximately ten seconds,
then turn OFF.
will be ON to indicate that the air cleaner is operating. An arcing or
"snapping" sound may be heard occasionally. This is normal, and the unit is operating properly.
will turn OFF.
Arcing (Snapping Or Popping)
Do not be concerned if the Air Cleaner snaps or pops intermittently. These
sounds are caused by large particles entering the cleaner. Should this continue to the point of irritation, clean the pre-fitter if dirty and remove the Electronic Cells
and clean them according to the direc- tions. Arcing (snapping and popping) may
also occur when an Electronic Celt is still wet after washing or when it is very dirty.
An increase in the frequency of the snapping noise may indicate that the cells
need cleaning. If Arcing Persists When
the Cells are Clean And Dry, Consult Your Installing Or Servicing Contractor.
Page 3
Page 4
Simple Maintenance Procedures.
Cleaning The Electronic Cells
For peak efficiency, the Electronic Cells in your Air Cleaner should be washed regularly (between one and six months). This is necessary to remove the deposits of dirt particles collected while running.
Experience will be the best indicator of how often the cells should be washed.
Removing The Electronic Cells And Pre-filter
To reduce the risk of
electrical shock, disconnect power to the Air Cleaner before perform- ing maintenance or service.
1. At the thermostat, place the system switch to OFF and the fan switch to
AUTO to assure that the air system will
not turn on while cleaning.
2. Push the Electronic Air Cleaner power switch to the "OFF" position. Unplug
power cord at the walt before removing the Electronic Cells. If you are not familiar with this equipment, contact
your installer or dealer.
High voltage is present within the air cleaner for operation. Before removing the power door, wait at least 15 sec- onds to allow the power pack and electronic cells to discharge.
3. Turn the latches on the power door 1/4 turn (open position) to unlock and
remove the power door.
4. Remove the Pre-fitter.
5. Slide the Electronic Cells out.
Soaking The dirt on the Electronic Cells can be
removed by soaking in a strong solution of dishwasher detergent.
1. Use a container large enough to hold the Electronic Cells, such as a large
plastic dishpan, trash container, or laundry tub.
2. Use an automatic dishwasher deter- gent in hot water. All major brands
worked welt in tests.
NOTE: Depending on the minerals in the
water in your area, some brands of dishwasher detergent may form a
precipitate of scum. If a noticeable
scum floats to the surface, try another brand of detergent.
3. Pour into the container about 3/4 cup of detergent per celt. A bit more if the
container is much larger than the cell. Pour in enough very hot water to cover the cells.
Page 4
4.
After the detergent has completely dissolved, put the cells into soak.
5.
Soak the cells and pre-filter for 15 to 20
minutes; slosh up and down, or around
several times, and remove.
Be careful not to scald
hands and arms when using very hot water.
6.
Rinse the cells and pre-filter with a fine
lower pressure spray.
7. Soak the cells (only) in clean hot water for another 5 to 15 minutes.
8. Remove the cells and let drain for 15 to 20 minutes. If the water draining from
the cells feels slippery, the cells need
more rinsing.
9. Inspect the cells for cleanliness. If any dirt remains, repeat the washing procedure until clean.
10. Replace the cells and pre-filter into the Air Cleaner when dry.
NOTE: If washing must be repeated, this is
an indication that washing should be
performed more frequently.
Replacing The Electronic Cells And Pre-filter
NOTE: A guide key in the Air Cleaner
cabinet will allow the Electronic Cells to fit into the cabinet in only one position -
with the arrow pointing in the direction of airflow.
1. Position cells correctly and slide them
into place.
2. Insert the Pre-filter in the channel provided for it.
3. Replace the power door. Turn the latches 1/4 turn to secure the door.
4. Restore all power previously discon- nected - See Item #2 under Removing
The Electronic Cells And Pre-filter
5. Push the Electronic Air Cleaner switch to the "ON" position.
Cleaning The Air Flow Switch
During normal maintenance, the air flow sensor tube may require cleaning to
remove any accumulated dirt and dust. To clean the tube, gently push a soft pipe
cleaner into the tube above and below the printed circuit board. Gently blow into the
tube to remove loosened dirt.
Clean above and
board in air flow
tube.
Cleaning the Ionizing Wires
Ionizing wires may become coated
causing toss of cleaning ability by the collecting celt and should be cleaned, at
least, annually. The thin ionizing wires are sharp and
fragile. Use care when wiping the wires with the pencil eraser to avoid personal injury or broken wires. If an Ionizing wire breaks, refer to "Replacing An Ionizing
Wire". Using a pencil eraser, wipe each ionizing
wire, exercising care to avoid damage to them.
Ionizing_
Pencil
_ Eraser
_'_ -_ID,._ Ionizing
0 Wire
Page 5
Replacing An Ionizing Wire
If an ionizing wire should break, itcan be
replaced as follows:
1. Remove all pieces of broken wire. Make sure supports at each end are in
good condition and not bent out of shape.
2. Hook the new wire onto the support at one end.
3. Hold your finger against the support at the other end and hold the ionizing wire between thumb and forefinger as shown or use needle nose pliers. Press on spring and on wire loop until itslips
over the end of the support. Make sure wire issecurely anchored at each end.
Support
Wire
TROUBLESHOOTING
INDICATION SERVICE CHECKS ACTION
On/Off switch "ON" None Normal Standby Operation.
Green light "OFF"
Blower Off
On/Off switch "ON" None Normal Operation.
Green light "ON"
Blower On
Green light "OFF"
Blower On
On/Off Switch "ON"
Green light flickering
Blower On
AC Power is On/Off switch "ON"
1. Check that power cord is properly connected to
2. Check for voltage at air cleaner outlet box. If
3. Check that fuse in power pack is not blown
4. Check for shorted collecting celt by installing
5. Check for dirt or blockage in air sensor tube.
6. Check that pre-filter is installed and not
1. Check for dirty collecting cells. Check cells for any foreign object that might be lodged between plates
of celt.
2. Check cells for broken ionizing wires, cracked
insulator, or bent plates.
3,
All ionizing wires must be completely clean with no
dust build-up on wires.
not being supplied to air cleaner.
power pack and to outlet.
none, check fuse or circuit breaker at power input line.
power door with collecting cells removed and only pre-fitter installed. If green light turns "ON"
celt is shorted.
damaged.
1. Make proper power cord connections.
2. Replace fuse or reset circuit breaker.
3. Replace Fuse.
4. Wash cells. If short is not corrected, call for service.
5. Clean air sensor tube.
6. Replace damaged filter
1. Remove cells and wash thoroughly.
2. Replace broken ionizing wires. Replace celt if insulator cracked or plates bent.
3. Clean ionizing wires.
Page 5
Page 6
LIM ITED WARRANTY
ELECTRONIC AIR CLEANER
*FE
(PARTS ONLY)
This limited warranty isextended byAmerican Standard Inc., tothe original purchaser and to any succeeding owner of the real property to which the ElectronicAir Cleaner is originally affixed, and applies to products purchased and retained
for use within the U.S.A. and Canada.
Ifany part of your ElectronicAir Cleaner fails because of a manufacturing defect within five years from the date of the original purchase, Warrantor will furnishwithout charge the required replacement part. Any local transportation, related service labor, mechanical filters and diagnosis calls are not included.
This limited warranty does not cover failure ofyour ElectronicAir Cleaner if itis damaged while in your possession, damage caused by unreasonable use of the Electronic Air Cleaner and/or damage from failure to properly maintain
the ElectronicAir Cleaner as set forth in the Useand Care manual (see Proper Maintenance section). This limited warranty applies to product installed on or after 10/1/2001 where product is manufactured after 1/1/2000.
This limited warranty is not retroactive to any installations pdorto 10/1/2001 or on product produced before 2000.
THE LIMITED WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILITIES, WHETHER IN CONTRACT OR IN NEGLIGENCE, EXPRESS
OR IMPLIED, IN LAW OR IN FACT, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR USE, AND IN NO EVENT SHALL
WARRANTOR BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do notallow limitations on how long an implied limited warranty lastsor do not allow the exclusion or limitation of incidental or consequential damages, so the above limitationor exclusion may not apply toyou. This limited
warranty gives you specific legal rights,and you may also have other rights which vary from state to state. Parts will be provided byour factory organization through an authorized service organization in your area listed inthe
Yellow Pages. Ifyou wish further help or information concerning this limited warranty, contact: American Standard Inc.
TroupHighway Tyler,TX 75711-9010