I/O-isolation voltage 1‘600 VDC
Operating temp range –40°C to +95°C
Continuous short circuit protection
Designed to meet UL 62368-1
TEC 2 is a new series with the design purpose to improve the prevalent 2 Watt
SIP-8 DC/DC converters in terms of cost, efficiency and performance. The latest technology and components enable an increase in efficiency by more than
20%. With the reduction of thermal loss, the operating temperature range can
be expanded from -40°C to +95°C. The converters are fully regulated over 0 100% load (no minimum load is required). The low input range is extended
from 4.5 to 13.2 VDC while models are also available with the standard 2:1 input ranges (see TEC 2WI series for 4:1 input ranges). The functional isolation
system is designed to meet EN 62368-1 with 1600 VDC test voltage.
4.5 - 13.2 VDC
(9 VDC nom.)
18 - 36 VDC
(24 VDC nom.)
36 - 75 VDC
(48 VDC nom.)

2 VDC min. / 3 VDC typ. / 4 VDC max.
6 VDC min. / 7 VDC typ. / 8 VDC max.
13 VDC min. / 15 VDC typ. / 17 VDC max.
29 VDC min. / 32 VDC typ. / 35 VDC max.
(The need of an external fuse has to be assessed
in the final application.)
- Input Variation (Vmin - Vmax)
single output models:
- Load Variation (0 - 100%)
- Cross Regulation
(25% / 100% asym. load)
Continuous, Automatic recovery
Output Current Limitation
500 µs typ. (25% Load Step)
- IT / Multimedia Equipment
Designed for EN 62368-1 (no certification)
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.

EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
External filter proposal:
www.tracopower.com/overview/tec2
- Electrostatic Discharge
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 100 A/m, perf. criteria A
EN 61000-4-8, 1000 A/m, perf. criteria A
95% max. (non condensing)
Natural convection (20 LFM)
- Current Controlled Remote
On: open circuit
Off: 2 to 4 mA current (internal 1 kΩ resistor)
External circuit proposal:
www.tracopower.com/info/current-remote.pdf
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
6'620'000 h (MIL-HDBK-217F, ground benign)
Non-conductive Plastic (UL94 V-0 rated)
Silicone (UL 94 V-0 rated)
Wave Soldering
260°C / 10 s max.
THD (Through-Hole Device)
www.tracopower.com/info/reach-declaration.pdf
www.tracopower.com/info/rohs-declaration.pdf
Overview Link (for additional Documents)
www.tracopower.com/overview/tec2
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.

Dimensions in mm (inch)
Tolerances: ±0.5 (±0.02)
Pin pitch tolerances ±0.25 (±0.01)
Pin dimension tolerance ±0.1 (0.004)
2.0
(0.08)
2 x 2.54
(2 x 0.1)
5.08
(0.2)
3 x 2.54
(3 x 0.1)
21.8
(0.86)
0.5
(0.02)
9.1
(0.36)
3.2
(0.13)
11.2
(0.44)
4.1
(0.16)
0.5
(0.02)
1 2 3
Bottom View
5 6 7 8
0.25
(0.01)
Pinout
Pin Single Dual
1
–Vin (GND) –Vin (GND)
2
+Vin (Vcc) +Vin (Vcc)
3
Remote On/Off Remote On/Off
5
NC NC
6
+Vout +Vout
7
–Vout Common
8
NC –Vout
NC: Not connected
© Copyright 2020 Traco Electronic AG Specifications can be changed without notice.