TRACO POWER TMPS 03 Series, TMPS 03-103, TMPS 03-105, TMPS 03-109, TMPS 03-112 Installation Information

...
INSTALLATION INFORMATION
TMPS 03Series AC/DC POWER MODULE
Input Voltage Range: 85-264VAC / 60-50Hz Input Current:
Operation T emp eratur e Range: -25℃~+70℃ max. Output Power Derating: +60℃ to +70Î 0.15W/℃ Internal Fuse: T1A 250VAC Min
65mA typ. at Vin = 115VAC 40mA typ. at Vin = 230VAC
Safety Instructions:
¾ Before installation read these instructions carefully and
completely. This installation instruction cannot claim for every possible example of installation, operation or maintenance. Further information’s are obtainable from your local distributor office or from the product data s heet w hic h can be dow nload ed from the Internet at http://www.tracopower.com/
¾ The power supplies are constructed in accordance with the
safety requirements of cUL/UL/IEC/EN60950-1 and IEC/EN60335-1. They fulfil the requirements of the Low Voltage Directive (LVD) and carries the CE-mark. UL and cUL are approved in accordance to UL60950-1, and TUV is approved in accordance to IEC/EN60335-1.
¾ Before an installation, maintenance or modification work
ensure that the main switch is switched off and prevented from being switched on again. In case of non-observance touching at any alive components or improper dealing with this power supply can result in death, severe personal in jury or substantial property damage. The successful and safe operation is dependent of proper storage, handling, installation and operation.
¾ Compliance with the relevant national regulations (in the USA,
Europe and the other countries) must be observed and ensured. Before operation is started the following conditions must be ensured:
Connection to mains supply in compliance with national
regulations (VDE0100 and EN50178).
By use of stranded wires, all strands must be fastened in the
terminal blocks.
Power supply and mains cables must be sufficiently fused. All output wires must be rated for the power supply output
current and must be connected with the correct polarity.
Sufficient cooling must be ensured Keep away from fire and water
¾ Never work on the power supply if power is supplied! Risk
of electric arcs and electrical shock which can cause death, severe personal injury of substantial property damage.
Terminal for
Wiring:
Case Material:
¾ Warning: Hazardous voltages and components storing a very
¾ For the assembl y i nformation of c hosen AC/DC Power Module,
Avertissement:Ce bloc d’alimentation contient une grande
Pour assembler ce module d’alimentation CA/CC, veuillez
PCB mounting with solder pin’s.
Plastic Resin + Fiberglas UL 94V-0 flammability rating
substantial amount of energy are present in this power supply during normal operating conditions. However, these are inaccessible. Improper handling may result i n an el ectr ic shock or serious burns!
see the AC/DC Power Module specification and rating label for details:
Make sure the dimensions of location for assembly
complying with category or specification datasheet.
Do not expose the AC/DC Power Module to excessive heat,
moisture, dust, or corrosive gases.
The overall dimensions of AC/DC Power Module shall be
assembled according to the ventilation designs of end-use product.
Do not open the power supply until at least 5 minutes after it has been disconnected from the mains on all poles.
tension et des composants puissants pendant l’utilisation normale. Une mauvaise manipulation peut causer un choc électrique ou des brûlures graves !
vous référer aux spécifications et la plaque signalétique du module CA/CC :
La dimension de l’endroit de l’assemblage doit correspondre à la catégorie ou aux spécifications.
Il ne faut pas exposer ce module d’alimentation CA/CC à la chaleur, à l’humidité, à la poussière ou aux gaz corrosifs.
La dimension générale du module CA/CC doit respecter le système de ventilation du produit fini.
Avant d’ouvrir le bloc d’alimentation, attendre au moins 5 minutes après la déconnexion de tous les pôles
Sihlbruggstrasse 111 CH-6340 Baar, Switzerland
Issued: Dec. 30
th
, 2014 / Rev.:1
Installation Instructions:
¾ This power supply is desig ned for professio nal i ndoor systems.
In operation the power supply must not be accessible. It may be installed and put into service by qualified personnel only.
¾ The correct mounting position for optimal cooling performance
must be observed. Observe power derating. (see data sheet)
¾ Recycling: The unit contains elements which are suitable for
recycling, and components which need special disposal. You are therefore requested to make sure that the power supply will be recycled by the end of its service life.
Wiring Terminals Diagram:
3
Pin Connections
Pin
4
2
1
5
Function
AC(N)
1 2
AC(L) 3 4 5
NC
-
Vout
+Vout
Sihlbruggstrasse 111 CH-6340 Baar, Switzerland
Issued: Dec. 30
th
, 2014 / Rev.:1
Loading...