www.tracopower.com Page 2
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input current (no load) TYL models < 95 mA
TVL models < 170 mA
Input current (full load) TYL models 500 mA typ.
TVL models 1’600 mA typ.
Otput Specifications
Voltage set accuracy ± 3 %
Regulation – Input variation Vin min. to Vin max. TYL models: ± 0.3 % max.
TVL models: ± 0.03 % max.
– Load variation 0 – 100 % TYL models: ± 0.3 % max.
TVL models: ± 0.18 % max.
Ripple and noise (20 MHz Bandwidth) TYL models: 6 mVpk-pk max.
TVL models: 3 mVpk-pk max.
Temperature coefficient ± 0.02 % / °C
Output current limitation >120 % of Iout max.
Short circuit protection indefinite (automatic rcovery)
General Specifications
Temperature ranges – Operating – 25°C ... +71°C
– Storage – 45°C ... +85°C
Derating 3%/°C above 50°C
Efficiency 60% (TVL 05-05W08: 45%)
Humidity (non condensing) 30 – 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217 F) >1’000’000h @ + 25 °C
Isolation voltage Input/Output 500 VDC
Isolation capacity Input/Output 100 pF
Isolation resistance Input/Output (500 VDC) > 10 M Ohm
Switching frequency TYL models: 70 – 400 kHz depending on load
TVL models: 50 – 300 kHz depending on load
Vibration 5 to 10 Hz amplitude 10 mm pk-pk
10 to 55 Hz acceleration 2 G
Shock acceleration 20 G max. time 11 ms
DC/DC Conver ter
TYL/TVL Series 1.5-5 Watt