SPECIFICATIONS Timing Capacity: Timing Increments:
23 Hours, 59 Minutes, 59 Seconds.
1/100th of a second (under 30
minutes) 1 second (over 30 minutes)
Accuracy: Timing Features:
1/1000 of a second at 25°C
Continuous, Cumulative Split, Time­Of-Day, Date, Alarm.
SINGLE ACTION TIMING
Press the MODE button until you are in the stopwatch
1.
mode (The stopwatch mode is indicated by ashing
“SU” “FR” “SA”).
Press the LAP/RESET button to clear the display to
2. zero.
The rst press of the START/STOP button starts the
3. stopwatch timing. (This is indicated by the blinking colon)
4.
The second press of the START/STOP button stops
the stopwatch timing. (This is indicated by the non­blinking colon)
After the time is recorded, press the LAP/RESET
5. button to clear the display to zero. RESET will only clear the display to zero after the stopwatch has been stopped.
TIME-IN/TIME-OUT TIMING
1.
Press the MODE button until you are in the stopwatch
mode. (Flashing “SU” “FR” “SA”)
Press the LAP/RESET button to clear the display to
2. zero.
The rst press of the START/STOP button starts the
3. stopwatch timing. (Blinking colon)
4.
The second press of the START/STOP button stops
the stopwatch timing. (Non-blinking colon) The stop­watch will hold the reading where stopped (Time-Out).
The third press of the START/STOP button starts the
5. stopwatch at the point that it was previously stopped (Time-In). Any number of Time-Out/Time-In intervals may be taken.
At the end of the timing, press the START/ STOP but-
6. ton to stop the stopwatch, record the time, and then press the LAP/RESET button to clear the display to zero. RESET only clears the display to zero when the stopwatch has been stopped.
CONTINUOUS TIMING
For timing which lasts for over 24 hours, the stopwatch instantly rolls over to zero when the maximum display is reached, and continues timing. Simply make note of the days which have elapsed.
CUMULATIVE SPLIT TIMING
Cumulative split timing freezes the display for partial times while the internal dock continues to run and mea-
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
sure total elapsed time. Each press of the LAP/RESET button captures the split cumulative timing or displays the running time.
Press the MODE button until you are in the stopwatch
1. mode. (Flashing “SU” “FR” “SA”)
Press the LAP/RESET button to clear the display to
2. zero.
3.
The rst press of the START/STOP button starts the
stopwatch timing. (Blinking colon)
The rst press of the LAP/RESET button “freezes” the
4. display for recording a time while the internal clock continues to run. The blinking colon indicates the internal dock is running.
The second press of the LAP/RESET button releases
5. the display. The display is instantly updated to the cumulative running time.
Successive presses of the LAP/RESET button will
6. “freeze” or release the display. Any number of splits may be taken.
At the end of the last event, press the START/STOP
7. button to stop the stopwatch and press the LAP/ RESET button to clear the display to zero. RESET only clears the display to zero when the stopwatch has been stopped.
While the stopwatch is running, you can save two fast
times by pressing the LAP/RESET button rst and the
START/STOP button second. The non-blinking colon indicates the event time is stopped. The display will show
the time of the rst event. Release this “frozen split” by
pressing the LAP/RESET button again. The total time of the last event will be displayed. Press the LAP/RESET button to clear the display to zero.
SETTING TIME-OF DAY/DATE
1.
Press the MODE button until you are in the clock
mode.
Press the MODE button twice. The unit will display the
2.
alarm time with the hour digits ashing and a ashing
bar will appear above MO.
Press the MODE button again. The unit will display the
3.
time-of-day with the seconds ashing and a ashing
bar will appear above TU.
Press the START/STOP button to set the seconds
4. to zero. (If the seconds are above 30, then pressing START/STOP will reset the seconds to zero and advance the minutes by one).
Press the LAP/RESET button and the minutes will
5.
ash.
Press the START/STOP button to advance the
6. minutes. Note: Pressing the button a single time will advance the display by one, press and hold the button to advance the display rapidly.
7.
Repeat steps 5 and 6 to set hours, month, date, and
day. Note: When setting hours, an A or P next to the minutes indicates AM/PM time, an H indicates 24-hour time. To display the time in 24-hour format; when
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
hours is selected, press the START/STOP button until H appears next to the minutes.
8.
When nished, press the MODE button to record the
changes and return to the clock mode.
To display the date, press and hold down the START/ STOP button. (Note: You must be in the clock mode)
TO SET ALARM TIME
Press the MODE button until you are in the dock
1. mode.
Press the MODE button twice. The unit will display the
2.
alarm time with the hour digits ashing and a ashing
bar will appear above MO.
Press the START/STOP button to advance the hours.
3. Note: Pressing the button a single time will advance the display by one, press and bold the button to advance the display rapidly.
Press the LAP/RESET button. The minutes will ash.
4.
Press the START/STOP button to advance the
5. minutes. Note: Pressing the button a single time will advance the display by one, press and hold the button to advance the display rapidly.
Press the MODE button to return to the clock mode.
6.
ALARM
To turn the alarm on or oft, press the MODE button until you are in the time-of-day display. Press and continue to hold down the LAP/ RESET button and press the START/ STOP button. Each press of the START/STOP button successively turns the alarm @))) on or off. When the alarm is activated, @))) will appear in the box above the seconds. When the alarm time is reached, the alarm will sound for one minute and then automatically turn off to preserve the battery life. A sounding alarm may be turned oft by pressing either of the buttons on top of the unit.
BATTERY INFORMATION
A faint display, incorrect display or no display are all indicators that the battery must be replaced. To replace the battery, turn the battery cap on the back counter­clockwise from the CLOSE position to the OPEN position. Remove the battery cap, Remove the exhausted battery and place a new battery in the unit with the positive side visible to you. Replace the battery cap. Turn the battery cap from OPEN position to the CLOSE position. Equiva­lent replacement batteries are Ray-O-Vac 392, Everready 392 or Duracell D392.
To display the alarm time, press and hold down the LAP/ RESET button. (Note: You must be in the clock mode)
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
WARRANTY, SERVICE, OR RECALIBRATION
For warranty, service, or recalibration, contact:
Traceable® Products is ISO 9001:2015 Quality-
Certied by DNV and ISO/IEC 17025:2005
accredited as a Calibration Laboratory by A2LA.