TDX060,080,100,120R-V
Direct Vent with Variable Speed Inducer
PUB. NO. 22-1706-01-0400 (EN)
Page 2
General
Features
Natural Gas Models
Central heating furnace designs are
certified by the American Gas Association
for both natural and L.P. gas. Limit setting
and rating data were established and
approved under standard rating
conditions using American National
Standards Institute standards.
Safe Operation
The Integrated System Control has solid
state devices, which continuously monitor
for presence of flame, when the system
is in the heating mode of operation. Dual
solenoid combination gas valve and
regulator provide extra safety.
Quick Heating
Durable, cycle tested, heavy gauge
aluminized steel heat exchanger
quickly transfers heat to provide warm
conditioned air to the structure. Lowenergy power vent blower, to increase
efficiency and provide a positive discharge of gas fumes to the outside.
Burners
Multi-port In-shot burners will give years
of quiet and efficient service. All models
can be converted to L.P. gas without
changing burners.
Integrated System Control
Exclusively designed operational
program provides total control of furnace
limit sensors, blowers, gas valve, flame
control and includes self diagnostics for
ease of service. Also contains connection points for E.A.C./humidifier.
Condensate Drain
Built-in trap which can drain from either
side when the furnace is installed upflow.
Air Delivery
The variable speed, direct drive blower
motor, has sufficient airflow for most
heating and cooling requirements, will
switch from heating to cooling speeds on
demand from room thermostat. The
blower door safety switch will prevent or
terminate furnace operation when the
blower door is removed.
Secondary Heat Exchanger
The XL 90 has a special type 29-4C™
stainless steel secondary heat exchanger to reclaim heat from flue gases
which would normally be lost outside.
Styling
Heavy gauge steel and “wrap-around”
cabinet construction is used in the
cabinet with baked-on enamel finish for
strength and beauty. The heat exchanger
section of the cabinet is completely lined
with foil faced fiberglass insulation. This
results in quiet and efficient operation
due to the excellent acoustical and
insulating qualities of fiberglass. Built-in
bottom pan and alternate bottom, left or
right side return air connection provision.
Features And General Operation
The XL 90 High Efficiency Gas Furnaces
employ an Adaptive Silicon Nitride Hot
Surface Ignition system, which eliminates the waste of a constant burning
pilot. The integrated system control lights
the main burners upon a demand for
heat from the room thermostat. Complete
front service access.
a. Low energy power venter.
b. Vent proving pressure switch.
Thermostat, Mechanical Heating Only With Fan Switch........................................................................................... BAYSTAT303 [ ]
Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ............................................................................... AY28X092 [ ]
Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ............................................................................... BAYSTAT305 [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (17-1/2" Wide Gas Furnace) ..................................................... TFE175A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (21" Wide Gas Furnace) ........................................................... TFE210A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (24-1/2" Wide Gas Furnace) ..................................................... TFE245A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .......................................................TFM175A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ............................................................. TFM210A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .......................................................TFM245A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ................................................ TFP175A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ...................................................... TFP210A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ................................................ TFP245A9FR0 [ ]
1 Central Furnace heating designs are certified by the American Gas Association Inc. Laboratories.
2 Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
3 Based on U.S. Government Standard Tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
2
1st Stage Capacity BTUH (ICS)
2nd Stage Capacity BTUH (ICS)
-Unfired
4
TDX060R936V
39000
3
3
ALUMINIZED STEEL TYPE 1
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
SEE OUTLINE DRAWING
SEE OUTLINE DRAWING
36000
60000
55000
92.0
35 - 65
DIRECT
10 x 8
1
4
SEE FAN PERF. TABLE
1/3
1075
115/1/60
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
115/1/60
1.1
YES
HIGH VELOCITY
2 - 14 X 20 X 1
2 ROUND
20
3 - 45
3 - 56
IN-SHOT
4
115/1/60
9.1
15
0.50
H X W X D
41-3/4 X 19-1/2 X 30-1/2
155/145
TDX080R942V
52000
48000
80000
74000
92.5
35 - 65
DIRECT
11 x 8
1
4
SEE FAN PERF. TABLE
1/2
1075
115/1/60
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
115/1/60
1.1
YES
HIGH VELOCITY
2 - 14 X 20 X 1
2 ROUND
ALUMINIZED STEEL TYPE 1
20
4 - 45
4 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT
4
115/1/60
11.4
15
0.50
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 19-1/2 X 30-1/2
SEE OUTLINE DRAWING
168/158
TDX100R948V
65000
60000
100000
93000
93.0
45 - 75
DIRECT
11 x 10
1
4
SEE FAN PERF. TABLE
1/2
1075
115/1/60
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
115/1/60
1.1
YES
HIGH VELOCITY
2 - 16 X 20 X 1
2 ROUND
ALUMINIZED STEEL TYPE 1
20
5 - 45
5 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT
5
115/1/60
12.5
15
0.50
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 23 X 30-1/2
SEE OUTLINE DRAWING
185/175
TDX120R960V
78000
72000
120000
111000
92.5
45 - 75
DIRECT
11 x 10
1
4
SEE FAN PERF. TABLE
3/4
1075
115/1/60
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
115/1/60
1.1
YES
HIGH VELOCITY
2 - 16 X 20 X 1
3 ROUND
ALUMINIZED STEEL TYPE 1
20
6 - 45
6 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT
6
115/1/60
12.9
15
0.50
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 26-1/2 X 30-1/2
SEE OUTLINE DRAWING
206/196
622-1706-01-0400 (EN)
Page 7
Performance
Data
TDX-R-V
FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.)
1. Minimum vent length for all models: 3' horizontal and vertical.
2. DO NOT MIX PIPE DIAMETERS IN THE SAME LENGTH OF PIPE OUTSIDE THE FURNACE CABINET (Except adapters at
the top of the furnace).
3. MAXIMUM PIPE LENGTHS MUST NOT BE EXCEEDED! THE LENGTH SHOWN IS NOT A COMBINED TOTAL, IT IS THE
MAXIMUM LENGTH OF EACH (Vent or Inlet air pipes).
4. One SHORT radius 90° elbow is equivalent to 10' of 3" pipe and one LONG radius elbow is equivalent to 6' of 3" pipe. One
90° elbow is equivalent to 7½' of 2½" pipe or 5' of 2" pipe. Two 45° elbows equal one 90°elbow.
5. The termination tee or bend must be included in the total number of elbows. If the BAYVENT100A termination kit is used, the
equivalent length of pipe is 5 feet. BAYVENT200A/B equivalent length is 0 feet.
6. Pipe adapters are field supplied (except 120).
822-1706-01-0400 (EN)
Page 9
Electrical
Data
SCHEMATIC DIAGRAMS FOR GAS FURNACES
LEGEND
TDX060,080,100,120R-V
22-1706-01-0400 (EN)9
From Dwg. 21D341250 P02
Page 10
Field
Wiring
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING
From Dwg. 21B341333 Rev. 0
FIELD WIRING DIAGRAM FOR 2 STAGE HEATING THERMOSTAT
From Dwg. 21B341332 Rev. 0
1022-1706-01-0400 (EN)
Page 11
Field
Wiring
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING
(OUTDOOR SECTION WITHOUT TRANSFORMER)
From Dwg. 21B341335 Rev. 0
FIELD WIRING DIAGRAM FOR 2 STAGE HEATING SINGLE STAGE COOLING
1. TDX100R960V requires 2-1/2" or 3" and TDX120R960V
requires a 3" diameter vent pipe.
2. Clearance required at top of plenum is 1"
From Dwg. 21C340762 Rev. 3
1422-1706-01-0400 (EN)
Page 15
Notes
22-1706-01-0400 (EN)15
Page 16
The Trane Company
Unitary Products Group
6200 Troup Highway
Tyler, TX 75707-9010
www.trane.com
An American Standard Company
P.I.
Since The Trane Company has a policy of continuous product and product data improvement, it reserves the
right to change design and specifications without notice.