TRACO TMV1215EN, TMV1215DEN, TMV1212EN, TMV1212DEN, TMV1205EN Datasheet

...
Features
Isolation Test Voltage 6’000 Vpk With supplementar y Insulation,
rated for 250 Vrms working Voltage Physical Clearance of Isolation Barrier
2.5 mm min. Certified to IEC/EN 60950 Safety Stan-
DC/DC Converter
TMV-EN Series 1 Watt
2 Year Product Warranty
The TMV-EN series are dc/dc conver ters with supplementary high I/O-isolation, to comply with safety standard IEC/EN 60950. They are designed for applications where approved isolation is required, i.e. information technology equipment or medical equip­ment. SMT-design and a special transformer technology made it possible to build these converters in a ver y small SIP-package, re­quiring a minimum space on the PCB.
Models
Ordercode Input voltage Output voltage Output current max. Efficiency typ.
TMV 0505 EN 5 VDC 200 mA 65 % TMV 0512 EN 12 VDC 80 mA 65 % TMV 0515 EN TMV 0505DEN ± 5 VDC ±100 mA 65 % TMV 0512DEN ±12 VDC ± 40 mA 71 % TMV 0515DEN ±15 VDC ± 30 mA 72 %
TMV 1205 EN 5 VDC 200 mA 65 % TMV 1212 EN 12 VDC 80 mA 65 % TMV 1215 EN TMV 1205DEN ± 5 VDC ±100 mA 65 % TMV 1212DEN ±12 VDC ± 40 mA 73 % TMV 1215DEN ±15 VDC ± 30 mA 74 %
www.tracopower.com Page 1
5 VDC ±10%
12 VDC ±10%
15 VDC 65 mA 65 %
15 VDC 65 mA 65 %
DC/DC Conver ter
TMV-EN Series 1 Watt
Input Specifications
Input current no load /full load 5 Vin models 55 mA / 300 mA typ.
12 Vin models 30 mA / 125 mA typ.
Surge voltage (1 sec. max.) 5 Vin models 9 V max.
12 Vin models 18 V max.
Reverse voltage protection 0.3 A max. Reflected input ripple current can be reduced by ext. 1–3.3 µF polyester film
capacitor
Input filter internal capacitor
Output Specifications
Voltage set accuracy ± 3 % Voltage balance (dual output models) ± 1 % max. Regulation – Input variation ± 1.2 % / 1 % change Vin
– Load variation 20 – 100 % < 10 % Ripple and noise (20 MHz Bandwidth) 120 mV pk-pk typ. Temperature coefficient ± 0.02 % / °C
Short circuit protection limited 1 sec. max. Capacitive load – Single output models 680 µF max.
– Dual output models 220 µF max.
Isolation /Safety
Isolation voltage – Isolation test voltage (tested for 1 sec.) 6‘000 VDC
– Rated isolation voltage 3’000 VDC
Isolation capacity Input/Output 10 pF typ. Isolation resistance Input/Output >1‘000 M ohm Safety standards EN 60950 (rated for 250VAC working voltage)
Safety approvals test report by BSI (British Standard Institute)
General Specifications
Temperature ranges – Operating – 40 °C ... +85 °C
– Case temperature +95 °C max.
– Storage –40 °C ... +125 °C
Derating above 85°C 5 % /°C
Humidity (non condensing) 95 % rel H max. Reliability, calculated MTBF (MIL-HDBK-217 E) >2’000’000 h @ 25 °C Switching frequency 50 kHz typ. (Frequency modulation)
Frequency change over line and load ± 30 % max.
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.