Trane MS-SVN015-EN User Manual

Installation Manual
TM
NEW STYLUS
Split System, 1-5 Tons Convertible Type MCX Series 50/60 Hz
50 Hz Models Cooling Only
MCX 512 GB MCX 518 GB MCX 524 GB MCX 530 GB MCX 536 GB MCX 042 GB MCX 048 GB MCX 060 GB
60 Hz Models Cooling Only
MCX 512 G1 MCX 518 G1 MCX 524 G1 MCX 530 G1 MCX 536 G1 MCX 042 G1 MCX 048 G1 MCX 060 G1
MS-SVN015-EN.p65 6/27/07, 11:23 AM1
Black
July 2007 MS-SVN015-EN
General Information
General Information
This Installation Manual is given as a guide to good practice in the installation by the installer of MCX mini-split system. Installation procedures should be performed in the sequence that they appear in this manual.
For installing the unit to operate properly and reliably, it must be installed in accordance with these instructions. Also, the services of a qualified service technician should be employed, through the maintenance contract with a reputable service company.
Read these Installation Instructions completely before installing the air conditioning system.
About this Manual
Cautions appear at appropriate places in this Instruction Manual. Your personal safety and the proper operation of this machine require that you follow them carefully. The Trane Company assumes no liability for installations or servicing performed by unqualified personnel. All phases of the installation of this air conditioning system must conform to all national, provincial, state and local codes.
About the Unit
These MCX units are assembled, pressure tested, dehydrated, charged and run tested before shipment. The information contained in this manual applies to MCX units are designed to operate in cooling mode only and in cooling or heating modes.
Trane MCX series of mini-split systems offer three styles of installation: floor, low wall and under ceiling with both LCD wireless remote control or wired control. Trane MCX series provide flexibility and savings. Note: For model MCX 042, MCX 048 and MCX 060, there are only two styles of installation: under ceiling and low wall.
Reception
On arrival, inspect the unit before signing the delivery note. Specify any damage of the unit on the delivery note, and send a registered letter of protest to the last carrier of the goods within 72 hours of delivery. Notify the dealer at the same time.
The unit should be totally inspected within 7 days of delivery. If any concealed damage is discovered, send a registered letter of protest to the carrier within 7 days of delivery and notify the dealer.
Warning
Warnings are provided at appropriate places in this manual to indicate to installers, operators and service personnel of potentially hazardous situations which, if not avoided, COULD result in death or serious injury.
Caution
Cautions are provided at appropriate places in this manual to indicate to installers, operators, and service personnel of potentially hazardous situations which, if not avoided, MAY result in minor or moderate injury or malfunction of the unit.
Warranty
Warranty is based on the general terms and conditions by country. The warranty is void if the equipment is modified or repaired without the written approval of The Trane Company, if the operating limits are exceeded or if the control system or the electrical wiring is modified.
Damage due to inappropriate installation, lack of knowledge or failure to comply with the manufacturer’s instructions, is not covered by the warranty obligation. If the installation does not conform to the rules described in Installation Manual, it may entail cancellation of warranty and liabilities by The Trane Company.
Important
This document is customer property and is to remain with unit. Please place in service information pack upon completion of work. These instructions do not cover all variations in systems, nor do they provide for every possible contingency to be met in connection with installation. Should further information be desired or should particular problems arise which are not covered sufficiently in this manual, the matter should be referred to your authorized Trane dealer.
MS-SVN015-EN.p65 6/27/07, 11:23 AM2
Black
MS-SVN015-EN© American Standard Inc. 2005
Contents
General Information 2 Typical Installation 4 Location and Preparation of Units 5 Unit Installation 6 Connection of Refrigerant Tubing 7 Condensate Drain Piping 9 Electrical Installation 10 Remote Control Installation 11 Typical Wiring Diagram 12 Dimensional Data 16 Notes 18
MS-SVN015-EN.p65 6/27/07, 11:59 AM3
Black
3MS-SVN015-EN
Typical Installation
Return air grille contains air filter
Indoor unit
Supply air grille Adjustable louvers direct air
Supply air grille Adjustable louvers direct air
Ceiling mounted
Refrigerant tubing/wiring
Outdoor unit
Drain
Return air grille contains air filter
Low wall mounted
Note: For models MCX 042, MCX 048, MCX 060
there are only two styles of installation: under ceiling and low wall
4 MS-SVN015-EN
MS-SVN015-EN.p65 6/27/07, 11:23 AM4
Black
Floor mounted
Location and Preparation of Units
1. Select an appropriate position that allows every corners of the room to be uniformly air conditioned and where it is easy to route the refrigerant tubing.
2. Ensure that the floor or ceiling construction is sufficient to fully support the weight of the indoor unit.
3. Consideration must be given to assure an unobstructed flow of supply and return air.
4. Refrigerant tubes between indoor and outdoor units should be as short as possible.
5. Length of the condensate drain hose should be kept as short as possible (Figure 1).
Figure 1
6. Recommended service clearance as shown in figure 2, 3 and 4.
Min.
20 cm.
Min.
20 cm.
Maintenance area (Celling mounted)
Min.
20 cm.
Figure 2
Maintenance area (Floor mounted)
Min.
30 cm.
Min.
30 cm.
Min. 120 cm.
Min.
30 cm.
Min.
20 cm.
Maintenance area
(Low wall mounted)
Min.
20 cm.
Figure 4
7. Do not install unit in direct sunlight or near other heat sources as this may affect performance. Do not allow outside air to directly enter unit or condensate may form at the unit’s discharge.
Note: For MCX042-MCX060 the unit should be installed over the floor at least 20 cm.
MS-SVN015-EN.p65 6/27/07, 11:23 AM5
Black
Figure 3
5MS-SVN015-EN
0.83"(21)
0.83"(21)
8.5"(215)
B
A
Unit Installation
Indoor Unit
1. Select a location to route tubing, wiring and drain pipe between the indoor and outdoor units.
2. Make a hole in the wall using a key hole saw or hole-cutting drill attachment. The hole should be made at a slight downward slant to the outdoor side (Figure 5).
Outdoor side
Indoor side
Figure 5
Before cutting, check that no pipes or studs are directly behind the place to be cut. Avoid areas where electrical wiring or conduits are located.
3. Place the unit on a solid and level foundation.
4. Tubing, wiring through and drain pipe of low wall and floor mounted units can be routed, rear or right side of unit when facing front. Ceiling mounted can be routed straight downward. Pull air filters upward (Figure 6).
5.
6. Unscrew at the return grille (Figure 7).
Figure 7
7. Unscrew at the grille bottom hinges, pull out the screw, and unscrew at the side panel front (Figure 8). Then, push down on
panel front and pull up
the side (Figure 9).
Figure 8
Figure 10
Note: = A 0.49" x 1.575" - 4 SLOT
(Mounting hole) (12.5 mm 40.0 mm)
Unit Size B MCX 512-518 36.2" (920) MCX 524 46.1" (1,170) MCX 530-536 55.9" (1,420) MCX 042-048 65.7" (1,670) MCX 060 75.6" (1,920)
8. Place or hang the unit at the selected position.
9. Replace both right and left side panels, and the return grille after the installation of wiring, tubing and piping is complete.
Outdoor Unit
See the proper installation method provided in the Installation Manual for the outdoor unit.
Pull
Pull
Figure 6
6 MS-SVN015-EN
MS-SVN015-EN.p65 6/27/07, 11:23 AM6
Black
Figure 9