1.Congratulations: Thank you for purchasing TPI products. The SP620 is
easy to use and built to last. It is backed by a 3 year limited warranty
2.Product Description: The SP620 is a differential manometer “Smart
Probe”. It connects to your mobile device and uses the TPI Smart
Probe App to display temperature readings. Data can be exported to a
CSV file as well.
B.SAFETY CONSIDERATIONS
1.Never attach the SP620 to a hot surface.
2.Always ensure the pressure being measured does not exceed the capability of the SP620.
3.Never use the SP620 to measure liquid pressure.
4.Do not expose the unit to damp environments for extended periods of
time.
1.Input connection for pressure measurements. Inputs are
marked + and -.
2.SP620 status LED indicator.
Orange and blinking = Bluetooth not connected
Green and blinking = Bluetooth connected
Blinking Red with either of the above = Low battery
3.Power Key. Press and hold to turn the instrument on.
Press and hold to turn the instrument off.
4.Built-in magnet. Attach to
metal surfaces for hands free
operation. Ensure surface is
not hot.
5.Serial number location. Last
three digits are the product
identification number and
marked in bold. Use this number to distinguish between
models when several SP620’s
are connected to a phone or
tablet.
6.Screw to open battery compartment. Turn the screw
counter clockwise until it is
just above the compartment
door. Lift on the screw to open
the compartment.
The inputs are marked + and -. Any pressure connected to the - port will be subtracted from the + port. For standard pressure / vacuum measurements use the +
port only. Use the + and - port when performing differential measurements.
1. Download and install the TPI
Smart Probe App onto your
mobile device. Run the App. The
“Main-Real Time” screen will be
displayed.
The App will say “No Devices”
until a smart probe has been
connected.
2. Press and hold the SP620 On/Off
key down until it turns on. The
LED indicator will initially be
orange and blink.
The SP620 will auto connect to
your mobile device. The LED
indicator will turn Green and
blink to indicate a link has been
established. The App will display
the model and ID number of the
smart probe connected.
If the SP620 does not auto connect tap refresh on the App.
Refresh
This also clears any data
accumulated.
Displays the measured
pressure.
3. Tapping the list icon allows
optional functions to be
accessed. These include
Show/Hide, Unit, and Zeroing
Sensors.
Set the units of measure at this
time.
Show/Hide : Allows a device
to be seen or hidden. Useful
when multiple devices are
connected.
Unit : Switch between units
of pressure.
Zeroing Sensors: Used to
zero the SP620. (See page
7. Tap the Reset icon to set the pressure reading to 0 (+/- 0.05
counts)
8. Tap Close to return to normal operation.
4. Connect tubing to the SP620. For a standard measurement
connect tubing to the + port and leave the - port open. For a
differential measurement connect tubing to the + and - ports.
5. Tap the list icon to bring up the options menu.
6. Select “Zeroing Sensors” to bring up the field calibration
screen.
7. Tap the + icon to select the SP620 to be zeroed.
8. Tap the SP620 to be zeroed.
9. Connect the tube(s) to the device under test and read the
pressure. Examples are:
1. Tap the Drop Down Menu icon to access additional features.
Main - Real Time: Tapping this returns you to the main screen.
Select Application: Tapping this pulls up sub applications for
variious smart probes. These include Temperature differential
(SP341), Air Volume Calulation (SP565), and Tightness Test
(SP620). Note: There are no sub applications for the SP1000.
Company Info: Allows you to enter your information to show up
on the CSV file report. You can enter your company name,
address, and email.
Customer Info: Allows you to enter the information of the customer the tests are being performed for. You can enter the customer name, address, and email. You can also enter the building
information in cases where the tests are being performed somewhere off-site from the customer.
Exit: Closes the Smart Probe App.
The Smart Probe App has a Drop Down menu allowing access to additional app features.
1. Tap the Drop Down Menu icon to access additional features.
2. Select “Company Info” to enter your information to show up on
the CSV file report. You can enter your company name, address,
and email.
3. Select “Customer Info” to enter the information of the customer
the tests are being performed for. You can enter the customer
name, address, and email. You can also enter the building information in cases where the tests are being performed some
-
where off-site from the customer.
The Smart Probe App allows you to enter your company information and the customer
information who the test is being performed for. This information will be exported in the
CSV file (see page 4).
I. PERFORMING TIGHTNESS TEST
1. Tap the Drop
Down Menu icon
to access addi
-
tional features.
The SP620 and smart probe app provide the capability of performing a standing pressure
or Tightness Test/. This test is mostly used in Europe and is a way to check for leaks in
sealed systems.
2. Tap “Select
Application”.
3. Select “Tightness
Test”.
4. Tap the + icon
7
to select the
SP620 to use
for the meas-
Note: The other
urement.
applications shown
are for different
model smart probes
1. Turn the battery
compartment screw
counter clockwise
until it is just above
the compartment
door. Lift on the
screw to open the
compartment.
2. Replace the three
AAA batteries.
3. Re-install the battery cover and tighten the
screw by turning it clockwise.
M. WARRANTY
This product is warranted to the purchaser against defects in material and workmanship for three years from the
date of purchase.
Covered by Warranty: Repair parts and labor; or replacement of the product at company’s option. Normal transportation charges to the purchaser are also covered.
Not Covered by Warranty: Damages to the product which are the result of abuse, improper use or maintenance are
not covered. Any other expense, consequential damages, incidental damages, or incidental expenses including damages to property are not covered. Transportation expenses to the company are not covered.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
To Obtain Warranty Performance: Include with the product: your name, address, phone number, written description of the problem and proof of purchase date. Carefully package and return to:
Implied Warranties: Any implied warranties including implied warranties of merchantability and fitness for a particular purpose, are limited in duration to three years from date of purchase. To the extent any provision of this warranty is prohibited by federal or state law and cannot be preempted, it shall not be applicable. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state.