Trane offers a complete family of dual fuel heating and cooling systems, designed to keep you comfortable all year long, regardless of the weather, while
keeping your operating costs as low as possible. The heat pump operates efficiently as both an air conditioner and a heater. In the summer, the heat pump
cools your home just like any other air conditioner by pulling the heat from the
inside and releasing it outdoors. In the winter, it captures the heat that is always present in the outdoor air and transfers it indoors. The gas furnace provides additional heating capacity for cooler weather.
Introducing the new TRANE Packaged Convertible Dual Fuel
System.
Single Packaged Convertible Dual
Fuel Systems are easy and versatile
to install. Because cooling and heating
functions are all contained in a single
cabinet, a Trane packaged dual fuel
system is easy to install and service. It
can be flush mounted beside your home
at ground level or placed on the roof for
horizontal or downflow installation. When
connected to a *CONT402, 802, or 803
comfort control, and air distribution ducts,
you have a highly efficient, total home
comfort system.
Single Packaged Dual Fuel Systems
are unmatched in quality and reliability. All major components on these
products, including the compressor,
have been designed and manufactured
for maximum service. Every Climatuff®
compressor is designed and manufactured to exacting specifications. Each
design is life tested in extreme environments to ensure reliable and long
lasting operation in normal applications.
Each compressor has internal motor
protection for added reliability.
2
Contents
Optional Equipment Listing 4
General Data 5
Indoor Blower Performance 8
Typical Wiring 16
Optional Equipment 14
Dimensional Data 19
Mechanical Specifications 25
3
Optional Equipment Listing
OPTIONAL EQUIPMENT FOR 4DCY4 PACKAGED UNITS (check mark [✓] indicates accessories included)
Hinged Filter Access Door (4DCY4024-036) 8 ................................................................ BAYACCDOR1A[ ]
Hinged Filter Access Door (4DCY4042-060) 8 ................................................................ BAYACCDOR2A[ ]
Roof Curb Full Perimeter (4DCY4024-036) 3 ...................................................................BAYCURB050A[ ]
Roof Curb Full Perimeter (4DCY4042-060) 3 ...................................................................BAYCURB051A[ ]
NOTES: 1 Must use internal filter frame when economizer or fresh air kit is used.
2 Dry bulb control standard with economizer.3 Ships knocked down.4 Downflow only.5 Low Ambient cooling requires crankcase heater (BAYCCHT----A).
6 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 7 BAYCOVR112,118A will not cover BAYSQRD002A applications.
8 BAYACCDOR1A requires BAYFLTR101B & BAYACCDOR2A requires BAYFLTR201B. They are not backward com-
‡ = A or B
patible to BAYFLTR101/201A.
4
General Data
MODEL
RATED Volts/PH/Hz
Performance Cooling BTUH
Indoor Airflow (CFM)
Power Input (KW)
EER/SEER(BTU/Watt-Hr.)
Sound Power Rating [dB(A)]7
HP Heating Performance
(High Temp.)BTUH / COP
Power Input (KW)
(Low Temp.) BTUH / COP
Power Input (KW)
HSPF (BTU / Watt-Hr.)
Gas Heating Performance
(High) Input BTUH
Capacity BTUH
Temp. Rise — Min/Max (°F)
(Low) Input BTUH
Capacity BTUH
AFUE
Type of Gas
Gas Pipe Size (in.)
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
INDOOR COIL — TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
Drain Conn. Size (in.)
OUTDOOR FAN — TYPE
Dia. (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g. 7
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
INDOOR FAN — TYPE
Dia x Width (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
COMBUSTION FAN — TYPE
Drive/No. Speeds
Motor — HP/R.P.M. (High/Low)
Volts/Ph/Hz
FLA
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft.)
REFRIGERANT / Charge (lbs.)
DIMENSIONS
Crated (in.)
WEIGHT / Shipping / Net (lbs.)
4DCY4024C1060A
208-230/1/60
23600
760
2.162
12/14.0
68
22400 / 3.7
1.77
11600 / 2.38
1.24
8.0
60000
48600
40 / 70
48000
38880
81
NATURAL/LP
1/2
208-230/1/60
16.1
25
25
RECIPROCATING
208-230/1/60
8.3 / 57.8
SPINE-FIN
2 / 24
13.32
3/8
EXPANSION VALVE
PLATE FIN
3 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
2590
1/12 / 810
208-230/1/60
0.54 / 0.95
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34
NO
THROWAWAY
4
R410A / 6.5
H X W X L
45.86 / 44.5 / 52.03
481 / 385
4DCY4030C1070A
208-230/1/60
30000
880
2.15
12.0 / 14.25
71
28000 / 3.9
2.15
15400 / 2.48
1.81
8.0
70000
56700
30 / 60
56000
45360
81
NATURAL/LP
1/2
208-230/1/60
19.1
30
30
RECIPROCATING
200-230/1/60
11.1 / 63
SPINE-FIN
2 / 24
13.32
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
3250
1/6 / 830
208-230/1/60
1.0 / 1.7
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
208-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34
NO
THROWAWAY
4
R410A / 6.56
H X W X L
45.86 / 44.5 / 52.03
481 / 385
4DCY4036C1070A
208-230/1/60
37000
1150
3.11
12.0 / 14.0
69
33200 / 3.6
2.7
22400 / 2.4
2.5
8.0
70000
56700
30 / 60
56000
45360
81
NATURAL/LP
1/2
208-230/1/60
26.2
40
40
SCROLL
208-230/1/60
16.7 / 79
SPINE-FIN
2 / 24
15.49
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
3310
1/5 / 830
208-230/1/60
1.1 / 1.9
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34
NO
THROWAWAY
4
R410A / 7.5
H X W X L
47.86 / 44.5 / 52.03
488 / 392
1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI
Standard 210/240.
2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a
rate of 4% per 1000 ft. elevation.
3 Convertible to LPG.
4 This value is approximate. For more precise value, see Unit Nameplate.
5 Based on U.S. Government Standard Tests.
6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent
filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C.
7 Sound Power values are not adjusted for AHRI 270-95 tonal corrections.
8 Standard Air — Dry Coil — Outdoor.
5
General Data
MODEL
RATED Volts/PH/Hz
Performance Cooling BTUH
Indoor Airflow (CFM)
Power Input (KW)
EER/SEER(BTU/Watt-Hr.)
Sound Power Rating [dB(A)]7
HP Heating Performance
(High Temp.)BTUH / COP
Power Input (KW)
(Low Temp.) BTUH / COP
Power Input (KW)
HSPF (BTU / Watt-Hr.)
Gas Heating Performance
(High) Input BTUH
Capacity BTUH
Temp. Rise — Min/Max (°F)
(Low) Input BTUH
Capacity BTUH
AFUE
Type of Gas
Gas Pipe Size (in.)
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
INDOOR COIL — TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
Drain Conn. Size (in.)
OUTDOOR FAN — TYPE
Dia. (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g. 7
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
INDOOR FAN — TYPE
Dia x Width (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
COMBUSTION FAN — TYPE
Drive/No. Speeds
Motor — HP/R.P.M. (High/Low)
Volts/Ph/Hz
FLA
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft.)
REFRIGERANT / Charge (lbs.)
DIMENSIONS
Crated (in.)
WEIGHT / Shipping / Net (lbs.)
4DCY4036B3075A
208-230/3/60
36000
1185
3.28
11.4 / 14.0
69
32400 / 3.5
2.7
20600 / 2.36
2.6
8.0
75000
60500
30 / 60
56250
48400
80.0
NATURAL
1/2
208-230/3/60
18.5
25
25
SCROLL
208-230/3/60
10.4 / 73
SPINE-FIN
2 / 24
15.49
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
3270
1/5 / 830
208-230/1/60
1.1 / 1.9
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
4
R410A / 7.4
H X W X L
47.86 / 44.5 / 52.03
488 / 392
4DCY4042C1090A
208-230/1/60
42000
1380
3.50
12.0 / 14.0
74
38000 / 3.45
3.23
23400 / 2.32
2.96
8.0
90000
72900
30 / 60
72000
58320
81
NATURAL/LP
1/2
208-230/1/60
30.8
45
45
SCROLL
208-230/1/60
17.9 / 112
SPINE-FIN
2 / 24
18.01
3/8
EXPANSION VALVE
PLATE FIN
3 / 15
5
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
4440
1/4 / 825
208-230/1/60
1.5 / 3.4
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
3/4 / VARIABLE
208-230/1/60
6.8 / 6.8
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34
NO
THROWAWAY
5.3
R410A / 8.2
H X W X L
47.86 / 47.4 / 61.75
653 / 525
4DCY4048C1090B
208-230/1/60
47500
1470
3.96
12.0 / 14.0
73
45000 / 3.5
3.77
26800 / 2.3
3.44
8.0
90000
72900
30 / 60
72000
58320
81
NATURAL/LP
1/2
208-230/1/60
33.9
50
50
SCROLL
208-230/1/60
20.5 / 109
SPINE-FIN
2 / 24
18.01
3/8
EXPANSION VALVE
PLATE FIN
3 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
4450
1/4 / 825
208-230/1/60
1.4 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
3/4 / VARIABLE
200-230/1/60
6.8 / 6.8
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34
NO
THROWAWAY
5.3
R410A / 7.75
H X W X L
47.86 / 47.4 / 61.75
653 / 525
1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI
Standard 210/240.
2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a
rate of 4% per 1000 ft. elevation.
3 Convertible to LPG.
4 This value is approximate. For more precise value, see Unit Nameplate.
5 Based on U.S. Government Standard Tests.
6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent
filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C.
7 Sound Power values are not adjusted for AHRI 270-95 tonal corrections.
8 Standard Air — Dry Coil — Outdoor.
6
General Data
MODEL
RATED Volts/PH/Hz
Performance Cooling BTUH
Indoor Airflow (CFM)
Power Input (KW)
EER/SEER(BTU/Watt-Hr.)
Sound Power Rating [dB(A)]7
HP Heating Performance
(High Temp.)BTUH / COP
Power Input (KW)
(Low Temp.) BTUH / COP
Power Input (KW)
HSPF (BTU / Watt-Hr.)
Gas Heating Performance
(High) Input BTUH
Capacity BTUH
Temp. Rise — Min/Max (°F)
(Low) Input BTUH
Capacity BTUH
AFUE
Type of Gas
Gas Pipe Size (in.)
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
INDOOR COIL — TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
Drain Conn. Size (in.)
OUTDOOR FAN — TYPE
Dia. (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g. 7
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
INDOOR FAN — TYPE
Dia x Width (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
COMBUSTION FAN — TYPE
Drive/No. Speeds
Motor — HP/R.P.M. (High/Low)
Volts/Ph/Hz
FLA
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft.)
REFRIGERANT / Charge (lbs.)
DIMENSIONS
Crated (in.)
WEIGHT / Shipping / Net (lbs.)
4DCY4048A3096C
208-230/3/60
47000
1470
4.03
10.85 / 14.0
73
42500 / 3.5
3.56
26800 / 2.3
3.44
8.0
96000
77500
30 / 60
72000
62000
80
NATURAL
1/2
208-230/3/60
25.3
35
35
SCROLL
208-230/3/60
13.7 / 83.1
SPINE-FIN
2 / 24
18.01
3/8
EXPANSION VALVE
PLATE FIN
3 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
4450
1/4 / 825
208-230/1/60
1.4 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
3/4 / VARIABLE
200-230/1/60
6.8 / 6.8
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
5.3
R410A / 7.75
H X W X L
47.86 / 47.4 / 61.75
653 / 525
4DCY4060C1115A
208-230/1/60
58000
1785
4.83
12.0 / 14.0
76
55000 / 3.6
4.48
35400 / 2.4
4.30
8.0
115000
93150
30 / 60
92000
74520
81
NATURAL/LP
1/2
208-230/1/60
39.9
60
60
SCROLL
208-230/1/60
25 / 134
SPINE-FIN
2 / 24
23.07
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
5710
1/3 / 830
208-230/1/60
1.7 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1 / VARIABLE
208-230/1/60
6.9 / 6.9
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34
NO
THROWAWAY
6.7
R410A / 11.94
H X W X L
51.86 / 47.4 / 61.75
676 / 548
4DCY4060A3120C
208-230/3/60
57500
1745
5.48
11.5 / 14.0
76
54500 / 3.5
4.56
36400 / 2.48
4.29
8.0
120000
96000
30 / 60
90000
77500
80.0
NATURAL
1/2
208-230/3/60
28.6
45
45
SCROLL
208-230/3/60
16.0 / 110
SPINE-FIN
2 / 24
23.57
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
1/3 / 830
208-230/1/60
1.7 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1 / VARIABLE
208-230/1/60
6.9 / 6.9
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
6.7
R410A / 10.125
H X W X L
51.86 / 47.4 / 61.75
676 / 548
1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI
Standard 210/240.
2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a
rate of 4% per 1000 ft. elevation.
3 Convertible to LPG.
4 This value is approximate. For more precise value, see Unit Nameplate.
5 Based on U.S. Government Standard Tests.
6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent
filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C.
7 Sound Power values are not adjusted for AHRI 270-95 tonal corrections.
Auxiliary Heating Airflow, horizontal or downflow from .2 to .6” wg.
10
Typical Field Wiring
11
Typical Wiring
12
Typical Wiring
13
Optional Equipment
46 3/8
17 7/8
3
3 5/8
19 1/2
2 3/16
19 1/2
14
1 1/2
38 7/8
15
35 7/8
43 3/8
BAYCURB050A Full Perimeter Roof Mounting Curb for *****024-036
The drawings on this page are prepared by the
manufacturer in order to provide detail regarding
job layout only. These drawings are not intended to
be used as a basis to construct, build or modify the
items depicted in the drawings. The manufacturer
is not responsible for the unauthorized use of these
drawings and expressly disclaims any liability for
damages resulting from such unauthorized use.
14
56 1/8
15 7/8
3
10 7/8
19 1/2
4 3/4
19 1/2
14
41 7/8
20
1 1/2
38 7/8
53 1/8
Optional Equipment
BAYCURB051A Full Perimeter Roof Mounting Curb for *****042-060
The drawings on this page are prepared by the
manufacturer in order to provide detail regarding
job layout only. These drawings are not intended to
be used as a basis to construct, build or modify the
items depicted in the drawings. The manufacturer
is not responsible for the unauthorized use of these
drawings and expressly disclaims any liability for
damages resulting from such unauthorized use.
15
Optional Equipment
BAYFLTR101, 201B, 1" - 2" Filter Rack
(Mounts in Filter/Coil Section)
Filter
BAYACCDOR1A & BAYACCDOR2A Hinged Filter Access Door
Replaces Filter/Coil Access Panel
The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are
not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized
use.
16
A
B
C
D
E
Optional Equipment
BAYECON101,102A Down Discharge Economizer and Rain Hood
(Mounts Over Horizontal Return Air Opening)
HVAC Unit
A
Economizer
rain hood
EconomizerUnit Application ModelsA
Mist eliminator
Relief
damper
Roofcurb
Outside air
dampers
Return
air dampers
Required
lter kit, order
separately
Return
Duct
BAYECON101A
BAYECON102A
4TC*,WC*,YC*,DC*
*018-036
4TC*,WC*,YC*, DC*
*042-060
20.125"
24.375"
The drawings on this page
are prepared by the manufacturer in order to provide
detail regarding job layout
only. These drawings are
not intended to be used as
a basis to construct, build or
modify the items depicted in
the drawings. The manufacturer is not responsible
for the unauthorized use of
these drawings and expressly disclaims any liability
for damages resulting from
such unauthorized use.
BAYECON200,201A Horizontal Economizer and Rain Hood
Economizer
Gaskets (2)
Duct
Mixed Air Sensor
Rain Hood
EconomizerABCDEF
BAYECON200AA22"20"16 7/8"15 11/1611 11/1615
BAYECON201AA26"22 21/32"19"17 11/1614 11/1621-3/8
17
A
B
C
D
FULLY
OPEN
2/3
1/3
FULLY
CLOSED
BAYOSAH001, 002A, 25% Outside Air Damper
D
C
B
A
E
The drawings on this page are prepared
by the manufacturer in order to provide
detail regarding job layout only. These
drawings are not intended to be used
as a basis to construct, build or modify
the items depicted in the drawings. The
manufacturer is not responsible for the
unauthorized use of these drawings and
expressly disclaims any liability for damages resulting from such unauthorized
use.
Optional Equipment
(Replaces Filter/Coil Access Panel)
Manual Fresh Air
Model
BAYOSAH001
BAYOSAH002
Unit Application ModelsABCD
4YC,WC3018-036
4TC*3018-036
4W/T/Y/DCY4024-036
4W/Y/DCZ6036
4YC,WC3042-060
4TC*3042-060
4W/T/Y/DCY4042-060
4W/Y/DCZ6048-060
22 7/16"20 11/16"12 3/8"9 3/16"
25 3/16"20 11/16"12 3/8"9 3/16"
BAYDMPR101,102A, 25% Motorized Outside Air Damper
(Mounts Over Horizontal Return AIr Opening)
BAYDMPR101A
Unit Application ModelsABCDE
4YC,WC3018-036
4TC3018-036
4W/T/Y/DCY4024-036
4W/Y/DCZ6036
4YC,WC3042-060
BAYDMPR102A
4TC3042-060
4W/T/Y/DCY4042-060
4W/Y/DCZ6048-060
15 13/16"11 13/16"10 1/4"11 1/2"12 1/4"
18 3/16"15 1/8"10 1/4"11 1/2"12 1/4"
18
Dimensional Data
4DCY4024 through 4DCY4036 (1 of 3)
19
Dimensional Data
4DCY4024 through 4DCY4036 (2 of 3)
20
Dimensional Data
4DCY4024 through 4DCY4036 (3 of 3)
21
Dimensional Data
4DCY4042 through 4DCY4060 (1 of 3)
22
Dimensional Data
4DCY4042 through 4DCY4060 (2 of 3)
23
Dimensional Data
4DCY4042 through 4DCY4060 (3 of 3)
24
Mechanical Specifications
General
All units shall be factory assembled,
piped, internally wired and fully charged
with refrigerant. All units shall be designed to operate at outdoor ambient
temperatures as high as 115°F. Cooling
capacities shall be rated in accordance
with A.H.R.I. standards. The 4DCY4 heating/cooling unit design is certified to UL
Standards 1995 and ANSI 221.47/CSA
2.3, specifically for outdoor applications
using natural gas or propane. All units
shall be designed for outdoor rooftop or
ground level installation. Unit casing is
constructed of heavy gauge, galvanized
steel and painted with a weather-resistant
powder paint.
Shipped for horizontal application,
convertible to downflow.
Casings
All panels shall be heavy gauge steel,
gasketed and insulated. Foil-faced
insulation shall be in the heat exchanger
section. Foil-faced insulation shall be in
the evaporator section. Base pan shall be
heavy gauge steel. WEATHERGUARD™
exterior corrosion resistant screws shall
be used for added resistance to rust and
corrosion.
Controls
Refrigeration cycle controls shall include
condenser fan, evaporator fan and compressor contactors. Compressors shall
be equipped with a combination internal
winding thermostat/current overload.
Internal high pressure relief shall also be
provided.
Refrigeration System
Compressors —
The Climatuff® compressor features internal over temperature and pressure protector, total dipped hermetic motor. Other
features include: centrifugal oil pump, and
low vibration and noise.
Evaporator Coil — Internally enhanced
3/8-inch OD seamless copper tubing
me chani cally bonded to aluminum fins,
factory pressure and leak tested at 250
to 300 psig. All units have TXV to control
refrigeration flow.
Condenser Coil —
The Spine Fin™ condenser coil shall be
continuously wrapped, corrosion resistant
all aluminum with minimum brazed joints.
This coil is 3/8 inch OD seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand
2,000 pounds of pressure per square
inch. The outdoor coil provides low airflow
resistance and efficient heat transfer.
The coil is protected on all four sides by
louvered panels.
Indoor Air Fan — Direct-drive, forwardcurved, centrifugal wheel in a Composite
Vortica® Blower housing. Motor shall
have thermal overload protection. Permanently lubricated motor bearings. Motor/
blower assembly isolated from unit with
rubber mounts.
Condenser Fan — Direct-drive, draw
through propeller type. Weather-proofed
permanent split capacitor fan motor shall
have built-in thermal overload and permanently lubricated motor bearings.
Low Ambient — Standard refrigerant
system operation down to 55°F. Low ambient accessory required for operation to
0°F ambient condition.
Gas-Fired Heating System — Models
shall provide completely assembled,
wired and piped gas fired heating systems
within unit. Threaded gas connection on
the unit.
Electronic Ignition System — Main
burner is lit each time thermostat calls for
gas heat. Flame sensor proves flame and
keeps the main burners on. Should a loss
of flame occur, the main valve closes and
the spark recurs within 0.8 second. When
thermostat is satisfied, main burner is
extinguished.
Forced Combustion Blower — Insures
flame stability under varying wind conditions. Gives higher combustion efficiency
and location flexibility.
be designed to mate with the unit
and provide support and complete
weather-tight installation when properly
installed. Curb shall ship knocked down
for field assembly, and include wood
nailer strips.
Modulating Economizer — This
accessory shall be field installed and
be composed of the following items:
0-100% fresh air damper, damper
drive motor fixed dry bulb enthalpy
control, and low voltage polarized plug
for electrical connections. Solid state
enthalpy or differential enthalpy control
is optional. Economizer operations shall
be controlled by the preset position
of the enthalpy control. A barometic
relief damper shall be standard with
the economizer and provide a pressure
operated damper that shall be gravity
closing and prohibit entrance of outside
air on equipment “off” cycle.
Manual Fresh Air Hood
Manual outside air provides a fixed outside air quantity from 0 to 25 percent.
Includes hood and birdscreen.
Low Ambient Control
Control allows cycling of compressor
under low ambient cooling conditions.
Required for cooling operation to 0°F.
Propane Gas
Conversion Kit — For conversion from
natural gas to LP gas.
6200 Troup Highway
Tyler, TX 75707-9010
10/14
The manufacturer has a policy of continuous product and product data improvement and it reserves the right
to change design and specifications without notice.
25
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.