TracoPower TMM 24109, TMM 24115, TMM 24105, TMM 24112, TMM 24212 Installation Instructions Manual

...
Sihlbruggstrasse 111 CH-6340 Baar, Switzerland
Issued: SEPT. 25th, 2013 / Rev.: 0.0
INSTALLATION INSTRUCTIONS
TMM 24 Series AC/DC Switching Power Supply
Order Code *
Input Voltage
Range
Rated Output
Power
Output1
Output2
Recommended
circuit Breaker /
Fuse
TMM 24105 (C)
Nominal:
100 – 240Vac
47 – 440Hz
Operational:
85-264Vac
47 – 440Hz
15W
5Vdc / 3000mA
-
?
TMM 24109 (C)
24W
9Vdc / 2666mA
-
TMM 24112 (C)
12Vdc / 2000mA
-
TMM 24115 (C)
15Vdc / 1600mA
-
TMM 24124 (C)
24Vdc / 1000mA
-
TMM 24212 (C)
+12Vdc / +1000mA
-12Vdc / -1000mA
TMM 24215 (C)
+15Vdc / +800mA
-15Vdc / -800mA
* Option C indicates the unit with chassis mount
Input Current:
@ Vin = 115Vac
@ Vin = 230Vac
TMM 24105 (C)
285mA
170mA
TMM 24xxx (C)
425mA
255mA
Operating temperature range: Natural Air Convection Cooling (20LFM)
-40°C – +80°C
Over temperature protection:
Shutdown:
Automatic recovery:
at 90°C at 67°C approx
Output power derating in respect to ambient temperature:
Model Type
Start of derating
Power derating
TMM 24105 (C)
+60°C
2.5%/K
TMM 24xxx (C)
+60°C
3.75%/K
Storage temperature range / Humidity:
-40°C – +95°C / 95% rH max.
Over voltage protection (main output only):
120% of V
out
typ.
Connections:
Input / Output terminal:
Screw type terminal: Wires 1.5mm2 max. Recommended tightening torque (Used Copper Conductors only, 60/75°C): 0.5 to 0.6Nm (4.4 to 5.3lb.in.)
Pin (TMM 24xxxC):
PCB mounting with solder pins
Internal Fuse:
T2A 250VAC Min.
Case Material:
Plastic Resin + Fiberglass UL 94V-0 flammability rating
Installation:
1. The following end product enclosures are required; Mechanical, Fire & Electrical in accordance to applicable safety standards.
Sihlbruggstrasse 111 CH-6340 Baar, Switzerland
Issued: SEPT. 25th, 2013 / Rev.: 0.0
Safety Instructions:
Before installation read these instructions carefully and
completely. This installation instruction cannot account for every possible condition of installation, operation or maintenance. Further information can be obtained from
your local distributor’s office or from the product datasheet,
which can be downloaded from our website: http://www.tracopower.com.
The power supplies are constructed in accordance with the
safety requirements of IEC/EN60950-1 and UL60950-1, UL 508 and CSA C22.2 No 107.1-01. They fulfil the requirements of the Low Voltage Directive (LVD) and carries the CE-mark. They are UL and cUL approved in accordance to ANSI/AAMI ES60601-1, UL60950-1, UL 508 and CSA C22.2 No107 1-01 (recognised).The equipment has not been evaluated according to IEC60601-1-2. The EMC assessment shall be conducted for the end system configuration.
Before any installation, maintenance or modification work
ensure that the main switch is switched off and prevented from being switched on again. Non-observance, touching of any live components or improper handling of this power supply can result in death, severe personal injury or substantial property damage. Proper and safe operation is dependent on proper storage, handling, installation and operation.
While applying connections, no mechanical stress should
be applied to the printed circuit board and its surface mounted components.
Compliance with the relevant national regulations must be
ensured. Before operation is started the following condi­tions must be ensured: Connection to mains supply in compliance with national
regulations.
Power supply and mains cables must be sufficiently
fused.
All output wires must be rated for the power supply
output current and must be connected with the correct polarity.
Do not disconnect while circuit is alive. Sufficient cooling must be ensured The equipment for installation in a Pollution Degree 2
environment.
The classification of the equipment is: (For ANSI/AAMI
ES60601-1)
Class II No applied parts Not AP or APG type Protection class IPX0 Not intended for use in the presence of flammability
anaesthetic mixture with air or with oxygen or nitrous oxide
Intended for continuous operation
Never work on the power supply if power is supplied:
Risk of electric arcs and electrical shock, which can cause death, severe personal injury or substantial property damage.
Warning: Hazardous voltages and components storing a
very substantial amount of energy are present in this power supply during normal operating conditions. Improper handling may result in an electric shock or serious burns!
Do not open the power supply
Do not introduce any objects into the power supply. An
output voltage adjustment potentiometer (if existing) may only be actuated using an insulated screwdriver.
Keep away from fire, water and chemicals.
The switching power supply is intended used for medical
electrical equipment. There are not parts in this equipment, not suitable for direct patient contact! (ANSI/AAMI ES60601-1)
Do not modify this equipment without authorization of the
manufacturer. (ANSI/AAMI ES60601-1)
Caution: Double Pole/Neutral Fusing Do not open the power supply until at least 5 minutes after
it has been disconnected from the mains on all poles.
Installation Instructions
This power supply is designed for professional indoor
systems. In operation the power supply must not be accessible. It may be installed and put into service by qualified personnel only.
All required connections have to be carried out as
described in the table on the front side.
By use of stranded wires, all strands must be fastened in
the terminal blocks (potential danger of short circuits).
Do not cover any ventilation holes. Optimal cooling
performance must be ensured. Observe power derating (see datasheet).
The internal fuse(s) may not be replaced by the user. If an
internal fuse has blown, the power supply has most properly an internal defect and, for safety reasons, must be shipped to the local distributor.
The correct mounting position for optimal cooling
performance must be observed. Observe power derating. (see datasheet)
Recycling: The unit contains elements that are suitable for
recycling, and components that need special disposal. You are therefore requested to make sure that the power supply will be recycled environment friendly at the end of its service life.
Loading...