TRACO TYL05-15W05, TYL05-15S10, TYL05-1520, TYL05-1516, TYL05-12W06 Datasheet

...
www.tracopower.com Page 1
Features
DC/DC Conver ter
TYL/TVL Series 1.5-5 Watt
Models
Ultra low Ripple and Noise Full SMD - Design with Ceramic
The TYL and TVL Series are DC/DC-Converter with very low output ripple and noise specification. These DC/DC-Converter are an ideal solution for noise sensitive applications as analoge circuits, audio applications, reference voltages or mesuring systems. SMD­technology and a 100 % production test ensure a very high reliability of these products.
Ordercode Input voltage range Output 1 Output 2 Ripple and noise max.
TYL 05-05S30 5 VDC / 300 mA 6 mVpk-pk TYL 05-12S12 12 VDC / 120 mA 6 mVpk-pk TYL 05-15S10
4.75 – 6 VDC
15 VDC / 100 mA 6 mVpk-pk
TYL 05-05W08 + 5 VDC / 80 mA – 5 VDC/ 80 mA 6 mVpk-pk TYL 05-12W06 +12 VDC/ 65 mA –12 VDC/ 65 mA 6 mVpk-pk TYL 05-15W05 +15 VDC/ 53 mA –15 VDC/ 53 mA 6 mVpk-pk
TVL 05-1220 +12 VDC/ 200 mA –12 VDC/ 200 mA 3 mVpk-pk TVL 05-1225
4.75 – 6 VDC
+12 VDC/ 250 mA –12 VDC/ 125 mA 3 mVpk-pk
TVL 05-1516 +15 VDC/ 165 mA –15 VDC/ 165 mA 3 mVpk-pk TVL 05-1520 +15 VDC/ 200 mA –15 VDC/ 100 mA 3 mVpk-pk
www.tracopower.com Page 2
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input current (no load) TYL models < 95 mA
TVL models < 170 mA
Input current (full load) TYL models 500 mA typ.
TVL models 1’600 mA typ.
Otput Specifications
Voltage set accuracy ± 3 % Regulation – Input variation Vin min. to Vin max. TYL models: ± 0.3 % max.
TVL models: ± 0.03 % max.
– Load variation 0 – 100 % TYL models: ± 0.3 % max.
TVL models: ± 0.18 % max.
Ripple and noise (20 MHz Bandwidth) TYL models: 6 mVpk-pk max.
TVL models: 3 mVpk-pk max.
Temperature coefficient ± 0.02 % / °C
Output current limitation >120 % of Iout max.
Short circuit protection indefinite (automatic rcovery)
General Specifications
Temperature ranges – Operating – 25°C ... +71°C
– Storage – 45°C ... +85°C
Derating 3%/°C above 50°C Efficiency 60% (TVL 05-05W08: 45%)
Humidity (non condensing) 30 – 95 % rel H max. Reliability, calculated MTBF (MIL-HDBK-217 F) >1’000’000h @ + 25 °C Isolation voltage Input/Output 500 VDC Isolation capacity Input/Output 100 pF Isolation resistance Input/Output (500 VDC) > 10 M Ohm Switching frequency TYL models: 70 – 400 kHz depending on load
TVL models: 50 – 300 kHz depending on load
Vibration 5 to 10 Hz amplitude 10 mm pk-pk
10 to 55 Hz acceleration 2 G
Shock acceleration 20 G max. time 11 ms
DC/DC Conver ter
TYL/TVL Series 1.5-5 Watt
Loading...
+ 2 hidden pages