PRODUCT DESCRIPTION .................................................................................. 2
GENERAL SPECIFICATIONS.............................................................................. 2
OPERATING PRECAUTIONS.............................................................................. 3
INSTALLATION .................................................................................................... 4
MAINTENANCE ................................................................................................... 4
METERING AND INDICATORS ........................................................................... 5
OPERATOR ADJUSTMENTS .............................................................................. 6
REMOTE MONITORING ...................................................................................... 8
APPENDIX I ......................................................................................................... 9
HMS ILLUSTRATION......................................................................................... 10
WARRANTY ....................................................................................................... 12
Page 1
PRODUCT DESCRIPTION
The HMS series of TPL power amplifiers are intended for use in base station or repeater applications. They are high power units and in various configurations cover the frequency range extending form Low Band VHF to 960 MHz.
An HMS series RF power amplifier is a self contained unit which allows operation, metering, and remote monitoring of all parameters of an RF power amplifier. Its major components are: enclosure, front panel, rear panel, power amplifier, power supply, cooling fans, metering, control, and monitoring circuits. The entire assembly is designed to be installed in a nineteen inch rack.
For operator convenience views of the front and rear of the amplifier are presented in the illustrations section of APPENDIX 1.
GENERAL SPECIFICATIONS
MODEL: PA9096-350
FREQUENCY RANGE: 920-940 MHz
POWER INPUT: 100 mW – 50 W (model dependent)
NOMINAL POWER OUTPUT: 350 watts
EIA DUTY CYCLE: 100% / Continuous.
MODULATION MODE: FM.
IN/OUT RF CONNECTORS: Type “N” – IN; 7/16 DIN - OUT
OPERATING TEMPERATURE RANGE: -20º to +50º Celsius.
OPERATING VOLTAGE: 110 VAC Standard, 220 VAC Optional.
HARMONICS and SPURIOUS EMISSION ATTENUATION: Meets or exceed FCC type acceptance requirements.
CIRCUIT PROTECTION: Provided by the circuit breaker.
REMOTE MONITORING: A DB-25 connector for remote access to metering and indicators is a
standard feature on all HMS RF amplifiers (See Table 1).
OPERATING HUMIDITY: 0%-85% RH (Non-condensing).
STORAGE HUMIDITY: 0% -95% RH (Non-condensing).
Page 2
CAUTION!
Check the amplifier upon receipt for visible damage. If any is noticed, please call TPL at 800 HI POWER to request an RMA number (Return Material Authorization). If purchased through a dealer, ask them to follow this procedure for best results.
EXPENSIVE COMPONENTS MAY BE DESTROYED IF THE AMPLIFIER IS TURNED ON IN A DAMAGED CONDITION.
OPERATING PRECAUTIONS
CAUTION: This amplifier produces RF voltages that can cause painful and dangerous RF
burns. Use caution! Connect and disconnect all RF connectors with the AC power and drive power off.
DRIVE POWER: RF power transistors, although quite rugged in most respects, are easily damaged by overdrive. Be careful no to overdrive this amplifier, even for an instant. Higher than rated drive power may destroy the transistors and VOID ANY WARRANTY.
TERMINATIONS: The parameters of this amplifier will degrade if it is operated into anything but a 50 Ohm load. That may mean any, or all, of the following; lower power output, increased current drain, higher operating temperature, lower efficiency and reduced lifetime.