TRAMEX CME4 Quick Start Manual

CME4
Concrete Moisture Encounter
www.tramexmeters.com
www.tramexmeters.com
QUICK START GUIDE
TROUBLESHOOTING
Single LED flashing and meter frozen.
CME4 is in HOLD mode.
Press HOLD button to release.
Both LED’s flashing when unit is powered up.
USER GUIDE ONLINE
Please use the following link or QR code to access the complete User Guide online: http://l.ead.me/bav1ez
LI-CME4GFSQSGUS
OPERATION
Press the ON/OFF button. Lower LED will remain continuously lit. Press CME4 fully aginst the surface of the concrete slab or screed. (Surface should be smooth and free of coatings/contaminants) Readings are instant and dispayed on analog dial.
To freeze readings press the HOLD button once. In HOLD mode the upper LED will flash continu­ously. If CME4 is shut down in HOLD it will retain the stored reading when powered up next and remain in HOLD with the upper light flashing until the button is pressed again. Automatic power timeout (10 mins) conserves battery life.
SCALES
Top Scale - Red - for use with Concrete Slabs & Sand/Cement screeds.
Middle Scale - Yellow - for use on Gypsum Floor/Screeds.
Equivalent reading to Moisture Content (MC%) or moisture by mass/weight as per the oven dry/gravimetric method.
Reference readings replicating measure­ments using concrete scale on concrete & sand/cement floors/screeds.
Bottom Scale - 0-100 - intended for use with materials other than concrete & screeds, such as stone & tiles etc.
This scale is for reference only and is not to be interpreted as moisture content or relative humidity.
Product Code: CALCRH
CALIBRATION & WARRANTY
Obtain Warranty online: tramexmeters.com/register Annual calibrations are recommended as best practice to ensure continued accuracy and reliability. Calibration Check Plates can be purchased for more regular checks. The Tramex Calibration Check Plate can be used to test the CME4 & CMEX2 instruments.