This new DIN-Rail mounting power supplies are designed for industrial and resi-
dential applications. They are lower cost than the existing TBL range, with similar
electrical specifications. Additionally, they fully comply to the new standby power
and efficiency requirements (ECO Standard). They are intended for connect-
ing as class II devices, so the safety earth connection is not required. They are
mountable in flat racks due to their small dimensions in depth. Their dimensions
comply to the DIN 43 880 standard.
Models
Order CodeOutput Power
(max.)
TBLC 06-1056 W
TBLC 06-1126 W
TBLC 06-1246 W
TBLC 15-10512 W
TBLC 15-11215 W
TBLC 15-12415 W
TBLC 25-10520 W
TBLC 25-11224 W
TBLC 25-12425 W
TBLC 50-11248 W
TBLC 50-12450 W
TBLC 75-11272 W
TBLC 75-12475 W
TBLC 90-11290 W
TBLC 90-12490 W
Hold-up time 60 ms min. (at 230 VAC)
15 ms typ. (at 115 VAC)
Start-up – Start up behaviour TBLC 075-112 and 090-112: 0-75 % constant current load other models: 0-100 % constant current load
– Start up time 1 s max.
Ripple and Noise (20MHz bandwidth) 50 mVp-p max.
Current limit (continuous) 105 – 130 % of Iout nom., constant current
Short circuit current 70 – 200 % of Iout nom. (typ.), foldback
Output overvoltage protection 150 % of Vout nom. (typ.)
DC OK signal – trigger threshold ON > 95 % of the set voltage
General Specifications
Operating temperature –25°C to +70°C max.
derating above +55ºC : 2.5%/K
Storage temperature –40°C to +85°C max.
Temperature coefficient 0.02 %/K
Cooling convection cooling, no internal fan
Pollution degree 2
Humidity (non condensing) 5–95 % rel. H max.
Altitude during operation 4800 m max.
Isolation – I/O isolation 3000 VAC (4242 VDC )
Class of protection safety class II
Degree of protection IP 20 (IEC/EN 60529)
* Output voltage can be adjusted as indicated. However, output power has to be maintained at nominal value. This means the output
nominal current has to be reduced in accordance with the increase of output voltage.
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.comPage 2 of 5
TBLC Series, 6 – 90 W
General Specifications (continued)
Safety standards – Information technology equipment– Household applications IEC/EN 60335-1
– Safety of machinery EN 60204
– Safety for power electronic conver ter systems IEC /EN 62477
– Industrial control equipment UL 508
– Class II Power units UL 1310
– NEC class 2 UL 1310 (except TBLC 75-112 and 90-112) – Electronic equipment for power installation E N 5 0178 – Safety of transformers EN 61558-2-8, EN 61558-2-16
– Certification documents (pending)www.tracopower.com/overview/tblc
Electromagnetic compatibility (EMC), Emissions EN 61000-6-3, EN 61204-3
– Conducted RI suppression on input EN 55022 class B,
– Radiated RI suppression EN 55022 class B,
– Harmonic current emissions IEC 61000-3-2 class A
Electromagnetic compatibility (EMC), Immunity EN 61000-6-2, EN 61204-3 – Electrostatic discharge (ESD) IEC/EN 61000-4-2 4 kV/8 kV criteria B
– Radiated RF field immunity IEC/EN 61000-4-3 10 V/m criteria A
– Electrical fast transient / burst immunity IEC/EN 61000-4-4 2 kV criteria B
– Surge immunity IEC/EN 61000-4-5 1 kV/2 kV criteria B
– Immunity to conducted RF disturbances IEC/EN 61000-4-6 10 V criteria A
– Power frequency field immunity IEC/EN 61000-4-8 30 A/m criteria A
– Mains voltage dips and interruptions IEC/EN 61000-4-11
0% / 20ms
40% / 200ms
70% / 500ms
Connection screw terminal with combi-type screwheads
for wire size 0.5 – 2.5mm
IEC/EN 60950-1, UL 60950-1
2
http://www.tracopower.comPage 3 of 5
TBLC Series, 6 – 90 W
V
I short
I max
I nominal
Function Specification
Block Diagram
Current Limit Characteristic
> 70% Inominal
The load characteristic is designed to accomplish reliable start-up of devices requiring full current at reduced output DC voltage.
The maximum current will not exceed 200% of the nominal or 8A, whilst the output power will always be less than 100W for normal and overload operation with nominal output voltages (except TBLC 90-112).
Note: All 6W models (TBLC 06-xxx) implement a pulsing power characteristic when in overload or short circuit conditions
< 200% Inominal
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.comPage 4 of 5
www.tracopower. com
TBLC Series, 6 – 90 W
Outline Dimensions
59.5 mm
ModelWidth (A)
mm
TBLC 006
TBLC 015
TBLC 025
TBLC 050
TBLC 075
TBLC 090
1860
2780
36110
54180
72220
90280
Weigth
g (oz)
45 mm
43.5 mm
54.5 mm
A
89.5 mm
Wiring
AC Input
DC Output
DC Output
Wall Mounting Bracket
Instead of on a DIN-rail, the modules can also be mounted on a chassis or wall with help of a
mounting bracket which is supplied as standard with each power supply
Dimensions in [mm], () = Inch
DescriptionWire sizeTorque
all models: L, N only (2 pin terminal)AWG 20 – 14 / 0.5 – 2.5 mm² max.0.5 Nm
6 – 50 W models: single terminalAWG 20 – 14 / 0.5 – 2.5 mm² max.0.5 Nm