![](/html/01/0181/018174bb33fbf2c7ad3108e232595b99e68532afc3b850e10d7af0d09b6e1cda/bg1.png)
INFRARED THERMOMETER
TE1005
Instruction Manual
1 Features:
• Precise non-contact measurements
• Built-in laser pointer
• Automatic selection range and Resolution to 0.1ºor 1º
• °C/°F switchable button
• Automatic Data Hold & Auto power off
• The meter at 12 inches away measure 1 inch target
• Backlit LCD display
2 Wide range application:
Food preparation, Safety and Fire inspectors, Plastic molding, Asphalt,
Marine and screen printing, measure ink and dryer temperature, Diesel and Fleet maintenance.
3 Field of View
The meter’s field of view is 12:1, meaning that if the meter is 12 inches from the target, the diameter of the object under test must be at least 1
inch. Other distances are shown below in the field of view diagram. Refer to the chart printed on the meter for more information.
Laser Beam
Distance(D) to Spot Size(S)
1.0@12
3.0@36
5.0@60
16mm
inch
Sensor Beam
25@300
D:S=12:1
75@900
125@1500
mm
Fig: 1
1. SAFETY
z Use extreme caution when the laser beam is turned on.
z Do not let the beam enter your eye, another person’s eye or the eye of an animal.
z Be careful no to let the beam on a reflective surface strike your eye.
z Do not allow the laser light beam impinge on any gas which can explode.
2. SPECIFICATIES
z General specifications
Display 3½ digital LCD screen with backlight
Measuring range / resolution -50.0°C to 750°C /-58.0°F to 1382°F (0.1°C to 200°, 1° over 200°).
Response time Less than 1 second.
Over range indication LCD will show “1”.
Polarity Automatic (no indication for positive polarity); Minus (-) sign for negative
polarity
Emissivity 0.95 fixed value
Field of view D/S = Approx. 12:1 ratio (D = distance; S = spot (Has 90% encircled energy
at the focal point)
Diode laser Output <1mW, Wavelength 630~670nm, class2 (II) Laser product.
Spectral response 8~14µm.
Power off Automatic shut off after apprx. 7 seconds
Operating temperature 0°C to 50°C (32°F to 122°F).
Storage temperature -20°C to 60°C (-4°F to140°F).
![](/html/01/0181/018174bb33fbf2c7ad3108e232595b99e68532afc3b850e10d7af0d09b6e1cda/bg2.png)
Relative humidity 10%~90%RH operating, <80%RH storage
Power supply 9V battery, NEDA 1604A or IEC 6LR61.
Weigth 290g.
Dimensions 100 x 56 x 230mm.
z Infrared thermometer specifications
Range (auto. selection 0.1°C/1°C) Resolution Accuracy
-50.0°C to -20.0°C ± 5°C; -50.0°C to 200.0°C
-20.0°C to 200.0°C
201°C to 538°C ± 2% of reading ± 2°C;
539°C to 750°C
0.1°C
± 1.5% of reading ± 2°C;
1°C
± 3.5% of reading ± 5°C.
Range(auto. selection 0.1°F/1°F Resolution Accuracy
-58.0°F to -4.0°F ± 9°F; -58.0°F to 200.0°F
-4.0°F to 200.0°F
201°F to 1000°F ± 2% of reading ±°F;
1001°F to 1382°F
0.1°F
± 1.5% of reading ± 4°F;
1°F
± 3.5% of reading ±9°F.
Note:
Accuracy is given at 18 oC to 28 oC (64
o
F to 82 oF), less than 80 % RH.
Field of View:
Make sure that the target is larger than the unit’s spot size. The smaller the target, the closer you should be to it. When accuracy is critical, make
sure the target is at least twice as large as the spot size.
Emissivity: 0.95 fixed value
3. FRONT PANEL DESCRIPTION
① IR sensor
② Laser pointer beam
③ LCD Display
④ °F select key
⑤ ℃ select key
⑥ Backlight select key
⑦ Laser select key
⑧ Measurement Trigger
⑨ Handle Grip
⑩ Battery Cover
S
C
A
N
H
O
L
3
5
6
D
¡
ã
C
¡
ã
F
+
-
2
1
4
7
8
4. INDICATOR
① Digital readout
② Temperature ℃ (Celsius)
9
10
③ Temperature ℉ (Fahrenheit)
④ Measuring indication
⑤ Data Hold
⑥ LOW battery indicator
⑦ Laser Point
⑧ Fixed emissivity (0.95)
4
5
1
2
6
3