Trafimet CB 100 Automatic, CB 100 Manual Quick Start Manual

Torch (1)
PACKAGING
MAX
MIN
Flowmeter
Flussometro Durchflussmessrohr
Indicateue d'écoulement
®
Torch head (1)
Electrode (10)
Warning
For proper use and maintenance refer to the user's handbook attached to the torch.
Attenzione
Consultare il manuale di uso e manutenzione allegato alla torcia.
Achtung
Bitte unbedingt das beigefügte Bedienungshandbuch beachten.
Attention
Consultez le manuel d'utilisation et de manutention joint à la torche.
Tip (10)
Diffuser (2)
Check the state of the swirl ring. Air holes must be open. If not, the low cooling system will damage the torch head.
Controllare lo stato di efficienza del diffusore aria, che deve sempre presentare i fori di accesso aria liberi da occlusioni.
Uberprüfen des Luftverteilers, das die Löcher nicht verstopft sind.
Contrôler le rendement du diffuseur d'air dont les trous d'accès d'air doivent rester libres de toutes occlusions.
CV 94
Nozzle
(2 or 4)
PD 26-11
CB 100
Operating instructions
The excessive wear of tip and electrode may cause some damage to the torch head. Replace the electrode before its total consumption as well as the tip when showing an irregular hole or an increased diameter.
Modalità d'uso
L'eccessiva usura di cappa ed elettrodo può creare danni al corpo torcia, sostituire l'elettrodo prima del totale consumo dell'inserto e la cappa quando presenta un foro irregolare o di diametro maggiorato.
Gebrauchsanweisung
Elektrode und Schneiddüsen sollten auf den Verschleiß hin überprüft werden, überhöhte Beanspruchung führt zu verschlechterten Schneidergebnissen und kann zu einer Beschädigung des Brennerkörpers führen.
Modalite d'usage
L'usure excessive de la tuyère et de l'electrode peuvent causer des dommages au col de cygne, remplacer l'electrode avant l'usure totale de l'insert en HF ainsi que la tuyère si celle-ci présente une "usure irrégulière" ou un diamètre majoré.
®
www.trafimet.com
CB 100 CB 100 P
MANUAL
AUTOMATIC
®
®
TRAFIMET spa claim that all items on this catalogue are manufactured in conformity with the "low voltage" CE 73/23 directive as per EN 60974-7 standard. The company reserve the right to modify any products without notice. TRAFIMET spa is the registered owner of all trademarks, patents and models.
Copyright © 1997 Trafimet Spa. All rights reserved. Print date 10/00
EA 0580
EN 60974-7
6 m
Ø 35
296
386
Technical data
Voltage class M Standard lenght 6 m Air consumption 180 l/min Air pressure 5 bar Duty cycle 100% 70 A Duty cycle 60% 100 A
CB 100 • CB 100 P
1 m
0.80 Kg
CB 100CB 100 P
6 m
TP 83
Submariner handle
BX 70
PH 247 (1/8 G) PH 246 (1/4 G)
Steel cable assembly
PH 217
Steel cable assembly cover
EA 229 OR
1/8 G
PF 37
EA 131 OR - 1398
FH 214 1378
PR 34 1376
FH 158
TP 61
90
EA 131
OR 1398
PR 45 1517
PE 09 1377
PD 25-14 PD 25-16 PD 25-18
(90 A max) (120 A max) (150 A max)
PD 30 1369
(50 A max)
PC 38
PF 38
EA 132 OR
FH 214 1378
PD 28-13 PD 28-16 PD 28-18
PC 37
EA 23
PR 34 1376
PE 09 1377
BX 207
BX 125
Pilot arc lead (per meter)
QB 164
PD 26-11 1371 PD 26-13 1372 PD 26-16 1373 PD 26-18 1374
1/8 G
BX 269
BX 138
Control leads (per meter)
Cable assembly cover (per meter)
PH 162 Air and power cable
• Standard
PH 171
Rubber cable assembly
RUBBER CABLE
STEEL CABLE
PE 09
1377
1/4 G
PC 37
CY 36
CY 35
CB 100 P complete torch m Adaptor
PA 1216 6 1/8 G PA 1219 6 Central PA 1225 6 1/8 G PA 1227 6 Central
PD 26-11 1371 PD 26-13 1372 PD 26-16 1373 PD 26-18 1374
FY 23 Central
• Standard
Estrattore per diffusore
Ausdreher für Wirbelring
Extracteur pour diffuseur
GR 60 1509
Swirl ring extractor
CV 9
CV 8
CV 38
CV 11 1386
CV 22 169
CV 12 1408
FY 23 Central
NEW
Submariner handle
BX 211
PH 174
Cable assembly
BX 185
1/4 G
CV 21 155
PH 171
Cable assembly
CY 36
CY 35
PH 107
Air and power cable
CB 100 complete torch m Adaptor
PA 1230 6 1/8 G PA 1232 6 Central
Loading...