Trane offers a complete family of packaged gas/electric heating and cooling systems, designed to give you the unbeatable combination of energy efficiency and
lower operating costs. In warm weather, the packaged gas/electric system functions
as an all-electric, high efficiency air conditioner. In cold weather, it operates as a
natural gas or propane gas furnace, offering you the best of both energy worlds.
Introducing the new TRANE Single Packaged Convertible
Gas/Electric System.
Single Packaged Convertible Gas/
Electric Systems are easy and versatile to install. Because cooling and
heating functions are all contained in a
single cabinet, a Trane single packaged
convertible gas/electric system is easy to
install and service. It can be flush
mounted beside your home at ground
level or placed on the roof for horizontal
or downflow installation. When connected
to an optional Trane thermostat control,
and air distribution ducts, you have a
highly efficient, total home comfort
system.
Single Packaged Convertible Gas/
Electric Systems are unmatched in
quality and reliability. All major
components on these products,
including the compressor, have been
designed and manufactured for
maximum service. Every Climatuff
compressor is designed and manufactured to exacting specifications. Each
design is life tested in extreme environments to ensure reliable and long
lasting operation in normal applications.
Each compressor has internal motor
protection for added reliability.
2
®
Contents
Optional Equipment Listing4
General Data5
Performance Data
Cooling9
Indoor Fan11
Typical Wiring15
Optional Equipment18
Dimensional Data23
Mechanical Specifications29
3
Optional Equipment Listing
OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [
Hinged Filter Access Door (4YCY4024-036) 8 ................................................................ BAYACCDOR1A[ ]
Hinged Filter Access Door (4YCY4042-060) 8 ................................................................ BAYACCDOR2A[ ]
Roof Curb Full Perimeter (4YCY4024-36A) 3 ................................................................... BAYCURB050A[ ]
Roof Curb Full Perimeter (4YCY4042-60A) 3 ................................................................... BAYCURB051A[ ]
NOTES:1 Must use filter frame when economizer/fresh air kit is used.
2 Dry bulb control standard with economizer.
3 Ships knocked down.
4 Downflow only.
5 Low Ambient cooling requires crankcase heater (BAYCCHT----A).
6 It is the responsibility of the installing dealer to properly size the ductwork for each specific application.
7 BAYCOVR112,118A will not cover BAYSQRD002A applications
8 BAYACCDOR1A requires BAYFLTR101B & BAYACCDOR2A requires BAYFLTR201B. They are not
backward compatible to BAYFLTR101/201A.
4
MODEL
RATED Volts/PH/Hz
Performance Cooling BTUHj
Indoor Airflow (CFM)
Power Input (KW)
EER/SEER(BTU/Watt-Hr.)n
Dia x Width (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.n
SEE FAN PERF TABLE
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
COMBUSTION FAN — TYPE
Drive/No. Speeds
Motor — HP/R.P.M.
Volts/Ph/Hz
FLA
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft.)o
REFRIGERANT
Charge (lbs.)m
GAS PIPE SIZE (in.)
DIMENSIONS
Crated (in.)
WEIGHT
Shipping (lbs.) / Net (lbs.)
4YCY4024A1064A
208-230/1/60
23400
790
2.162
11.6 / 14.0
68
48000
64000
79.0
35 / 65
2 / #37
208-230/1/60
16.5
25
25
RECIPROCATING
208-230/1/60
8.3 / 57.8
SPINE-FIN
2 / 24
13.32
3/8
PLATE FIN
3 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
1/12 / 810
208-230/1/60
0.54 / 0.95
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
4.0
R410A
5.8
1/2
H X W X L
45.86 / 44.5 / 52.03
481 / 385
General Data
4YCY4030A1075A
208-230/1/60
30000
900
2.5
12.0 / 14.0
71
56250
75000
79.5
30 / 60
2 / #33
208-230/1/60
19.2
30
30
RECIPROCATING
200-230/1/60
11.1 / 63
SPINE-FIN
2 / 24
15.49
3/8
PLATE FIN
3 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
1/6 / 830
208-230/1/60
1.0 / 1.7
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERF TABLE
1/2 / VARIABLE
208-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
4.0
R410A
6.0625
1/2
H X W X L
45.86 / 44.5 / 52.03
481 / 385
4YCY4036A1075A
208-230/1/60
36000
1210
3.284
11.6 / 14.2
69
56250
75000
79.5
30 / 60
2 / #33
208-230/1/60
24.6
40
40
SCROLL
208-230/1/60
15.4 / 83
SPINE-FIN
2 / 24
15.49
3/8
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
1/5 / 830
208-230/1/60
1.1 / 1.9
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERF TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
4.0
R410A
6.75
1/2
H X W X L
47.86 / 44.5 / 52.03
488 / 392
4YCY4036A1096A
208-230/1/60
36000
1210
3.284
11.6 / 14.2
69
72000
96000
80.0
40 / 70
3 / #37
208-230/1/60
24.6
40
40
SCROLL
208-230/1/60
15.4 / 83
SPINE-FIN
2 / 24
15.49
3/8
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
1/5 / 830
208-230/1/60
1.1 / 1.9
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERF TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
4.0
R410A
6.75
1/2
H X W X L
47.86 / 44.5 / 52.03
493 / 397
11
1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I.
11
Standard 270.
22
2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation.
22
33
3 Convertible to LPG.
33
44
4 This value is approximate. For more precise value, see Unit Nameplate.
44
55
5 Based on U.S. Government Standard Tests.
55
66
6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation
66
with a clean resistance of 0.05" W.C.
77
7 Unit is shipped on high input, unit is convertible to low input with a Low Fire accessory kit.
77
88
8 Sound Power values are not adjusted for ARI 270-95 tonal corrections.
88
5
MODEL
RATED Volts/PH/Hz
Performance Cooling BTUHj
Indoor Airflow (CFM)
Power Input (KW)
EER/SEER(BTU/Watt-Hr.)n
Dia x Width (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.n
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
COMBUSTION FAN — TYPE
Drive/No. Speeds
Motor — HP/R.P.M.
Volts/Ph/Hz
FLA
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft.)o
REFRIGERANT
Charge (lbs.)m
GAS PIPE SIZE (in.)
DIMENSIONS
Crated (in.)
WEIGHT
Shipping (lbs.) / Net (lbs.)
General Data
4YCY4036A3075A
208-230/3/60
36000
1210
3.284
11.6 / 14.2
69
56250
75000
80.0
30 / 60
2 / #33
208-230/3/60
19.8
30
30
SCROLL
208-230/3/60
11.5 / 77
SPINE-FIN
2 / 24
15.49
3/8
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
1/5 / 830
208-230/1/60
1.1 / 1.9
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERF TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
4.0
R410A
6.75
1/2
H X W X L
47.86 / 44.5 / 52.03
488 / 392
4YCY4036A3096A
208-230/3/60
36000
1210
3.284
11.6 / 14.2
69
72000
96000
80.0
40 / 70
3 / #37
208-230/3/60
19.8
30
30
SCROLL
208-230/3/60
11.5 / 77
SPINE-FIN
2 / 24
15.49
3/8
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
1/5 / 830
208-230/1/60
1.1 / 1.9
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERF TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
4.0
R410A
6.75
1/2
H X W X L
47.86 / 44.5 / 52.03
493 / 397
4YCY4042A1096A
208-230/1/60
42000
1350
3.5
12.0 / 14.25
74
72000
96000
80
30 / 60
3 / #37
208-230/1/60
31.5
50
50
SCROLL
208-230/1/60
18.6 / 105
SPINE-FIN
2 / 24
23.57
3/8
PLATE FIN
3 / 15
5
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
1/4 / 825
208-230/1/60
1.5 / 3.4
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERF TABLE
3/4 / VARIABLE
208-230/1/60
6.8 / 6.8
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
5.3
R410A
6.8125
1/2
H X W X L
47.86 / 47.4 / 61.75
653 / 525
11
1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I.
11
Standard 270.
22
2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation.
22
33
3 Convertible to LPG.
33
44
4 This value is approximate. For more precise value, see Unit Nameplate.
44
55
5 Based on U.S. Government Standard Tests.
55
66
6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation
66
with a clean resistance of 0.05" W.C.
77
7 Unit is shipped on high input, unit is convertible to low input with a Low Fire accessory kit.
77
88
8 Sound Power values are not adjusted for ARI 270-95 tonal corrections.
88
6
MODEL
RATED Volts/PH/Hz
Performance Cooling BTUHj
Indoor Airflow (CFM)
Power Input (KW)
EER/SEER(BTU/Watt-Hr.)n
Dia x Width (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.n
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
COMBUSTION FAN — TYPE
Drive/No. Speeds
Motor — HP/R.P.M.
Volts/Ph/Hz
FLA
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft.)o
REFRIGERANT
Charge (lbs.)m
GAS PIPE SIZE (in.)
DIMENSIONS
Crated (in.)
WEIGHT
Shipping (lbs.) / Net (lbs.)
General Data
4YCY4048A1096A
208-230/1/60
48000
1605
4.034
11.9 / 14.2
73
72000
96000
80.0
30 / 60
3 / #37
208-230/1/60
33.8
50
50
SCROLL
208-230/1/60
20.5 / 109
SPINE-FIN
2 / 24
18.01
3/8
PLATE FIN
3 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
1/4 / 825
208-230/1/60
1.4 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERF TABLE
3/4 / VARIABLE
200-230/1/60
6.8 / 6.8
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
5.3
R410A
8.2
1/2
H X W X L
47.86 / 47.4 / 61.75
653 / 525
4YCY4048A1120A
208-230/1/60
48000
1605
4.034
11.9 / 14.2
73
90000
120000
80.0
40 / 70
3 / #32
208-230/1/60
33.8
50
50
SCROLL
208-230/1/60
20.5 / 109
SPINE-FIN
2 / 24
18.01
3/8
PLATE FIN
3 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
1/4 / 825
208-230/1/60
1.4 / 3.37
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERF TABLE
3/4 / VARIABLE
200-230/1/60
6.8 / 6.8
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
5.3
R410A
8.2
1/2
H X W X L
47.86 / 47.4 / 61.75
659 / 531
4YCY4048A3096A
208-230/3/60
48000
1605
4.034
11.9 / 14.2
73
72000
96000
80.0
30 / 60
3 / #37
208-230/3/60
26.4
40
40
SCROLL
208-230/3/60
14.6 / 91
SPINE-FIN
2 / 24
18.01
3/8
PLATE FIN
3 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
1/4 / 825
208-230/1/60
1.4 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERF TABLE
3/4 / VARIABLE
200-230/1/60
6.8 / 6.8
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
5.3
R410A
8.2
1/2
H X W X L
47.86 / 47.4 / 61.75
653 / 525
11
1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I.
11
Standard 270.
22
2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation.
22
33
3 Convertible to LPG.
33
44
4 This value is approximate. For more precise value, see Unit Nameplate.
44
55
5 Based on U.S. Government Standard Tests.
55
66
6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation
66
with a clean resistance of 0.05" W.C.
77
7 Unit is shipped on high input, unit is convertible to low input with a Low Fire accessory kit.
77
88
8 Sound Power values are not adjusted for ARI 270-95 tonal corrections.
88
7
MODEL
RATED Volts/PH/Hz
Performance Cooling BTUHj
Indoor Airflow (CFM)
Power Input (KW)
EER/SEER(BTU/Watt-Hr.)n
Dia x Width (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.n
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
COMBUSTION FAN — TYPE
Drive/No. Speeds
Motor — HP/R.P.M.
Volts/Ph/Hz
FLA
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft.)o
REFRIGERANT
Charge (lbs.)m
GAS PIPE SIZE (in.)
DIMENSIONS
Crated (in.)
WEIGHT
Shipping (lbs.) / Net (lbs.)
General Data
4YCY4048A3120A
208-230/3/60
48000
1605
4.034
11.9 / 14.2
73
90000
120000
80.0
40 / 70
3 / #32
208-230/3/60
26.4
40
40
SCROLL
208-230/3/60
14.6 / 91
SPINE-FIN
2 / 24
18.01
3/8
PLATE FIN
3 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
1/4 / 825
208-230/1/60
1.4 / 3.37
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERF TABLE
3/4 / VARIABLE
200-230/1/60
6.8 / 6.8
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
5.3
R410A
8.2
1/2
H X W X L
47.86 / 47.4 / 61.75
659 / 531
4YCY4060A1120A
208-230/1/60
58500
1800
5.478
11.9 / 14.0
76
90000
120000
80.0
30 / 60
3 / #32
208-230/1/60
42.3
60
60
SCROLL
208-230/1/60
26.9 / 145
SPINE-FIN
2 / 24
23.07
3/8
PLATE FIN
4 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
1/3 / 830
208-230/1/60
1.7 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERF TABLE
1 / VARIABLE
208-230/1/60
6.9 / 6.9
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
5.3
R410A
9.75
1/2
H X W X L
51.86 / 47.4 / 61.75
676 / 548
4YCY4060A3120A
208-230/3/60
58500
1800
5.478
11.9 / 14.0
76
90000
120000
80.0
30 / 60
3 / #32
208-230/3/60
30.6
45
45
SCROLL
208-230/3/60
17.6 / 123
SPINE-FIN
2 / 24
23.07
3/8
PLATE FIN
4 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
1/3 / 830
208-230/1/60
1.7 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERF TABLE
1 / VARIABLE
208-230/1/60
6.9 / 6.9
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
5.3
R410A
9.75
1/2
H X W X L
51.86 / 47.4 / 61.75
676 / 548
11
1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I.
11
Standard 270.
22
2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation.
22
33
3 Convertible to LPG.
33
44
4 This value is approximate. For more precise value, see Unit Nameplate.
44
55
5 Based on U.S. Government Standard Tests.
55
66
6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation
66
with a clean resistance of 0.05" W.C.
77
7 Unit is shipped on high input, unit is convertible to low input with a Low Fire accessory kit.
77
88
8 Sound Power values are not adjusted for ARI 270-95 tonal corrections.
88
8
Performance Data Cooling
4YCY4030A1 AT 1000 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
LOW8750.970.98
HIGH11251.031.02
CFMCAPACITY (A) TESTSEEREER
8903000014.0012.00
ARI STANDARD 210/240 RA TING CONDITIONS — (A) Cooling 80°F DB, 67°F
WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High
Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air
entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating
is the same as for cooling.
AIR FLOWCAPACITYTOTAL POWER
RATE, CFMMULTIPLIERMULTIPLIER
ARI RATING FOR COOLING
ARI Standard Capacity Rating Conditions
4YCY4024A1 AT 800 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
LOW7000.970.98
HIGH9001.031.02
CFMCAPACITY (A) TESTSEEREER
7902340014.0011.60
ARI STANDARD 210/240 RA TING CONDITIONS — (A) Cooling 80°F DB, 67°F
WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High
Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air
entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating
is the same as for cooling.
AIR FLOWCAPACITYTOTAL POWER
RATE, CFMMULTIPLIERMULTIPLIER
ARI RATING FOR COOLING
ARI Standard Capacity Rating Conditions
4YCY4036A1/3 AT 1200 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
LOW10500.970.98
HIGH13501.031.02
CFMCAPACITY (A) TESTSEEREER
12103600014.2011.60
ARI STANDARD 210/240 RA TING CONDITIONS — (A) Cooling 80°F DB, 67°F
WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High
Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air
entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating
is the same as for cooling.
AIR FLOWCAPACITYTOTAL POWER
RATE, CFMMULTIPLIERMULTIPLIER
ARI RATING FOR COOLING
ARI Standard Capacity Rating Conditions
9
Performance Data Cooling
4YCY4042A1 AT 1400 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
LOW12250.970.98
HIGH15751.031.02
CFMCAPACITY (A) TESTSEEREER
13604200014.2512.00
ARI STANDARD 210/240 RA TING CONDITIONS — (A) Cooling 80°F DB, 67°F
WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High
Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air
entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating
is the same as for cooling.
AIR FLOWCAPACITYTOTAL POWER
RATE, CFMMULTIPLIERMULTIPLIER
ARI RATING FOR COOLING
ARI Standard Capacity Rating Conditions
4YCY4048A1/3 AT 1600 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
LOW14000.970.98
HIGH18001.031.02
CFMCAPACITY (A) TESTSEEREER
16054800014.2011.90
ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F
WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High
Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air
entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating
is the same as for cooling.
AIR FLOWCAPACITYTOTAL POWER
RATE, CFMMULTIPLIERMULTIPLIER
ARI RATING FOR COOLING
ARI Standard Capacity Rating Conditions
4YCY4060A1/3 AT 2000 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
LOW17500.970.98
HIGH22501.031.02
CFMCAPACITY (A) TESTSEEREER
17995850014.0011.90
ARI STANDARD 210/240 RA TING CONDITIONS — (A) Cooling 80°F DB, 67°F
WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High
Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air
entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating
is the same as for cooling.
Heating Airflow, horizontal or downflow from .2 to .6” wg.
4YCY4024A1064
Switch SettingsNominal Airflow
7-OFF8-OFFA600850
7-ON8-OFFB625900
7-OFF8-ONC650925
7-ON8-OND700975
Selection
Low Stage High Stage
4YCY4030A
Switch SettingsNominal Airflow
Selection
Low Stage High Stage
7-OFF8-OFFA7251000
7-ON8-OFFB7751075
7-OFF8-ONC8501150
7-ON8-OND9251250
4YCY4036A*075
Switch SettingsNominal Airflow
Selection
Low Stage High Stage
7-OFF8-OFFA7251000
7-ON8-OFFB7751075
7-OFF8-ONC8501150
7-ON8-OND9251250
* can be 1 or 3
4YCY4036A*096
Switch SettingsNominal Airflow
Selection
Low Stage High Stage
7-OFF8-OFFA8251100
7-ON8-OFFB8751175
7-OFF8-ONC9501275
7-ON8-OND10251375
* can be 1 or 3
4YCY4042A
Switch SettingsNominal Airflow
Selection
Low Stage High Stage
7-OFF8-OFFA10751375
7-ON8-OFFB11001450
7-OFF8-ONC11501500
7-ON8-OND12001575
4YCY4048A*096
Switch SettingsNominal Airflow
7-OFF8-OFFA10751375
7-ON8-OFFB11001450
7-OFF8-ONC11501500
7-ON8-OND12001575
Switch Settings
7-OFF8-OFFA10501500
7-ON8-OFFB11001575
7-OFF8-ONC11501625
7-ON8-OND12001700
Switch SettingsSelection
7-OFF8-OFFA13751800
7-ON8-OFFB14501900
7-OFF8-ONC15251975
7-ON8-OND15752075
Selection
Low Stage High Stage
* can be 1 or 3
4YCY4048A*120
Selection
Low Stage High Stage
* can be 1 or 3
4YCY4060A
Low Stage High Stage
Nominal Airflow
Nominal Airflow
14
GROUND
WIRE
1 PH
POWER
3 PH
POWER
UNIT
NOTE 1
Typical Field Wiring
UNIT CONTROL BOX
B
COMMON
(GR)
FAN
G
Y
COMPRESSOR
HEAT FIRST STAGE
W1
HEAT SECOND STAGE
W2
R
24V
(WH)
(WH)
COMMON
B
FAN
(GR)
G
COMPRESSOR
Y
HEAT FIRST STAGE
W1
HEAT SECOND STAGE
W2
24V
R
(WH)
(WH)
B
G
Y
W1
W2
R
(GR)
(WH)
(WH)
C 757192i2
15
Typical Wiring
16
Typical Wiring
From Dwg. 21D757165 P02
17
Optional Equipment
BAYCURB050A Full Perimeter Roof Mounting Curb for *****018-036A
17 7/8
46 3/8
3
19 1/2
2 3/16
19 1/2
15
3 5/8
38 7/8
14
1 1/2
The drawings on this page are prepared by the
manufacturer in order to provide detail regarding
job layout only. These drawings are not intended to
be used as a basis to construct, build or modify the
items depicted in the drawings. The manufacturer is
not responsible for the unauthorized use of these
drawings and expressly disclaims any liability for
damages resulting from such unauthorized use.
35 7/8
43 3/8
18
1 1/2
Optional Equipment
BAYCURB051A Full Perimeter Roof Mounting Curb for *****042-060A
15 7/8
56 1/8
3
10 7/8
19 1/2
20
41 7/8
4 3/4
19 1/2
14
The drawings on this page are prepared by the
manufacturer in order to provide detail regarding
job layout only. These drawings are not intended to
be used as a basis to construct, build or modify the
items depicted in the drawings. The manufacturer is
not responsible for the unauthorized use of these
drawings and expressly disclaims any liability for
damages resulting from such unauthorized use.
38 7/8
53 1/8
19
Optional Equipment
BAYFLTR101, 201B, 1" - 2" Filter Rack
(Mounts in Filter/Coil Section)
Filter
BAYACCDOR1A & BAYACCDOR2A Hinged Filter Access Door
Replaces Filter/Coil Access Panel
The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings
are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not
responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such
unauthorized use.
20
Optional Equipment
BAYECON101,102A Down Discharge Economizer and Rain Hood
(Mounts Over Horizontal Return Air Opening)
HVAC Unit
A
Economizer
rain hood
EconomizerUnit ApplicationM odelsA
Mist
eliminator
Relief
damper
Roofcurb
BAYECON200,201A Horizontal Economizer and Rain Hood
The drawings on this page are
prepared by the manufacturer in
order to provide detail regarding job layout only. These
drawings are not intended to be
used as a basis to construct,
build or modify the items
depicted in the drawings. The
manufacturer is not responsible
for the unauthorized use of
these drawings and expressly
disclaims any liability for
damages resulting from such
unauthorized use.
Return air
dampers
Economizer
Duct
Outside air
dampers
C
Required filter
kit, order
separately
Return
Duct
A
B
D
BAYECON101A
BAYECON102A
2/4YC,WC3018-036A
4TC*3018-036A
4W/T/Y/DCY4024-060
2/4YC,WC3042-060A
4TC*3042-060A
4W/T/Y/DCY4024-060
Gaskets (2)
20.125"
24.375"
Rain Hood
E
EconomizerABCDE
BAYECON200AA22"20"16 7/8"15 11/1611 11/16
BAYECON201AA24"22 21/32"19"17 11/1614 11/16
Mixed Air Sensor
21
Optional Equipment
BAYOSAH001,002A, 25% Outside Air Damper
(Replaces Filter/Coil Access Panel)
The drawings on this page are prepared
by the manufacturer in order to provide
detail regarding job layout only. These
drawings are not intended to be used as
a basis to construct, build or modify the
items depicted in the drawings. The
manufacturer is not responsible for the
unauthorized use of these drawings and
expressly disclaims any liability for
damages resulting from such unauthorized use.
Manual Fresh
Air Model
BAYOSAH001
BAYOSAH002
Unit Application
Models
2/4YC,WC3018-036A
4TC*3018-036A
4W/T/Y/DCY4024-036A
4W/Y/DCZ6036A
2/4YC,WC3042-060A
4TC*3042-060A
4W/T/Y/DCY4042-060
4W/Y/DCZ6048-060A
22 7/16"20 11/16"12 3/8"9 3/16"
25 3/16"20 11/16"12 3/8"9 3/16"
D
ABCD
C
A
FULLY
OPEN
2/3
1/3
FULLY
B
CLOSED
BAYDMPR101A
BAYDMPR102A
BAYDMPR101,102A, 25% Motorized Outside Air Damper
Unit Application
Models
2/4YC,WC3018-036A
4TC3018-036A
4W/T/Y/DCY4024-036A
4W/Y/DCZ6036A
2/4YC,WC3042-060A
4TC3042-060A
4W/T/Y/DCY4042-060A
4W/Y/DCZ6048-060A
(Mounts Over Horizontal Return AIr Opening)
A
E
ABCDE
15 13/16" 11 13/16"10 1/4"11 1/2"12 1/4"
18 3/16"15 1/8"10 1/4"11 1/2"12 1/4"
C
B
D
22
Dimensional Data
4YCY4024A through 4YCY4036A (1 of 3)
23
Dimensional Data
4YCY4024A through 4YCY4036A (2 of 3)
24
Dimensional Data
4YCY4024A through 4YCY4036A (3 of 3)
25
Dimensional Data
4YCY4042A through 4YCY4060A (1 of 3)
26
Dimensional Data
4YCY4042A through 4YCY4060A (2 of 3)
27
Dimensional Data
4YCY4042A through 4YCY4060A (3 of 3)
28
Mechanical Specifications
General
All units shall be factory assembled, piped,
internally wired and fully charged with
refrigerant. All units shall be designed to
operate at outdoor ambient temperatures
as high as 115°F. Cooling capacities shall
be rated in accordance with A.R.I.
standards. The 4YCY4 heating/cooling unit
design is UL listed, specifically for outdoor
applications using natural gas or propane.
All units shall be designed for outdoor
rooftop or ground level installation. Unit
casing is constructed of heavy gauge,
galvanized steel and painted with a
weather-resistant powder paint.
Shipped for horizontal application,
convertible to downflow.
Casings
All panels shall be heavy gauge steel,
gasketed and insulated. Foil-faced
insulation shall be in the heat exchanger
section. Foil-faced insulation shall be in the
evaporator section. Base pan shall be
heavy gauge steel. WEATHERGUARD™
exterior corrosion resistant screws shall be
used for added resistance to rust and
corrosion.
Controls
Refrigeration cycle controls shall include
condenser fan, evaporator fan and
compressor contactors. Compressors shall
be equipped with a combination internal
winding thermostat/current overload.
Internal high pressure relief shall also be
provided.
Refrigeration System
Compressors —
The Climatuff
®
compressor features
internal over temperature and pressure
protector, total dipped hermetic motor.
Other features include: roto lock suction
and discharge refrigeration connections,
centrifugal oil pump, and low vibration and
noise.
Evaporator Coil — Internally enhanced
3/8-inch OD seamless copper tubing
mechanically bonded to aluminum fins,
factory pressure and leak tested at 250 to
300 psig. All units have TXV to control
refrigeration flow.
Condenser Coil —
The Spine Fin™ condenser coil shall be
continuously wrapped, corrosion resistant
all aluminum with minimum brazed joints.
This coil is 3/8 inch OD seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand
2,000 pounds of pressure per square inch.
The outdoor coil provides low airflow
resistance and efficient heat transfer. The
coil is protected on all four sides by
louvered panels.
Indoor Air Fan — Direct-drive, forwardcurved, centrifugal wheel in a Composite
Vortica
®
Blower housing. Motor shall
have thermal overload protection.
Permanently lubricated motor bearings.
Motor/blower assembly isolated from unit
with rubber mounts.
Condenser Fan — Direct-drive, draw
through propeller type. Weather-proofed
permanent split capacitor fan motor shall
have built-in thermal overload and
permanently lubricated motor bearings.
Low Ambient — Standard refrigerant
system operation down to 55°F. Low
ambient accessory required for operation
to 0°F ambient condition.
Gas-Fired Heating System — Models
shall provide completely assembled, wired
and piped gas fired heating systems within
unit. Design certified by UL, specifically for
outdoor application. Threaded gas
connection on the unit.
Electronic Ignition System — Main
burner is lit each time thermostat calls for
gas heat. Flame sensor proves flame and
keeps the main burners on. Should a loss
of flame occur, the main valve closes and
the spark recurs within 0.8 second. When
thermostat is satisfied, main burner is
extinguished.
Forced Combustion Blower — Insures
flame stability under varying wind
conditions. Gives higher combustion
efficiency and location flexibility.
be designed to mate with the unit
and provide support and complete
weather-tight installation when
properly installed. Curb shall ship
knocked down for field assembly,
and include wood nailer strips.
Modulating Economizer — This
accessory shall be field installed
and be composed of the following
items: 0-100% fresh air damper,
damper drive motor fixed dry bulb
enthalpy control, and low voltage
polarized plug for electrical
connections. Solid state enthalpy or
differential enthalpy control is
optional. Economizer operations
shall be controlled by the preset
position of the enthalpy control. A
barometic relief damper shall be
standard with the economizer and
provide a pressure operated
damper that shall be gravity closing
and prohibit entrance of outside air
on equipment “off” cycle.
Manual Fresh Air Hood
Manual outside air provides a fixed
outside air quantity from 0 to 25
percent. Includes hood and
birdscreen.
Low Ambient Control
Control allows cycling of
compressor under low ambient
cooling conditions. Required for
cooling operation to 0°F.
Propane Gas
Conversion Kit — For conversion
from natural gas to LP gas.
Trane
6200 Troup Highway
Tyler, TX 75707-9010
The manufacturer has a policy of continuous product and product data improvement and it reserves the right to
change design and specifications without notice.
29
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.