Trace Engineering TRUCK Brochure

Page 1
THE POWER COMPANY
AC Power For Over the Road Trucks
TRUCK SERIES
®
Page 2
AC Power For Long Haul Trucks
120 VAC FROM BATTERIES
Trace Engineering is a world leading manufacturer of high performance Inverter/Chargers. The Truck Series delivers clean 120 VAC 60 Hz power to run standard AC equipment from batteries. Forget the high price and poor perfor­mance of 12 Volt appliances. Improve the quality of life on the road and be more productive by using standard appliances and equipment. Reduce idle time by running from battery power and recharging from shore power.
WHAT CAN I RUN?
If it plugs into the wall, now it can run in the rig. Trace units offer continuous power ratings from 600 to 3000 watts. They are capable of surge power 2 to 3 times their rated output and can hold 150% of rating for 5 to 10 minutes:
• Equipment: Tools, Electric Polisher, , Power Tools
• Electronics: Computer, TV, VCR, FAX, Stereo
• Appliances: Microwave, Refrigerator, Coffee Maker
• Conveniences: Electric Blanket, Fans, Hair Dryer
HOW DOES AN INVERTER WORK?
Wired to the battery bank, the Inverter electronically con­verts 12 VDC into normal household AC power. The output is permanently wired to a power strip or standard electrical outlets. While the engine is running the battery is charged from the alternator and when the engine is off, equipment continues to run for hours from the batteries. With a “shore power” cord you can plug into any AC power (like plug­ging in a block-heater) and the Trace unit passes AC to all
the appliances plus charges the batteries at the same time.
HOURS OF OPERATION FROM BATTERIES
How can a set of batteries run accessories for hours? Truck Series units have very high efficiencies over their whole power range. High efficiency means less battery is used to run loads, so the battery power lasts longer. Moreover, when no AC loads are running the search mode draws less than 1/2 watt so the by itself can’t run down the battery even if left “On” for days.
inverter
ALTERNATOR
APPLIANCES
TV
VCR
OUTLETS
TRACE INVERTER/ CHARGER
SHORE POWER
BATTERY BANK
SAFETY AND RELIABILITY
All Trace Truck Series Inverter/Chargers are UL or ETL listed to tough UL and CSA standards for performance and safety. Charger versions include transfer switching and ground switching to meet safety code requirements. Trace units also include protection against short circuit, AC back-feed, over temperature, and under/over voltage. The Truck Series has been proven in million mile vehicles and is backed by a full two-year warranty.
Page 3
AC Power Capacity
Menu Item
Setup
Meter
Inverter On / Off Settings
Inverter Charge Batt Full
Error
REMOTE CONTROL
RC7
SERIES I
T6112 - T1112 - T1412
Series I is intended to deliver a tough no-nonsense machine for tight spots and lots of power. Perfect for under-bunk installation and ready to hard-wire to an AC outlet or power strip, these units pack enough power to run most accessories. The optional 3 stage built-in charger can crank batteries back to full within hours (and comes with a built-in 30 amp transfer switch). The optional RC8 remote control means you can bury the unit and still control it from the dashboard or living area.
All the Power You Need
With models from 600 watts to 3 kilowatts, there is a unit for any budget. The Truck Series is designed to run serious loads like motors and microwaves. Most models can surge up to three times rated output for starting punch. In overload, they can deliver twice their rated power for up to five minutes, allowing several jobs at the same time without nuisance shut downs.
SERIES II
T2012 - T2512 - T3012
Delivering up to 3000 watts, Series II sets the industry standard for power, perfor­mance and programmable features. The built-in 3 stage charger and 30 amp transfer switch is standard. This larger capacity lets you run many loads at the same time. The RC7 full function remote can adjust all programmable settings plus ac­cesses the built-in Battery Fuel Gauge. The fuel gauge monitors the battery and reads in bar graph, % full or time remaining. It also gives time left to recharge when in charge mode.
Save Your Battery
Deep discharge of your battery can leave you stranded, and it’s the number one cause of expensive battery replacement. The Truck Series has battery protection which shuts down the AC output before your battery voltage is dangerously low. So you always have cranking power.
Transparent Connection to “Shore Power”
Whether it’s an extension cord run to the shop or a plaza hook-up, more and more locations offer the ability to hook up to “shore power”. The Truck Series has a built-in 30 amp transfer switch so you can plug in and every­thing keeps running automatically. The transfer feature meets all UL and NEC safety code requirements.
Accessories
Safety and performance dictate a quality installation with high performance components and accessories. Install Truck Series Units “out-of-sight” and keep control with a remote.
RC8 Remote Control For Series I
On/Off switch and LED status/fault indicators
RC6 Remote Control For Series II
On/Off control, LEDs give DC voltage/charging current and status lights
RC7 Full Function Programmable Remote For Series II
Backlit LCD screen gives full function programmability including all inverter and charger set points as well as Battery Fuel Gauge.
Trace Fuse Blocks offer protection and code compliance for your DC installation. 110, 200, 300 and 400 amp available.
RC8
REMOTE CONTROL
Inverter Status
Push On/Off
Solid Red
Inverting or Charging
Blinking Slow
Search Mode
Blinking Fast
Error
RC8 Remote
RC7 Remote
Page 4
Technical Specifications
SERIES I
SERIES II
Model T612 T1112 T1412 T2012 T2512 T3012
Continuous Power @ 25 C 600 VA 1100 VA 1400 VA 2000 VA 2500 VA 3000 VA
Continuous Current @ 25 C 5 amps AC 9 amps AC 12 amps AC 16.6 amps AC 20.8 amps AC 28 amps AC Maximum Current (100 mSec Record) 18 amps AC 22 amps AC 30 amps AC 39 amps AC 46 amps AC 53 amps AC
Maximum Power (Light Bulb Rating) 2500 W 3000 W 3400 W 4500 W 5200 W 6000 W
Efficiency (peak) 92% max 90% max 92% max 94% max 94% max 94% max Input Current Search Mode 0.045 amps 0.022 amps 0.060 amps 0.055 amps 0.070 amps 0.080 amps At Rated Power 63 amps 120 amps 153 amps 220 amps 275 amps 330 amps Nominal Input Voltage 12 vdc 12 vdc 12 vdc 12 vdc 12 vdc 12 vdc Input Voltage Range 10.8-15.5 vdc 10.8-15.5 vdc 10.8-15.5 vdc 10.2-15.5 vdc 10.2-15.5 vdc 10.2-15.5 vdc Low Battery Cutout 9.5-11.8 vdc 9.5-11.8 vdc 9.5-11.8 vdc 9.5-11.8 vdc 9.5-11.8 vdc 9.5-11.8 vdc High Voltage Cutout 15.7 vdc 15.7 vdc 15.7 vdc 15.7 vdc 15.7 vdc 15.7 vdc Voltage Regulation-Maximum ±2.5% typical ±2.5% typical ±2.5% typical ±5% ±5% ±5% Voltage Regulation-Minimum ±2.5% ±2.5% ±2.5% ±2.5% ±2.5% ±2.5% Output Waveform Modified sine Modified sine Modified sine Modified sine Modified sine Modified sine Power Factor Allowed 0 to 1 0 to 1 0 to 1 -1 to +1 -1 to +1 -1 to +1
Frequency Regulation 60 Hz ± .01% 60 Hz ± .01% 60 Hz ± .01% 60 Hz ± .04% 60 Hz ± .04% 60 Hz ± .04% Standard Output Voltage 120 vac 120 vac 120 vac 120 vac 120 vac 120 vac Automatic Transfer Relay 30 amps 30 amps 30 amps 30 amps 30 amps 30 amps Battery Charger 25 amps 50 amps 50 amps 100 amps 120 amps 140 amps
Environmental Characteristics SERIES I & SERIES II
Enclosure Type Indoor, ventilated, steel chassis with powdercoat finish Specified Temperature Range 32oF to 104oF (0oC to + 40oC) (Output will meet specified tolerances) Allowed Operating Temperature Range -40oF to 140oF (-40oC to + 60oC) (output may not meet specified tolerances) Dimensions (10.5" high, 15.5" wide, 6" deep) (13.125" high, 7.125" wide, 13.875" deep) Mounting Wall or Shelf Mount
THE POWER COMPANY
Arlington • WA • USA Phone: 360-435-8826
Fax: 360-435-2229
POWER CONVERTERS/INVERTERS AND
U
POWER CONVERTER/INVERTER SYSTEMS
L
FOR LAND VEHICLES STANDARD UL458
®
COMMERCIAL AND INDUSTRIAL POWER SUPPLIES - CERTIFIED TO CAN/CSA-222
®
U
L
No. 107.1-M91
®
POWER CONVERTERS AND POWER CONVERTER SYSTEMS FOR RECREATIONAL VEHICLES STANDARD UL458
COMMERCIAL AND INDUSTRIAL POWER SUPPLIES CERTIFIED TO CAN/CSA-C22.2 NO. 107-1-M1
ETL TESTING LABS. INC. CORTLAND, N.Y.
Available From:
Loading...