Trane TUHMB060ACV3VB, TDHMB060BCV3VB, TUHMB080ACV3VB, TUHMC100ACV4VB, TDHMC100ACV4VB User Manual

...
Page 1
Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace
XC 95m
TUHMB060ACV3VB, TDHMB060BCV3VB TUHMB080ACV3VB, TDHMB080ACV3VB TUHMC100ACV4VB, TDHMC100ACV4VB TUHMD120ACV5VB, TDHMD120BCV5VB Direct or Non-Direct Vent with Variable Speed Blower Variable Speed Inducer
UPFLOW
UPFLOW/HORIZONTAL
DOWNFLOW
DOWNFLOW/HORIZONTAL
PUB. NO. 22-1840-14
Page 2
General Features
MODULATING OPERATION
The modulating gas valves provides longer heating cycles for more consistent heating comfort. Modulates from 40% (45% for the TUHMD120) to 100% in less than 1% increments of the furnace's heating capacity saving energy, while at the same time maximizing homeowner comfort.
COMMUNICATING MODE
Furnace is shipped ready to be connected in communicating mode using three wire hook-up using the TZONE950 or the TCONT900 comfort control.
ALTERNATE 24V MODE
Furnace is field configurable to 24V non-communicating mode.
COMFORT CONTROL
Comfortlink IITM Communicating furnace design, offers plug and play – walk away installation. Assures the entire heating and air conditioning system is set up in the proper modes to optimize the engineered performance of the matched system installed. The furnace can also be connected in conventional 24V mode.
NATURAL GAS MODELS
Central Heating furnace designs are cer­tified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and ap­proved under standard rating conditions using American National Standards Insti­tute standards.
SAFE OPERATION
The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and reg­ulator provide additional safety.
QUICK HEATING Durable, cycle tested, heavy gauge alu­minized steel heat exchanger quickly
transfers heat to provide warm condi­tioned air to the structure. Low energy power vent blower, to increase efficien­cy and provide a positive discharge of gas fumes to the outside.
BURNERS
Multiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without chang- ing burners.
INTEGRATED SYSTEM CONTROL
Exclusively designed operational pro­gram provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for EAC and Humidifier hookup.
AIR DELIVERY
The variable speed blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed.
SECONDARY HEAT EXCHANGER
The XC95m has a special type 29-4C™ stainless steel secondary heat exchang­er to reclaim heat from flue gases which would normally be lost.
STYLING Heavy gauge steel and “wrap-around” cabinet construction is used in the
cabinet with baked-on enamel finish for strength and beauty. The heat exchang­er section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient opera­tion due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection provision.
FEATURES AND GENERAL OPERATION
The XC95m High Efficiency Gas Fur­naces utilize an Adaptive Heat Up Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burn­ing pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Com­plete front service access. a. Low energy power venter b. Vent proving pressure switch.
© 2015 Trane All Rights Reserved
2
Pub. No. 22-1840-14
Page 3
Contents
General Features 2 Features and Benefits 4
Standard Equipment 4 Optional Equipment 5
General Data 6-7
TUHMB060ACV3VB 6 TUHMB080ACV3VB 6 TUHMC100ACV4VB 6 TUHMD120ACV5VB 6 TDHMB060BCV3VB 7 TDHMB080ACV3VB 7 TDHMC100ACV4VB 7 TDHMD120BCV5VB 7
Performance Data 8-19 Venting Tables 20 Electrical Data 21-24 Field Wiring 25-28 Dimensions 29-30
Pub. No. 22-1840-14
3
Page 4
Features and Benefits
XC95m STANDARD EQUIPMENT
•Comfortlink IITM Communication
or 24 Volt control
•Factorydefaultiscommunication
mode
•Fieldcongurableto24volt
non-communicating mode
•Communicationrequirescomfort
control TZONE950 or TCONT900
•Plugandplayinstallationincom­munication mode with communi­cating comfort control
•Threewireconnectionstocomfort
control when used with communi­cating comfort control (TZONE950 or TCONT900)
•Furnacemodulatesfrom40%
(45% for the TUHM1D120) to 100% of its heating capacity
•UpowmodelsconvertibletoHori­zontal Left
•Downowmodelsconvertibleto
Horizontal Right
•Powersupply115/1/60
•Modulatinggasvalve
•VariablespeedECMblowermotor
with Comfort R
•Variablespeedinduceddraft
blower
•SiliconNitridehotsurfaceigniter
with adaptive heat up
•PVCVenting-1or2pipeoption
•Integratedsolidstatecontrolwith
self-diagnostics
•Furnacecertiedtoleak2%or
less of nominal air conditioning CFM delivered when pressurized to .5” water column with all inlets, outlets, and drains sealed
TM
•Storedfaultcodehistoryinmicropro­cessor nonvolatile memory
•Insulatedblowerdoor
•Gasketedblowerdoor
•Attractivecoloraccents
•Heavygaugealuminizedsteelheat
exchanger
•Multi-portIn-shotburners
•Completefrontserviceaccess
•Slideoutblowerassembly
•Direct/Non-directVentOption
•OptionalL.Pconversionkit
•ImprovedCleanEffectsTM connec-
tions
•Left/rightgasconnection
•Accessoryhook-upcapability
•Manualresetamerolloutswitch-
es
•Cleanablehighvelocitylters
•Hingedblowerdoor*
•Perfecttdoorlatches*
Optional extended warranties
*(Upowonly)
4
Pub. No. 22-1840-14
Page 5
Features and Benefits
XC95m OPTIONAL EQUIPMENT
Comfort Control XL950, Communicating ....................................................................................................... TZONE950AC52ZA [ ]
Comfort Control XL900, Communicating .......................................................................................................TCONT900AC43UA [ ]
Comfort Control XL802 Programmable 7 Day, 3-Ht, 2-Cl .............................................................................. TCONT802AS32DA [ ]
Comfort Control XL803 Programmable 7 Day, 3-Ht, 2-Cl with dehumidification ............................................TCONT803AS32DA [ ]
Propane Conversion Kit ........................................................................................................................................ BAYLPKT220B [ ]
Propane Conversion Kit (with stainless steel burners) ......................................................................................... BAYLPSS220B [ ]
5"ExpandableHighEfciencyMediaAirFilter,“PerfectFit”(17-1/2"WideGasFurnace) .................................. TFM175A9FR0 [ ]
5"ExpandableHighEfciencyMediaAirFilter,“PerfectFit”(21"WideGasFurnace) ......................................... TFM210A9FR0 [ ]
5"ExpandableHighEfciencyMediaAirFilter,“PerfectFit”(24-1/2"WideGasFurnace) .................................. TFM245A9FR0 [ ]
1"ExpandableStandardEfciencyMediaAirFilter,“PerfectFit”(17-1/2"WideGasFurnace) ............................TFP175A9FR0 [ ]
1"ExpandableStandardEfciencyMediaAirFilter,“PerfectFit”(21"WideGasFurnace) ..................................TFP210A9FR0 [ ]
1"ExpandableStandardEfciencyMediaAirFilter,“PerfectFit”(24-1/2"WideGasFurnace) ............................TFP245A9FR0 [ ]
CoilEnclosure(17-1/2"WideCabinets) .......................................................................................................BAYCLE17A1722A [ ]
CoilEnclosure(21"WideCabinets) ..............................................................................................................BAYCLE21A2130A [ ]
CoilEnclosure(24-1/2"WideCabinets) .......................................................................................................BAYCLE24A2430A [ ]
Downflow Subbase ................................................................................................................................................. BAYBASE205 [ ]
Side Filter Rack ..................................................................................................................................................... BAYFLTR200 [ ]
Filter Rack Kit - Left & bottom return only for TUHMB060,080,C100. Left, right & bottom returns for TUHMD120 BAYRACK960 [ ]
FilterKit/HorizontalConversionTUHMB060,080..................................................................................................... BAYFLTR203 [ ]
FilterKit/HorizontalConversionTUHMC100 ........................................................................................................... BAYFLTR204 [ ]
FilterKit/HorizontalConversionTUHMD120 ........................................................................................................... BAYFLTR205 [ ]
High Altitude Pressure Switch Kit TUHMB060 .............................................................................................BAYSWT07AHALTA[]
High Altitude Pressure Switch Kit TUHMB080,C100 ....................................................................................BAYSWT09AHALTA[]
High Altitude Pressure Switch Kit TUHMD120 .............................................................................................BAYSWT08AHALTA[]
Concentric Vent Kit TUHM Furnaces ..............................................................................................................BAYAIR30AVENTA [ ]
Sidewall Vent Termination Kit All 2 Pipe Direct Vent Furnaces ............................................................................BAYVENT200B [ ]
CleanableFilter(14.5"/17.5"wideUpowmodels) .................................................................................................. BAYFLTR317 [ ]
Cleanable Filter (21" wide Upflow models) .............................................................................................................. BAYFLTR321 [ ]
Cleanable Filter (24.5" wide Upflow models) ........................................................................................................... BAYFLTR324 [ ]
CleanEffects™,WholeHouseAirCleaner(Upow17-1/2"WideGasFurnace) ...........................................TFD175ALFR000B [ ]
CleanEffects™,WholeHouseAirCleaner(Upow21"WideGasFurnace) .................................................. TFD210ALFR000B [ ]
CleanEffects™,WholeHouseAirCleaner(Upow24-1/2"WideGasFurnace) ...........................................TFD245ALFR000B [ ]
CleanEffects™,WholeHouseAirCleaner(Downow17-1/2"WideGasFurnace) ...................................... TFD17DALFR000B [ ]
CleanEffects™,WholeHouseAirCleaner(Downow21"WideGasFurnace) ............................................ TFD21DALFR000B [ ]
CleanEffects™,WholeHouseAirCleaner(Downow24-1/2"WideGasFurnace) ...................................... TFD24DALFR000B [ ]
CleanEffects™,WholeHouseTransformerKit(120to24Volt-allTFDAirCleaners) ..................................... BAYTRANS12024 [ ]
CleanEffects™ Connection Kit for Modulating Furnace ...............................................................................BAYACCECOMM100 [ ]
Pub. No. 22-1840-14
5
Page 6
General Data
TUHM PRODUCT SPECIFICATIONS1
MODEL
TYPE RATINGS 2
40% (low) heat Input BTUH 40% (low) heat Capacity BTUH (ICS) 36 100% (high) heat Input BTUH 100% (high) heat Capacity BTUH (ICS) 3 Temp. rise (Min.-Max.) °F. AFUE
BLOWER DRIVE
Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz FLA
COMBUSTION FAN - Type
Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA
FILTER — Furnished?
Type Recommended Hi Vel. (No.-Size-Thk.)
VENT Size Min. (in.)
HEAT EXCHANGER
Type -Fired
-Unfired Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size L.P. Gas Qty. — Drill Size 5
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps) Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
TUHMB060ACV3VB 7
Upflow/ Horizontal Left
24,000 23,352 60,000 58,380 35 - 65
97.3
DIRECT
10 x 8
1
Variable
See Fan Performance Table
1/2 Variable 115/1/60
5.2 - 6.2 8
Centrifugal
Direct - Variable
1/50 - 5000
115/3/60
1.0
Ye s
High Velocity
1 - 17x25 - 1 in.
2 Round
Aluminized Steel - Type I
20
3 — 45 3 — 56
Redundant - Three Stage
Hot Surface Igniter
Multiport Inshot
3
115/1/60
8.8 15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
158 / 146
TUHMB080ACV3VB 7
Upflow/ Horizontal Left
32,000 30,944 80,000 77,360 35 - 65
96.7
DIRECT
10 x 8
1
Variable
See Fan Performance Table
1/2 Variable 115/1/60
5.2 - 6.2 8
Centrifugal
Direct - Variable
1/50 - 5000
115/3/60
1.0
Ye s
High Velocity
1 - 17x25 - 1 in.
2 Round
Aluminized Steel - Type I
20
4 — 45 4 — 56
Redundant - Three Stage
Hot Surface Igniter
Multiport Inshot
4
115/1/60
8.8 15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
168 / 156
TUHMC100ACV4VB
Upflow/ Horizontal Left
40,000 38,400
100,000
96,000 35 - 65
96.0
DIRECT
10 x 10
1
Variable
See Fan Performance Table
1 Variable 115/1/60
7.4
Centrifugal
Direct - Variable
1/50 - 5000
115/3/60
1.0
Ye s
High Velocity
1 - 20x25 - 1 in.
2.5 Round
Aluminized Steel - Type I
20
5 — 45 5 — 56
Redundant - Three Stage
Hot Surface Igniter
Multiport Inshot
5
115/1/60
10.4 15
1/2
H x W x D
41-3/4 x 23 x 30-1/2
197 / 185
TUHMD120ACV5VB 7
Upflow/ Horizontal Left
54,000
52,380 120,000 116,400
40 - 70
97.0
DIRECT
10 x 10
1
Variable
See Fan Performance Table
1
Variable
115/1/60
9.9
Centrifugal
Direct - Variable
1/50 - 5000
115/3/60
1.0
Ye s
High Velocity
1 - 24x25 - 1 in.
3 Round
Aluminized Steel - Type I
20
6 — 45
6 — 56
Redundant - Three Stage
Hot Surface Igniter
Multiport Inshot
6
115/1/60
13.5 15
1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
206 / 193
1 CentralFurnaceheatingdesignsarecertiedtoANSIZ21.47/CSA2.3. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 5 Furnace ships in natural gas configuration. The LP conversion kit used with the modulating furnace is BAYLPSS220B or BAYLPKT220B. 6 45%(low)heatfor*UHM1D120ACV5VB. 7 Energy Star 8 Check motor nameplate for actual FLA
6
Pub. No. 22-1840-14
Page 7
General Data
TDHM PRODUCT SPECIFICATIONS
MODEL
TYPE RATINGS 2
40% (low) heat Input BTUH 40% (low) heat Capacity BTUH (ICS) 3 100% (high) heat Input BTUH 100% (high) heat Capacity BTUH (ICS) 3 Temp. rise (Min.-Max.) °F. AFUE
BLOWER DRIVE
Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz FLA
COMBUSTION FAN - Type
Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA
FILTER — Furnished?
Type Recommended Hi Vel. (No.-Size-Thk.)
VENT Size Min. (in.)
HEAT EXCHANGER
Type -Fired
-Unfired Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size L.P. Gas Qty. — Drill Size 5
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps) Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
TDHMB060BCV3VB 6
Downflow / Horizontal Right
24,000 22,800 60,000 57,000 30 - 60
95.0
DIRECT
10 x 8
1
Variable
See Fan Performance Table
1/2 Variable 115/1/60
5.2
Centrifugal
Direct - Variable
1/50 - 5000
115/3/60
1.0
Ye s
High Velocity
2 - 14x20 - 1 in.
2 Round
Aluminized Steel - Type I
20
3 — 45 3 — 56
Redundant - Three Stage
Hot Surface Igniter
Multiport Inshot
3
115/1/60
7.7 15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
160/ 146
TDHMC080ACV3VB 6
Downflow / Horizontal Right
32,000 30,400 80,000 76,000 35 - 65
96.0
DIRECT
10 x 8
1
Variable
See Fan Performance Table
1/2 Variable 115/1/60
5.2 - 6.2 7
Centrifugal
Direct - Variable
1/50 - 5000
115/3/60
1.0
Ye s
High Velocity
2 - 14x20 - 1 in.
2 Round
Aluminized Steel - Type I
20
4 — 45 4 — 56
Redundant - Three Stage
Hot Surface Igniter
Multiport Inshot
4
115/1/60
8.8 15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
168 / 158
TDHMC100ACV4VB
Downflow / Horizontal Right
40,000 38,400
100,000
96,000 35 - 65
96.0
DIRECT
10 x 10
1
Variable
See Fan Performance Table
3/4
Variable
115/1/60
7.4
Centrifugal
Direct - Variable
1/50 - 5000
115/3/60
1.0
Ye s
High Velocity
2 - 16x20 - 1 in.
2.5 Round
Aluminized Steel - Type I
20
5 — 45 5 — 56
Redundant - Three Stage
Hot Surface Igniter
Multiport Inshot
5
115/1/60
10.4 15
1/2
H x W x D
41-3/4 x 23 x 30-1/2
185 / 175
TDHMD120BCV5VB 6
Downflow / Horizontal Right
48,000
45,600 120,000 114,000
40 - 70
95.0
DIRECT
10 x 10
1
Variable
See Fan Performance Table
1 Variable 115/1/60
9.9
Centrifugal
Direct - Variable
1/50 - 5000
115/3/60
1.0
Ye s
High Velocity
2 - 16x20 - 1 in.
3 Round
Aluminized Steel - Type I
20
6 — 45 6 — 56
Redundant - Three Stage
Hot Surface Igniter
Multiport Inshot
6
115/1/60
13.5 15
1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
206 / 196
1 CentralFurnaceheatingdesignsarecertiedtoANSIZ21.47/CSA2.3. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 5 Furnace ships in natural gas configuration. The LP conversion kit used with the modulating furnace is BAYLPSS220B or BAYLPKT220B. 6 Energy Star 7 Check motor nameplate for actual FLA
Pub. No. 22-1840-14
7
Page 8
TUHM AIRFLOW - HEATING
0.1 0.3 0.5 0.7 0.9
CFM 393 504 512 546 560
Temp. Rise 73 57 56 53 51
Watts 43 81 112 142 140
CFM 435 541 549 580 593
Temp. Rise 66 53 52 50 49
Watts 46 86 119 150 148
CFM 472 573 580 609 621
Temp. Rise 61 50 50 47 46
Watts 50 90 125 159 155
CFM 545 636 644 667 676
Temp. Rise 53 45 45 43 43
Watts 60 103 141 177 169
CFM 565 653 660 682 691
Temp. Rise 68 59 58 57 56
Watts 64 107 145 182 172
CFM 622 703 710 727 734
Temp. Rise 62 55 54 53 53
Watts 75 120 161 199 183
CFM 671 745 752 766 771
Temp. Rise 58 52 51 50 50
Watts 86 133 175 215 192
CFM 769 831 837 843 846
Temp. Rise 50 46 46 46 46
Watts 114 164 210 250 211
CFM 791 849 856 861 862
Temp. Rise 65 61 60 60 60
Watts 121 171 219 258 215
CFM 867 916 922 921 920
Temp. Rise 59 56 56 56 56
Watts 148 201 251 290 230
CFM 932 972 979 973 970
Temp. Rise 55 53 53 53 53
Watts 174 229 282 319 243
CFM 1063 1086 1092 1076 1069
Temp. Rise 48 47 47 48 48
Watts 236 295 353 384 268
100% (high)
Heat
Low
830
Medium Low
900
Medium**
960
High
1080
65%
(medium)
Heat
Low
623
Medium Low
675
Medium**
720
High
810
Medium Low
504
Medium**
538
High
605
Heating
*UHMB060ACV3VB^ Furnace Heating Airflow (CFM) and Power (watts) vs. External Static Pressure With Filter
Airflow Setting
Target Airflow
(See Note 5)
External Static Pressure
40% (low) Heat
Low
465
0.1 0.3 0.5 0.7 0.9
CFM 512 564 581 538 572
Temp. Rise 70 63 62 66 62
Watts 45 77 112 109 146
CFM 586 634 649 606 634
Temp. Rise 61 56 55 59 56
Watts 57 90 129 127 177
CFM 661 704 717 673 696
Temp. Rise 54 51 50 53 51
Watts 71 106 148 146 207
CFM 772 809 819 774 789
Temp. Rise 46 44 44 46 45
Watts 99 136 184 176 253
CFM 757 794 805 760 776
Temp. Rise 67 63 63 66 65
Watts 95 132 179 172 246
CFM 862 893 901 855 864
Temp. Rise 59 56 56 59 58
Watts 127 165 217 202 289
CFM 967 992 997 951 951
Temp. Rise 52 51 51 53 53
Watts 165 205 262 235 332
CFM 1125 1139 1141 1093 1083
Temp. Rise 45 44 44 46 47
Watts 233 276 341 288 395
CFM 1084 1101 1104 1056 1048
Temp. Rise 65 64 63 66 67
Watts 214 256 319 273 379
CFM 1230 1238 1237 1188 1170
Temp. Rise 57 57 57 59 60
Watts 286 331 401 325 437
CFM 1376 1375 1370 1320 1292
Temp. Rise 51 51 51 53 54
Watts 369 418 495 381 496
CFM 1595 1580 1570 1519 1474
Temp. Rise 44 44 45 46 48
Watts 398 470 522 522 529
Target Airflow
(See Note 5)
External Static Pressure
40% (low) Heat
Low
571
Medium Low
643
Medium**
714
High
821
65%
(medium)
Heat
Low
806
Medium Low
907
Medium**
1008
High
1159
Heating
*UHMB080ACV3VB^ Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
Airflow Setting
100% (high)
Heat
Low
1120
Medium Low
1260
Medium**
1400
High
1610
Notes:
1. * First letter may be "A" or "T".
3. ** Factory setting.
2. ^ Letter may be “A” through “Z”.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
6. Target airflow is field selectable for high (100%) heat. Target airflow for low and medium heat are percentages of high heat and are not field selectable.
8
Pub. No. 22-1840-14
Page 9
TUHM AIRFLOW - HEATING
0.1 0.3 0.5 0.7 0.9
CFM 592 617 623 617 606
Temp. Rise 61 59 58 59 60
Watts 78 109 141 173 233
CFM 626 651 655 649 639
Temp. Rise 58 56 55 56 57
Watts 79 110 142 175 236
CFM 660 684 688 682 671
Temp. Rise 55 53 53 53 54
Watts 81 111 144 177 241
CFM 732 755 757 751 739
Temp. Rise 50 48 48 48 49
Watts 87 115 149 185 254
CFM 1048 1065 1060 1052 1038
Temp. Rise 60 59 59 60 61
Watts 149 169 208 252 358
CFM 1107 1123 1116 1108 1094
Temp. Rise 57 56 56 57 58
Watts 167 186 226 271 386
CFM 1165 1181 1173 1165 1150
Temp. Rise 54 53 54 54 55
Watts 187 204 245 292 417
CFM 1291 1304 1293 1284 1269
Temp. Rise 49 48 49 49 50
Watts 236 250 293 343 490
CFM 1466 1476 1461 1451 1435
Temp. Rise 60 59 60 60 61
Watts 319 330 374 430 613
CFM 1548 1556 1540 1529 1512
Temp. Rise 57 56 57 57 58
Watts 364 373 419 476 679
CFM 1629 1637 1618 1608 1590
Temp. Rise 54 54 54 54 55
Watts 413 419 467 527 750
CFM 1803 1807 1785 1774 1755
Temp. Rise 49 48 49 49 50
Watts 529 532 582 646 864
100% (high)
Heat
Low
1460
Medium Low
1540
Medium**
1620
High
1790
High
1289
672
High
743
639
Medium**
Low
1051
Medium Low
1109
606
Medium**
1166
40% (low) Heat
Low
Heating
*UHMC100ACV4VB^ Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
Airflow
Setting
Target Airflow
(See Note 5)
External Static Pressure
Medium Low
65%
(medium)
Heat
0.1 0.3 0.5 0.7 0.9
CFM 728 758 785 805 819
Temp. Rise 62 59 57 56 55
Watts 119 107 102 94 108
CFM 769 797 822 840 853
Temp. Rise 58 56 54 53 53
Watts 113 107 111 113 133
CFM 813 841 864 880 890
Temp. Rise 55 53 52 51 50
Watts 108 107 122 135 160
CFM 863 889 910 923 930
Temp. Rise 52 50 49 49 48
Watts 104 108 135 160 191
CFM 1213 1232 1237 1232 1220
Temp. Rise 60 60 59 60 60
Watts 131 160 253 345 405
CFM 1279 1297 1299 1290 1274
Temp. Rise 57 57 56 57 58
Watts 147 178 281 382 445
CFM 1353 1369 1367 1355 1335
Temp. Rise 54 54 54 54 55
Watts 168 201 313 423 489
CFM 1434 1448 1443 1426 1402
Temp. Rise 51 51 51 51 52
Watts 197 229 352 469 538
CFM 1699 1707 1690 1659 1621
Temp. Rise 60 60 60 61 63
Watts 325 349 495 628 698
CFM 1790 1797 1775 1740 1696
Temp. Rise 57 57 57 59 60
Watts 382 400 551 685 752
CFM 1892 1896 1870 1830 1781
Temp. Rise 54 54 54 56 57
Watts 453 462 616 750 813
CFM 2004 2006 1975 1929 1873
Temp. Rise 51 51 52 53 54
Watts 540 538 694 822 880
100% (high)
Heat
Low
1700
Medium Low
1790
Medium**
1890
High
2000
High
1440
832
High
880
788
Medium**
Low
1224
Medium Low
1289
748
Medium**
1361
45% (low) Heat
Low
Heating
*UHMD120ACV5VB^ Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
Airflow
Setting
Target Airflow
(See Note 5)
External Static Pressure
Medium Low
65%
(medium)
Heat
Notes:
1. * First letter may be "A" or "T".
3. ** Factory setting.
2. ^ Letter may be “A” through “Z”.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
6. Target airflow is field selectable for high (100%) heat. Target airflow for low and medium heat are percentages of high heat and are not field selectable.
Pub. No. 22-1840-14
9
Page 10
TUHM AIRFLOW - COOLING
0.1 0.3 0.5 0.7 0.9
CFM
356 476 488 511 519
Watts
29 67 97 132 167
CFM
389 504 516 538 545
Watts
32 71 102 138 174
CFM
422 533 544 565 572
Watts
36 75 107 144 181
CFM
455 561 566 589 592
Watts
39 79 111 150 187
CFM
487 589 600 619 624
Watts
43 84 119 158 197
CFM
537 631 655 669 673
Watts
50 92 130 171 212
CFM
586 674 684 700 702
Watts
57 101 139 182 223
CFM
619 695 717 727 733
Watts
63 106 150 193 236
CFM
515 613 623 641 646
Watts
47 88 124 164 204
CFM
559 650 660 677 681
Watts
53 96 133 175 215
CFM
602 688 698 713 716
Watts
60 104 143 186 228
CFM
646 707 737 748 752
Watts
68 112 156 200 243
CFM
690 763 772 785 785
Watts
76 123 165 211 255
CFM
764 816 778 847 844
Watts
86 137 180 231 275
CFM
821 876 884 892 890
Watts
108 159 206 256 303
CFM
937 968 977 985 984
Watts
136 193 241 295 343
CFM
673 749 758 771 772
Watts
73 119 161 206 250
CFM
732 791 756 766 818
Watts
79 129 160 203 268
CFM
783 843 852 861 860
Watts
98 147 193 242 288
CFM
848 894 908 917 917
Watts
110 163 212 262 308
CFM
892 937 945 951 947
Watts
129 182 232 284 333
CFM
972 1015 972 957 1036
Watts
160 213 262 312 374
CFM
1057 1078 1085 1085 1078
Watts
191 249 306 360 415
CFM
1115 1137 1142 1140 1139
Watts
214 275 333 388 447
CFM
832 885 894 901 899
Watts
111 162 210 260 308
CFM
898 942 950 955 951
Watts
131 184 234 286 336
CFM
964 998 1006 1009 1004
Watts
154 209 262 314 366
CFM
1039 1065 1073 1074 1075
Watts
181 237 292 344 402
CFM
1095 1111 1118 1116 1108
Watts
208 268 326 380 436
CFM
1189 1212 1214 1149 1207
Watts
257 320 380 435 500
CFM
1292 1280 1285 1278 1201
Watts
317 383 448 501 508
CFM
1326 1317 1361 1242 1166
Watts
366 433 495 510 509
Notes:
1. * First letter may be "A" or "T".
2. ^ Letter may be "A" through "Z"
3. ** Factory setting.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
Cooling
Unit
Outdoor
Airflow
Setting
External Static Pressure
1.5
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
2
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
430 CFM/ton
450 CFM/ton
*UHMB060ACV3VB^ Furnace Cooling Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
450 CFM/ton
3
290 CFM/ton
310 CFM/ton
2.5
290 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
10
NOTE: CONTINUOUS fan mode during COOLING operation may not be appropriate in humid climates. If the indoor air exceeds 60% relative humidity or simply feels uncomfortably humid, it is recommended that the fan only be used in the AUTO mode.
Pub. No. 22-1840-14
Page 11
TUHM AIRFLOW - COOLING
0.1 0.3 0.5 0.7 0.9
CFM
504 565 586 521 540
Watts
34 70 104 138 172
CFM
547 604 624 559 579
Watts
40 77 112 147 182
CFM
590 644 663 597 617
Watts
47 85 121 157 193
CFM
656 695 701 703 694
Watts
54 93 130 167 204
CFM
676 724 740 674 694
Watts
62 102 140 179 217
CFM
764 792 801 795 789
Watts
75 116 157 197 238
CFM
806 844 856 788 810
Watts
89 133 175 216 259
CFM
877 899 901 895 886
Watts
102 145 188 230 275
CFM
660 709 726 659 680
Watts
59 99 136 174 212
CFM
740 768 772 769 764
Watts
70 109 149 189 229
CFM
768 809 822 755 776
Watts
81 123 164 205 246
CFM
848 869 871 868 858
Watts
94 138 179 220 265
CFM
875 909 918 850 872
Watts
107 153 197 240 284
CFM
978 994 992 989 980
Watts
130 179 224 270 316
CFM
1037 1058 1063 994 1017
Watts
157 209 258 305 354
CFM
1093 1096 1082 1065 1051
Watts
174 227 276 324 378
CFM
816 854 865 798 819
Watts
92 136 178 220 262
CFM
881 914 923 855 877
Watts
108 155 199 242 286
CFM
945 974 981 912 935
Watts
127 176 222 266 313
CFM
1029 1043 1043 1035 1028
Watts
148 199 246 292 340
CFM
1074 1093 1097 1027 1050
Watts
170 224 274 322 372
CFM
1170 1181 1184 1180 1174
Watts
206 262 317 370 423
CFM
1268 1276 1270 1199 1224
Watts
254 314 372 430 484
CFM
1321 1321 1306 1295 1251
Watts
287 351 415 477 518
CFM
972 998 1005 936 959
Watts
135 185 232 277 324
CFM
1047 1068 1073 1003 1026
Watts
161 213 262 310 359
CFM
1123 1138 1140 1070 1094
Watts
189 244 296 347 398
CFM
1195 1204 1208 1205 1195
Watts
215 275 329 383 437
CFM
1273 1278 1275 1204 1228
Watts
257 317 376 433 488
CFM
1375 1385 1384 1383 1305
Watts
316 383 444 513 513
CFM
1499 1487 1491 1392 1303
Watts
389 457 513 513 513
CFM
1513 1512 1508 1418 1341
Watts
398 470 529 524 522
Notes:
1. * First letter may be "A" or "T".
2. ^ Letter may be "A" through "Z"
3. ** Factory setting.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
350 CFM/ton
3.5
290 CFM/ton
310 CFM/ton
330 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
3
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
2.5
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
290 CFM/ton
310 CFM/ton
330 CFM/ton
2
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
Unit
Outdoor
Airflow Setting
External Static Pressure
*UHMB080ACV3VB^ Furnace Cooling Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
Cooling
Pub. No. 22-1840-14
NOTE: CONTINUOUS fan mode during COOLING operation may not be appropriate in humid climates. If the indoor air exceeds 60% relative humidity or simply feels uncomfortably humid, it is recommended that the fan only be used in the AUTO mode.
11
Page 12
TUHM AIRFLOW - COOLING
Watts
171 220 271 322 368
Watts
258 314 373 432 488
CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
*UHMC100ACV4VB^ Furnace Cooling Airflow (CFM) and Power (Watts) vs. External Static
External Static Pressure
Pressure With Filter
Unit
Outdoor
2.5
Cooling
3.5
Notes:
1. * First letter may be "A" or "T".
2. ^ Letter may be "A" through "Z"
3. ** Factory setting.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID
3
4
Airflow Setting
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
0.1 0.3 0.5 0.7 0.9
714 734 739 733 722
79 118 157 194 231
765 784 789 782 770
88 128 168 206 244
816 834 838 831 819
96 138 179 220 258 868 884 887 880 867 103 149 192 234 273 919 934 936 929 916 117 161 205 249 290 995 1009 1009 1002 989 135 181 227 274 316
1072 1084 1083 1075 1061
156 204 253 302 346
1123 1134 1132 1124 1110
862 879 882 875 863 105 148 190 232 272 924 939 941 934 921 118 162 207 250 291 985 999 1000 992 979 133 178 224 270 313
1046 1059 1059 1051 1037
149 196 244 292 336
1108 1119 1117 1109 1095
167 215 265 316 362
1200 1209 1206 1197 1183
197 248 301 355 404
1292 1299 1294 1285 1270
232 286 343 400 453
1353 1359 1353 1344 1328
1011 1024 1024 1017 1003
139 185 232 279 322
1082 1094 1093 1085 1071
159 207 256 306 351
1154 1164 1162 1153 1139
181 231 283 335 382
1225 1234 1230 1222 1207
206 258 312 367 417
1297 1304 1299 1290 1275
234 288 345 402 455
1404 1409 1402 1393 1377
281 340 400 462 520
1512 1514 1505 1495 1478
336 399 464 530 595
1583 1584 1574 1564 1546
377 444 512 580 650
1159 1169 1167 1158 1144
183 233 285 337 385
1241 1249 1245 1236 1221
212 264 319 374 425
1323 1329 1324 1315 1299
244 300 358 416 470
1404 1409 1402 1393 1377
281 340 400 462 520
1486 1489 1481 1471 1454
322 384 448 513 576
1609 1609 1599 1588 1571
393 461 530 599 671
1732 1730 1716 1705 1687
475 550 624 698 781
1813 1810 1795 1783 1765
536 617 694 772 864
NOTE: CONTINUOUS fan mode during COOLING operation may not be appropriate in humid climates. If the indoor air exceeds 60% relative humidity or simply feels uncomfortably humid, it is recommended that the fan only be used in the AUTO mode.
12
Pub. No. 22-1840-14
Page 13
TUHM AIRFLOW - COOLING
0.1 0.3 0.5 0.7 0.9
CFM
1000 1024 1028 1022 1011
Watts
122 168 209 251 300
CFM
1072 1094 1097 1089 1076
Watts
140 188 234 281 331
CFM
1143 1164 1165 1157 1141
Watts
160 211 261 313 364
CFM
1214 1233 1234 1224 1207
Watts
182 236 291 347 400
CFM
1286 1303 1302 1291 1272
Watts
207 264 323 384 438
CFM
1393 1408 1405 1392 1370
Watts
250 311 377 444 500
CFM
1500 1513 1508 1492 1468
Watts
300 365 437 509 565
CFM
1571 1582 1576 1559 1533
337 406 481 555 611
CFM
1148 1169 1170 1161 1146
Watts
161 213 263 315 367
CFM
1230 1248 1248 1238 1221
Watts
187 242 297 355 408
CFM
1311 1328 1327 1315 1295
Watts
217 274 335 398 452
CFM
1393 1408 1405 1392 1370
Watts
250 311 377 444 500
CFM
1474 1488 1483 1468 1445
Watts
287 352 422 493 549
CFM
1597 1607 1601 1583 1556
Watts
352 421 497 572 628
CFM
1719 1727 1718 1699 1668
Watts
427 503 581 655 711
CFM
1801 1807 1797 1775 1743
483 563 642 712 768
CFM
1444 1458 1454 1440 1417
Watts
273 336 405 475 530
CFM
1546 1557 1552 1535 1510
Watts
324 391 465 538 594
CFM
1648 1657 1650 1631 1603
Watts
381 454 531 606 662
CFM
1750 1757 1748 1727 1696
Watts
447 525 603 676 732
CFM
1852 1857 1845 1823 1790
Watts
522 604 682 749 804
CFM
2004 2006 1992 1967 1947
Watts
651 742 811 863 966
CFM
2157 2156 2140 2050 1947
Watts
803 902 966 966 966
CFM
2259 2255 2140 2050 1947
Notes:
1. * First letter may be "A" or "T".
2. ^ Letter may be "A" through "Z"
3. ** Factory setting.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected
cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID
CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
*UHMD120ACV5VB^
Pressure With Filter
Furnace Cooling Airflow (CFM) and Power (Watts) vs. External Static
Outdoor
Cooling
Unit
3.5
4
Airflow Setting
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
External Static Pressure
Watts
5
450 CFM/ton
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
Watts
Watts
966 966 966 966 966
NOTE: CONTINUOUS fan mode during COOLING operation may not be appropriate in humid climates. If the indoor air exceeds 60% relative humidity or simply feels uncomfortably humid, it is recommended that the fan only be used in the AUTO mode.
Pub. No. 22-1840-14
13
Page 14
TDHM AIRFLOW - HEATING
0.1 0.3 0.5 0.7 0.9
Watts 129 119 207 206 291
Watts 286 240 382 348 460
(See Note 5)
External Static Pressure
Setting
Notes:
1. * First letter may be "A" or "T".
3. ** Factory setting.
2. ^ Letter may be “A” through “Z”.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
6. Target airflow is field selectable for high (100%) heat. Target airflow for low and medium heat are percentages of high heat and are not field selectable.
CFM 438 436 458 462 474
CFM 460 458 479 483 493
Temp. Rise 46 46 44 44 43
Watts 28 52 73 92 118
CFM 499 497 516 518 526
Temp. Rise 42 42 41 41 40
Temp. Rise 38 38 37 37 37
Watts 42 68 90 114 144
Temp. Rise 48 48 48 48 48
Watts 76 106 140 176 217
CFM 753 751 755 749 740
Temp. Rise 46 46 45 46 46
Watts 87 117 154 194 237
Watts 108 140 183 228 275
CFM 911 909 904 892 873
Temp. Rise 38 38 38 38 39
Watts 142 177 226 276 326
CFM 906 904 900 888 869
Temp. Rise 58 58 59 59 61
Watts 140 175 223 274 323
CFM 954 952 945 931 910
Temp. Rise 55 55 56 57 58
Temp. Rise 51 51 51 52 54
Watts 202 243 295 347 393
CFM 1157 1155 1136 1115 1080
Temp. Rise 46 46 46 47 49
Watts 269 317 361 405 439
*DHMB060BCV3VB^
40% (low) Heat
65% (medium)
Heating
100% (high)
Heat
Heat
Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
Airflow Setting
Low
Medium Low
Medium**
High
Low
Medium Low
Medium**
High
Low
Medium Low
Medium**
High
Target Airflow
(See Note 5)
414
437
478
534
702
741
811
905
900
950
1040
1160
0.1 0.3 0.5 0.7 0.9
Temp. Rise 48 48 46 46 45
Watts 26 49 70 90 115
Watts 33 58 79 100 127
CFM 553 551 567 567 571
CFM 715 713 720 714 708
CFM 820 818 819 810 797
Temp. Rise 42 42 42 42 43
Watts 160 197 248 300 350
CFM 1041 1039 1027 1010 983
External Static Pressure
*DHMB080ACV3VB^ Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
Target Airflow
1400
CFM 648 670 681 685 687
Temp. Rise 57 55 54 54 54
Watts 79 79 148 155 219
CFM 676 698 708 711 712
Temp. Rise 54 53 52 52 52
Watts 85 85 156 163 230
CFM 705 725 735 737 736
Temp. Rise 52 51 50 50 50
Watts 93 90 165 170 241
CFM 824 841 849 846 838
Temp. Rise 45 44 43 43 44
CFM 923 937 943 936 923
Temp. Rise 55 54 54 54 55
Watts 166 148 249 241 336
CFM 962 974 980 972 956
Temp. Rise 52 52 51 52 53
Watts 183 161 268 256 355
CFM 1001 1012 1017 1008 990
Temp. Rise 50 50 50 50 51
Watts 201 174 288 272 374
CFM 1165 1171 1173 1158 1130
Temp. Rise 43 43 43 44 45
CFM 1318 1319 1319 1297 1261
Temp. Rise 53 53 53 54 56
Watts 382 314 485 431 549
CFM 1372 1372 1370 1347 1307
Temp. Rise 51 51 51 52 54
Watts 420 343 526 463 582
CFM 1426 1424 1422 1396 1354
Temp. Rise 49 49 49 50 52
Watts 460 373 569 497 617
CFM 1654 1645 1639 1605 1549
Temp. Rise 42 43 43 44 45
Watts 650 518 770 655 772
40% (low) Heat
65%
(medium)
Heating
Heat
100% (high)
Heat
Airflow
Low 683
Medium Low 709
Medium** 735
High 845
Low 936
Medium Low 972
Medium** 1008
High 1159
Low 1300
Medium Low 1350
Medium**
High 1610
14
Pub. No. 22-1840-14
Page 15
TDHM AIRFLOW - HEATING
0.1 0.3 0.5 0.7 0.9
Watts 40 118 140 235 247
Watts 180 304 288 441 466
Watts 413 583 483 726 726
*DHMC100ACV4VB^ Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
Setting
(See Note 5)
Notes:
1. * First letter may be "A" or "T".
3. ** Factory setting.
2. ^ Letter may be “A” through “Z”.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
6. Target airflow is field selectable for high (100%) heat. Target airflow for low and medium heat are percentages of high heat and are not field selectable.
*DHMD120BCV5VB^ Furnace Heating Airflow (CFM) and Power (Watts) v s. External Static Pressure With Filter
40% (low) Heat
65%
(medium)
Heating
Heat
100% (high)
Heat
Airflow
Target Airflow
Low 668
Medium Low 712
Medium** 734
High 757
Low 1080
Medium Low
Medium**
1152
1188
High 1224
Low
1500
Medium Low 1600
Medium** 1650
High 1700
External Static Pressure
CFM 666 657 643 628 609
Temp. Rise 59 59 61 62 64
Watts 24 92 116 206 206
CFM 710 701 686 670 650
Temp. Rise 55 56 57 58 60
Watts 32 105 128 220 227
CFM 732 723 708 690 670
Temp. Rise 53 54 55 56 58
Watts 36 111 134 227 237
CFM 755 744 729 711 690
Temp. Rise 52 52 53 55 56
CFM 1077 1063 1041 1016 985
Temp. Rise 59 59 61 62 64
Watts 128 237 237 368 398
CFM 1149 1134 1110 1083 1051
Temp. Rise 55 56 57 58 60
Watts 153 270 262 404 432
CFM 1185 1169 1145 1117 1084
Temp. Rise 53 54 55 56 58
Watts 166 286 275 422 449
CFM 1221 1205 1180 1151 1117
Temp. Rise 52 52 53 55 56
CFM 1496 1476 1446 1410 1368
Temp. Rise 59 59 61 62 64
Watts 304 455 396 604 596
CFM 1596 1575 1542 1504 1460
Temp. Rise 55 56 57 58 60
Watts 356 517 438 670 643
CFM 1646 1624 1590 1551 1505
Temp. Rise 53 54 55 56 58
Watts 384 550 461 705 667
CFM 1696 1673 1639 1598 1551
Temp. Rise 52 52 53 55 56
40% (low) Heat
65% (medium)
Heating
Heat
100% (high) Heat
Airflow Setting
Low
Medium Low
Medium**
High
Low
Medium Low
Medium** 1469
High
Low
Medium Low
Medium**
High
Target Airflow
(See Note 5)
780
827
870
959
1195
1267
1685
1660
1760
1850
2040
CFM 827 870 800 779 785
Temp. Rise 57 55 59 61 60
Watts 76 98 142 175 212
CFM 871 917 846 827 834
Temp. Rise 55 52 56 57 57
Watts 85 108 153 188 226
CFM 911 959 889 872 878
Temp. Rise 52 50 53 54 54
Watts 94 117 165 201 240
CFM 994 1047 977 964 969
Temp. Rise 48 45 49 49 49
Watts 116 140 191 230 272
CFM 1214 1282 1211 1209 1212
Temp. Rise 57 54 57 57 57
Watts 193 223 285 334 385
CFM 1281 1353 1282 1283 1286
Temp. Rise 54 51 54 53 53
Watts 224 255 322 375 431
CFM 1470 1553 1482 1493 1493
Temp. Rise 47 44 46 46 46
Watts 329 366 449 517 592
CFM 1671 1767 1696 1717 1715
Temp. Rise 41 39 40 40 40
Watts 479 519 633 722 831
CFM 1648 1743 1671 1691 1690
Temp. Rise 64 61 63 62 62
Watts 459 499 609 695 799
CFM 1741 1842 1770 1795 1792
Temp. Rise 61 57 60 59 59
Watts 541 582 709 808 932
CFM 1825 1931 1859 1888 1885
Temp. Rise 58 55 57 56 56
Watts 624 663 811 922 1068
CFM 2002 1983 1977 1902 1853
Temp. Rise 53 53 53 55 57
Watts 827 925 925 925 925
0.1 0.3 0.5 0.7 0.9
External Static Pressure
Pub. No. 22-1840-14
15
Page 16
TDHM AIRFLOW - COOLING
Watts 70 99 130 164 203
Watts 140 175 223 274 323
*DHMB060BCV3VB^ Furnace Cooling Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
External Static Pressure
Unit Outdoor
Size (tons)
1.5
2
Cooling
2.5
3
Notes:
1. * First letter may be "A" or "T".
2. ^ Letter may be "A" through "Z"
3. ** Factory setting.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID CLIMATE setting;
NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
Airflow Setting
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
CFM 458 456 477 481 491
Watts 28 52 73 92 118
CFM 487 485 504 507 515
Watts 32 56 77 97 124
CFM 516 514 532 533 540
Watts 36 61 82 104 132
CFM 545 543 559 560 564
Watts 40 66 88 111 141
CFM 574 572 586 586 589
Watts 45 72 95 120 151
CFM 617 615 627 625 625
Watts 54 81 107 135 169
CFM 660 658 668 665 662
Watts 63 91 120 152 189
CFM 689 687 695 691 686
CFM 598 596 609 608 609
Watts 50 77 101 128 161
CFM 636 634 645 643 641
Watts 58 85 113 142 177
CFM 675 673 682 678 674
Watts 66 95 125 158 196
CFM 713 711 718 713 706
Watts 76 105 139 175 216
CFM 752 750 754 748 739
Watts 87 117 154 193 236
CFM 810 808 809 800 788
Watts 104 136 178 222 269
CFM 868 866 863 853 836
Watts 125 159 205 253 301
CFM 906 904 900 888 869
CFM 738 735 741 735 727
Watts 82 113 148 186 228
CFM 786 784 786 778 767
Watts 97 128 168 210 255
CFM 834 832 831 822 808
Watts 112 145 189 235 282
CFM 882 880 877 866 849
Watts 130 164 212 261 310
CFM 930 928 922 909 889
Watts 150 186 236 287 337
CFM 1003 1000 990 975 950
Watts 183 222 274 326 375
CFM 1075 1073 1059 1041 1011
Watts 220 263 314 364 408
CFM 1123 1121 1104 1084 1052
Watts 248 294 341 389 427
CFM 877 875 872 861 845
Watts 128 162 209 258 307
CFM 935 933 927 914 893
Watts 152 188 238 289 339
CFM 993 991 981 966 942
Watts 178 217 268 321 370
CFM 1051 1049 1036 1019 991
Watts 207 249 300 352 398
CFM 1109 1106 1090 1071 1040
Watts 239 284 333 381 422
CFM 1195 1193 1172 1150 1113
Watts 294 345 384 422 449
CFM 1282 1280 1254 1229 1186
Watts 357 414 436 456 463
CFM 1334 1351 1272 1201 1125
Watts 405 466 463 459 455
0.1 0.3 0.5 0.7 0.9
NOTE: CONTINUOUS fan mode during COOLING operation may not be appropriate in humid climates. If the indoor air exceeds 60% relative humidity or simply feels uncomfortably humid, it is recommended that the fan only be used in the AUTO mode.
16
Pub. No. 22-1840-14
Page 17
TDHM AIRFLOW - COOLING
125 168 208 248 287
Watts
221 272 319 366 411
Watts
360 415 473 502 502
CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
*DHMB080ACV3VB^ Furnace Cooling Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
Unit
Outdoor
2
2.5
Cooling
3
Notes:
1. * First letter may be "A" or "T".
2. ^ Letter may be "A" through "Z"
3. ** Factory setting.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID
Airflow Setting
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
External Static Pressure
0.1 0.3 0.5 0.7 0.9
535 558 572 580 580
44 74 108 142 175
579 601 614 620 619
51 82 118 152 187
622 643 655 660 659
58 92 128 163 199
665 697 705 697 694
67 104 141 175 214
709 728 738 741 737
76 113 151 187 225
779 802 809 797 793
90 131 169 207 250 839 854 863 862 855 110 152 192 231 272 903 917 916 906 891
692 712 723 726 722
72 109 146 182 220 747 765 774 776 771
85 123 162 199 238 801 817 826 827 820
99 140 179 217 257 855 870 878 877 869 115 157 198 237 278 909 923 930 927 918 132 177 218 259 301
1005 1014 1014 1003 993
164 211 252 295 337
1072 1082 1086 1078 1065
196 246 291 336 381
1126 1134 1137 1129 1114
849 865 873 872 864 113 156 196 235 276 915 928 935 932 923 134 179 221 261 303 980 992 997 993 982 158 205 248 290 333
1045 1055 1060 1053 1041
184 233 278 322 366
1110 1119 1122 1114 1100
213 264 311 357 402
1211 1208 1209 1202 1195
260 312 366 418 465
1305 1309 1309 1295 1242
319 373 428 482 502
1370 1372 1371 1320 1242
NOTE: CONTINUOUS fan mode during COOLING operation may not be appropriate in humid climates. If the indoor air exceeds 60% relative humidity or simply feels uncomfortably humid, it is recommended that the fan only be used in the AUTO mode.
Pub. No. 22-1840-14
17
Page 18
TDHM AIRFLOW - COOLING
0.1 0.3 0.5 0.7 0.9
CFM
723 713 699 682 661
Watts
58 109 157 204 234
CFM
773 763 747 729 707
Watts
72 125 174 222 256
CFM
823 812 795 776 753
Watts
87 141 182 241 279
CFM
873 861 842 823 798
Watts
103 158 210 260 302
CFM
923 910 892 870 844
Watts
120 177 229 279 325
CFM
998 984 964 940 912
Watts
148 206 258 309 360
CFM
1072 1058 1036 1011 981
Watts
179 238 290 341 396
CFM
1122 1107 1084 1058 1026
Watts
201 260 312 362 420
CFM
868 856 839 818 794
Watts
101 157 208 258 299
CFM
928 915 896 874 849
Watts
122 179 231 281 327
CFM
988 974 954 931 903
Watts
144 202 254 305 356
CFM
1047 1033 1012 987 958
Watts
169 227 279 330 384
CFM
1107 1092 1070 1044 1013
Watts
195 253 305 356 413
CFM
1197 1181 1157 1128 1095
Watts
237 296 346 395 455
CFM
1287 1269 1243 1213 1177
Watts
284 341 390 436 498
CFM
1347 1329 1301 1269 1232
Watts
317 373 420 465 526
CFM
1013 999 978 954 926
Watts
154 212 265 315 367
CFM
1082 1068 1048 1020 990
Watts
184 242 294 345 401
CFM
1152 1137 1113 1086 1054
Watts
215 274 325 375 434
CFM
1222 1206 1181 1152 1118
Watts
250 308 358 406 467
CFM
1292 1274 1248 1218 1182
Watts
286 344 392 439 500
CFM
1397 1378 1349 1316 1277
Watts
346 401 446 489 548
CFM
1501 1481 1451 1415 1373
Watts
411 463 503 541 595
CFM
1571 1550 1518 1481 1437
Watts
457 507 543 577 625
CFM
1157 1142 1118 1091 1058
Watts
218 276 328 377 436
CFM
1237 1220 1195 1166 1131
Watts
257 315 365 413 474
CFM
1317 1299 1272 1241 1204
Watts
300 357 405 450 512
CFM
1397 1378 1349 1316 1277
Watts
346 401 446 489 548
CFM
1476 1456 1426 1392 1350
Watts
395 448 489 529 584
CFM
1596 1575 1542 1504 1460
Watts
474 523 558 591 636
CFM
1716 1693 1658 1617 1569
Watts
560 604 631 726 726
CFM
1796 1771 1735 1693 1642
Watts
622 661 682 726 726
Notes:
1. * First letter may be "A" or "T".
2. ^ Letter may be "A" through "Z"
3. ** Factory setting.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
External Static Pressure
290 CFM/ton
*DHMC100ACV4VB^ Furnace Cooling Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
310 CFM/ton
330 CFM/ton
Unit
Outdoor
Airflow Setting
450 CFM/ton
3
290 CFM/ton
310 CFM/ton
330 CFM/ton
2.5
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
430 CFM/ton
450 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
3.5
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
Cooling
4
290 CFM/ton
310 CFM/ton
430 CFM/ton
450 CFM/ton
370 CFM/ton
400 CFM/ton
330 CFM/ton
350 CFM/ton
18
NOTE: CONTINUOUS fan mode during COOLING operation may not be appropriate in humid climates. If the indoor air exceeds 60% relative humidity or simply feels uncomfortably humid, it is recommended that the fan only be used in the AUTO mode.
Pub. No. 22-1840-14
Page 19
TDHM AIRFLOW - COOLING
*DHMD120BCV5VB^ Furnace Cooling Airflow (CFM) & Power (Watts) vs. External Static Pressure w/Filter
0.1 0.3 0.5 0.7 0.9
CFM 1046 1103 1032 1027 1022
Watts 131 157 210 251 295
CFM 1111 1172 1102 1099 1095
Watts 153 180 237 280 326
CFM 1177 1242 1171 1171 1167
Watts 178 207 266 313 363
CFM 1242 1311 1240 1243 1240
Watts 205 236 300 350 404
CFM 1307 1381 1310 1315 1312
Watts 236 269 337 392 450
CFM 1405 1485 1414 1422 1421
Watts 289 325 401 464 531
CFM 1503 1589 1518 1530 1530
Watts 351 389 476 547 627
CFM 1569 1658 1587 1602 1603
Watts 397 436 533 610 700
CFM 1181 1247 1176 1176 1172
Watts 180 209 269 316 365
CFM 1256 1326 1255 1258 1255
Watts 212 243 308 359 413
CFM 1331 1405 1335 1340 1338
Watts 248 282 352 408 468
CFM 1405 1485 1414 1422 1421
Watts 289 325 401 464 531
CFM 1480 1564 1493 1505 1504
Watts 336 373 457 526 602
CFM 1592 1683 1612 1628 1629
Watts 415 454 554 634 728
CFM 1704 1802 1731 1751 1753
Watts 507 548 667 761 877
CFM 1778 1882 1810 1833 1836
Watts 577 617 753 857 991
CFM 1452 1534 1463 1474 1473
Watts 318 354 436 502 574
CFM 1545 1634 1562 1577 1577
Watts 380 419 512 587 673
CFM 1639 1733 1661 1679 1681
Watts 452 492 599 685 787
CFM 1732 1832 1760 1782 1784
Watts 533 573 699 796 918
CFM 1825 1931 1859 1885 1888
Watts 624 663 811 922 925
CFM 1965 2080 1977 1902 1853
Watts 781 925 925 925 925
CFM 2064 2229 1977 1902 1853
Watts 925 925 925 925 925
CFM 2064 2250 1977 1902 1853
Watts 925 925 925 925 925
Notes:
1. * First letter may be "A" or "T".
2. ^ Letter may be "A" through "Z"
3. ** Factory setting.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID CLIMATE setting;
NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
Cooling
290 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
External Static Pressure
Airflow Setting
Unit Outdoor Size
(tons)
310 CFM/ton
330 CFM/ton
290 CFM/ton
290 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
3.5
4
5
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
Pub. No. 22-1840-14
NOTE: CONTINUOUS fan mode during COOLING operation may not be appropriate in humid climates. If the indoor air exceeds 60% relative humidity or simply feels uncomfortably humid, it is recommended that the fan only be used in the AUTO mode.
19
Page 20
Maximum Vent
ALTITUDE
NATURAL GASPROPANE NATURAL GASPROPANE NATURAL GASPROPANE
UH/DHMB060ACV3V 200 Not Allowed 200 Not Allowed 200 150 UH/DHMB080ACV3V 50 Not Allowed 120 Not Allowed200 150 UH/DHMC100ACV4V Not Allowed Not Allowed 60 Not Allowed 200 150
DHMD120ACV5V Not Allowed Not Allowed Not Allowed Not Allowed 200 100
NATURAL GASPROPANE NATURAL GASPROPANE NATURAL GASPROPANE
UH/DHMB060ACV3V 100 Not Allowed 100 Not Allowed 100 100 UH/DHMB080ACV3V 25 Not Allowed 60 Not Allowed 100 100 UH/DHMC100ACV4V Not Allowed Not Allowed 30 Not Allowed 100100
DHMD120ACV5V Not Allowed Not Allowed Not Allowed Not Allowed 10050
NATURAL GASPROPANE NATURAL GASPROPANE NATURAL GASPROPANE
UH/DHMB060ACV3V 50 Not Allowed 50 Not Allowed 50 38 UH/DHMB080ACV3V Not Allowed Not Allowed 30 Not Allowed 50 38 UH/DHMC100ACV4V Not Allowed Not Allowed Not Allowed Not Allowed 50 38
DHMD120ACV5V Not Allowed Not Allowed Not Allowed Not Allowed 50 25
Notes: * - First letter may be "A" or "T", ** - Last two digits may be "A" thru "Z"
1. Minimum vent length for all models: 3' horizontal or 3' vertical
2. DO NOT MIX PIPE DIAMETERS IN THE SAME LENGTH OF PIPE OUTSIDE THE FURNACE CABINET, (Except adapters at the top of the furnace). If different inlet and vent pipe sizes are used, the vent pipe must adhere to the maximum length limit shown in the table above (See note 6 below for exception). The inlet pipe can be of a larger diameter, but never smaller than the vent pipe.
3. MAXIMUM PIPE LENGTHS MUST NOT BE EXCEEDED! THE LENGTH SHOWN IS NOT A COMBINED TOTAL, IT IS THE MAXIMUM LENGTH OF EACH (Vent or Inlet air pipes).
4. One SHORT radius 90° elbow is equivalent to 10' of 3" pipe and one LONG radius elbow is equivalent to 6' of 3" pipe. One 90° elbow is equivalent to 7½' of 2½" pipe or 5' of 2" pipe. Two 45° elbows equal one 90° elbow.
5. The termination tee or bend must be included in the total number of elbows. If the BAYAIR30AVENTA termination kit is used, the equivalent length of pipe is 5 feet. BAYVENT200B equivalent length is 0 feet.
6. Pipe adapters are field supplied. Downflow models, UHM 100 and UHM 120 models include the 2" x 3" adapter.
3 or 4 INCH PIPE
3 or 4 INCH PIPE2.5 INCH PIPE2 INCH PIPE
VENT LENGTH TABLE - MODULATING FURNACE
0-7000 Feet
7000-9500 Feet
9500-12000 Feet
3 or 4 INCH PIPE2.5 INCH PIPE2 INCH PIPE
2 INCH PIPE 2.5 INCH PIPE
MAXIMUM TOTAL EQUIVALENT LENGTH IN FEET FOR VENT AND INLET
AIR (SEE NOTES)
7. For Canadian applications ONLY, IPEX 196006 may be used for horizontal and vertical terminations. IPEX 081216, IPEX 081218, and IPEX 081219 may only be used for horizontal vent terminations. Equivalent lengths are IPEX 196009 = 5 feet, IPEX 081216 = 11 feet, IPEX 081218 = 16 feet, and IPEX 081219 = 21 feet
UHMD120ACV5V Not Allowed Not Allowed Not Allowed Not Allowed 200 150
UHMD120ACV5V Not Allowed Not Allowed Not Allowed Not Allowed 100 100
UHMD120ACV5V Not Allowed Not Allowed Not Allowed Not Allowed 50 38
Length Table
20
Pub. No. 22-1840-14
Page 21
Electrical Data
CAUTION
!
TUHM Wiring Diagram
Pub. No. 22-1840-14
Label all wires prior to disconnection when servicing con­trols. Wiring errors can cause improper and dangerous opera­tion. Verify proper operation after servicing.
21
Page 22
Electrical
CAUTION
!
Data
TUHM Schematic Diagram
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
22
Pub. No. 22-1840-14
Page 23
Electrical
CAUTION
!
Data
TDHM Wiring Diagram
Pub. No. 22-1840-14
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
23
Page 24
Electrical
CAUTION
!
Data
TDHM Schematic Diagram
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
24
Pub. No. 22-1840-14
Page 25
NOTE: The maximum total cable length for the entire Comfort Control communicating system is 500 ft. 18 AWG. The maximum distance of any single cable from a trans­former is 250 ft. 18 AWG.
NOTE: When connecting an TFD whole house air cleaner with this furnace, order BAYACCECOMM101.
NOTE: The BAYACCECOMM101 must be used when connecting an TFD whole house air cleaner to a furnace in communicating mode. For 24 volt mode, see the installation in the whole house air cleaner Installer's Guide.
NOTE: The BAYACCECOMM101 can be ordered through the sales channels.
NOTE: The B/C terminal will require three wires to be connected. Rather than connecting the three wires to the low voltage terminal strip, create a pigtail using a short length of thermostat wire and a wire nut (field supplied) to attach to the B/C terminal.
Communicating Indoor Unit with Communicating Comfort Control and Communicating Outdoor Unit
Pub. No. 22-1840-14
25
Page 26
Communicating Indoor Unit with Communicating Comfort Control and 24VAC Single Stage Cooling
24 VAC Mode Indoor Unit with 24 VAC Comfort Control and 24VAC Single Stage Cooling
26
Pub. No. 22-1840-14
Page 27
24 VAC Mode Indoor Unit with 24 VAC Comfort Control and 24VAC 2-Stage or 2-Step Cooling
24 VAC Mode Indoor Unit with 24 VAC Comfort Control and 24VAC Single Stage Heat Pump
Pub. No. 22-1840-14
27
Page 28
24 VAC Mode Indoor Unit with 24 VAC Comfort Control and 24VAC 2-Stage or 2-Step Heat Pump
BK Jumper
Humidistat Hookup - 24 V Mode ONLY
The factory installed jumper between "R" and "BK" on the circuit board must be cut if an optional humidistat is installed.
HUMIDISTAT HOOKUP - 24 V ONLY
If an optional humidistat for humidity control in cooling is used, the factory installed "BK Jumper" must be cut.
The BK Jumper must also be cut if a multi-zone control-
lerisconnectedto*CONT402isinstalledandusingthe
BK enabled feature.
See the 24VAC field wiring diagrams for mor informa­tion.
28
Pub. No. 22-1840-14
Page 29
(ALL DIMENSIONS ARE IN INCHES)
TUHM-ACV Outline Drawing
Ø 1-5/8” HOLE WITH PLUG
Ø 1-5/8” HOLE WITH PLUG
22-11/16”
Ø 7/8” HOLE WITH PLUG
CONDENSATE DRAIN
(ALTERNATIVE)
28-1/”4
DIM "A" DIM "B" DIM "C" DIM "D" DIM "E" DIM "F"
MODEL
(SEE NOTE 1)
17-1/2" 2-1/4" 16-1/4" 16" 7-1/2" 2"
*UHMB060ACV3VB
*UHMB080ACV3VB
NOTES:
1. DIAMETER OF VENT PIPE MAY BE LIMITED
TO2-1/2"OR3"ONSOMEMODELSATDIFFERENT
ALTITUDES. REFER TO THE VENT LENGTH TABLE
FOR PROPER APPLICATION.
*UHMC100AC4VB 21" 2-1/2" 19-3/4" 19-1/2" 9" 3"
*UHMD120AC5VB 24-1/2" 2-15/16" 23-1/4" 23" 10" 3"
Pub. No. 22-1840-14
Ø 7/8” HOLE WITH PLUG
1-3/4” X 2-13/32” CUTOUT
HORIZONTAL DRAIN
CONDENSATE DRAIN
29
Page 30
1-1/2 x 2-1/2 OVAL
GAS CONNECTION
Ø 1-5/8” HOLE WITH PLUG
(ALL DIMENSIONS ARE IN INCHES)
TDHM-ACV DOWNFLOW/ HORIZONTAL OUTLINE DRAWING
1-3/4 X 2-13/32 CUTOUT
HORIZONTAL DRAIN
1-5/8” HOLE WITH PLUG
20-1/4”
DIM "A" DIM "B" DIM "C" DIM "D"
MODEL
(SEE NOTE 1)
*DHMB060ACV3VB
Ø 1-5/8” HOLE WITH PLUG
CONDENSATE DRAIN
Ø 1-5/8” HOLE WITH PLUG
GAS CONNECTION
(ALTERNATE)
17-1/2" 2-1/4" 16-1/4" 16"
*DHMB080ACV3VB
*DHMB060BCV3VB
24-1/2" 2-15/16" 23-1/4" 23"
*DHMC100ACV4VB 21" 2-1/2" 19-3/4" 19-1/2"
*DHMD120ACV5VB
*DHMD120BCV5VB
30
Pub. No. 22-1840-14
Page 31
Notes
Pub. No. 22-1840-14
31
Page 32
Trane
6200 Troup Highway Tyler, TX 75707 www.trane.com
Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.