Central heating furnace designs are
certified by the International Approval
Services (IAS) for both natural and
L.P. gas. Limit setting and rating data
were established and approved under
standard rating conditions using
American National Standards Institute
standards.
SAFE OPERATION
The Integrated System Control has solid
state devices, which continuously
monitor for presence of flame, when the
system is in the heating mode of
operation. Dual solenoid combination
gas valve and regulator provide extra
safety.
QUICK HEATING
Durable, cycle tested, heavy gauge
aluminized steel heat exchanger
quickly transfers heat to provide warm
conditioned air to the structure. Lowenergy power vent blower, to increase
efficiency and provide a positive
discharge of gas fumes to the outside.
BURNERS
Multi-port In-shot burners will give years
of quiet and efficient service. All models
can be converted to L.P. gas without
changing burners.
INTEGRATED SYSTEM CONTROL
Exclusively designed operational
program provides total control of furnace
limit sensors, blowers, gas valve, flame
control and includes self diagnostics for
ease of service. Also contains
connection points for E.A.C./humidifier.
CONDENSATE DRAIN
Built-in trap which can drain from either
side when the furnace is installed upflow.
AIR DELIVERY
The variable speed, direct drive blower
motor, has sufficient airflow for most
heating and cooling requirements, will
switch from heating to cooling speeds on
demand from room thermostat. The
blower door safety switch will prevent or
terminate furnace operation when the
blower door is removed.
SECONDARY HEAT EXCHANGER
The XV 90 has a special type 29-4C™
stainless steel secondary heat
exchanger to reclaim heat from flue
gases which would normally be lost
outside.
STYLING
Heavy gauge steel and “wrap-around”
cabinet construction is used in the
cabinet with baked-on enamel finish for
strength and beauty. The heat exchanger
section of the cabinet is completely lined
with foil faced fiberglass insulation. This
results in quiet and efficient operation
due to the excellent acoustical and
insulating qualities of fiberglass. Built-in
bottom pan and alternate bottom, left or
right side return air connection in vertical
position.
FEATURES AND
GENERAL OPERATION
The XV 90 High Efficiency Gas Furnaces
employ a Hot Surface Ignition system,
which eliminates the waste of a constant
burning pilot. The integrated system
control lights the main burners upon a
demand for heat from the room
thermostat. Complete front service
access.
a. Low energy power venter.
b. Vent proving differential switch.
Electronic Air Filter, “Perfect Fit” Super Efficiency (14-1/2" Wide Gas Furnace) ......................................................... TFE145A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (17-1/2" Wide Gas Furnace) ......................................................... TFE175A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (21" Wide Gas Furnace) ............................................................... TFE210A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (24-1/2" Wide Gas Furnace) ......................................................... TFE245A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) .......................................................... TFM145A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .......................................................... TFM175A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ................................................................ TFM210A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .......................................................... TFM245A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ..................................................... TFP145A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ..................................................... TFP175A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) .......................................................... TFP210A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ..................................................... TFP245A9FR0 [ ]
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DUCT CONN.
DIMENSIONS
Crated (In.)
Uncrated
WEIGHT
Shipping (Lbs.)/Net (Lbs.)
1 Central Furnace heating designs are certified by AGA and CSA.
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above
input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
3
3
4
TUY060R9V3V
39000
37000
60000
56000
93.0
35 - 65
DIRECT
10 x 8
1
VARIABLE
SEE FAN PERF. TABLE
1/2
VARIABLE
115/1/60
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
115/1/60
1.1
YES
HIGH VELOCITY
1 X 17 X 25 X 1
2 ROUND
ALUMINIZED STEEL TYPE 1
20
3 - 45
3 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT
3
115/1/60
8.4
15
0.50
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 19-1/2 X 30-1/2
SEE OUTLINE DRAWING
158/146
TUY080R9V3V
52000
49000
80000
73000
92.5
35 - 65
DIRECT
10 x 8
1
VARIABLE
SEE FAN PERF. TABLE
1/2
VARIABLE
115/1/60
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
115/1/60
1.1
YES
HIGH VELOCITY
1 X 17 X 25 X 1
2 ROUND
ALUMINIZED STEEL TYPE 1
20
4 - 45
4 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT
4
115/1/60
8.4
15
0.50
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 19-1/2 X 30-1/2
SEE OUTLINE DRAWING
158/148
TUY100R9V4V
65000
62000
100000
93000
93.0
35 - 65
DIRECT
10 x 10
1
VARIABLE
SEE FAN PERF. TABLE
1
VARIABLE
115/1/60
CENTRIFUGAL
DIRECT - VARIABLE
1/15 - 5000
115/1/60
1.1
YES
HIGH VELOCITY
1 - 20 X 25 X 1
3 ROUND
ALUMINIZED STEEL TYPE 1
20
5 - 45
5 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT
5
115/1/60
11.4
15
0.50
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 23 X 30-1/2
SEE OUTLINE DRAWING
171/160
TUY120R9V5V
78000
74000
120000
112000
92.5
40 - 70
DIRECT
10 x 10
1
VARIABLE
SEE FAN PERF. TABLE
1
VARIABLE
115/1/60
CENTRIFUGAL
DIRECT - VARIABLE
1/25 - 5000
115/1/60
1.1
YES
HIGH VELOCITY
1 - 24 X 25 X 1
3 ROUND
ALUMINIZED STEEL TYPE 1
20
6 - 45
6 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITER
IN-SHOT
6
115/1/60
11.4
15
0.50
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 26-1/2 X 30-1/2
SEE OUTLINE DRAWING
205/193
6Pub. No. 22-1682-05-0802 (EN)
Performance
Data
*UY060R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
1.5
2.0
2.5
3
NOTES: * First letter may be "A" or "T"
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
AIRFLOW
SETTING
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
DIP SWITCH SETTINGEXTERNAL STATIC PRESSURE
SW 1SW 2SW 3SW 40.10.30.50.70.9
ONONOFFON
ONONOFFOFF
ONONONOFF
OFFONOFFON
OFFONOFFOFF
OFFONONOFF
ONOFFOFFON
ONOFFOFFOFF
ONOFFONOFF
OFFOFFOFFON
OFFOFFOFFOFF
OFFOFFONOFF
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
5756557590575
64070640
110
70085700
125
700
700
100
130
800
800
115
155
900
900
140
195
875
875
130
175
235
195
275
360
180
1000
235
1125
295
1050
260
1200
330
1325
425
1000
1125
1050
1200
1325
125
640
140
700
160
700
170
800
200
900
240
875
230
1000
285
1125
345
1050
305
1200
385
1300
460
550
155
630
175
700
200
700
210
800
250
900
290
875
270
1000
335
1100
370
1050
350
1100
385
1175
425
-
-
-
-
-
-
-
900
310
925
318
920
315
940
330
1000
365
*UY060R9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW
SETTING
LOWONON
HEATING
1ST
STAGE
HEATING
2ND
STAGE
NOTES:
* First letter may be "A" or "T"
** Factory setting
MEDIUM LOWOFFON
NORMAL **ONOFF
HIGHOFFOFF
LOWONON
MEDIUM LOWOFFON
NORMAL **ONOFF
HIGHOFFOFF
1st Stage Capacity =
2nd Stage Capacity =
DIP SWITCH SETTINGEXTERNAL STATIC PRESSURE
SW 7SW 80.10.30.50.70.9
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
600
57
85
700
49
90
775
44
105
870
39
135
860
61
140
1000
53
190
1125
47
250
1250
42
340
600
57
110
700
49
130
775
44
155
870
39
185
920
57
200
1000
53
255
1125
47
315
1250
42
405
37,000
56,000
600
57
155
700
49
175
775
44
195
870
39
235
920
57
245
1000
53
305
1125
47
370
1250
42
445
600
57
190
700
49
210
775
44
240
870
39
290
920
57
300
1000
53
340
1025
51
355
1100
48
390
7Pub. No. 22-1682-05-0802 (EN)
-
-
-
-
670
79
245
700
75
255
775
68
285
1000
53
355
Performance
Data
TUY080R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
2.0
2.5
3.0
3.5
NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position.
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cf m/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
AIRFLOW
SETTING
(See Notes)
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
DIP SWITCH SETTINGEXTERNAL STATIC PRESSURE
SW 1SW 2SW 3SW 40.10.30.50.70.9
ONONOFFON
ONONOFFOFF
ONONONOFF
OFFONOFFON
OFFONOFFOFF
OFFONONOFF
ONOFFOFFON
ONOFFOFFOFF
ONOFFONOFF
OFFOFFOFFON
OFFOFFOFFOFF
OFFOFFONOFF
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
75084750
840
109
940
136
850
113
960
150
1080
1020
1170
1290
1170
1360
1360
195
175
240
310
250
365
355
1110
1020
1180
1320
1190
1390
1390
122
840
146
940
177
850
150
990
200
255
225
300
410
315
445
450
1000
1120
1040
1200
1350
1210
1400
1400
750
154
840
181
940
215
870
200
230
315
280
365
470
370
500
520
720
185
840
226
940
274
890
250
1020
305
1120
365
1050
330
1200
415
1340
520
1210
435
1360
535
1350
535
710
221
820
264
940
318
890
295
1010
350
1080
390
1050
375
1130
420
1150
440
1100
405
1210
475
1180
460
TUY080R9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
HEATING
1ST
STAGE
HEATING
2ND
STAGE
NOTES:
** Factory setting
AIRFLOW
SETTING
LOWONON
MEDIUM LOWOFFON
NORMAL **ONOFF
HIGHOFFOFF
LOWONON
MEDIUM LOWOFFON
NORMAL **ONOFF
HIGHOFFOFF
DIP SWITCH SETTINGEXTERNAL STATIC PRESSURE
SW 7SW 80.10.30.50.70.9
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
1st Stage Capacity =
2nd Stage Capacity =
800
56
105
860
52
115
960
46
150
1080
41
195
1100
62
205
1210
57
265
1360
50
365
1360
50
355
800
56
140
880
51
165
990
45
200
1110
40
255
1100
62
260
1240
55
340
1390
49
445
1390
49
450
49,000
73,000
800
56
180
890
50
215
1000
44
230
1120
40
315
1120
61
320
1260
54
410
1400
49
500
1400
49
520
8Pub. No. 22-1682-05-0802 (EN)
800
56
220
920
48
265
1020
44
310
1120
40
365
1120
61
370
1260
54
470
1360
50
535
1350
51
535
800
56
265
910
49
320
1010
44
350
1080
41
390
1090
63
400
1130
61
430
1210
57
475
1180
58
465
Performance
Data
TUY100R9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
3.0
3.5
4.0
NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position.
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cf m/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
AIRFLOW
SETTING
(See Notes)
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
DIP SWITCH SETTINGEXTERNAL STATIC PRESSURE
SW 1SW 2SW 3SW 40.10.30.50.70.9
ONONOFFON
ONONOFFOFF
ONONONOFF
OFFONOFFON
OFFONOFFOFF
OFFONONOFF
ONOFFOFFON
ONOFFOFFOFF
ONOFFONOFF
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
1040
165
1210
235
1340
390
1200
225
1390
335
1590
490
1370
325
1640
515
1840
700
1040
220
1210
285
1370
390
1220
280
1430
425
1590
575
1420
415
1640
585
1840
780
1040
1230
1400
1230
1430
1590
1430
1640
1770
270
360
465
365
495
625
490
655
795
1030
320
1230
415
1390
525
1250
425
1430
560
1580
685
1340
550
1590
680
1630
725
1030
375
1230
475
1370
580
1230
485
1400
590
1420
615
1410
595
1420
615
1470
655
TUY100R9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
HEATING
1ST
STAGE
HEATING
2ND
STAGE
NOTES:
** Factory setting
AIRFLOW
SETTING
LOWONON
MEDIUM LOWOFFON
NORMAL **ONOFF
HIGHOFFOFF
LOWONON
MEDIUM LOWOFFON
NORMAL **ONOFF
HIGHOFFOFF
DIP SWITCH SETTINGEXTERNAL STATIC PRESSURE
SW 7SW 80.10.30.50.70.9
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
1st Stage Capacity =
2nd Stage Capacity =
920
60
130
1020
54
165
1160
48
220
1350
41
320
1290
67
275
1410
61
3561
1640
53
530
1970
44
855
920
60
180
1020
54
220
1160
48
260
1380
40
400
1290
67
355
1460
59
455
1640
53
590
1920
45
895
62,000
93,000
920
60
220
1020
54
260
1160
48
325
1400
40
470
1330
65
430
1460
59
520
1640
53
660
1780
48
820
920
60
280
1010
55
310
1160
48
390
1400
40
540
1340
64
490
1460
59
590
1600
54
695
1660
52
760
920
60
320
1000
56
365
1150
48
430
1390
40
585
1320
65
545
1370
63
590
1410
61
620
1520
57
695
9Pub. No. 22-1682-05-0802 (EN)
Performance
Data
TUY120R9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
3.5
4.0
5
NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position.
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cf m/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
AIRFLOW
SETTING
(See Notes)
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
DIP SWITCH SETTINGEXTERNAL STATIC PRESSURE
SW 1SW 2SW 3SW 40.10.30.50.70.9
OFFONOFFON
OFFONOFFOFF
OFFONONOFF
ONOFFOFFON
ONOFFOFFOFF
ONOFFONOFF
OFFOFFOFFON
OFFOFFOFFOFF
OFFOFFONOFF
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
1210
220
1400
305
1590
425
1390
305
1620
420
1840
600
1800
570
2050
845
2160
995
1210
270
1440
390
1600
520
1400
375
1650
530
1830
690
1780
630
2010
875
2040
935
1220
1450
1610
1430
1670
1820
1780
1860
1920
325
465
600
445
595
765
705
805
875
1230
400
1450
510
1600
645
1440
515
1640
660
1670
700
1700
695
1710
735
1780
805
1230
445
1410
560
1380
575
1420
565
1480
600
1490
620
1530
615
1530
655
1620
730
TUY120R9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
HEATING
1ST
STAGE
HEATING
2ND
STAGE
NOTES:
** Factory setting
AIRFLOW
SETTING
LOWONON
MEDIUM LOWOFFON
NORMAL **ONOFF
HIGHOFFOFF
LOWONON
MEDIUM LOWOFFON
NORMAL **ONOFF
HIGHOFFOFF
DIP SWITCH SETTINGEXTERNAL STATIC PRESSURE
SW 7SW 80.10.30.50.70.9
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
1st Stage Capacity =
2nd Stage Capacity =
1090
62
165
1210
56
220
1340
50
295
1430
47
390
1660
63
485
1870
56
675
2060
51
880
2200
48
1030
1120
60
225
1200
56
280
1360
50
350
1570
43
490
1690
62
590
1870
56
745
1990
53
890
2090
50
965
74,000
112,000
1080
1200
1370
1580
1680
1810
1850
1940
63
270
56
330
49
425
43
565
62
640
58
770
57
810
54
895
1070
63
310
1180
57
395
1380
49
495
1570
43
625
1640
64
675
1680
62
715
1710
61
750
1790
58
830
1010
67
380
1160
58
455
1330
51
535
1390
49
565
1460
72
600
1490
70
625
1530
68
665
1640
64
750
10Pub. No. 22-1682-05-0802 (EN)
Electrical
Data
SCHEMATIC DIAGRAMS FOR GAS FURNACES
LEGEND
TUY060,080,100,120R9V-V
From Dwg. 21D341111 P03
11Pub. No. 22-1682-05-0802 (EN)
TO 115 V 1 PH.,
60 HZ., POWER
SUPPLY PER
LOCAL CODES
HUM SEE
NOTE 5
EAC SEE
NOTE 5
Field
Wiring
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING
TO 115 V 1 PH.,
60 HZ., POWER
SUPPLY PER
LOCAL CODES
HUM SEE
NOTE 5
EAC SEE
NOTE 5
From Dwg. 21B341127 Rev. 0
FIELD WIRING DIAGRAM FOR 2 STAGE HEATING THERMOSTAT
From Dwg. 21B341126 Rev. 0
12Pub. No. 22-1682-05-0802 (EN)
Field
Wiring
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING
(OUTDOOR SECTION WITHOUT TRANSFORMER)
From Dwg. 21B341125 Rev. 1
FIELD WIRING DIAGRAM FOR 2 STAGE HEATING SINGLE STAGE COOLING
(OUTDOOR SECTION WITHOUT TRANSFORMER)
From Dwg. 21B341124 Rev. 1
13Pub. No. 22-1682-05-0802 (EN)
TO 115 V 1 PH.,
60 HZ., POWER
SUPPLY PER
LOCAL CODES
HUM SEE
NOTE 5
EAC SEE
NOTE 5
Field
Wiring
FIELD WIRING DIAGRAM FOR 2 STAGE HEATING TWO STAGE COOLING
(OUTDOOR SECTION WITHOUT TRANSFORMER)
From Dwg. 21B341128 Rev. 0
14Pub. No. 22-1682-05-0802 (EN)
Dimensions
(ALL DIMENSIONS ARE IN INCHES)
TUY-R9V-V OUTLINE DRAWING
15Pub. No. 22-1682-05-0802 (EN)
Trane
A business of American Standard Companies
www.trane.com
File No.PL-UN-FURN-TDD-D-1 3/98P. I .
SupersedesTDD-D-1 8/95
Since Trane has a policy of continuous product improvement, it reserves the right to change design and
specifications without notice.