INSTALLATION INFORMATION
TMPS 03Series AC/DC POWER MODULE
Order Code Output Power max. Output
TMPS 03-103 3 Watts 3.3Vdc / 900mA
TMPS 03-105 3 Watts 5Vdc / 600mA
TMPS 03-109 3 Watts 9Vdc / 333mA
TMPS 03-112 3 Watts 12Vdc / 250mA
TMPS 03-115 3 Watts 15Vdc / 200mA
TMPS 03-124 3 Watts 24Vdc / 125mA
Input Voltage Range: 85-264VAC / 60-50Hz
Input Current:
Operation T emp eratur e Range: -25℃~+70℃ max.
Output Power Derating: +60℃ to +70℃ Î 0.15W/℃
Internal Fuse: T1A 250VAC Min
65mA typ. at Vin = 115VAC
40mA typ. at Vin = 230VAC
Safety Instructions:
¾ Before installation read these instructions carefully and
completely. This installation instruction cannot claim for every
possible example of installation, operation or maintenance.
Further information’s are obtainable from your local distributor
office or from the product data s heet w hic h can be dow nload ed
from the Internet at http://www.tracopower.com/
¾ The power supplies are constructed in accordance with the
safety requirements of cUL/UL/IEC/EN60950-1 and
IEC/EN60335-1. They fulfil the requirements of the Low
Voltage Directive (LVD) and carries the CE-mark. UL and cUL
are approved in accordance to UL60950-1, and TUV is
approved in accordance to IEC/EN60335-1.
¾ Before an installation, maintenance or modification work
ensure that the main switch is switched off and prevented from
being switched on again. In case of non-observance touching
at any alive components or improper dealing with this power
supply can result in death, severe personal in jury or substantial
property damage. The successful and safe operation is
dependent of proper storage, handling, installation and
operation.
¾ Compliance with the relevant national regulations (in the USA,
Europe and the other countries) must be observed and
ensured. Before operation is started the following conditions
must be ensured:
Connection to mains supply in compliance with national
regulations (VDE0100 and EN50178).
By use of stranded wires, all strands must be fastened in the
terminal blocks.
Power supply and mains cables must be sufficiently fused.
All output wires must be rated for the power supply output
current and must be connected with the correct polarity.
Sufficient cooling must be ensured
Keep away from fire and water
¾ Never work on the power supply if power is supplied! Risk
of electric arcs and electrical shock which can cause death,
severe personal injury of substantial property damage.
Terminal for
Wiring:
Case Material:
¾ Warning: Hazardous voltages and components storing a very
¾ For the assembl y i nformation of c hosen AC/DC Power Module,
◆ Avertissement:Ce bloc d’alimentation contient une grande
◆ Pour assembler ce module d’alimentation CA/CC, veuillez
PCB mounting with solder pin’s.
Plastic Resin + Fiberglas
UL 94V-0 flammability rating
substantial amount of energy are present in this power supply
during normal operating conditions. However, these are
inaccessible. Improper handling may result i n an el ectr ic shock
or serious burns!
see the AC/DC Power Module specification and rating label for
details:
Make sure the dimensions of location for assembly
complying with category or specification datasheet.
Do not expose the AC/DC Power Module to excessive heat,
moisture, dust, or corrosive gases.
The overall dimensions of AC/DC Power Module shall be
assembled according to the ventilation designs of end-use
product.
Do not open the power supply until at least 5 minutes after
it has been disconnected from the mains on all poles.
tension et des composants puissants pendant l’utilisation
normale. Une mauvaise manipulation peut causer un choc
électrique ou des brûlures graves !
vous référer aux spécifications et la plaque signalétique du
module CA/CC :
◆La dimension de l’endroit de l’assemblage doit correspondre
à la catégorie ou aux spécifications.
◆Il ne faut pas exposer ce module d’alimentation CA/CC à la
chaleur, à l’humidité, à la poussière ou aux gaz corrosifs.
◆La dimension générale du module CA/CC doit respecter le
système de ventilation du produit fini.
Avant d’ouvrir le bloc d’alimentation, attendre au moins 5
minutes après la déconnexion de tous les pôles
Sihlbruggstrasse 111 CH-6340 Baar, Switzerland
Issued: Dec. 30
th
, 2014 / Rev.:1

Installation Instructions:
¾ This power supply is desig ned for professio nal i ndoor systems.
In operation the power supply must not be accessible. It may
be installed and put into service by qualified personnel only.
¾ The correct mounting position for optimal cooling performance
must be observed. Observe power derating. (see data sheet)
¾ Recycling: The unit contains elements which are suitable for
recycling, and components which need special disposal. You
are therefore requested to make sure that the power supply
will be recycled by the end of its service life.
Wiring Terminals Diagram:
3
Pin Connections
Pin
4
2
1
5
Function
AC(N)
1
2
AC(L)
3
4
5
NC
-
Vout
+Vout
Sihlbruggstrasse 111 CH-6340 Baar, Switzerland
Issued: Dec. 30