Trane offers a complete family of dual fuel heating and cooling systems, designed to keep you comfortable all year long, regardless of the weather, while
keeping your operating costs as low as possible. The heat pump operates efficiently as both an air conditioner and a heater. In the summer, the heat pump
cools your home just like any other air conditioner by pulling the heat from the
inside and releasing it outdoors. In the winter, it captures the heat that is always present in the outdoor air and transfers it indoors. The gas furnace provides additional heating capacity for cooler weather.
Introducing the new TRANE Packaged Convertible Dual Fuel
System.
Single Packaged Convertible Dual
Fuel Systems are easy and versatile
to install. Because cooling and heating
functions are all contained in a single
cabinet, a Trane packaged dual fuel
system is easy to install and service. It
can be flush mounted beside your home
at ground level or placed on the roof for
horizontal or downflow installation. When
connected to a *CONT402, 802, or 803
comfort control, and air distribution ducts,
you have a highly efficient, total home
comfort system.
Single Packaged Dual Fuel Systems
are unmatched in quality and reliability. All major components on these
products, including the compressor,
have been designed and manufactured
for maximum service. Every Climatuff®
compressor is designed and manufactured to exacting specifications. Each
design is life tested in extreme environments to ensure reliable and long
lasting operation in normal applications.
Each compressor has internal motor
protection for added reliability.
2
Contents
Optional Equipment Listing 4
General Data 5
Indoor Blower Performance 8
Typical Wiring 16
Optional Equipment 14
Dimensional Data 19
Mechanical Specifications 25
3
Optional Equipment Listing
OPTIONAL EQUIPMENT FOR 4DCY4 PACKAGED UNITS (check mark [✓] indicates accessories included)
Hinged Filter Access Door (4DCY4024-036) 8 ................................................................ BAYACCDOR1A[ ]
Hinged Filter Access Door (4DCY4042-060) 8 ................................................................ BAYACCDOR2A[ ]
Roof Curb Full Perimeter (4DCY4024-036) 3 ...................................................................BAYCURB050A[ ]
Roof Curb Full Perimeter (4DCY4042-060) 3 ...................................................................BAYCURB051A[ ]
NOTES: 1 Must use internal filter frame when economizer or fresh air kit is used.
2 Dry bulb control standard with economizer.3 Ships knocked down.4 Downflow only.5 Low Ambient cooling requires crankcase heater (BAYCCHT----A).
6 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 7 BAYCOVR112,118A will not cover BAYSQRD002A applications.
8 BAYACCDOR1A requires BAYFLTR101B & BAYACCDOR2A requires BAYFLTR201B. They are not backward com-
‡ = A or B
patible to BAYFLTR101/201A.
4
General Data
MODEL
RATED Volts/PH/Hz
Performance Cooling BTUH
Indoor Airflow (CFM)
Power Input (KW)
EER/SEER(BTU/Watt-Hr.)
Sound Power Rating [dB(A)]7
HP Heating Performance
(High Temp.)BTUH / COP
Power Input (KW)
(Low Temp.) BTUH / COP
Power Input (KW)
HSPF (BTU / Watt-Hr.)
Gas Heating Performance
(High) Input BTUH
Capacity BTUH
Temp. Rise — Min/Max (°F)
(Low) Input BTUH
Capacity BTUH
AFUE
Type of Gas
Gas Pipe Size (in.)
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
INDOOR COIL — TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
Drain Conn. Size (in.)
OUTDOOR FAN — TYPE
Dia. (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g. 7
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
INDOOR FAN — TYPE
Dia x Width (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
COMBUSTION FAN — TYPE
Drive/No. Speeds
Motor — HP/R.P.M. (High/Low)
Volts/Ph/Hz
FLA
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft.)
REFRIGERANT / Charge (lbs.)
DIMENSIONS
Crated (in.)
WEIGHT / Shipping / Net (lbs.)
4DCY4024C1060A
208-230/1/60
23600
760
2.162
12/14.0
68
22400 / 3.7
1.77
11600 / 2.38
1.24
8.0
60000
48600
40 / 70
48000
38880
81
NATURAL/LP
1/2
208-230/1/60
16.1
25
25
RECIPROCATING
208-230/1/60
8.3 / 57.8
SPINE-FIN
2 / 24
13.32
3/8
EXPANSION VALVE
PLATE FIN
3 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
2590
1/12 / 810
208-230/1/60
0.54 / 0.95
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34
NO
THROWAWAY
4
R410A / 6.5
H X W X L
45.86 / 44.5 / 52.03
481 / 385
4DCY4030C1070A
208-230/1/60
30000
880
2.15
12.0 / 14.25
71
28000 / 3.9
2.15
15400 / 2.48
1.81
8.0
70000
56700
30 / 60
56000
45360
81
NATURAL/LP
1/2
208-230/1/60
19.1
30
30
RECIPROCATING
200-230/1/60
11.1 / 63
SPINE-FIN
2 / 24
13.32
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
3250
1/6 / 830
208-230/1/60
1.0 / 1.7
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
208-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34
NO
THROWAWAY
4
R410A / 6.56
H X W X L
45.86 / 44.5 / 52.03
481 / 385
4DCY4036C1070A
208-230/1/60
37000
1150
3.11
12.0 / 14.0
69
33200 / 3.6
2.7
22400 / 2.4
2.5
8.0
70000
56700
30 / 60
56000
45360
81
NATURAL/LP
1/2
208-230/1/60
26.2
40
40
SCROLL
208-230/1/60
16.7 / 79
SPINE-FIN
2 / 24
15.49
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
3310
1/5 / 830
208-230/1/60
1.1 / 1.9
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34
NO
THROWAWAY
4
R410A / 7.5
H X W X L
47.86 / 44.5 / 52.03
488 / 392
1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI
Standard 210/240.
2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a
rate of 4% per 1000 ft. elevation.
3 Convertible to LPG.
4 This value is approximate. For more precise value, see Unit Nameplate.
5 Based on U.S. Government Standard Tests.
6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent
filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C.
7 Sound Power values are not adjusted for AHRI 270-95 tonal corrections.
8 Standard Air — Dry Coil — Outdoor.
5
General Data
MODEL
RATED Volts/PH/Hz
Performance Cooling BTUH
Indoor Airflow (CFM)
Power Input (KW)
EER/SEER(BTU/Watt-Hr.)
Sound Power Rating [dB(A)]7
HP Heating Performance
(High Temp.)BTUH / COP
Power Input (KW)
(Low Temp.) BTUH / COP
Power Input (KW)
HSPF (BTU / Watt-Hr.)
Gas Heating Performance
(High) Input BTUH
Capacity BTUH
Temp. Rise — Min/Max (°F)
(Low) Input BTUH
Capacity BTUH
AFUE
Type of Gas
Gas Pipe Size (in.)
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
INDOOR COIL — TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
Drain Conn. Size (in.)
OUTDOOR FAN — TYPE
Dia. (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g. 7
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
INDOOR FAN — TYPE
Dia x Width (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
COMBUSTION FAN — TYPE
Drive/No. Speeds
Motor — HP/R.P.M. (High/Low)
Volts/Ph/Hz
FLA
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft.)
REFRIGERANT / Charge (lbs.)
DIMENSIONS
Crated (in.)
WEIGHT / Shipping / Net (lbs.)
4DCY4036B3075A
208-230/3/60
36000
1185
3.28
11.4 / 14.0
69
32400 / 3.5
2.7
20600 / 2.36
2.6
8.0
75000
60500
30 / 60
56250
48400
80.0
NATURAL
1/2
208-230/3/60
18.5
25
25
SCROLL
208-230/3/60
10.4 / 73
SPINE-FIN
2 / 24
15.49
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
3270
1/5 / 830
208-230/1/60
1.1 / 1.9
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
4
R410A / 7.4
H X W X L
47.86 / 44.5 / 52.03
488 / 392
4DCY4042C1090A
208-230/1/60
42000
1380
3.50
12.0 / 14.0
74
38000 / 3.45
3.23
23400 / 2.32
2.96
8.0
90000
72900
30 / 60
72000
58320
81
NATURAL/LP
1/2
208-230/1/60
30.8
45
45
SCROLL
208-230/1/60
17.9 / 112
SPINE-FIN
2 / 24
18.01
3/8
EXPANSION VALVE
PLATE FIN
3 / 15
5
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
4440
1/4 / 825
208-230/1/60
1.5 / 3.4
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
3/4 / VARIABLE
208-230/1/60
6.8 / 6.8
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34
NO
THROWAWAY
5.3
R410A / 8.2
H X W X L
47.86 / 47.4 / 61.75
653 / 525
4DCY4048C1090B
208-230/1/60
47500
1470
3.96
12.0 / 14.0
73
45000 / 3.5
3.77
26800 / 2.3
3.44
8.0
90000
72900
30 / 60
72000
58320
81
NATURAL/LP
1/2
208-230/1/60
33.9
50
50
SCROLL
208-230/1/60
20.5 / 109
SPINE-FIN
2 / 24
18.01
3/8
EXPANSION VALVE
PLATE FIN
3 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
4450
1/4 / 825
208-230/1/60
1.4 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
3/4 / VARIABLE
200-230/1/60
6.8 / 6.8
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34
NO
THROWAWAY
5.3
R410A / 7.75
H X W X L
47.86 / 47.4 / 61.75
653 / 525
1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI
Standard 210/240.
2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a
rate of 4% per 1000 ft. elevation.
3 Convertible to LPG.
4 This value is approximate. For more precise value, see Unit Nameplate.
5 Based on U.S. Government Standard Tests.
6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent
filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C.
7 Sound Power values are not adjusted for AHRI 270-95 tonal corrections.
8 Standard Air — Dry Coil — Outdoor.
6
General Data
MODEL
RATED Volts/PH/Hz
Performance Cooling BTUH
Indoor Airflow (CFM)
Power Input (KW)
EER/SEER(BTU/Watt-Hr.)
Sound Power Rating [dB(A)]7
HP Heating Performance
(High Temp.)BTUH / COP
Power Input (KW)
(Low Temp.) BTUH / COP
Power Input (KW)
HSPF (BTU / Watt-Hr.)
Gas Heating Performance
(High) Input BTUH
Capacity BTUH
Temp. Rise — Min/Max (°F)
(Low) Input BTUH
Capacity BTUH
AFUE
Type of Gas
Gas Pipe Size (in.)
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
INDOOR COIL — TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
Drain Conn. Size (in.)
OUTDOOR FAN — TYPE
Dia. (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g. 7
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
INDOOR FAN — TYPE
Dia x Width (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
COMBUSTION FAN — TYPE
Drive/No. Speeds
Motor — HP/R.P.M. (High/Low)
Volts/Ph/Hz
FLA
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft.)
REFRIGERANT / Charge (lbs.)
DIMENSIONS
Crated (in.)
WEIGHT / Shipping / Net (lbs.)
4DCY4048A3096C
208-230/3/60
47000
1470
4.03
10.85 / 14.0
73
42500 / 3.5
3.56
26800 / 2.3
3.44
8.0
96000
77500
30 / 60
72000
62000
80
NATURAL
1/2
208-230/3/60
25.3
35
35
SCROLL
208-230/3/60
13.7 / 83.1
SPINE-FIN
2 / 24
18.01
3/8
EXPANSION VALVE
PLATE FIN
3 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
4450
1/4 / 825
208-230/1/60
1.4 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
3/4 / VARIABLE
200-230/1/60
6.8 / 6.8
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
5.3
R410A / 7.75
H X W X L
47.86 / 47.4 / 61.75
653 / 525
4DCY4060C1115A
208-230/1/60
58000
1785
4.83
12.0 / 14.0
76
55000 / 3.6
4.48
35400 / 2.4
4.30
8.0
115000
93150
30 / 60
92000
74520
81
NATURAL/LP
1/2
208-230/1/60
39.9
60
60
SCROLL
208-230/1/60
25 / 134
SPINE-FIN
2 / 24
23.07
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
5710
1/3 / 830
208-230/1/60
1.7 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1 / VARIABLE
208-230/1/60
6.9 / 6.9
CENTRIFUGAL
DIRECT / 2
1/20 / 3350/2600
208-230/1/60
0.34
NO
THROWAWAY
6.7
R410A / 11.94
H X W X L
51.86 / 47.4 / 61.75
676 / 548
4DCY4060A3120C
208-230/3/60
57500
1745
5.48
11.5 / 14.0
76
54500 / 3.5
4.56
36400 / 2.48
4.29
8.0
120000
96000
30 / 60
90000
77500
80.0
NATURAL
1/2
208-230/3/60
28.6
45
45
SCROLL
208-230/3/60
16.0 / 110
SPINE-FIN
2 / 24
23.57
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
1/3 / 830
208-230/1/60
1.7 / 3.5
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1 / VARIABLE
208-230/1/60
6.9 / 6.9
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
6.7
R410A / 10.125
H X W X L
51.86 / 47.4 / 61.75
676 / 548
1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI
Standard 210/240.
2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a
rate of 4% per 1000 ft. elevation.
3 Convertible to LPG.
4 This value is approximate. For more precise value, see Unit Nameplate.
5 Based on U.S. Government Standard Tests.
6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent
filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C.
7 Sound Power values are not adjusted for AHRI 270-95 tonal corrections.