Trane 4DCY4024, 4DCY4030, 4DCY4060, 4DCY4036, 4DCY4042 Product Data

...
Product Data
4DCY4024 through 4DCY4060
Packaged Convertible Dual Fuel 14 SEER 2 - 5 Ton, 60 - 120 MBTU
R-410A
© 2014Trane
Pub. No. 22-1799-20-EN
It's Hard to Stop a Trane.
Packaged Convertible Dual Fuel System
Trane offers a complete family of dual fuel heating and cooling systems, de­signed to keep you comfortable all year long, regardless of the weather, while keeping your operating costs as low as possible. The heat pump operates ef­ficiently as both an air conditioner and a heater. In the summer, the heat pump cools your home just like any other air conditioner by pulling the heat from the inside and releasing it outdoors. In the winter, it captures the heat that is al­ways present in the outdoor air and transfers it indoors. The gas furnace pro­vides additional heating capacity for cooler weather.
Introducing the new TRANE Packaged Convertible Dual Fuel System.
Single Packaged Convertible Dual Fuel Systems are easy and versatile to install. Because cooling and heating
functions are all contained in a single cabinet, a Trane packaged dual fuel system is easy to install and service. It can be flush mounted beside your home at ground level or placed on the roof for horizontal or downflow installation. When connected to a *CONT402, 802, or 803 comfort control, and air distribution ducts, you have a highly efficient, total home comfort system.
Single Packaged Dual Fuel Systems are unmatched in quality and reli­ability. All major components on these
products, including the compressor, have been designed and manufactured for maximum service. Every Climatuff® compressor is designed and manufac­tured to exacting specifications. Each design is life tested in extreme envi­ronments to ensure reliable and long lasting operation in normal applications. Each compressor has internal motor protection for added reliability.
2
Contents
Optional Equipment Listing 4
General Data 5
Indoor Blower Performance 8
Typical Wiring 16
Optional Equipment 14
Dimensional Data 19
Mechanical Specifications 25
3
Optional Equipment Listing
OPTIONAL EQUIPMENT FOR 4DCY4 PACKAGED UNITS (check mark [] indicates accessories included)
Hinged Filter Access Door (4DCY4024-036) 8 ................................................................ BAYACCDOR1A[ ]
Hinged Filter Access Door (4DCY4042-060) 8 ................................................................ BAYACCDOR2A[ ]
Roof Curb Full Perimeter (4DCY4024-036) 3 ...................................................................BAYCURB050A[ ]
Roof Curb Full Perimeter (4DCY4042-060) 3 ...................................................................BAYCURB051A[ ]
Roof Curb Utility Extension Kit (BAYCURB050A)....................................................................BAYUTIL101B[ ]
Roof Curb Utility Extension Kit (BAYCURB051A)....................................................................BAYUTIL102B[ ]
0-25% Manual Fresh Air Damper (4DCY4024-36) 1. .......................................................... BAYOSAH001A[ ]
0-25% Manual Fresh Air Damper (4DCY4042-060) 1. ........................................................ BAYOSAH002A[ ]
Motorized Fresh Air Damper (4DCY4024-36) 1. ............................................................... BAYDMPR101A[ ]
Motorized Fresh Air Damper (4DCY4042-060) 1. .............................................................. BAYDMPR102A[ ]
16" Round Duct Adapter (2 per box) (4DCY4024-36) 6 .................................................... BAYSQRD001A[ ]
18" Round Duct Adapter (2 per box) (4DCY4024-060) 6 .................................................. BAYSQRD002A[ ]
0-100% Mod Economizer w/Baro. Relief (4DCY4024-36) 124 ....................................... BAYECON101B[ ]
0-100% Mod. Economizer w/Baro. Relief (4DCY4042-060) 124. .................................... BAYECON102B[ ]
0-100% Horizontal Economizer (4DCY4024-36) 12 . ....................................................... BAYECON200A[ ]
0-100% Horizontal Economizer (4DCY4042-060) 12 . ..................................................... BAYECON201A[ ]
Economizer Relay Kit (required for Heat Pump applications) ................................................BAYRLAY004A[ ]
Enthalpy Control for Economizer (solid state). ...................................................................... BAYENTH001A[ ]
Remote Potentiometer (All-BAYECON***A) ............................................................................. BAYSTAT023[ ]
1"-2" Filter Frame (4DCY4024-36) (20 x 25 filter not included) 1. ........................................ BAYFLTR101B[ ]
1"-2" Filter Frame (4DCY4042-60) (20 x 20 & 20 x18 filter not included) 1. ......................... BAYFLTR201B[ ]
Head Pressure Control (Low Ambient Cool) (208/240v) Kit 5. ...........................................BAYLOAM105A[ ]
Quick Start Kit (4DCY4-‡1) .................................................................................................. BAYQSKT300A[ ]
Crankcase Heater Recip (4DCY4024, 30)(230v) 5. ............................................................BAYCCHT101A[ ]
Crankcase Heater Scroll(4DCY4042, 48, 60)(230v) 5. .......................................................BAYCCHT102A[ ]
Crankcase Heater Scroll(4DCY4036)(230v) 5. ...................................................................BAYCCHT103A[ ]
Adapter Curb 4DCY4024-36 to BAYCURB030,38 .............................................................. BAYADAP050A[ ]
Adapter Curb 4DCY4024-36 to BAYCURB033 ................................................................... BAYADAP051A[ ]
Adapter Curb 4DCY4042-60 to BAYCURB030,38 .............................................................. BAYADAP052A[ ]
Adapter Curb 4DCY4042-60 to BAYCURB033 ................................................................... BAYADAP053A[ ]
Adapter Curb 4DCY4042-60 to BAYCURB034 ................................................................... BAYADAP054A[ ]
12" Duct Shroud Covers Horizontal *DCY4024-607. ..........................................................BAYCOVR112A[ ]
18" Duct Shroud Covers Horizontal *DCY4024-60 7. .........................................................BAYCOVR118A[ ]
Extreme Condition Mounting Kit - All BAYCURB & BAYADAP .............................................BAYEXMK001A[ ]
Extreme Condition Mounting Kit - All BAYUTIL ....................................................................BAYEXMK002B[ ]
Extreme Condition Mounting Kit - All Slab Mounts ...............................................................BAYEXMK003A[ ]
Lifting Lug Kit ...........................................................................................................................BAYLlFT002B[ ]
LP Conversion Kit (All 40K, 120K Models) ...........................................................................BAYLPKT100A[ ]
LP Conversion Kit (All 64K, 96K Models) .............................................................................BAYLPKT101A[ ]
LP Conversion Kit (All 75K Models).......................................................................................BAYLPKT102A[ ]
NOTES: 1 Must use internal filter frame when economizer or fresh air kit is used. 2 Dry bulb control standard with economizer. 3 Ships knocked down. 4 Downflow only. 5 Low Ambient cooling requires crankcase heater (BAYCCHT----A).
6 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 7 BAYCOVR112,118A will not cover BAYSQRD002A applications.
8 BAYACCDOR1A requires BAYFLTR101B & BAYACCDOR2A requires BAYFLTR201B. They are not backward com-
‡ = A or B
patible to BAYFLTR101/201A.
4
General Data
MODEL RATED Volts/PH/Hz Performance Cooling BTUH
Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr.) Sound Power Rating [dB(A)]7
HP Heating Performance
(High Temp.)BTUH / COP Power Input (KW) (Low Temp.) BTUH / COP Power Input (KW) HSPF (BTU / Watt-Hr.)
Gas Heating Performance
(High) Input BTUH Capacity BTUH Temp. Rise — Min/Max (°F) (Low) Input BTUH Capacity BTUH AFUE Type of Gas Gas Pipe Size (in.)
POWER CONN.—V/PH/HZ
Min. Brch. Cir. Ampacity Fuse Size — Max. (amps) Fuse Size — Recmd. (amps)
COMPRESSOR
Volts/Ph/Hz R.L. Amps — L.R. Amps
OUTDOOR COIL — TYPE
Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control
INDOOR COIL — TYPE
Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.)
OUTDOOR FAN — TYPE
Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 7 Motor — HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps
INDOOR FAN — TYPE
Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. Motor — HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps
COMBUSTION FAN — TYPE
Drive/No. Speeds Motor — HP/R.P.M. (High/Low) Volts/Ph/Hz FLA
FILTER / FURNISHED
Type Recommended Recmd. Face Area (sq. ft.)
REFRIGERANT / Charge (lbs.) DIMENSIONS
Crated (in.)
WEIGHT / Shipping / Net (lbs.)
4DCY4024C1060A
208-230/1/60
23600
760
2.162
12/14.0
68
22400 / 3.7
1.77
11600 / 2.38
1.24
8.0
60000 48600
40 / 70
48000 38880
81
NATURAL/LP
1/2
208-230/1/60
16.1 25 25
RECIPROCATING
208-230/1/60
8.3 / 57.8
SPINE-FIN
2 / 24
13.32 3/8
EXPANSION VALVE
PLATE FIN
3 / 15
3.54 3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
2590
1/12 / 810
208-230/1/60
0.54 / 0.95
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34 NO
THROWAWAY
4
R410A / 6.5
H X W X L
45.86 / 44.5 / 52.03 481 / 385
4DCY4030C1070A
208-230/1/60
30000
880
2.15
12.0 / 14.25 71
28000 / 3.9
2.15
15400 / 2.48
1.81
8.0
70000 56700
30 / 60
56000 45360
81
NATURAL/LP
1/2
208-230/1/60
19.1 30 30
RECIPROCATING
200-230/1/60
11.1 / 63
SPINE-FIN
2 / 24
13.32 3/8
EXPANSION VALVE
PLATE FIN
4 / 15
3.54 3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
3250
1/6 / 830
208-230/1/60
1.0 / 1.7
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
208-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34 NO
THROWAWAY
4
R410A / 6.56
H X W X L
45.86 / 44.5 / 52.03 481 / 385
4DCY4036C1070A
208-230/1/60
37000
1150
3.11
12.0 / 14.0 69
33200 / 3.6
2.7
22400 / 2.4
2.5
8.0
70000 56700
30 / 60
56000 45360
81
NATURAL/LP
1/2
208-230/1/60
26.2 40 40
SCROLL
208-230/1/60
16.7 / 79
SPINE-FIN
2 / 24
15.49 3/8
EXPANSION VALVE
PLATE FIN
4 / 15
3.54 3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
3310
1/5 / 830
208-230/1/60
1.1 / 1.9
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34 NO
THROWAWAY
4
R410A / 7.5
H X W X L
47.86 / 44.5 / 52.03 488 / 392
1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI
Standard 210/240.
2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a
rate of 4% per 1000 ft. elevation.
3 Convertible to LPG. 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent
filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C.
7 Sound Power values are not adjusted for AHRI 270-95 tonal corrections.
8 Standard Air — Dry Coil — Outdoor.
5
General Data
MODEL RATED Volts/PH/Hz Performance Cooling BTUH
Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr.) Sound Power Rating [dB(A)]7
HP Heating Performance
(High Temp.)BTUH / COP Power Input (KW) (Low Temp.) BTUH / COP Power Input (KW) HSPF (BTU / Watt-Hr.)
Gas Heating Performance
(High) Input BTUH Capacity BTUH Temp. Rise — Min/Max (°F) (Low) Input BTUH Capacity BTUH AFUE Type of Gas Gas Pipe Size (in.)
POWER CONN.—V/PH/HZ
Min. Brch. Cir. Ampacity Fuse Size — Max. (amps) Fuse Size — Recmd. (amps)
COMPRESSOR
Volts/Ph/Hz R.L. Amps — L.R. Amps
OUTDOOR COIL — TYPE
Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control
INDOOR COIL — TYPE
Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.)
OUTDOOR FAN — TYPE
Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 7 Motor — HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps
INDOOR FAN — TYPE
Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. Motor — HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps
COMBUSTION FAN — TYPE
Drive/No. Speeds Motor — HP/R.P.M. (High/Low) Volts/Ph/Hz FLA
FILTER / FURNISHED
Type Recommended Recmd. Face Area (sq. ft.)
REFRIGERANT / Charge (lbs.) DIMENSIONS
Crated (in.)
WEIGHT / Shipping / Net (lbs.)
4DCY4036B3075A
208-230/3/60
36000
1185
3.28
11.4 / 14.0 69
32400 / 3.5
2.7
20600 / 2.36
2.6
8.0
75000 60500 30 / 60 56250 48400
80.0
NATURAL
1/2
208-230/3/60
18.5 25 25
SCROLL
208-230/3/60
10.4 / 73
SPINE-FIN
2 / 24
15.49 3/8
EXPANSION VALVE
PLATE FIN
4 / 15
3.54 3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
3270
1/5 / 830
208-230/1/60
1.1 / 1.9
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34 NO
THROWAWAY
4
R410A / 7.4
H X W X L
47.86 / 44.5 / 52.03 488 / 392
4DCY4042C1090A
208-230/1/60
42000
1380
3.50
12.0 / 14.0 74
38000 / 3.45
3.23
23400 / 2.32
2.96
8.0
90000 72900
30 / 60
72000 58320
81
NATURAL/LP
1/2
208-230/1/60
30.8 45 45
SCROLL
208-230/1/60
17.9 / 112
SPINE-FIN
2 / 24
18.01 3/8
EXPANSION VALVE
PLATE FIN
3 / 15
5
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
4440
1/4 / 825
208-230/1/60
1.5 / 3.4
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
3/4 / VARIABLE
208-230/1/60
6.8 / 6.8
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34 NO
THROWAWAY
5.3
R410A / 8.2
H X W X L
47.86 / 47.4 / 61.75 653 / 525
4DCY4048C1090B
208-230/1/60
47500
1470
3.96
12.0 / 14.0 73
45000 / 3.5
3.77
26800 / 2.3
3.44
8.0
90000 72900 30 / 60 72000 58320
81
NATURAL/LP
1/2
208-230/1/60
33.9 50 50
SCROLL
208-230/1/60
20.5 / 109
SPINE-FIN
2 / 24
18.01 3/8
EXPANSION VALVE
PLATE FIN
3 / 15
5.0 3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
4450
1/4 / 825
208-230/1/60
1.4 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
3/4 / VARIABLE
200-230/1/60
6.8 / 6.8
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34 NO
THROWAWAY
5.3
R410A / 7.75
H X W X L
47.86 / 47.4 / 61.75 653 / 525
1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI
Standard 210/240.
2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a
rate of 4% per 1000 ft. elevation.
3 Convertible to LPG. 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent
filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C.
7 Sound Power values are not adjusted for AHRI 270-95 tonal corrections.
8 Standard Air — Dry Coil — Outdoor.
6
General Data
MODEL RATED Volts/PH/Hz Performance Cooling BTUH
Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr.) Sound Power Rating [dB(A)]7
HP Heating Performance
(High Temp.)BTUH / COP Power Input (KW) (Low Temp.) BTUH / COP Power Input (KW) HSPF (BTU / Watt-Hr.)
Gas Heating Performance
(High) Input BTUH Capacity BTUH Temp. Rise — Min/Max (°F) (Low) Input BTUH Capacity BTUH AFUE Type of Gas Gas Pipe Size (in.)
POWER CONN.—V/PH/HZ
Min. Brch. Cir. Ampacity Fuse Size — Max. (amps) Fuse Size — Recmd. (amps)
COMPRESSOR
Volts/Ph/Hz R.L. Amps — L.R. Amps
OUTDOOR COIL — TYPE
Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control
INDOOR COIL — TYPE
Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.)
OUTDOOR FAN — TYPE
Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 7 Motor — HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps
INDOOR FAN — TYPE
Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. Motor — HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps
COMBUSTION FAN — TYPE
Drive/No. Speeds Motor — HP/R.P.M. (High/Low) Volts/Ph/Hz FLA
FILTER / FURNISHED
Type Recommended Recmd. Face Area (sq. ft.)
REFRIGERANT / Charge (lbs.) DIMENSIONS
Crated (in.)
WEIGHT / Shipping / Net (lbs.)
4DCY4048A3096C
208-230/3/60
47000
1470
4.03
10.85 / 14.0 73
42500 / 3.5
3.56
26800 / 2.3
3.44
8.0
96000 77500
30 / 60
72000 62000
80
NATURAL
1/2
208-230/3/60
25.3 35 35
SCROLL
208-230/3/60
13.7 / 83.1 SPINE-FIN
2 / 24
18.01 3/8
EXPANSION VALVE
PLATE FIN
3 / 15
5.0 3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
4450
1/4 / 825
208-230/1/60
1.4 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
3/4 / VARIABLE
200-230/1/60
6.8 / 6.8
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34 NO
THROWAWAY
5.3
R410A / 7.75
H X W X L
47.86 / 47.4 / 61.75 653 / 525
4DCY4060C1115A
208-230/1/60
58000
1785
4.83
12.0 / 14.0 76
55000 / 3.6
4.48
35400 / 2.4
4.30
8.0
115000
93150
30 / 60
92000 74520
81
NATURAL/LP
1/2
208-230/1/60
39.9 60 60
SCROLL
208-230/1/60
25 / 134
SPINE-FIN
2 / 24
23.07 3/8
EXPANSION VALVE
PLATE FIN
4 / 15
5.0 3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
5710
1/3 / 830
208-230/1/60
1.7 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1 / VARIABLE 208-230/1/60
6.9 / 6.9
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34 NO
THROWAWAY
6.7
R410A / 11.94
H X W X L
51.86 / 47.4 / 61.75 676 / 548
4DCY4060A3120C
208-230/3/60
57500
1745
5.48
11.5 / 14.0 76
54500 / 3.5
4.56
36400 / 2.48
4.29
8.0
120000
96000
30 / 60
90000 77500
80.0
NATURAL
1/2
208-230/3/60
28.6 45 45
SCROLL
208-230/3/60
16.0 / 110 SPINE-FIN
2 / 24
23.57 3/8
EXPANSION VALVE
PLATE FIN
4 / 15
5.0 3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
1/3 / 830
208-230/1/60
1.7 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1 / VARIABLE 208-230/1/60
6.9 / 6.9
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34 NO
THROWAWAY
6.7
R410A / 10.125
H X W X L
51.86 / 47.4 / 61.75 676 / 548
1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI
Standard 210/240.
2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a
rate of 4% per 1000 ft. elevation.
3 Convertible to LPG. 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent
filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C.
7 Sound Power values are not adjusted for AHRI 270-95 tonal corrections.
8 Standard Air — Dry Coil — Outdoor.
7
Indoor Blower Performance
Selection
Low Stage High Stage
7-OFF 8-OFF A 600 850
7-ON 8-OFF B 625 900
7-OFF 8-ON C 650 925
7-ON 8-ON D 700 975
4DCY4024
Switch Settings Nominal Airflow
Selection
Low Stage High Stage
7-OFF 8-OFF A 725 1000
7-ON 8-OFF B 775 1075
7-OFF 8-ON C 850 1150
7-ON 8-ON D 925 1250
4DCY4030
Switch Settings Nominal Airflow
Indoor Fan Performance 4DCY4024
Horizontal Airflow
4DCY4024-HOR DIPSWITCH SETTINGS External Static Pressure (in. wg)
AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
350 CFM/TON OFF OFF OFF ON
400 CFM/TON* OFF OFF OFF OFF
450 CFM/TON OFF OFF ON OFF
Down Airflow
4DCY4024-DOWN DIPSWITCH SETTINGS External Static Pressure (in. wg)
AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
350 CFM/TON OFF OFF OFF ON
400 CFM/TON* OFF OFF OFF OFF
450 CFM/TON OFF OFF ON OFF
Indoor Fan Performance 4DCY4030
Horizontal Airflow
4DCY4030-HOR DIPSWITCH SETTINGS External Static Pressure (in. wg)
AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
350 CFM/TON OFF OFF OFF ON
400 CFM/TON* OFF OFF OFF OFF
450 CFM/TON OFF OFF ON OFF
Down Airflow
4DCY4030-DOWN DIPSWITCH SETTINGS External Static Pressure (in. wg)
AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
350 CFM/TON OFF OFF OFF ON
400 CFM/TON* OFF OFF OFF OFF
450 CFM/TON OFF OFF ON OFF
Watts 52 66 89 115 140 164 186 206 229 259 -
CFM 706 716 727 733 731 719 700 679 662 659 -
Watts 72 94 120 148 177 207 233 254 267 290 -
CFM 786 793 805 813 813 806 793 780 778 799 -
Watts 80 99 125 153 182 211 243 284 342 - -
CFM 860 862 877 892 903 904 897 884 869 - -
Watts 35 70 90 108 131 160 188 204 225 250 -
CFM 695 729 734 728 721 715 705 679 680 685 -
Watts 79 87 105 129 155 180 206 232 264 306 -
CFM 846 807 802 810 816 813 803 794 800 846 -
Watts 86 102 127 156 185 213 242 275 319 - -
CFM 884 870 882 899 909 907 895 886 898 - -
Watts - 112 155 176 199 231 270 299 289 197 -
CFM - 867 905 904 899 904 914 907 840 650 -
Watts - 157 192 222 249 276 306 343 389 448 -
CFM - 997 1011 1012 1009 1006 1006 1006 1001 982 -
Watts - 213 252 285 317 351 382 401 396 - -
CFM - 1125 1135 1132 1133 1138 1138 1110 1017 - -
Watts - 126 152 182 211 237 263 292 333 397 497
CFM - 883 900 911 911 901 883 863 849 854 890
Watts - 158 196 224 251 283 318 344 345 295 162
CFM - 987 1004 1006 1004 1001 994 977 936 851 697
Watts - 218 254 288 321 354 390 431 480 - -
CFM - 1118 1128 1132 1131 1127 1127 1142 1183 - -
*Factory Default Setting
Auxiliary Heating Airflow, horizontal or downflow from .2 to .6” wg.
8
Loading...
+ 17 hidden pages