Trafimet PW 180 User Manual

Torch (1)
PACKAGING
MAX
MIN
Flowmeter
Flussometro Durchflussmessrohr
Indicateue d'écoulement
®
Torch head (1)
Electrode (10)
Warning For proper use and maintenance refer to the user's handbook attached to the torch.
Attenzione Consultare il manuale di uso e manutenzione allegato alla torcia.
Achtung Bitte unbedingt das beigefügte Bedienungshandbuch beachten.
Attention Consultez le manuel d'utilisation et de manutention joint à la torche.
Tip (10)
Diffuser (2)
Check the state of the swirl ring. Air holes must be open. If not, the low cooling system will damage the torch head.
Controllare lo stato di efficienza del diffusore aria, che deve sempre presentare i fori di accesso aria liberi da occlusioni.
Uberprüfen des Luftverteilers, das die Löcher nicht verstopft sind.
Contrôler le rendement du diffuseur d'air dont les trous d'accès d'air doivent rester libres de toutes occlusions.
CV 91
Nozzle
(2 or 4)
PD 115-16
PW 180
Operating instructions
The excessive wear of tip and electrode may cause some damage to the torch head. Replace the electrode before its total consumption as well as the tip when showing an irregular hole or an increased diameter.
Modalità d'uso
L'eccessiva usura di cappa ed elettrodo può creare danni al corpo torcia, sostituire l'elettrodo prima del totale consumo dell'inserto e la cappa quando presenta un foro irregolare o di diametro maggiorato.
Gebrauchsanweisung
Elektrode und Schneiddüsen sollten auf den Verschleiß hin überprüft werden, überhöhte Beanspruchung führt zu verschlechterten Schneidergebnissen und kann zu einer Beschädigung des Brennerkörpers führen.
Modalite d'usage
L'usure excessive de la tuyère et de l'electrode peuvent causer des dommages au col de cygne, remplacer l'electrode avant l'usure totale de l'insert en HF ainsi que la tuyère si celle-ci présente une "usure irrégulière" ou un diamètre majoré.
CV 80
Warranty will be valid only for genuine TRAFIMET spare parts
La garanzia viene riconosciuta soltanto per ricambi originali TRAFIMET
Garantie wird nur für Original TRAFIMET Teile übernommen
Utiliser seulement pièces d'usure originales TRAFIMET
®
Choose the hole of the tip according to the following table:
Il diametro del foro della cappa va scelto secondo la seguente tabella:
Schneiddüsen Durchmesser laut der nachstenden Tabelle:
Choisir le diamètre de la tuyère selon le tableau suivant:
ØA
1.2 50 - 80
1.4 70 - 100
1.6 90 - 140
1.8 110 - 160
2.0 130 - 180
PW 180
MANUAL
PW 180 P
AUTOMATIC
®
®
Copyright © July 1997 • by TRAFIMET spa (Print 05/98) EA 0446
EN 50078 EN 50192
Ø 35
Technical data
Voltage class M
Patented by Trafimet Patented by Trafimet
6 m
295
385
Standard lenght 6 m Air consumption 38 l/min Air pressure 4 bar Duty cycle 100% 180 A Cooling Water cooled 1.4 l/min
PW 180 • PW 180 P
1 m
1.2 Kg
PW 180PW 180 P
6 m
PH 244 Steel cable assembly
PH 219 Steel cable assembly cover
PH 155
Rubber cable assembly
FE 1132
PG 2
EA 203 OR
PR 118
FH 709
TP 61
EA 197 (x4)
90
BX 08
TP 60
EA 23
EA 282
FH 709
• Standard
EA 282
FH 158
PG 1
PR 118
PE 114
EA 203 OR
EA 200 OR
EA 202 OR EA 201 OR
PC 125
PD 115-12 PD 115-14 PD 115-16 PD 115-18 PD 115-20 PD 115-30
BW 197
EA 280
MQ 112
Cable assembly cover (per meter)
PH 155
Cable assembly
MQ 3
FA 3020
PT 24
MQ 3
FB 292
BW 162
BW 213
FA 3020
PW 180 P complete torch m Adaptor
PB 5 6 Central
PB 20 6 Central
EA 282
FH 136
PE 114
EA 18
BW 214
BW 174
FY 18
PD 115-12 PD 115-14 PD 115-16 PD 115-18 PD 115-20
CV 77 Ceramic
PC 125
• Standard
CV 22
CV 11
CV 13 Gouging
CV 77 Ceramic
CV 12
CV 14
FY 18
CV 21
BW 214
EA 282
EA 18
BW 174
FA 3020
FE 1132
MQ 3
BW 213
BX 125
(per meter)
EA 280
BX 140
FH 136
(per meter)
BW 162
PT 24
FB 292
PW 180 complete torch m Adaptor
PB 2 6 Central
Loading...