www.tracopower.com Page 2
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input current (no load) 12 Vin models 30 mA typ.
24 Vin models 20 mA typ.
48 Vin models 10 mA typ.
Input current (full load) 12 V in models 1000 mA typ.
24 Vin models 720 mA typ.
48 Vin models 360 mA typ.
Surge voltage protection (1 sec max.) 12 Vin models t.b.a.
24 Vin models t.b.a.
48 Vin models t.b.a.
Conducted noise (input) EN 55022 level A, FCC part 15, level A
Output Specifications
V oltage set accuracy ± 2 %
Regulation – Input variation Vin min. to Vin max. ± 0.5 % max.
– Load variation 10 – 90 %
– single output models ± 1.0 % max.
– dual output models balanced load ± 2.0 % max.
– dual output models unbalanced load ± 3.5 % max.
Ripple and noise (20 MHz Bandwidth) 75 mVpk-pk max.
Temperature coefficient ± 0.05 % / °C
Output current limitation >120% of Iout max., constant current
Short circuit protection Foldback mode
Long term short circuit operation may cause damage
to the converter.
Capacitive load – single output models 200 µF max.
– dual output models 50 µF max.
General Specifications
T emperature ranges – Operating – 25 °C ... + 75 °C (derating 3% /°C above 60°C)
– Case temperature + 100 °C max.
– Storage – 40 °C ... + 125 °C
Humidity (non condensing) 90 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217 E) >1.2 Mio. h @ + 25 °C
Isolation voltage Input/Output
– 12/24 VDC models 750 VDC
– 48 VDC models 1’500 VDC
Isolation capacity Input/Output 2.2 nF typ
Isolation resistance Input/Output (500 VDC) > 1‘000 M Ohm
Switching frequency (fixed) 400 kHz typ. (Pulse width modulation PWM)
Safety standards UL 1950, EN 60950, IEC 60950
Compliance up to 60 VDC input voltage (SELV limit)
Safety approvals UL/cUL File E188913
DC/DC Conver ter
TAP Series 15 Watt