TPI TPI1471 Owner Manual

Page 1
Page 2
Amperage Chart & Electric Heat Products Limited Warranty
277
2
K.W
B.T.U.H.
Rating
00.5 1,706 2.4 1.4 2.3 1.3 2.2 1.3 2.1 1.2 1.8 0.6 0.6 0.5
01.0 3,413 4.8 2.8 4.5 2.6 4.3 2.5 4.2 2.4 3.6 1.3 1.2 1.0
02.0 6,826 9.6 5.5 9.1 5.2 8.7 5.0 8.3 4.8 7.2 2.6 2.4 2.1
03.0 10,239 14.4 8.3 13.6 7.9 13.0 7.5 12.5 7.2 10.8 3.9 3.6 3.1
04.0 13,652 19.2 11.1 18.2 10.4 17.5 10.1 16.6 9.6 14.4 5.2 4.8 4.2
05.0 17,065 24.0 13.8 22.7 13.1 21.7 12.6 20.8 12.0 18.1 6.6 6.0 5.2
06.0 20,478 28.8 16.6 27.3 15.7 26.1 15.1 25.0 14.4 21.7 7.9 7.2 6.3
07.0 23,891 33.6 19.4 31.8 18.4 30.4 17.6 29.1 16.8 25.3 9.2 8.4 7.3
08.0 27,304 38.5 22.2 36.4 20.9 34.9 20.1 33.3 19.2 28.9 10.5 9.6 8.4
09.0 30,717 42.8 24.9 40.9 23.3 39.1 22.6 37.7 21.4 32.5 11.8 10.8 9.5
10.0 34,130 48.1 27.4 45.4 26.2 43.5 25.1 41.7 24.0 36.1 13.2 12.0 10.5
11.0 37,543 52.9 30.5 50.0 28.6 47.8 27.6 45.8 26.4 39.7 14.5 13.2 11.6
12.0 40,956 57.7 33.2 54.5 31.5 52.1 30.2 50.0 28.6 43.3 15.8 14.4 12.6
13.0 44,369 62.5 36.0 59.1 34.1 56.9 32.7 54.2 31.3 46.9 17.1 15.6 13.7
14.0 47,782 67.3 38.8 63.6 36.7 60.9 35.2 58.3 33.7 50.5 18.4 16.8 14.7
15.0 51,195 72.1 41.5 68.2 39.1 65.2 37.7 62.5 35.1 54.2 19.8 18.0 15.8
16.0 54,608 76.9 44.3 72.7 41.9 69.6 40.2 66.7 38.5 57.8 21.1 19.2 16.9
17.0 58,021 81.7 47.1 77.3 44.3 73.9 42.7 70.8 40.9 61.4 22.4 20.4 17.9
18.0 61,434 86.5 49.8 81.8 47.2 78.3 45.2 75.0 43.3 65.0 23.7 21.6 19.0
19.0 64,847 91.3 52.6 86.4 49.6 82.6 47.7 79.2 45.7 68.6 25.1 22.8 20.0
20.0 68,260 96.1 55.1 90.9 52.5 86.9 50.3 83.3 48.1 72.2 26.4 24.0 21.1
21.0 71,673 100.0 58.2 95.6 55.1 91.3 52.9 87.5 50.5 75.8 27.7 25.2 22.1
22.0 75,086 105.8 60.9 100.0 57.7 95.7 55.3 91.7 52.9 79.4 29.0 26.4 23.1
23.0 78,499 110.6 63.7 14.5 60.4 100.0 57.9 95.8 55.3 83.0 30.3 27.6 24.3
24.0 81,912 115.4 66.5 109.1 62.9 104.3 60.3 100.0 57.7 86.6 31.7 28.8 25.3
25.0 85,325 120.2 69.2 113.6 65.3 108.6 62.8 104.1 60.1 90.3 33.0 30.1 26.4
26.0 88,738 125.0 72.0 118.2 68.3 113.0 65.3 108.3 62.5 93.9 34.3 31.3 27.4
27.0 92,151 129.8 74.8 122.7 70.9 117.4 67.8 112.5 64.7 97.5 35.6 32.5 28.5
28.0 95,564 134.6 77.2 128.2 73.5 121.7 70.3 116.6 67.3 101.1 36.9 33.7 29.5
29.0 98,977 139.4 80.3 131.8 76.0 126.0 72.9 120.8 69.7 104.7 38.3 34.9 30.6
30.0 102,390 144.2 83.1 136.4 78.7 130.4 75.4 125.0 72.1 108.3 39.6 36.1 31.7
31.0 105,803 149.0 85.9 140.9 81.3 134.7 77.9 129.2 74.5 111 .9 40.9 37.3 32.7
32.0 109,216 153.8 88.7 145.4 83.9 139.0 80.4 133.4 76.9 115.5 42.2 38.5 33.8
33.0 112,629 158.6 91.5 149.9 86.5 143.3 82.9 137.6 79.3 119.1 43.5 39.7 34.8
34.0 116,042 163.4 94.3 154.4 89.1 147.6 85.4 141.8 81.7 112.7 44.8 40.9 35.9
35.0 119,455 168.2 97.1 158.9 91.7 151.9 87.9 146.0 84.1 126.4 46.1 42.1 36.9
36.0 122,868 173.0 99.9 163.4 94.3 156.2 90.4 150.2 86.5 130.0 47.4 43.3 38.0
37.0 126,281 177.8 102.7 167.9 96.9 160.5 92.9 154.4 88.9 133.6 48.7 44.5 39.0
38.0 129,694 182.6 105.5 172.4 99.5 164.8 95.4 158.6 91.3 137.2 50.0 45.7 40.1
39.0 133,107 187.4 108.3 176.9 102.1 169.1 97.9 162.8 93.7 140.7 51.3 46.9 41.1
40.0 136,520 192.2 111 .1 181.4 104.7 173.4 100.4 167.0 96.1 144.4 52.6 48.1 42.2
41.0 139,933 197.0 113.9 185.9 107.3 177.7 102.9 171.2 98.5 148.0 53.9 49.3 43.2
42.0 143,346 201.8 116.7 190.4 109.9 182.0 105.4 175.4 100.9 151.6 55.2 50.6 44.3
43.0 146,759 206.6 119.5 194.9 112.5 186.3 107.9 179.6 103.3 155.2 56.5 51.8 45.3
44.0 150,172 211.4 122.3 199.4 115.1 190.6 110.4 183.8 105.7 158.8 57.8 53.0 46.4
45.0 153,585 216.2 125.1 203.9 117.7 194.9 112.9 188.0 108.1 162.5 59.1 54.2 47.4
46.0 156,998 221.0 127.9 208.4 120.3 199.2 115.4 192.2 110.5 166.1 60.4 55.4 48.5
47.0 160,411 225.8 130.7 212.9 122.9 203.5 117.9 196.4 112.9 169.7 61.7 56.6 49.5
48.0 163,824 230.6 133.5 217.4 125.5 207.8 120.4 200.6 115.3 173.3 63.0 57.8 50.6
49.0 167,237 235.4 136.3 221.9 128.1 212.1 122.9 204.8 117.7 176.9 64.3 59.0 51.6
50.0 170,650 240.2 139.1 226.4 130.7 216.4 125.4 209.0 120.1 180.5 65.6 60.2 52.7
51.0 174,063 245.0 141.9 230.9 133.3 220.7 127.9 213.2 122.5 184.1 66.9 61.4 53.7
52.0 177,476 249.8 144.7 235.4 135.9 225.0 130.4 217.4 124.9 187.7 68.2 62.6 54.8
53.0 180,889 254.6 147.5 239.9 138.5 229.3 132.9 221.6 127.3 191.3 69.5 63.8 55.8
54.0 184,302 259.4 150.3 244.4 141.1 233.6 135.4 225.8 129.7 194.9 70.8 65.0 56.9
55.0 187,715 264.2 153.1 248.9 143.7 237.9 137.9 230.0 132.1 198.6 72.2 66.2 57.9
56.0 191,128 269.0 155.9 253.4 146.3 242.2 140.4 234.2 134.5 202.2 73.5 67.4 58.8
57.0 194,541 273.8 158.7 257.9 148.9 246.5 142.9 238.4 136.9 205.8 74.9 68.6 59.9
58.0 197,954 278.6 161.5 262.4 151.5 250.8 145.4 242.6 139.3 209.4 76.2 69.8 60.9
59.0 201,367 283.4 164.3 266.9 154.1 255.1 147.9 246.8 141.7 213.0 77.5 71.0 62.3
60.0 204,780 288.2 167.1 271.4 156.7 259.4 150.4 251.0 144.1 216.6 78.8 72.2 63.0
Note: All custom built products are subject to 100% cancellation/ restock charges.
208 Volt
AMP Rating
1 PH 3 PH 1 PH 3 PH 1 PH 3 PH 1 PH 3 PH 1 PH 3 PH 3 PH 3 PH
220 Volt
AMP Rating
230 Volt
AMP Rating
240 Volt
AMP Rating
Rating
Volt
AMP
440 Volt
AMP
Rating
Heat Products
198 Series Elements 1 Year
Elements in Baseboard 10 Years
480 Volt
AMP
Rating
550 Volt
AMP
Rating
Products manufactured by TPI Corporation are warranted to the original consumer to be free from defects in material and workmanship for twelve (12) months from the original date of purchase. The TPI
warranty does not cover products modied
There are no obligations or liabilities on the part of the corporation for consequential damages arising out of, or in connection with, the use or performance of the product, or other indirect damages with respect to loss
of property, revenues, or prot, or costs of
removal, installation or reinstallation.
All implied warranties with respect to TPI products, including implied warranties for merchantability and implied warranties for
tness, are limited in duration to twelve
(12) months from original date of purchase, except those products or parts of products which are warranted for longer periods. On such products or parts of products all implied
warranties for merchantability and tness
are limited to the duration of the extended warranty period thereon.
Some states do no allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts. The above exclusions or limitations may not apply to you.
During the warranty period, TPI Corporation will, at its sole option, repair or replace any defective parts or products returned, freight prepaid, to the TPI Corporation factory or such other location as TPI Corporation may designate. Returned products must be packaged carefully and TPI Corporation shall not be responsible for damage in transit. When returning parts, the owner must provide the model number
of the product and nature of difculty being
experienced. This warranty does not obligate TPI Corporation to bear the cost of labor in replacing any assembly, unit or component part thereof, nor does the company assume any liability for secondary charges, expenses for installing or removal, freight or damages. There will be charges rendered for product repairs made after out warranty period has expired. Proof of purchase, including date, must accompany request for in-warranty service. In any event, TPI Corporation’s maximum liability shall not in any case exceed the list price for the product claimed to be defective. This warranty gives to you
specic legal rights and you may have other
rights, which may vary, from state to state. For the name of you nearest authorized TPI Corporation service center, please write to TPI Corporation, P.O. Box 4973, Johnson City, Tennessee, 37602.
All Other Heating Products 1 Year
Thermostats & Controls 2 Years
In addition to the Limited Warranty stated above covering general products, TPI Corporation extends this warranty on the following listed products, which are warranted to the original consumer from the original date of purchase for the total time periods indicated herein to the left:
Page 3
Electric Heat Comfort Zones
3
INSULATION
R-VALUE Recommended FHA Standard Minimum: Not Recommended
Ceiling *R-24 *R-19 *R-11
Walls R-13 11 R-7
Floor R-24 11 ----
ZONE APPROXIMATE WATTAGE NEED PER SQUARE FOOT
1 8.6 10.0 14.6
2 7.7 9.0 13.1
3 7.1 8.2 12.0
4 6.4 7.4 10.8
5 6.0 7.0 10.2
*”R”values are industry standards for insulation effectiveness. Ask company representative for assistance if you do not know “R” for your present structure insulation.
Baseboard or wall mount style? Recessed or surface type? It’s easy to select the heater that’s right for you.
1. Measure the size of the room(s) or area you intend to heat for square footage. You will need the length times the width to get this calculation.
2. Find your location on the map above. This determines your basic heating zone.
3. The chart shown below the map lists insulation values based on the effectiveness of the insulation presently in your home. Find your heating zone on the chart and the approximate wattage per square foot you will need.
4. Multiply the total number of square feet you intend to heat by the approximate wattage per square foot you just obtained. This will determine your total heating requirement in watts for the room.
How Much Heat is Right For You?
Figures are based on 15% total window and door openings in outside walls, and 3/4 total home air changes per hour. Typical frame-type construction with unheated basement or unventilated crawl space. If you do not have storm doors and windows, add 30% to the watts per square foot (multiply by 1.3).
That’s all there is to it! Now choose the heater with a wattage equal to what you need. Your nal selection will, of course,
depend on available wall space, window placement, ect.
Sample Calculation: Example = 10’ x 12’ room in Zone 3 with FHA standard insulation
1. Determine room square footage: 10’ x 12’ = 120 sq. ft.
2. Zone 3 with FHA standard insulation requires 8.2 watts per sq. ft.
3. Multiply square footage of room to be heated by the approximate wattage per square foot required.
120 sq. ft x 8.2 watts = 984 watts required. From this calculation it can be reasoned that a 1000 watt heater would be required.
Page 4
HLA Series Hazardous Location Fan Forced Unit Heater
FAN-FORCED SUSPENDED UNIT HEATERS 3-25 KW FOR T-3B CLASS I, GROUP C & D,
4
DIVISION 1 & 2 AND CLASS II, GROUPS E, F & G, DIVISIONS 1 & 2.
• Designed for rugged industrial applications in hazardous locations
where the possibility of explosion or re exists due to the presence of certain ammable gases, vapors, powdered metals or dust.
Permanently sealed, liquid to air, nned tube heat exchanger core.
Ethylene Glycol to water mixture used as a heat transfer uid in the heater core, providing -45° C. (-49° F) freeze damage protection.
High-performance electric motor driven fan blows air across nned tubes to effect uniform heat transfer and area heat distribution.
• Manual Reset capillary type limit provides high temperature regulation and is rated for 6,000 cycles of service.
Shown with optional pilot light and disconnect switch
• Stainless steel and aluminum pressure relief valve for overpressure.
• A back-up contactor is included for additional protection.
• 14 gauge steel cabinet powder coated epoxy paint nish contains heater
core, motor, and fan assembly.
• Narrow gap safety fan guard shields all moving parts.
• Adjustable louvers allow directional control of air.
Manufactured in U.S.A.
• Copper conductor wires enclosed in rigid metal conduits carry all electrical power.
• Box lugs furnished for eld connections within approved enclosure.
Product Specications
Heat Exchanger and Elements:
Heavy walled, painted carbon steel with aluminum ns liquid heat exchanger, liquid lled with three-immersion type copper
sheathed elements. The elements shall have the highest quality nickel-chromium resistance wire encased in a magnesium oxide
dielectric and be hermetically sealed into the heat exchanger core. The heat transfer uid is Ethylene-glycol solution for operation
to -49 degrees F (– 45 degrees C). Stainless steel and aluminum pressure relief valve for overpressure.
Thermal Cutout High Limit Protection and Optional Pilot Light:
The capillary type manual reset thermal cutout shall be rated for 6000 cycles of service and mounted in the liquid lled heat
exchanger. An optional pilot light to indicate manual reset tripped, if safe operating temperatures are exceeded, is located on control enclosure.
Motor: The motor shall be a permanent split capacitor type, permanently lubricated, ball bearing type. The motor shall be rated for hazardous location and operate at rated voltage of heater, 60 Hz, 1725 RPM.
Control Enclosure:
All controls shall be factory installed and wired in a hazardous location enclosure. Contactors and back-up contactors are heavy duty type and break all ungrounded conductors and be rated for 100,000 cycles at full load. Standard 24-Volt control circuit shall
be supplied by internal class II transformer. An optional factory wired integral thermostat or standard terminal block for eld
wiring to optional remote wall thermostat are wired in control panel. No fan delay relay.
Disconnect Switch:
Factory mounted and wired hazardous location disconnect switch is available as optional accessory.
Cabinet With Adjustable Louvers:
The Cabinet shall be 14 gauge, cold rolled steel with powder coated epoxy nish. Plated fan guards with less than 1/4 inch
spacing to cover motor and fan shall conform to OSHA Requirements.
Note:
Before selecting a hazardous location electric heater refer to Article 500 or other applicable standard referenced in the National Electric Code.
Liquid-to-air heat exchanger Optional built-in thermostat Hazardous Location Rated Motor
Page 5
HLA Series Hazardous Location Fan Forced Unit Heater
Rating Denitions
CLASS I: Equipment does not have surface operating temperature in excess of the ignition temperature of the specic gas or vapor.
Application Examples:
Offshore and land based drilling rigs, petroleum exploration and testing facilities.
Petroleum reneries, gasoline storage and dispensing areas.
Industrial rms that use ammable liquids in dip tanks for parts cleaning or other operations.
Petrochemical companies that manufacture chemicals from gas or oil.
Dry cleaning facilities where vapors from cleaning uids may be present.
Aircraft hangers and fuel servicing areas.
Utility gas plants and operations involving storage and handling of liqueed petroleum or natural gas.
GROUP C: Atmospheres such as but not limited to acetaldehyde, allyl alcohol, hydrogen sulde, ethylene, carbon monoxide, or
other gases or vapors of equivalent hazard.
GROUP D: Atmospheres such as but not limited to acetone, alcohol, gasoline, lacquer solvent vapors, natural gas, propane or other gases or vapors of equivalent hazard.
CLASS II: Equipment does not have surface temperature greater than the ignition temperature of the specied dust.
Application Examples:
Coal preparation plants and other carbon handling or processing areas.
Grain elevators, our and feed mills.
Plants which manufacture, use or store Magnesium or Aluminum powders.
Plants that have chemical or metallurgical processes.
Producers of starch products or candy.
Spice grinding plants, sugar plants and cocoa plants.
GROUP E: Atmosphere containing combustible metal dust regardless of resistivity, or other combustible dust of similar hazard characteristics having resistivity of less than 105 OHM - Centimeter.
GROUP F: Atmosphere containing carbon black, charcoal, coal or coke dust.
GROUP G: Atmospheres containing combustible dust having resistivity of 105 OHM-Centimeter or greater.
DIVISION I: A location in which ignitable concentrations of ammable material exist under normal operating conditions.
DIVISION II: Locations in which ammable materials will normally be conned within closed containers and escape only in the
case of accidental rupture, breakdown or during maintenance operations. Any equipment approved for Division I is automatically also approved for Division II.
5
Standard Hazardous Location Models
UPC#
686334
734356 HLA 12-208160-3.0-24 734004 HLA 12-208360-3.0-24 208 3 9.8 734011 HLA 12-240160-3.0-24 240 1 14.8 734028 HLA 12-240360-3.0-24 240 3 8.6 734035 HLA 12-480360-3.0-24 480 3 4.3 734363 HLA 12-208160-5.0-24 734059 HLA 12-208360-5.0-24 208 3 15.4 734066 HLA 12-240160-5.0-24 240 1 23.1 734073 HLA 12-240360-5.0-24 240 3 13.4 734080 HLA 12-480360-5.0-24 480 3 6.7 734370 HLA 12-208160-7.5-24 734103 HLA 12-208360-7.5-24 208 3 22.3 734110 HLA 12-240160-7.5-24 240 1 33.6 734127 HLA 12-240360-7.5-24 240 3 19.4 734134 HLA 12-480360-7.5-24 480 3 9.7 734158 HLA 16-208360-10.0-24 734165 HLA 16-240160-10.0-24 240 1 44 734172 HLA 16-240360-10.0-24 240 3 25.5 734189 HLA 16-480360-10.0-24 480 3 12.7 734202 HLA 20-208360-15.0-24 734219 HLA 20-240360-15.0-24 240 3 38.1 734226 HLA 20-480360-15.0-24 480 3 19 734233 HLA 20-600360-15.0-24 600 3 15.2 734240 HLA 20-480360-20.0-24 734257 HLA 20-600360-20.0-24 600 3 20 734264 HLA 20-480360-25.0-24 734271 HLA 20-600360-25.0-24 600 3 24.9
Note: Products listed in this section are custom built and subject to 100% cancellation/restock charges.
MODEL KW BTU’s VOLTS PH AMPS
208 1 16.3
3 10250
208 1 26
5 17100
208 1 38
7.5 25600
208 3 29.3
10 34150
208 3 43.5
15 51200
20 68300
25 85400
480 3 25.1
480 3 31.1
Control Voltage
Temp
Rise °F
24
Air
Throw
16.5
27.6 8’ 167 lb. 9378
41.4 8’ 167 lb. 9749
21.7 40’ 1500 10’ 193 lb. 10313
19.2
26.2
32.8 12168
CFM
24’ 580
43’ 2450 13’
Recom’d
Mounting Ht.
8’ 167 lb. 8999
193 lb. 10760
225 lb.
WT. LIST
11176
Page 6
HLA Series Hazardous Location Fan Forced Unit Heater
Mounting Bracket Kits
6
Column stabilizing components
Mounting arm assembly
Attachment assembly
1/2” Pipe (Not Supplied)
Roof or overhead structure
3 1/2” Schedule 40 (Pipe) (Not Supplied)
Base assembly
HLPM Pipe Mounting Kit
Particularly useful in buildings with
insufcient strength to use other types of
mounts. Requires 3 1/2’’ pipe (4’’ O.D. ­not supplied).
HLHM Hanging Mounting Kit
Simple and economical if adequate overhead structure exists. Requires 1/2’’ pipe, cut and threaded (not supplied).
Wall bracket
Mounting arm Attachment assembly
Wall or structure
HLWM Wall Mounting Kit
Ideal for use in buildings that have substantial walls. Arm only can also be bolted directly to structural steel.
UPC#
686334
734288 HLPM37 3.0 kW - 7.5 kW 37
734301 HLPM1525 15.0 kW - 25.0 kW 40 734318 HLHM ALL 5 191 734325 HLWM37 3.0 kW - 7.5 kW 27
734349 HLWM1525 15.0 kW - 25.0 kW 29
MODEL USE WITH HEATERS
WT.
(LBS.)
LIST
479734295 HLPM10 10.0 kW 38
399734332 HLWM10 10.0 kW 28
EPET Series and HLT Series Hazardous Location Thermostats For Single Phase
HLT Series
Features
• SPDT & DPDT Models
• Heat or cool compatible
• Celsius and Fahrenheit temperature scale
• Bi-Metal or capillary sensor
• Snap action switch
• Casting tapped top and bottom for 3/4” conduit
• 1/2” thick cast aluminum housing
• Dimension 5.75” x 6.375” x 5.57”
Motor Rating (full load): 3/4 HP @ 125V, 1 1/2 HP @250V Pilot Duty Rating 125VA @ 24VAC NEMA Class Seven Div. 1 Approved Class I Group C & D, Class II Group E, F, & G Not rated for Group B
UPC#
686334
538077 EPETD8D DPDT - Bi-Metal 22A @120-277VAC 50-90oF
538107 EPETD8S SPDT - Bi-Metal 22A @120-277VAC 50-90oF
528078 EPETP8D DPDT - Bi-Metal 22A @120-480VAC 50-90oF
528061 EPETP8S SPDT - Bi-Metal 22A @120-480VAC 50-90oF
523158 H LT-1 SPDT - Capillary 22A @120-277VAC 40-110oF
523165 H LT-2 DPDT - Capillary 22A @120-277VAC 40-110oF
HLT Series incorporates screwdriver temperature adjustment slot and all metal housing. External bulb
MODEL DESCRIPTION LOAD RATINGS RANGE LIST
337
476
502
Master ctn: 4 pcs, 24 llbs (varies slightly by model), 16” x 14.5” x 6”
EPET Series incorporate plastic knob & Bi-Metal Sensor housing.
and capillary sensor.
Page 7
HLA Series Hazardous Location Fan Forced Unit Heater
Factory Installed Accessories & Physical Dimensions
(Top View)
SUFFIX DESCRIPTION
T In-Built single pole thermostat 50° - 90° F 318
120 Control transformer w/ primary fusing (Delete 24 sufx - add 120) 228
208
240
D Disconnect Switch 1574
P Pilot Light 882
MODEL A B
HLA 12 17 3/4 22 3/8 19 3/4 20 5/8 16 1/4 10 1/2 14 3
HLA 16 20 3/4 26 3/8 20 3/4 21 5/8 20 1/4 11 1/2 18 4
HLA 20 24 3/4 30 3/8 22 1/2 N/A 24 1/4 12 1/2 22 4 1/2
208/240V Control available on 208/240V units
(Delete 24 sufx and add 208 OR 240)
C
3 ph. 1 ph.
D E F G
(Rear View)
LIST
ADDER
Subtract
63
(Front View)
(Side View)
PHLA Series Portable Hazardous Location Fan Forced Unit Heater
• 3.0 through 25 KW rating
• 208, 240, 480, 600 Volt available in selected capacities
• Cart has anti-static wheels to reduce the risk of static discharge
• Wheeled cart allows for easy maneuverability
• Cart has integrated fork-lift channels to provide ease of lifting on to ramps or trucks
• Excellent for providing seasonal heating in hazardous environments
• All units have disconnect switch, pilot light, and thermostat - standard
• 24 Volt control, transformer, and contactor in NEMA 7 enclosure
• Durable epoxy coating on heater housing
• Hazardous location unit mounted male / female plug
• Adjustable louvers; manual reset
Standard Portable Hazardous Location Models
7
UPC # 686334 739344 PHLA12-208160-3.0-24-TDP 739337 PHLA12-208360-3.0-24-TDP 208 3 9.8 739320 PHLA12-240160-3.0-24-TDP 240 1 14.8 739313 PHLA12-240360-3.0-24-TDP 240 3 8.6 739306 PHLA12-480360-3.0-24-TDP 480 3 4.3 739436 PHLA12-600360-3.0-24-TDP 600 3 3.5 739290 PHLA12-208160-5.0-24-TDP 739283 PHLA12-208360-5.0-24-TDP 208 3 15.4 739276 PHLA12-240160-5.0-24-TDP 240 1 23.1 739269 PHLA12-240360-5.0-24-TDP 240 3 13.4 739252 PHLA12-480360-5.0-24-TDP 480 3 6.7 739429 PHLA12-600360-5.0-24-TDP 600 3 5.4 739245 PHLA12-208160-7.5-24-TDP 739238 PHLA12-208360-7.5-24-TDP 208 3 22.3 739221 PHLA12-240160-7.5-24-TDP 240 1 33.6 739214 PHLA12-240360-7.5-24-TDP 240 3 19.4 739207 PHLA12-480360-7.5-24-TDP 480 3 9.7 739412 PHLA12-600360-7.5-24-TDP 600 3 7.8 739191 PHLA16-208360-10.0-24-TDP 739184 PHLA16-240160-10.0-24-TDP 240 1 44 739177 PHLA16-240360-10.0-24-TDP 240 3 25.5 739160 PHLA16-480360-10.0-24-TDP 480 3 12.7 739405 PHLA16-600360-10.0-24-TDP 600 3 10.2 739153 PHLA20-208360-15.0-24-TDP 739146 PHLA20-240360-15.0-24-TDP 240 3 38.1 739139 PHLA20-480360-15.0-24-TDP 480 3 19 739399 PHLA20-600360-15.0-24-TDP 600 3 15.2 739122 PHLA20-480360-20.0-24-TDP 739382 PHLA20-600360-20.0-24-TDP 600 3 20
739115 PHLA20-480360-25.0-24-TDP
739375 PHLA20-600360-25.0-24-TDP 600 3 24.9
Note: Products listed in this section are custom built and subject to 100% cancellation/restock charges.
MODEL KW BTU VOLTS PH AMPS
208 1 16.3
3 10,250
208 1 26
5 17,100
208 1 38
7.5 25,600
208 3 29.3
10 34,150
208 3 43.5
15 51,200
20 68,300
25 85,400
480 3 25.1
480 3 31.1
TEMP
RISE F
16.5 24’ 580 260 19,950
27.6 24’ 580 260 20,300
41.4 24’ 580 260 20,700
21.7 40’ 1500 305 22,400
19.2 43’ 2450 350 24,140
26.2 43’ 2450 350 24,600
32.8 43’ 2450 350 25,400
AIR
THROW
CFM WT LIST
Page 8
FEP Series Single Phase Hazardous Location Wall Convector
8
Standard Unit
Unit with optional control section containing disconnect, pilot light, and thermostat
(Sufx C1-TDP)
Unit with in-built EPET line voltage thermostat
(Sufx T1 or T2)
Manufactured in U.S.A.
• Cabinet size 18” high, 9” wide.
• Bottom In - Front Out air ow.
• Wall mounting bracket supplied.
• Units cannot be operated in room ambients exceeding 104OF (40OC).
• Heavy duty 16 gauge steel with gray
epoxy textured powder coated nish.
• 9” minimum clearance from bottom of
heater to oor required.
• Stainless steel cartridge element inserted
into Aluminum nned Copper sheath.
• Standard unit (without EPET thermostat or control section) is NEMA 4 rated.
Class 1, Group B, C & D Division 1 & 2 280° C / 536° F
UPC
686334 LENGTH
445146 FEP-1812-1RA
445153 FEP-1820-1RA 208 8.7
445160 FEP-1824-1RA 240 7.5
445177 FEP-1827-1RA 277 6.5
445184 FEP-1848-1RA 480 3.8
445191 FEP-3620-1RA
445207 FEP-3624-1RA 240 15.0
445214 FEP-3627-1RA 277 13.0
445221 FEP-3648-1RA 480 7.5
445238 FEP-3657-1RA 600 6.0
445245 FEP-3820-1RA
445252 FEP-3824-1RA 240 15.8
445269 FEP-38271-RA 277 13.7
445276 FEP-3848-1RA 480 7.9
445283* FEP-7620-1RA
445290* FEP-7624-1RA 240 31.7
445306* FEP-7627-1RA 277 27.4
445313 FEP-7648-1RA 480 15.8
445320 FEP-7657-1RA 600 12.7
MODEL WATTS BTU's VOLTS AMPS
T-2A SERIES SINGLE PHASE
CABINET
120 15.0
1800 6143
208 17.3
3600 12286
208 18.3
3800 12969
208 36.5
7600 25938
*Items may not be used with 22 Amp line voltage thermostat
Class 1, Group B, C & D Division 1 & 2 180° C / 356° F
445337 FEP-0812-1RA
445344 FEP-0820-1RA 208 3.8
445351 FEP-0824-1RA 240 3.3
445368 FEP-0827-1RA 277 2.9
445375 FEP-0848-1RA 480 1.7
445382 FEP-1612-1RA
445399 FEP-1620-1RA 208 7.7
445405 FEP-1624-1RA 240 6.7
445412 FEP-1627-1RA 277 5.8
445429 FEP-1648-1RA 480 3.3
445436 FEP-1657-1RA 600 2.7
445443 FEP-1712-1RA
445450 FEP-1720-1RA 208 8.2
445467 FEP-1724-1RA 240 7.1
445474 FEP-1727-1RA 277 6.1
445481 FEP-1748-1RA 480 3.5
445498 FEP-3420-1RA
445504 FEP-3424-1RA 240 14.2
445511 FEP-3427-1RA 277 12.3
445528 FEP-3448-1RA 480 7.1
445535 FEP-3457-1RA 600 5.7
T-3A SERIES SINGLE PHASE
120 6.7
800 2730
120 13.3
1600 5460
120 14.2
1700 5802
208 16.3
3400 11604
WT.
(LBS.)
34” 50 1493
34” 54 2278
58” 80 2416
58” 85 2811
34” 50 1493
34” 54 2278
58” 80 2416
58” 85 2811
LIST
Factory Installed Control Options
SUFFIX* DESCRIPTION LIST SUFFIX** DESCRIPTION LIST
T1
T2
*Remove - RA sufx and add new sufx. **Remove - RA sufx and add new sufx (Not NEMA washdown rated or rated for Group B atmospheres) Sufx “T” is 22 Amps maximum.
Note: Products listed in this section are custom built and subject to 100% cancellation/restock charges.
EPETD8S single pole thermostat factory
mounted to 120V - 480V units
EPETD8D double pole thermostat factory
mounted to 120V - 480V units
578 C1-TD
599 C1-TDP
Control section with transformer, 24V contactor, SP thermostat
(40OF - 90OF) and disconnect switch (all units)
Control section with transformer, 24V contactor, SP thermostat
(40OF - 90OF), disconnect switch & pilot light (all units)
1986
2063
Page 9
FEP Series Three Phase Hazardous Location Wall Convector
• Cabinet size 18” high, 9” wide.
• ABS (American Bureau of Shipping) type approved.
• Bottom In - Top Out air ow.
• Wall mounting bracket supplied.
• Units can not be operated in room ambients exceeding 104OF (40OC).
• Heavy duty 16 gauge steel with gray epoxy textured powder coated nish.
• 9” minimum clearance from bottom of heater to oor required.
• Stainless steel cartridge element inserted into Aluminum nned Copper sheath.
• Standard unit (without EPET thermostat or control section) is NEMA 4 rated.
UPC
686334 LENGTH
483056 FEP-1820-3RA 483063 FEP-1824-3RA 240 4.3 486224 FEP-1848-3RA 480 2.2 1869 483070 FEP-3620-3RA 483087 FEP-3624-3RA 240 8.7 486231 FEP-3648-3RA 480 4.3 2726 483094 FEP-3820-3RA 483100 FEP-3824-3RA 240 9.1 486248 FEP3848-3RA 480 4.6 2999 483117 FEP-7620-3RA
486255 FEP-7648-3RA 480 9.2
483131 FEP-0820-3RA
483148 FEP-0824-3RA 240 1.9
486262 FEP-0848-3RA 480 0.9 1869
483155 FEP-1620-3RA
483162 FEP-1624-3RA 240 3.8
486279 FEP-1648-3RA 480 1.9 2726
483179 FEP-1720-3RA
483186 FEP-1724-3RA 240 4.1
486286 FEP-1748-3RA 480 2.0 2999
483193 FEP-3420-3RA
486293 FEP-3448-3RA 480 4.1
Class 1, Group B, C, & D Divisions 1 & 2 280° C / 536° F
MODEL WATTS BTU's VOLTS AMPS
Class 1, Group B, C & D Division 1 & 2 180° C / 356° F
T-2A SERIES THREE PHASE
208 5.0
1800 6143
208 10.0
3600 12286
208 10.5
3800 12969
208 21.1
7600 25938
T-3A SERIES THREE PHASE
208 2.2
800 2730
208 4.4
1600 5460
208 4.7
1700 5802
208 9.4
3400 11604
CABINET
34” 50
34” 54
58” 80
58” 85 3223483124 FEP-7624-3RA 240 18.3
34” 50
34” 54
58” 80
58” 85 3192483209 FEP-3424-3RA 240 8.2
WT.
(LBS.)
LIST
1719
2622
2784
1719
2622
2784
Standard Unit
Unit with optional control section containing disconnect, pilot light, and thermostat
(Sufx C1-TDP)
Note: Controls mounted on the left side only.
*T1 and T2 option not available on 3 phase models
Factory Installed Control Options
SUFFIX** DESCRIPTION
C1-TD Control section with transformer, 24V contactor, SP thermostat (40OF - 90OF) and disconnect switch (all units) 1971
C1-TDP
Control section with transformer, 24V contactor, SP thermostat (40OF - 90OF), disconnect switch & pilot light (all units)
Note: C1-TD and C1-TDP are only options available for 3 phase units.
Remote Mounted Hazardous Location Thermostats For Single Phase Models Only
**Remove - RA sufx and
LIST
add new sufx (Not NEMA
washdown rated or rated for
2047
Group B atmospheres)
9
HLT Series
HLT Series
EPET Series Parameters
Dimensions: Height 5 5/8’’, Width 6 3/8’’, Depth 4 1/2’’ Finish: Silver-Gray
UPC#
686334
538077 EPETD8D DPDT - Bi-Metal 22A @120-277VAC 50-90oF
538107 EPETD8S SPDT - Bi-Metal 22A @120-277VAC 50-90oF
528078 EPETP8D DPDT - Bi-Metal 22A @120-480VAC 50-90oF
528061 EPETP8S SPDT - Bi-Metal 22A @120-480VAC 50-90oF
523158 HLT-1 SPDT - Capillary 22A @120-277VAC 40-110oF 476
523165 HLT-2 DPDT - Capillary 22A @120-277VAC 40-110oF 502
HLT Series incorporates screwdriver temperature adjustment slot and all metal housing. External bulb and capillary sensor.
MODEL DESCRIPTION LOAD RATINGS RANGE LIST
Master ctn: 4 pcs, 24 lbs (varies slightly by model), 16” x 14.5” x 6”
EPET Series incorporates plastic knob & Bi-Metal Sensor housing.
Motor Rating: (full load) 1 1/2 HP @ 250V Rating: 22A @ 125-277VAC; 125VA @ 24VAC Rated: Class I Group C & D, Class II Group E, F, G Thermostat is not rated for use in Group B environments.
Type: Single or Double Pole
Note: Products listed in this section are custom built and subject to 100% cancellation/restock charges.
337
Page 10
10
FIG. 2
5500 Series Washdown Fan Forced Unit Heater
Rear View
Manufactured in U.S.A.
• Heavy-duty 304 16 gauge stainless steel shroud.
• 316 stainless construction available.
• Nema 4x non-metallic control panel.
• 24-Volt transformer and control panel.
• 3-position switch (off-heat-fan).
• Capillary thermostat with stainless steel sensor.
• Automatic reset thermal cutout.
• Totally enclosed U.L. listed motor.
• Pilot light (power on indicator).
Control Panel
Mounting Bracket Kits & Product Dimensions
The Washdown Series unit heaters are electric unit heaters constructed for use in areas that require washing or hosing of equipment due to dirty or dusty industrial environments in non-hazardous locations. The totally enclosed water-tight construction made with corrosion-resistant material make this series ideal for industrial heating applications. The Washdown Series is constructed with all built-in controls and safety temperature controls wired in a non-metallic Nema 4x control panel with single-point power connections.
Stainless steel nned tubular element. Constructed of 304 or 316 stainless rod and ns.
• Control panel on bottom of unit for ease of installation and service.
• Disconnect switch with enclosure door interlock.
• Front grill rotates to direct airow.
• Single-point power connection.
• Fan Blade Epoxy coated Aluminum.
• Epoxy painted cold roll steel model available, consult factory
• Meets all U.L., NEC, and OSHA requirements (when installed as directed).
• Corrosion-resistant in high humidity and water-saturated areas (for areas where corrosion resistance is needed in non-explosive areas, contact factory for heater applications and optional materials).
•ABS (American Bureau of Shipping) type approved.
• Thermostat temp range: 40o-100oF
SIZEKWUPC#
686334
3.3-15 713672 A5520/UHB 293 713726 W5520/WMK
20-48 ---- - 713733 W5550/WMK 713719 H5550/HMK 713696 P5550/PMK
* Material: Heavy Duty Epoxy Powder Coat Finish.
3-15 Kw ONLY
H
STAINLESS STEEL
COMBINATION BRACKET
Ideal for use in buildings that have substantial walls. Arm (only) can be bolted directly to structural steel.
A5520
G
FIG. 1
LIST
WALL BRACKET
MOUNTING ARM
WALL OR STRUCTURE
W5550
UPC#
686334
WALL MTG. BRACKET *
Simple and economical if adequate overhead structure exists. Requires 1/2" pipe, cut and threaded (not supplied).
ROOF OR OVERHEAD STRUCTURE
1/2" PIPE (NOT SUPPLIED)
H5550
A
E
C
UPC#
LIST
686334
713702 H5520/HMK
417
Particularly useful in buildings with insufficient strenth to use other types of mounts. Requires 3 1/2" pipe (4" O.D.-not supplied).
HANGING
BRACKET *
3 1/2" SCHEDULE 40 PIPE (NOT SUPPLIED)
LIST
293
P5550
UPC#
686334
713689 P5520/PMK
COLUMN STABILIZING COMPONENETS
PIPE MTG.
BRACKET *
MOUNTING ARM ASSY.
BASE ASSEMBLY
LIST
417
D
B
FIG. 3
F
Heater
KW
3-7.5 12.00 18.00 19.75 15.25 16.25
10-15 14.00 19.00 21.75 15.25 18.00 8.00 6.00
20-30 16.00 27.00 28.75 19.50 17.50 15.50 4.50
40-48 18.00 31.00 30.75 19.50 19.50 21.75 2.75
Heater Dimension in Inches unless otherwise stated.
A B C D E F G H
8.00 6.00
6 ft.
Page 11
5500 Series Washdown Fan Forced Unit Heater
Enclosure and Motor:
Element housing shall be 16 gauge 304 or 316 stainless steel shroud. The outlet grill and louver assembly shall be 304/316 stainless steel and rotate for direction of discharge air. The heater shall have a 304/316 stainless steel inlet grill and fan guard. The motor shall be totally enclosed, permanently lubricated and designed to resist moisture and corrosion. The fan blade shall be aluminum with a
powder coated epoxy nish.
Element: The heating element shall be 304 or 316 stainless steel tube with
304/316 stainless steel n
material helically attached to the tube for even heat transfer. The element designed with the highest quality nickel­chromium resistance wire embedded in compacted
efcient dielectric to ensure
proper heat transfer.
Control Panel: The control enclosure shall be non-metallic Nema 4X control panel water­tight and dust- tight. The enclosure and elements are attached to the control panel with stainless steel fasteners. Standard control components are factory mounted and wired with access through control panel door on bottom of heater assembly. A standard door interlock disconnect switch shall be factory mounted and wired for safety.
Controls: All controls shall be factory mounted and wired in Nema 4X panel. Terminal block, 24 Volt transformer, high temperature limits, contactor and fusing if required by NEC are mounted and wired in control panel. A three-position switch (Off­Heat-Fan) shall be mounted on side of control panel for access from outside of panel. A pilot light to indicate power is on for safety shall be located on side of control panel. A wall mounted Nema 4X thermostat is an optional accessory.
Mounting Bracket: A formed 304/316 stainless steel bracket shall be used on 3.3 thru 15 KW units. A cast iron epoxy painted bracket shall be used on 20 thru 48 KW units. Above brackets shall be combination wall/ceiling type. Optional mounting brackets are available.
Note: For 60Amp disconnect add $50.00 Net. Add ‘D’ as the sufx; For optional monel elements, add 40% to
the net of the heater. For powder coat epoxy painting of shroud, add $210 list to heater pricing. For 316 stain­less add 20% to net price of the heater.
Note: Products listed in this section are custom built and subject to 100% cancellation/restock charges.
Product Specications & Standard Washdown Models
UPC#
686334
713047 F1F5503T
713054 F3F5503T 208 3 9.2
713061 H1H5503T 240 1 13.7
713078 H3H5503T 240 3 7.9
713085 G1G5503T 277 1 11.9
713092 P3P5503T 480 3 4
713115 F1F5505T
713122 F3F5505T 208 3 13.9
713139 H1H5505T 240 1 20.8
713146 H3H5505T 240 3 12.1
713153 G1G5505T 277 1 18.1
713160 P3P5505T 480 3 6.1
713184 F1F5507T
713191 F3F5507T 208 3 20.8
713207 H1H5507T 240 1 31.3
713214 H3H5507T 240 3 13.1
713221 G1G5507T 277 1 27.1
713238 P3P5507T 480 3 9.1
713252 F1F5510T
713269 F3F5510T 208 3 27.7
713276 H1H5510T 240 1 41.2
713283 H3H5510T 240 3 24.1
713290 G1G5510T 277 1 36.1
713306 P3P5510T 480 3 12.1
713399 F1F5515T
713405 F3F5515T 208 3 41.7
713412 H1H5515T 240 1 62.5
713429 H3H5515T 240 3 36.1
713443 P3P5515T 480 3 18.1
713467 F3F5520T
713481 P3P5520T 480 3 24.1
713504 F3F5525T
713528 P3P5525T 480 3 30.1
713542 F3F5530T
713566 P3P5530T 480 3 36.1
713603 P3P5540T 40 136520 480 3 48.2 70
713641 P3P5548T 48 163824 480 3 57.8 84 10484
MODEL KW BTU’s VOLTS PH AMPS
208 1 15.9
3.3 11200
208 1 24.1
5 17100
208 1 36.1
7.5 25600
208 1 47.8
10 34130
208 1 72.1
15 51200
208 3 55.6
20 68260
208 3 69.5
25 85325
208 3 83.4
30 102390
CONTROL
VOLTAGE
24
TEMP
RISE °F
26
40 4103
60 4673
45
68 6448
45
56 7407713511 H3H5525T 240 3 60.2
68 8087713559 H3H5530T 240 3 72.3
AIR
THROW
CFM
20’ 400 58
28’ 700 64
35’ 1400 92
42’ 1800 126
WT.
(lbs.)
LIST
3953
5623
7407713474 H3H5520T 240 3 48.2
8431
Remote Rain-Tight Thermostat
UPC#
686334
523424 TW155A 1 POLE, 40-110 deg F, 22Amp 179
523431 TW255A 2 POLE, 40-110 deg F, 22Amp 209
Note: NEMA 4X Construction Stainless Steel Hardware
MODEL DESCRIPTION LIST
11
Page 12
12
HOW TO DESIGNATE A MODEL:
UH Series Horizontal Fan Forced Unit Heater
3.3 KW THROUGH 48 KW HORIZONTAL DISCHARGE SUSPENDED FAN FORCED UNIT HEATERS AVAILABLE IN 1 OR 3 PHASE FOR ALL STANDARD VOLTAGES FROM 208V TO 480V.
CONSTRUCTION:
Heavy gauge welded steel cabinet with powder coated nish and control
compartment with a hinged and latched access door, simplifying wiring installation & maintenance.
HEATING ELEMENT:
Circular copper clad steel sheath element with continuously brazed steel ns
formed to match the air delivery pattern of the fan blade. OVERHEAT PROTECTION:
All units come equipped with automatic resetting type limit controls to de­energize the heater should an over-temperature situation occur.
FAN and MOTOR: Totally enclosed, single phase, permanently lubricated, thermally protected
Manufactured in U.S.A.
NOTE: Louver assembly is square and mounted with screws. Louver can be removed and repositioned for four
(4) directional air ow - left - right - up - down with the
heater in the horizontal position.
FACTORY INSTALLED OPTIONS:
• 24 Volt transformer on 3 KW to 15KW units to convert from line voltage to low voltage remote thermostat operation.
• Summer fan switch to operate the fan only.
• Fan delay switch to purge all residual heat from the unit after the heating element has cycled off.
• Powder coated epoxy nish for corrosive atmospheres.
• Disconnect switch.
MAXIMUM RECOMMENDED MOUNTING
HEIGHT
3 - 10 KW 9 FT. 12 - 15 KW 10 FT. 20 - 30 KW 13 FT. 40 - 48 KW 16 FT.
Product Dimensions & Model Number Designation
motors with unit bearings on 3 KW - 10 KW models and sleeve bearings on 12.5 KW - 48 KW models - mounted with rubber insulators to minimize vibration and noise. Fan assembly enclosed by a heavy gauge, close spaced, chrome plated wire guard.
LOUVER ASSEMBLY:
Louvers are individually adjustable for directional control of air ow and the entire assembly can be repositioned in the eld from down ow to up ow or left / right directional air ow.
TEMPERATURE CONTROLS: 20 KW through 48 KW units and all 480V have built in 24 Volt transformer for low voltage remote thermostat application. 25 KW through 48 KW models available in 2-stage on special order (consult factory). INSTALLATION: Unit Heaters can be mounted with the motor shaft from horizontal to downward at 45° off horizontal. Pre-drilled holes and installed threaded nuts provided to allow hanging by threaded rods - 1/4” for units up to 15 KW and 5/16” for 20 KW units and larger. Optional wall / ceiling mounting brackets are available for all units.
B
3.3 KW THROUGH 15 KW UNIT HEATERS 20 KW THROUGH 48 KW UNIT HEATERS
Figures 3 & 4 shown with standard mounting tabs for units over 20 KW. Optional UHB-3 and UHB-4 wall brackets are available. 3.3 KW
thru 15 KW units can be mounted using 1/4” threaded rod. 20 KW thru 48 KW units can be mounted using 5/16” threaded rod.
Element Volts F = 208 H = 240 HF = 240/208 G = 277 P = 480
Factory Installed Options (use as a suffix on model designation): S = Summer Fan Switch, F = Fan Delay, D = Disconnect, T = Built-in Thermostat, E = Epoxy Coated
Field Installed Options: Disconnect Switch, Built-in Thermostat, & Wall / Ceiling Bracket
A
Phase 1 = 1-Phase 2 = 1 or 3-Ph. 3 = 3-Phase
A
B
B
A
H 2 H UH 10 C A 1
Motor Voltage F = 208 H = 240 B = 240 / 208 G = 277 P = 480
Model Series UH
Element KW
Control System O = None C = Contactor R = Relay
Dimensions A B C
Figure 1:
3.3, 5, 7.5, 10 KW
Figure 2:
12.5, 15 KW
Figure 3:
20, 25, 30 KW
Figure 4:
40, 48 KW
Transformer O = None A = Included
20” 11” 13”
22” 11” 15”
24” 17” 17”
26” 23” 19”
Control Volts 1 = 24 2 = 120 3 = Element Voltage 4 = 240
Page 13
UH Series Horizontal Fan Forced Unit Heater
Standard Product Models
UPC#
686334 644600 F1FUH03003 644662 H1HUH03003 240 1 13.8 240 644723 G1GUH03003 277 1 11.9 277 711487 H3HUH03C03 240 3 7.9 240 711494 F3FUH03C03 208 3 9.2 208 711401 P3PUH03CA1 480 3 4 24 883 644617 F1FUH05003 644679 H1HUH05003 240 1 20.8 240 644730 G1GUH05003 277 1 18.1 277 644938 F2FUH05C03 208 1 or 3 24.1 / 14.0 208
644884 P3PUH05CA1 480 3 6.1 24 958 718059 F1FUH07CA1 717373 H1HUH07CA1 240 1 31.3 24 41 715188 G1GUH07CA1 277 1 27.1 24 41 644792 F3FUH07C03 208 3 20.8 208 644952 H2HUH07C03 240 1 or 3 31.3 / 18.1 240 644891 P3PUH07CA1 480 3 9.1 24 1204 717090 F1FUH10CA1 680844 H1HUH10CA1 240 1 41.7 24 717380 G1GUH10CA1 277 1 36.1 24 644969 F2FUH10C03 208 1 or 3 48.1 / 27.8 208
644976 HF2BUH10C03 10 / 7.5
711425 P3PUH10CA1 10.0 34100 480 3 12.1 24 55 51 1275 644648 F1FUH12C03 644709 H1HUH12C03 240 1 52.1 240 644815 F3FUH12C03 208 3 34.7 208 644860 H3HUH12C03 240 3 30.1 240 711432 P3PUH12CA1 480 3 15.1 24 2060 644655 F1FUH15CO3 644716 H1HUH15C03 240 1 62.5 240 644822 F3FUH15C03 208 3 41.7 208 644877 H3HUH15C03 240 3 36.1 240 711449 P3PUH15CA1 480 3 18.1 24 2266 688307 F1FUH20CA1 688420 H1HUH20CA1 240 1 83.3 24 688314 F3FUH20CA1 208 3 55.6 24 688437 H3HUH20CA1 240 3 48.2 24 688321 P3PUH20CA1 480 3 24.1 24 688444 F1FUH25CA1 688338 H1HUH25CA1 240 1 104.2 24 688451 F3FUH25CA1 208 3 69.5 24 688345 H3HUH25CA1 240 3 60.2 24 688468 P3PUH25CA1 480 3 30.1 24 688475 H1HUH30CA1 688369 F3FUH30CA1 208 3 83.4 24 688482 H3HUH30CA1 240 3 72.3 24 688376 P3PUH30CA1 480 3 36.1 24 688406 P3PUH40CA1 40.0 136500 480 3 48.2 24 55 56’ 2275 16’ 75 5216 688789 P3PUH48CA1 48.0 163800 480 3 57.8 24 67 56’ 2275 16’ 78 6512
MODEL KW BTU’S VOLTS PH AMPS
208 1 15.9 208
3.3 11200
208 1 24.1 208
5 17100
208 1 36.1 24
7.5 25600
208 1 48.1 24
10.0 34100
34100 240 1 or 3 41.7 / 24.1 240 55 25600 208 1 or 3 36.1 / 20.8 208 42
208 1 60.1 208
12.5 42600
208 1 72.1 208
15.0 51200
208 1 96.2 24
20.0 68300
208 1 120.2 24
25.0 85300
240 1 125 24
30.0 102390
CONTROL
VOLTS
TEMP
RISE °F
26 26’ 400 9’ 36
40 26’ 400 9’
42 36’ 575 9’
55
49 45’ 800 10’ 45
59 45’ 800 10’ 54
47 56’ 1350 13’ 55 2991
58 56’ 1350 13’ 55 3525
70 56’ 1350 13’ 60 4081
AIR
THROW
CFM
MOUNTING HT.
36’ 575 9’
RECOM’D
WT.
(LBS.)
36
44644945 H2HUH05C03 240 1 or 3 20.8 / 12.1 240
40
44
42
45
LIST
693
724
1116
1230
1980
2179
13
Factory & Field Installed Accessories
SUFFIX DESCRIPTION
F
S Summer fan switch 58
CA1 24v Transformer (3.3 KW - 15 KW units) & Contactor CA2 120v Transformer (3.3 KW - 15 KW units) & Contactor
E Epoxy Coating 111 T SPST Thermostat 67
D
FACTORY INSTALLED OPTIONS
Heat purge fan delay switch for 208 / 240 / 277V units
(includes contactor & transformer)
Heat purge fan delay switch for 480V units
(contactor & transformer standard in unit)
Disconnect Switch - 30 Amps 281
Disconnect Switch - 40 Amps 322
Disconnect Switch - 80 Amps 405
Disconnect Switch - 100 Amps 411
LIST
201
117
147
FIELD INSTALLED ACCESSORIES
UPC
686334
646239 DCS303 30 Amp Disconnect Kit 240
646246 DCS403 40 Amp Disconnect Kit 282
646253 DCS803 80 Amp Disconnect Kit 370
646260 DCS1003 100 Amp Disconnect Kit
687997 TUH1 25 Amp SPST Thermostat Kit 67
699105 UHB-1 wall / ceiling bracket - 3.3 KW - 15 KW units 99
699112 UHB-3 wall / ceiling bracket - 20 KW - 30 KW units 112
699129 UHB-4 wall / ceiling bracket - 35 KW - 48 KW units 142
MODEL DESCRIPTION LIST
NOTE: Factory installed heat purge fan delay option (F) requires unit to have CA1 or CA2 factory installed
373
Page 14
14
5100 Series Horizontal or Vertical Mounted Fan Forced Unit Heater
3.3 KW THROUGH 50 KW SUSPENDED FAN FORCED UNIT HEATERS AVAILABLE IN 1 OR 3 PHASE FOR ALL STANDARD VOLTAGES FROM 208V TO 480V THAT CAN BE MOUNTED TO PROVIDE HORIZONTAL OR VERTICAL DISCHARGE.
CONSTRUCTION:
Heavy 18 gauge welded steel cabinet with powder coated nish and control compartment housing
a master terminal board with a hinged and latched access door, simplifying wiring, installation & maintenance.
Taskmaster Dimensions
KW
RATING
H
3.3 - 5.0 17 3/4 14 15/32 6 1/2
7.5 - 10.0 24 5/16 21 1/2 6 1/2
15.0 - 20.0 28 11/16 21 1/2 6 1/2
25.0 - 50.0 34 29 1/4 10 1/16
D
DIMENSIONS (inches)
H W D
Horizontal Discharge
HEATING ELEMENT:
Copper clad steel sheath element
with continuously brazed steel ns
formed to allow side draw through
air ow.
OVERHEAT PROTECTION:
All units come equipped with automatic reset type limit controls to de-energize the heater should an over-temperature situation occur.
FAN and MOTOR:
Totally enclosed, 1-speed, 1-phase, permanently lubricated, thermally protected motors with unit bearings on 3 KW - 20 KW models. Totally enclosed, 2-speed, 1-phase, permanently lubricated, thermally protected motors with sleeve bearings on 25 KW - 50 KW models. All motors mounted with rubber insulators to minimize vibration & noise. Fan over-ride purges unit of residual heat at shutdown.
W
LOUVER ASSEMBLY:
Louvers are individually adjustable for directional control of air ow up to 15° from straight
Vertical Discharge
Manufactured in U.S.A.
FIELD INSTALLED OPTIONS:
• In-unit or wall mounted
temperature control thermostats
horizontal. Optional diffusers available for down ow (vertical discharge) applications.
TEMPERATURE CONTROLS:
Optional low voltage and line voltage thermostats available with an adjustable temperature range of 40°F to 90°F. Units with model numbers ending in CA1 are factory wired for low voltage controls. 25 KW through 50 KW units are designed for two stage heating operation.
low or line voltage.
• Summer fan switch to operate
the fan only.
• Power disconnect switch.
• Heat stratication thermostat.
INSTALLATION:
Unit Heaters can be mounted for horizontal or vertical discharge. Applications up to 6000 Ft. See UH Series above 6000 Ft. ABS (American Bureau of Shipping) type approved.
Installing the Taskmaster Series
DETERMINING HEATER REQUIREMENTS
Calculate the heating loads using the NEMA handbook or ASHRAE guide. Then determine the quantity and
size of unit heaters to be used. To maintain uniform heat and reduce stratied air, it is recommended that the
total CFM of the units turn the air over approximately 3 times per hour. In instances where a large group of people are located and normally in the same area, use a large number of lower KW unit heaters. In warehouse areas or storage rooms where heat distribution and constant temperatures are less important, use fewer heaters of higher capacity.
HORIZONTAL MOUNT
Small rooms can be heated by one unit heater. Where two walls are exposed, heaters should be mounted as
shown in Figure A. In larger rooms, units should he located so their air streams wipe exposed walls without blowing at them. Units should be located so that the air stream of one supports that of another thus setting up a circulatory air movement shown in published air throw.) Units should not be mounted horizontally in areas having ceiling heights in excess of 15-18 ft.
Figure
B. (Distance between units to be approximately 1-1/2 times
VERTICAL MOUNT
Units should be mounted vertically in high bay areas, or where heater location would not interfere with plant
operation or trafc, Heaters should be situated to provide free air circulation. Size and selection of units should
be based on recommended mounting height. Optional diffusers may best be employed to reduce high air velocity and at the same time disperse heated air in a uniform pattern. When unit heaters are used to combat cold air inrush from opened loading dock doors, one or more units should be arranged to blow warm air across opening (Figure C).
DUAL MOUNTING
Where square footage is large and comfort essential, both horizontal and vertical installations may best serve
your requirements as Figure D demonstrates.
Note: Products in this section with factory installed controls are subject to 100% cancellation/restocking charges.
Page 15
HOW TO DESIGNATE A MODEL:
5100 Series Horizontal or Vertical Mounted Fan Forced Unit Heater
Diffuser Options
DESCRIPTION
Louver Diffuser (Standard). Louvers can
be individually adjusted for rectangular
1
coverage over doorways as an air curtain,
or to meet rectangular oor pattern heating
General Distribution (No Diffuser). The
5100 air chute venturi permits general down
2
ow air pattern distribution as required at a
Anemostat Diffuser (Optional). For
3
applications where draft restriction is
required at lower unit mounting heights.
Radial Diffuser (Optional). Individually
adjustable ns permit increased oor
4
coverage at 45° open. Additional throw is
accomplished when ns are 90° vertical.
(Please allow for higher mounting heights.)
requirements.
higher mounting height.
UPC#
686334
692687 681186 681186 722070
692663 692663 692670 692670 722087
MODEL
NUMBER
NA Standard
NA
Not
Required
AD5120 AD5150 AD5150 AD5175
RD5120 RD5120 RD5150 RD5150 RD5175
KW USED
3.3-5
7.5-10 25-30 40-50
3.3-5
7.5-10 25-30 40-50
7.5-10 25-30 40-50 60-70
7.5-20
25-50
60-70
MAX MOUNTING
HEIGHT (ft.)
9 12 18 22 24
9 12 18 22 24
15 17 20 31
45° 90° 45° 90°
10 14 20 18 26
14 21 30 28 36
DIMENSION
A (feet)
36 42 62 68 72
20 40 52 75 84
15 30 40 55 64
38 50 60
DIMENSION
B (feet)
10 22 30 42 47
NA NA NA
NA
-
30 35 44 54 60
NA
WT.
LIST
(lbs.)
NA NA
10 372
12 555
37 598
12 412
14 481
39 519
15
Description 1 Description 2 Description 3
Louver Diffuser
No Diffuser Anemostat Diffuser
Mounting Brackets & Model Designator
(*Included with A5100 bracket.)
Not actual colors. Red & yellow shading is for diagram clarity only.
HF 2 B 51 10 C A 1
Description 4
Radial Diffuser
MOUNTING BRACKETS
UPC#
686334
692694 A5105 3.3 KW TO 5.0 KW 9 lbs. 96 692700 A5120 7.5 KW TO 20.0 KW 13 lbs. 11 7 692717 A5150 25.0 KW TO 50.0 KW 16 lbs. 131 688628 B5105* 3.3 KW TO 20.0 KW 3 lbs. 52 688635 B5150* 25.0 KW TO 50.0 KW 8 lbs. 77 692847 V5105 3.3 KW TO 5.0 KW 9 lbs. 183 692854 V5120 7.5 KW TO 20.0 KW 13 lbs. 224 692861 V5150 25.0 KW TO 50.0 KW 16 lbs. 236
692878 DS5105 3.3 KW TO 5.0 KW 3 lbs. 33 692885 DS5120 7.5 KW TO 20.0 KW 4 lbs. 38 681223 DS5150 25.0 KW TO 50.0 KW 5 lbs. 40
706544 OFG5101 3.3 KW TO 5.0 KW 3 lbs. 53 706551 OFG5102 7.5 KW TO 20.0 KW 4 lbs. 58 706568 OFG5103 25.0 KW TO 50.0 KW 5 lbs. 66
MODEL MODEL SIZE WT.
DUST SHIELD
FAN GUARD
LIST
Element Volts F = 208 H = 240 HF = 240/208 G = 277 P = 480
Phase 1 = 1-Phase 2 = 1 or 3-Ph. 3 = 3-Phase
Motor Voltage F = 208 H = 240 B = 240 / 208 G = 277 P = 480
Model Series 51
Element KW Control System
Blank = None C = Contactor
Transformer Blank = None A = Included
Control Volts 1 = 24 2 = 120 (with CA option)
Page 16
16
5100 Series Horizontal or Vertical Mounted Fan Forced Unit Heater
Standard Taskmaster Models & Series Notes
UPC#
686334
645089 F1F5103N 3.3 11.2 208 1 15.9 208 645102 HF1B5103N 3.3/2.5 11.2 / 8.5 240/208 1 13.7 / 11.9 240 / 208 645683 F2F5103N 3.3 11.2 208 1 / 3 11.9 / 6.9 208
645706 HF2B5103N 3.3/2.5 11.2 / 8.5 240/208
645720 G1G5103N 645126 P3P5103CA1N 480 3 4.0 24 883 645546 F1F5105N 5.0 17.1 208 1 24.1 208 645560 HF1B5105N 5.0/3.7 17.1 / 12.8 240/208 1 20.9 / 18.1 240 / 208
645140 F2F5105N 5.0 17.1 208
645164 HF2B5105N
645843 G1G5105N 5.0 17.1 277 645188 P3P5105CA1N 5.0 17.1 480 3 6.1 24 958 645201 F2F5107CA1L 7.5 25.6 208 1 / 3 36.1 / 20.8
645928 G1G5107CA1L 7.5 25.6 277 1 27.1 645249 P3P5107CA1N 7.5 25.6 480 3 9.1 1204 645263 F2F5110CA1L 9.9 33.8 208 1 / 3 47.8 / 27.4
645287 HF2B5110CA1L
645645 G1G5110CA1N 10.0 34.1 277 1 36.1 645300 P3P5110CA1N 10.0 34.1 480 3 12.1 1275 645324 F3F5115CA1L 15.0 51.2 208 3 41.7 645348 HF3B5115CA1L 15.0/11.2 51.2 / 38.4 240/208 3 36.1 / 31.3 43°F 32’ 11’ 20’ 645362 P3P5115CA1N 15.0 51.2 480 3 18.1 2060 645386 HF3B5120CA1L 19.7/14.8 67.2 / 50.5 240/208 3 47.8 / 41.1 645409 P3P5120CA1N 20.0 68.3 480 3 24.1 645881 F3F5125CA1L 25.0 85.3 208 3 69.5
645980 P3P5125CA1N 25.0 85.3 480 3 30.1 645423 F3F5130CA1L 30.0 102.4 208 3 83.4
645461 P3P5130CA1N 30.0 102.4 480 3 36.2 644044 F3F5140CA1L 40.0 136.5 208 3 111. 2
644082 P3P5140CA1N 39.0 133.1 480 3 47.0 645485 F3F5150CA1L 49.6 169.3 208 3 139.0
645522 P3P5150CA1N 50.0 170.6 480 3 60.3
MODEL KW BTU / H VOLTS PH AMPS
1 / 3 13.7 / 11.9
3.3 11.2
5.0 17.1 240
3.7 12.8 208
7.5 25.6 240 1 / 3 27.1 / 31.3
5.6 19.2 208 1 / 3 31.3 / 27.1
10.0 34.1 240 1 / 3 41.2 / 24.0
7.5 25.6 208 1 / 3 36.1 / 20.8
277 1 11.9 277
3 7.9 / 6.9
1 / 3 24.1
3
20.8 / 18.1 240
1 / 3
12.1 / 10.4 208
1 / 3
1
CONTROL
VOLTAGE
240 / 208
13.9
18.1 277
208
24
TEMP
RISE
26oF 12’ 400 9’ 9’ 25
40oF 12’ 400 9’ 9’
34°F 22’ 700 10’ 12’ 54
45°F 22’ 700 10’ 14’ 55
57°F 32’ 1100 12’ 18’ 65 2719
AIR
THROW
CFM
1100 64
2000/1800 3204645942 HF3B5125CA1L 25.0/18.7 85.3 / 64.0 240/208 3 60.2 / 52.1 40/44°F 45’ 12’ 22’ 120
2000/1800 3709645447 HF3B5130CA1L 30.0/22.5 102.4 / 76.8 240/208 3 72.3 / 62.5 47/53°F 40’ 12’ 20’ 120
RECOMMENDED
MOUNTING HT.
Horizontal Vertical
WT.
(LBS.)
25
27
LIST
693
724
1116645225 HF2B5107CA1L
1230
1980
4742644068 HF3B5140CA1L 40.0/30.0 136.5/102.4 240/208 3 96.4 / 83.4 40/45°F 55’ 3100/2800 15’ 24’ 120
5920645508 HF3B5150CA1L 50.0/37.5 170.6/128.0 240/208 3 120.5/104.3 51/56°F 50’ 3100/2800 15’ 22’ 120
International Models
UPC#
686334
715300 Q3H5103CA1 724920 R3H5103CA1 415 4.6 883 724937 Q3H5105CA1 424944 R3H5105CA1 415 6.96 958 717137 Q3H5107CA1 724951 R3H5107CA1 415 10.5 1204 686570 Q3H5110CA1 724968 R3H5110CA1 415 13.9 1275 724975 Q3H5115CA1 724982 R3H5115CA1 415 20.9 2066 704175 Q3H5120CA1 724999 R3H5120CA1 415 27.85 719193 Q3H5125CA1 710619 R3H5125CA1 415 34.8 725002 Q3H5130CA1 710626 R3H5130CA1 415 41.8 725019 Q3H5140CA1 709835 R3H5140CA1 415 55.7
MODEL KW BTU/H VOLTS PH AMPS
3.3 11263
5.0 17065
7.5 25600
10.0 34130
15.0 51195
20.0 68260
25.0 85325
30.0 102390
40.0 136520
380
380 7.6
380 11.4
380 15.2
380 22.8
380 30.4
380 38.0
380 45.6
380 60.85
3
CONTROL
VOLTAGE
5.02
24
TEMP
RISE
40/44 45’
47/53 40’ 12’ 20’ 3709
40/45 55’ 3100/2800 15’ 24’ 4742
AIR
THROW
26
12’ 400 9’ 9’
40 27
34
22’ 700
45 10’ 14’ 55
43
32’ 1100
57 12’ 18’ 65 2719
CFM
2000/1800
• For 24V control add “CA1” sufx and $101 list. • For 120V control add “CA2” sufx and $101 list.
• For other voltages consult factory.
NOTES:
• 25-50KW models are wired for single or two stage heating and have two speed motors.
• Air delivery and motor data on dual voltage units reect higher voltage.
• 600 Volt models available in 5 KW through 30 KW. Contact factory for delivery.
• Supply wire on 40 and 50 KW models should have rated insulation of 75oC minimum.
• Use T5122 for two stage control.
• Use TW123 for two stage control.
• Use TFS5102 for two stage control.
• Wall thermostat must be used when built-in stratication thermostat is required.
RECOMMENDED
MOUNTING HT.
Horizontal Vertical
10’ 12’ 54
11’ 20’ 64
12’ 22’
WT.
(LBS.)
25
120
LIST
693
724
1116
1230
1980
3204
Page 17
5100 Series Horizontal or Vertical Mounted Fan Forced Unit Heater
Recommended Control Options, Control Accessory Options, & Control Accessories
DISCONNECT
MODEL
F1F5103N
HF1B5103N
F2F5103N
HF2B5103N
G1G5103N DCS 202 NA
P3P5103CA1N NA DCS 403 A6176 FS5102 FSW5112 TFS5101 TC5102 NA
F1F5105N
HF1B5105N ET5SS
F2F5105N
HF2B5105N
G1G5105N DCS 202 NA
P3P5105CA1N NA DCS 403
F2F5107CA1L
HF2B5107CA1L
G1G5107CA1L DCS 403 NA NA
P3P5107CA1L NA DCS 403 FS5102 FSW5112 TC5102 NA
F2F5110CA1L
HF2B5110CA1L
G1G5110CA1N DCS 403 NA NA
P3P5110CA1N
F3F5115CA1L DCS 603
HF3B5115CA1L DCS 403
P3P5115CA1L DCS 403 FS5102 FSW5112 NA
HF3B5120CA1L DCS 603 FS5101 FSW5111 TC1602
P3P5120CA1N DCS 403 FS5102 FSW5112 NA
F3F5125CA1L
HF3B5125CA1L
P3P5125CA1N DCS 403 FS5102 FSW5112 NA
F3F5130CA1L DCS 1003
HF3B5130CA1L DCS 1003
P3P5130CA1N DCS 403 FS5102 FSW5112 NA
F3F5140CA1L NA
HF3B5140CA1L DCS 403
P3P5140CA1N DCS 603 FS5102 FSW5112 NA
F3F5150CA1L
HF3B5150CA1L
P3P5150CA1N DCS 1003 FS5102 FSW5112 NA
CONTROL ACCESSORY OPTIONS - FIELD INSTALLED IN HEATER
UPC#
686334
717151 DCS202 / 5100 2 POLE; 20 AMP; 120-277 V.A.C. 134 717168 DCS403 / 5100 3 POLE; 40 AMP; 120-600 V.A.C. 303 717175 DCS603 / 5100 3 POLE; 60 AMP; 120-600 V.A.C. 442 717182 DCS1003 /5100 3 POLE; 100 AMP; 120-600 V.A.C. 497
692779 T5100 SPST; LINE DUTY 25 AMP 120-277V 121
692786 T5102 DPST; LINE DUTY 25 AMP 120-277V 164
692779 T5100
692793 T5122
692809 TC5102
692816 TC5103
692823 FS5101 SPST; LINE VOLT ;120-277V 69 692830 FS5102 SPST; LINE VOLT ; 480-600V 100
MODEL DESCRIPTION LIST
LINE VOLTAGE THERMOSTAT (45 - 90 oF)
LOW VOLTAGE THERMOSTAT (ALL CA1 MODELS) (45 - 90 oF)
SWITCH
1 Ø 3 Ø IN-BUILT
DCS 202 NA T5100 ET5SS
NA DCS 403 T5102 TW 1512
DCS 202 NA T5100 ET 5SS
NA DCS 403 T5102 TW 1512
DCS 403 NA
NA DCS 403 T5102 TW 1512
DCS 403 NA T5100 ET5SS
NA DCS 403 T5102 TW 1512
DCS 403 NA
NA DCS 403
DCS 403 NA
NA DCS 403
DCS 603 NA
NA DCS 403
DCS 603 NA
NA DCS 403
DCS 403 FS5102 FSW5112
DCS 1003
NA
NA FS5101 FSW5111 TC1602
POWER DISCONNECT SWITCH
SPST; LOW VOLT/PILOT DUTY; 125VA;
(3.3-20 KW UNITS)
2-STAGE; LOW VOLT; 125VA; (25-50
STRATIFICATION THERMOSTAT
SPST; LOW VOLT/PILOT DUTY (W/
RELAY) ; 70-130
SPST; LINE DUTY; AMP 120-240V; 70-
SUMMER FAN SWITCH
THERMOSTAT SUMMER FAN SWITCH
T5100
T5100
T5100
KW UNITS)
O
130
WALL
MOUNTED
ET5SS NA
S2025
S2025
S2025 NA
A6176
A6176
OR
TW123
O
IN-BUILT
FS5101 FSW5111 NA
FS5101 FSW5111 NA
FS5102 FSW5112
FS5101 FSW5111
FS5101 FSW5111
FS5101 FSW5111 TC1602
FS5101 FSW5111
FS5101 FSW5111 TC1602
FS5101 FSW5111 TC1602
UPC#
686334
502917
538787 ET5SS SP; 22 Amp; 120-277V; 50-90OF 27.30
691093 *TW1512 DPST; 25 AMP; 120-277V; 50-90oF 196
260008 A6176 SPST; (3.3 - 20 KW UNITS); 50-90OF 104 691116 TW123 2-STAGE; (25 - 50 KW UNITS); 40-90OF 200
691109 TC1602 SPST; LINE VOLT; 120-277V; 70-140
121
180
692625 FSW5111 SPST; LINE VOLT; 120-277V 86
692632 FSW5112 SPST; LOW VOLT; (W/RELAY) 186
184
692649 TFS5101 SPST; LOW VOLT; 50-90
123
692656 TFS5102 2-STAGE; LOW VOLT; 50-90
**Any SPST thermostat of sufcient amperage may be substituted.
*Use DPST thermostat for 3-phase line voltage control in non “C” models.
WALL
MOUNTED
CONTROL ACCESSORIES - REMOTE WALL MOUNTED
MODEL DESCRIPTION LIST
S2025H10AA SP; 25 Amp; 120-277Vl; 50-90OF 51
LOW VOLTAGE THERMOSTAT (ALL CA1 MODELS)
LOW VOLTAGE T’STAT & SUMMER FAN SWITCH(W/RELAY)
THERMOSTAT &
SUMMER FAN
SWITCH
WALL MOUNTED
TFS5101
TFS5101
LINE VOLTAGE THERMOSTAT
STRATIFCATION THERMOSTAT
SUMMER FAN SWITCH
(CA1 MODELS)
STRATIFICATION
IN-BUILT
TC5103
TC5103
TC5102 NA
TC5103
TC5103
TC5103
THERMOSTAT
WALL
MOUNTED
TC1602
TC1602
TC1602
TC1602
NA
TC1602
O
O
O
17
197
200 401
Page 18
18
COM
001-0102
S
V
C4
C1
C2 C3
POWER
REV.1
JUNE 99
32
200
ON
90
100
TEST
1
2
60
4
3 5 6
DELAY(s)
150
RATIO(%)
ON
1
1
2
3
3
1
2
4
4MA-O%HEAT
20MA-100%HEAT
0-10VDC-CONTROL
OR C1025 WALL
THERMOSTAT
3 OR 4 STAGE
STEP CONTROL
INPUT
CONTROL
12030
VR1
VR2
C
+ _
5100 Series 60 KW - 100 KW Suspended Fan Forced Unit Heater
Features & Specications
CONSTRUCTION:
Heavy gauge steel cabinet with powder coated nish and control compartment
housing a master terminal board. The control compartment allows for access through a hinged and latched door, simplifying wiring, installation, and maintenance.
HEATING ELEMENT:
The heating element is a copper clad steel sheath element with continuously brazed steel
ns formed to allow side draw through air ow.
OVERHEAT PROTECTION:
All units come equipped with manual reset type limit controls to de-energize the heater should an over-temperature situation occur.
FAN & MOTOR:
Single speed, single phase permanently lubricated, thermally protected motors with ball bearings. The fan override purges the unit of residual heat at shutdown.
FIELD INSTALLED OPTIONS:
Summer fan switch to operate the fan only, and a heat stratication thermostat for high
bay areas.
HEATER STAGING:
60 KW and 70 KW are three stage; 80 KW, 90 KW, & 100 KW are four stage.
SC5100 FACTORY INSTALLED ELECTRONIC STEP CONTROLLER:
The optional factory installed step controller is a rst on last off sequencer that will cycle
the unit heater stages through an optional wall thermostat. Additionally, the step controller
can be controlled by any building management system with 4 to 20 MA or 0 - 10 VDC eld
Manufactured in U.S.A.
supplied control signal.
Optional Factory Installed Electronic Step Controller
Dimensions
Dimensions (Inches)
KW H W D
60-70 35 1/2 30 1/2 14 1/2 141
80-100 39 1/2 37 5/8 18 1/2 202
WT
(LBS.)
Mounting Brackets and Accessories
UPC#
686334
7220002 A5175 60 To 70
7220102 A51100 80 to 100 189
Model Heater KW Description LIST
7220302 B5175 60 to 70
7220402 B51100 80 to 100 101
7220202 V51100 60 to 100 Vertical Bracket 314
Wall / Ceiling Bracket
7220502 DS5175 60 to 70
7220602 DS51100 80 to 100 57
7220902 OFG 5175 60 to 70
7221002 OFG 51100 80 to 100 97
Mounting Brackets
Wall/Ceiling Bracket
Heater Bracket
Dust Shield
Fan Guard
181
82
49
78
Page 19
5100 Series 60 KW - 100 KW Suspended Fan Forced Unit Heater
Electrical Data
UPC#
686334
Catalog Number KW
BTU/HR
(x 1000)
Voltage Phase Control Voltage Amps / Phase
Branch Circuit
Protection Size
19
LIST
721349 F3F5160CA1 60 204.7 208
3 24
721363 P3P5160CA1 60 204.7 480 72.3 100
721424 F3F5170CA1 70 238.9 208
3 24
721448 P3P5170CA1 70 238.9 480 84.3 110
721707 HF3B5180CA1 80/60 273/204.7 240/208
3 24
721714 P3P5180CA1 80 273 480 96.3 125
721769 HF3B5190CA1 90/67.5 307.1/230.4 240/208
3 24
721776 P3P5190CA1 90 307.1 480 108.4 150
721820 HF3B51100CA1 100/75 341.3/256 240/208
3 24
721837 P3P51100CA1 100 341.3 480 120.4 175
166.7 225
194.4 250
192.8/166.7 250/225
216.9/187.5 300/250
241/208.3 350/300
Air Delivery Data
UPC#
686334
721349 F3F5160CA1
721356 HF3B5160CA1 60/45
721363 P3P5160CA1 60
721424 F3F5170CA1 70
721431 HF3B5170CA1 70/53
721448 P3P5170CA1 70
721707 HF3B5180CA1
721714 P3P5180CA1 55
721769 HF3B5190CA1 61/46
721776 P3P5190CA1 61
721820 HF3B51100CA1 68/51
721837 P3P51100CA1 68
Catalog Number CFM at Outlet FPM at Outlet
3400 1485
5000 1529
Temp Rise
°F
60
55/41
HP Motor RPM Air Throw
1/3 1100 50’ 18’ 31’
3/4 1100 65’ 22’ 40’
Max Mounting
Horizontal Vertical
8135721356 HF3B5160CA1 60/45 204.7/153.6 240/208 144.6/125 200/175
8480721431 HF3B5170CA1 70/52.5 238.9/179.2 240/208 168.7/145.8 225/200
9912
10312
10886
Recommended Control Options
UPC#
686334
721349 F3F5160CA1
721356 HF3B5160CA1 FS5101
721363 P3P5160CA1 FS5102 104
721424 F3F5170CA1 FS5101
721431 HF3B5170CA1 FS5101
721448 P3P5170CA1 FS5102 104
721707 HF3B5180CA1 FS5101 71
721714 P3P5180CA1 FS5102 104
721769 HF3B5190CA1 FS5101 71
721776 P3P5190CA1 FS5102 104
721820 HF3B51100CA1 FS5101 71
721837 P3P51100CA1 FS5102 104
Catalog Number
Step Controller Thermostat
Model List Model List Model List Model List Model List Model List
SC5100 654 C1025 194 FSW5112 186
Note: Products listed in this section are custom built and subject to 100% cancellation/restocking charges.
Summer Fan Switch Stratication Thermostat
Wall Built-In Wall Built-In
FS5101
71
71
TFS5101 200 TC5102 184
Page 20
20
2600 Series Downow Unit Heater
General Description & Diffuser Information
CONSTRUCTION:
• 16 gauge steel cabinet with epoxy powder coated nish and control compartment with a hinged and
latched access door.
• OSHA guards standard with all models.
HEATING ELEMENT:
• Corrosion resistant element with steel sheath and steel spiral ns.
OVERHEAT PROTECTION:
• All units come equipped with manual reset limit controls to de-energize the heater should an over-temperature situation occur.
FAN and MOTOR:
• Totally enclosed, 1 speed, 1 phase permanently lubricated, thermally protected motors with unit bearings on 3KW - 20KW models. Totally enclosed, 2 speed, 1 phase permanently lubricated, thermally protected motors with sleeve bearings on 24KW - 50KW models.
• Axial ow fan blade - 1570 RPM max.
• All models equipped with fan purge which allows fan to operate after elements are de-energized to purge residual heat.
TEMPERATURE CONTROLS:
• 208V, 240V, 277V and 480V units have In-Built 24 Volt transformer for low voltage remote thermostat application.
• 600V units have In-Built 240V control on 5-20 KW models, 25-50 KW models have 24V control.
• 25 KW - 50 KW models may operate as 2 stage heaters if 2 stage remote thermostat is used.
DISCONNECT SWITCH:
• All models equipped with In-Built disconnect except F3F2640, F3F2650 and H3H2650.
INSTALLATION:
• Unit can be mounted using optional mounting bracket or eld constructed angle iron bracket.
• Not recommended for mounting with threaded rod or chain.
Standard Heater Anemostat DiffuserRadial Louvered Cone Diffuser Linear Louvered Diffuser
Manufactured in U.S.A.
2600 Series shown with
standard wire guard.
Diffusers are eld installed.
Dimensions**
KW
20 1/2”
5-20
25-50
A
B
For general distribution.
Choice of other diffusers
may be added after
installation if required.
O.S.H.A guard for
fan blade D1604 for
2605-2620, & D1614 for
2625-2650 Do not use
Diffuser Descriptions
MODEL
2605 2607 2610 2615 2620 2625 2630 2640 2650
*Minimum mounting height 6 feet. **Dimensions are for all heater models without a diffuser option. Adding a diffuser will change the vertical (”A”) dimension of heater. All mounting distances are in feet. All diagrams show optional mounting bracket.
with other diffusers.
MAX
MOUNTING
HEIGHT*
10 10 22 20 18 32 30 26 24
B
D'
D
(ft.)
25 25 40 44 48 48 60 64 68
A
B
15”
21 1/2”
27”
A
B
MODEL MODEL MODELDIM: A DIM: A DIM: ADIM: B DIM: B DIM: B
D1600
D1610
With vanes vertical, straightens air for higher
mounting. Closed position for broad horizontal
VERTICAL 45 DEGREES OPEN
MAX
MOUNTING
HEIGHT
15 15 26 24 22 38 36 32 28
KW
5-20
25-50
coverage. Adjustable for intermediate
(ft.)
25 25 36 38 40 42 50 50 50
requirements.
D'
D
MOUNTING
6 1/2"
11 1/2"
MAX
HEIGHT
8
8 15 14 13 24 22 20 18
14 1/4"
24 3/4"
D
(ft.)
30 30 44 46 50 70 74 78 82
A
B
B
KW
D1602
D1612
MOUNTING
5-20
25-50
Affords more precise directional
throw where heaters cannot be
mounted directly over area to be
heated or for heating long narrow
MAX
HEIGHT
10 10 22 20 18 34 32 30 28
areas.
W'
W
(ft.)
10 10 14 14 15 30 34 36 40
6"
6"
L'
16 1/4"
22 1/4"
L
(ft.)
40 40 54 60 66 80 80 90
100
D1603
D1613
A
B
KW
5-20
7"
19 1/4"
9 3/4"
25-50
Blends room air with
heated air for widespread
distribution without
excessive drafts.
MAX
MOUNTING
HEIGHT
9
9 20 18 16 30 28 26 24
29 3/4"
D'
(ft.)
25 25 38 40 42 60 64 67 70
D
Page 21
2600 Series Downow Unit Heater
Product Specications
SPECIFICATIONS: The contractor shall furnish and install the 2600 Series electric vertical discharge unit heaters of the size, capacity and
voltage specied. Heaters shall be installed according to the manufacturer’s recommendations and applicable national and local codes.
ELEMENTS: Elements shall consist of Nickel Chromium alloy resistance wire embedded and completely surrounded in Magnesium Oxide,
enclosed and swagged into corrosion resistant sheaths. Corrosion resistant steel ns shall be permanently attached to the sheaths to provide
maximum heat transfer to the air stream.
MOTORS: Motors shall be single phase, resilient mounted, totally enclosed, industrial rated with an automatic reset thermal overload protective device. Motors on heaters up to 20 KW capacity shall be permanently lubricated shaded pole type. Over 20 KW, motors shall be permanent split capacitor type. Motors shall be mounted out of the main air stream in such a manner as to allow ambient air to be drawn over the motor to reduce motor temperature. Motor shall be separately removable from beneath the heater without removing the entire heater from mounting bracket.
FAN BLADES: Fan blades shall be heavy-duty individually balanced axial ow type. Fan speed shall not exceed 1570 RPM.
THERMAL OVERLOAD PROTECTION: All heaters shall be equipped with a manual reset thermal cutout which disconnects elements and
motor in the event normal operating temperatures are exceeded.
WIRING: Heaters shall be designed for a single supply circuit with elements, motor and control circuits subdivided and fused to conform with the latest National Electric Code and OSHA requirements. All three phase heaters shall have balanced phases.
CONTROLS: Heaters shall be controlled by a low voltage wall mounted thermostat. All heaters 25 KW and larger shall be wired for 2 stage operation. 5 KW through 20 KW units are single stage. All heaters shall be equipped with a fan safety device that causes fan to operate after elements are de-energized to purge unit of residual heat.
Standard Models
UPC#
686334 715751 F1F2605CA1
715768 H1H2605CA1 240 20.83 715775 G1G2605CA1 277 18.05 715782 F3F2605CA1 208 715799 H3H2605CA1 240 12.04 715805 P3P2605CA1 480 6.02 715812 U3H2605CA4 600 4.81 240 715829 F1F2607CA1 715836 H1H2607CA1 240 31.25 715843 G1G2607CA1 277 27.07 715850 F3F2607CA1 208 715867 H3H2607CA1 240 18.06 715874 P3P2607CA1 480 9.03 715881 U3H2607CA4 600 7.22 240 715898 F1F2610CA1 715904 H1H2610CA1 240 41.66 715911 G1G2610CA1 277 36.1 715928 F3F2610CA1 208 715935 H3H2610CA1 240 24.08 715942 P3P2610CA1 480 12.04 2345 715959 U3H2610CA4 600 9.63 240 3061 715966 F3F2615CA1 715973 H3H2615CA1 240 36.12 715980 P3P2615CA1 480 18.06 2559 715997 U3H2615CA4 600 14.45 240 3596 716000 H3H2620CA1 19.4 716017 P3P2620CA1 717502 U3H2620CA4 600 19.26 240 3991 717519 F3F2625CA1 717526 H3H2625CA1 240 60.21 717533 P3P2625CA1 480 30.1 3571 717540 U3U2625CA1 600 24.08 4356 717557 F3F2630CA1 717564 H3H2630CA1 240 72.25 717571 P3P2630CA1 480 36.12 4286 717588 U3U2630CA1 600 28.9 5431 717595 F3F2640CA1
717618 P3P2640CA1 480 48.16 717625 U3U2640CA1 600 38.53 6146 717632 F3F2650CA1
717656 P3P2650CA1 480 60.21 717663 U3U2650CA1 600 48.16 6861
MODEL KW BTU’s VOLTS PH AMPS
5 17065
7.5 25598
10 34130
15 51195
68260
20
25 85325
30 102390
40 136520
50 170650
208
208
208
208 41.68
240 48.16 480 24.08 3096
208 69.48
208 83.37
208 111.17
208 138.96
24.03
1
13.89
3
36.05
1
20.84
3
48.07
1
27.79
3
CONTROL
VOLTS
24
24
24
24
24
24
TEMP
RISE OF
34 490 75
45 560 75
26 1200 75
39 1200 75
52 1200 75
24 3300 175
29 3300 175
38 3300 175
48 3300 175
CFM
WT
(LBS.)
LIST
1129
1381
1452
1595
1988
2273
2631
3499
3820
5073717601 H3H2640CA1 240 96.33
5787717649 H3H2650CA1 240 120.42
21
Page 22
2600 Series Downow Unit Heater
22
Field Installed Accessories
UPC#
686334
692632 FSW5112 Summer Fan Switch 186
691109 TC1602
717755 A1600 Ceiling Mount Bracket 5-20 KW Models 120
717762 A1601 Ceiling Mount Bracket 25-50 KW Models 134
MODEL DESCRIPTION LIST
Wall Mounted Stratication Thermostat
Range - 70 oF - 140 oF
184
5700 Series Conned Space Plenum Rated Heater
UPC#
686334
717793 D1602 Linear Louvered Diffuser 5-20 KW Models 401
717809 D1612 Linear Louvered Diffuser 25-50 KW Models 598
717816 D1600 Radial Louvered Cone Diffuser 5-20 KW Models 444
717823 D1610 Radial Louvered Cone Diffuser 25-50 KW Models 519
717830 D1603 Anemostat Diffuser 5-20 KW Models 401
717847 D1613 Anemostat Diffuser 25-50 KW Models 598
MODEL DESCRIPTION LIST
Features
• Easily ts between joists for typical installation.
• Zero clearance for wall and ceiling mounting as well as oor
mounting with appropriate inlet and outlet clearances.
• Bracket standard or can be mounted by 3/8” threaded rod
(eld supplied)
• Automatic reset thermal limit for safety
• 1 Phase model wattage eld changeable from 1874 to 5000
Watts.
• 24V control circuit on three phase models with hydraulic thermostat
Conforms to ANSI/UL 1995
Certied to CAN/CSA C 22.2 No.236-11
Product Dimensions
A
E
B
D
F
G
A B C D E F G
C
14.4” 19.4” 14.5” 8.4” 5.1” 9.2” 1.8”
Standard Models
UPC#
686334
726245 HF5705T
727252 H3H5705T
726269 P3P5705T 5000 17065 480 3 6 57 oF 16' 275 32
707367 DCS-MT303 Optional Field Installed Disconnect Switch, 30 Amp @ 600Volts 63
MODEL WATTS BTU's VOLTS PHASE AMPS TEMP RISE
5000 17065
4165 14215 17 48 oF
3332 11365 14 38 oF
2500 8533 10 29 oF
3750 12798
3123 10659 15 36 oF
2500 8553 12 29 oF 16' 275
1874 6396 9 21 oF
3750 12799 208 3 10.4 57 oF 16’ 375 32
5000 17065 240 3 12 57 oF 16' 275 32
For 24V control on single phase models delete "T" sufx 146
240 1
208 1
21 57 oF
18 43 oF
AIR
THROW
CFM
16' 275 32
WT.
(LBS.)
32
LIST
772
832
Page 23
5600 Series Multiple Wattage Fan Forced Unit Heater
CASING: Fabricated of die formed, heavy
gauge steel and nished with two tone,
brown and beige, durable powder coated paint. Supply air is drawn through the rear heavy duty expanded steel inlet grill. Heated air is discharged through front adjustable louvers, which are spring loaded for individual adjustment.
ELEMENT: Heavy-duty block n
element design. The multiple tap electric
connection design allows eld conversion
to eight wattage settings at 208/240-Volt single phase or 240/480 Volt, 3 phase. Units are available on special order with a
specic wattage/voltage setting.
MOTOR: Motor shall be totally enclosed, permanently lubricated, all angle industrial rated with thermal overload protection.
Product Specications
Product Specications
23
WIRING: Wiring to terminal block adjacent to incoming knockout in accordance with NEC and local codes.
Front view
Manufactured in U.S.A.
THERMAL OVERLOAD: All heaters shall be equipped with an automatic reset thermal cutout to shut down the element and motor circuits if unsafe operating temperatures are exceeded.
CONTROLS: The heater shall have a heavy-duty hydraulic thermostat factory installed and wired. All controls and wiring shall be in a large wiring compartment with hinged door for easy access. An optional disconnect switch shall
be available for eld installation.
MOUNTING: Heaters are standard with a three position-mounting bracket for wall, ceiling or workbench. Heaters can be mounted for horizontal or vertical discharge. Note: Minimum mounting height is 6 feet, and minimum distance from side of heater to nearest wall is 6 inches. Note: Approved for residential applications.
Product Dimensions
A B C D E F G
14” 12-11/16” 14” 1-9/16” 1-9/16” 9” 2-3/4”
Standard Models
UPC#
686334
707282 HF5605T
707299 H3H5605T
707305 P3P5605T 5000 17065 480 3 6 57 oF 16' 275 32
707367 DCS-MT303 Optional Field Installed Disconnect Switch, 30 Amp @ 600Volts 63
MODEL WATTS BTU's VOLTS PHASE AMPS TEMP RISE
5000 17065
4165 14215 17 48 oF
3332 11365 14 38 oF
2500 8533 10 29 oF
3750 12798
3123 10659 15 36 oF
2500 8553 12 29 oF 16' 275
1874 6396 9 21 oF
3750 12799 208 3 10.4 57 oF 16’ 375 32
For 24V control on single phase models delete "T" sufx 146
240 1
208 1
21 57 oF
18 43 oF
AIR
THROW
CFM
16' 275 32
WT.
(LBS.)
32
LIST
772
8325000 17065 240 3 12 57 oF 16' 275 32
Page 24
24
6300 Series Multiple Angle Cabinet Unit Heater
Product Specications
The electric cabinet unit heater is designed for mounting in any position, fully recessed, semi-recessed or surface mounted. All capacities, voltages, physical sizes, grille arrangements and options
shall be as specied on the plans. All units must be eld convertible
to the following:
1. For control by a eld supplied remote thermostat.
2. Load management control with an external dry switch. When closed unit operates under control of either the internal or the external thermostat. When open, unit turns off.
3. Any grille arrangement.
CABINET: The cabinet shall be constructed of heavy duty 16 gauge
Manufactured in U.S.A.
lters and all internal components. The grill conguration must be easily eld convertible to any air ow conguration (by removal of no more than four fasteners). The cabinet shall have a textured nish of two coats of powder coat epoxy and be
suitable for use with optional kick space base.
HEATING ELEMENTS: The heating elements shall be warranted for 1 year and shall be non-glowing design consisting
of special high temperature resistance wire enclosed in an incoloy sheath to which steel ns are furnace brazed. The heating
elements shall be located directly in front of the blower discharge air for uniform heating. They shall be mounted with a single anchor at one end to minimize effects of thermal expansion and contraction.
Zinc coated steel. The heater shall have a removable front door for easy access to the control panel, elements, motor-blower assembly,
SAFETY CUTOUT: Thermal safety limits shall be built into the system to automatically shut off heater in event of overheating due to any cause. The safety cutouts shall be of two types: A. The primary limit shall be an automatic capillary type to sense the heat along the full length of the heating elements. It shall
de-energize the heaters by opening the coil circuit on the heating contactors.
B. The secondary limit shall be a manual reset thermal device to interrupt power to the heating elements.
MOTOR AND BLOWER ASSEMBLY: The motors and blowers shall be direct drive and resiliently mounted on rigid heavy gauge frame for quiet operation and long life. The motor shall be two-speed, shaded pole type, rated for the voltage (480 to 600 Volts are single speed only). Each shall have built-in automatic reset overload protection and are life time lubricated. The motor shall be vented and mounted in the air stream to provide maximum cooling of the motor.
HIGH AND LOW HEAT RANGES: All units will be supplied as standard with a switch for selecting full heat at high fan speed or reduced heat at low fan speed (On 480 & 600 Volt units the switch changes the heat but not the fan speed).
OVER CURRENT PROTECTION: Circuit breakers shall be provided for branch circuit protection where required by NEC. Circuit breakers are optional on all other heaters.
TEMPERATURE CONTROL: Integral factory installed thermostat shall be tamper resistant, linear capillary type.
Mounting Congurations
Up Flow Down Flow
A
W W
W
C
B
Y Y Y Z X X XZ
A A
Z Z
A
D D D
C
Y
Completely
Recessed
W
B
Semi
Recessed
D D D
A
B
C
W
Recessed
A
D D D
Completely
Recessed
YYY
Completely
Recessed
Z
Semi
Semi
Recessed
Ceiling Mounted
KEY: W = 6” minimum, X = 12” minimum, Y = 0” or greater, Z = 24” minimum
NOTE: Semi-recessed units are to be re­cessed at a maximum of 3 1/2” unless grill
conguration is front in and front out.
MOUNTING CLEARANCES: Proper clearances are indicated for each mount­ing conguration on all positions. Mini­mum clearance from side of unit to the wall is zero inches. Mounting inches are provided in the back of the cabinet, ac­cessible through the blower compart-
XXXX
ment, if necessary, remove blower deck if additional mounting screws or bolts are desired. Blower deck may be slipped for­ward by loosening four screws at the front to provide access to mounting holes.
Page 25
6300 Series Multiple Angle Cabinet Unit Heater
Product Features (2-24 KW; All Voltages)
• For commercial and institutional application such as stores,
schools, ofces, transportation terminals, churches, entrance
ways.
• Wall or ceiling mount; surface, semi-recessed or fully recessed.
• (8) air inlet and outlet congurations.
• Capacities from 2-24 KW with 230 to 1,000 CFM
• Motors are two speed, shaded pole, resilient mounted, direct drive. High/low heat and blower speed offer versatility.
• ETL Listed.
Product Dimensions
Mounting Hole Locations
(Back View of Unit)
• Beige powder coated nish
• Choice of eight standard control options include unit or wall mounted 120 or 24V thermostats, with or without built-in control transformers.
• Industrial type nned tubular elements.
• Easily removable fan and element decks for simplied
maintenance.
• Full length thermal protection.
• Limited warranty-one year.
1/2”, 3/4” Conduit
1/2”, 3/4” Conduit
1/2”, 1-1/2” Conduit
25
1/4” Dia. Mounting Holes
25”
11-11/16”
12”
Knockouts
24” 44” 56”
4-1/16”
Stocked Models & Features
HEATER
LENGTH
33”
46”
33”
46”
*Factory wired for 3-phase, eld convertible to 1-phase.
UPC#
686334
667142 6333D052033B30D0F
667081 6333D054833B30D0F 7.8 4.6 480 3
667197 6346D102433B30D0F
667203 6346D104833B30D0F 15.4 8.1 480 3
473620 6333D053834B30D0F1
473637 6333D054134B30D0F1 6.97 4.18 415
473644 6346D103834B30D0F1
473651 6346D104134B30D0F1 13.94 8.36 415
MODEL
KW BTU’s AMPS CFM KW BTU’s AMPS CFM
5 17065
10 34130
5 17065
10 34130
1 / 3 phase eld convertible with 24 Volt control circuit.
Disconnect switch, dust lter, & high low operation.
Built-in thermostat and eld convertible for remote thermostat.
HIGH LOW
25.0 / 17.6
43.6 / 30.7
International Models
7.6
15.2
Accessories
3/5 KW = 33” 6/10 KW = 46”
250 3 10239
500 6 20478
250 3 10239
500 6 20478
2-3/8”
15.4 / 9.2
26.9 / 16.2
4.56
9.12
2-3/4”
VOLTS PHASE
208 1-3*
230
240 1-3*
460
380
230
380
460
3-3/8”
25”
1-9/16”
3
(4-Wire)
9“
Wt.
(lbs.)
99 3105667159 6333D052433B30D0F 21.8 / 15.4 13.5 / 8.2 240 1-3*
130 3502
99 3105
130 3502
3“
LIST
UPC#
MODEL SIZE DESCRIPTION
686334
DUCT COLLAR
441568 DC-33 33"
441575 DC-46 46" 215
441582 DC-66 66" 269
441599 DC-79 79"
453783 TF-33 33"
453790 TF-46 46" 180
453806 TF-66 66" 224
453813 TF-79 79"
The same model is used for the inlet or outlet. If duct collars are required for both inlet & out-
let then 2 must be ordered.
RECESSING TRIM FRAMES
Recessing Trim Frames should be ordered
to "trim-out" any recessed or semi-recessed
installation.
LIST
177
328
160
247
UPC#
686334
Fresh Air Make-Up Intake Flange & Kickbase
771580 FAM33 33" 349
771597 FAM46 46" 402
771603 FAM66 66" 620
771610 FAM79 79" 681
771542 KB33 33" 139
771559 KB46 46" 147
771566 KB66 66" 178
771573 KB79 79" 194
MODEL SIZE LIST
Kickbase (Pedestal) ONLY
Page 26
26
6300 Series Multiple Angle Cabinet Unit Heater
Custom Specied Models
HOW TO DESIGNATE A MODEL:
63 46 D 08 24 1 2 B3 S D O F
Number of Wires in Electrical Service
2 or 3
B3, B4, B5, B6
Control Options
(see control options chart)
Summer Fan Switch
S = Included O = Not Included
Disconnect Option
O = None
C = Circuit Breaker D = Disconnect Switch
Motor Fusing Option
M = Required O = Not Required
480V
600V
Phase
D = Front in / Front out
C = Front in / Top out
Element KW
2KW through 24KW
250 230
See model chart for length and KW options.
Element Voltage
20 = 208V 24 = 240V 27 = 277V
41 = 415V 48 = 480V 57 = 600V
CFM
1 = Single Phase 3 = Three Phase
1-PHASE UNITS - AMPS (HIGH) 3-PHASE UNITS - AMPS (HIGH)
208V 240V 277V 600V 208V 240V
10.6 9.3 8.12 3.83 9.22 8.13 4.14 3.33 2514
Series Number
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Step 11 Step 12
LENGTH
33”
Cabinet Size
Air Flow Conguration
33=33” 46 = 46” 66 = 66” 79 = 79”
A = Bottom in / Top out B = Bottom in / Front out
KW
High Low Left Right High Low 3-WIRE
2 1 2
3 2 3 15.4 13.5 11.7 5.5 9.22 8.13 4.14 3.38 2589
4 2 4 20.2 16.7 15.3 7.2 13.4 11.8 6 6.22 2692
Elements per
Heat Deck
Disposable Filter Option
F = Required O = Not Required
LIST
46”
66”
79”
5 3 5 25 21.8 19 8 17.6 15.4 7.8 5.5 2814
6 3 6 29.9 26 22.6 10.5 17.6 15.4 7.8 6.3 2935
4 2 2
6 4 3 30.8 26.9 23.1 10.79 18.4 16.2 8.1 6.5 2993
8 4 4 40.4 35.2 30.5 14.12 26.7 23.4 11.7 9.4 3131
10 6 5 50 43.6 37.7 17.5 35.1 30.7 15.4 12.3 3258
12 6 6 59.6 51.9 44.9 20.8 35.1 30.7 15.4 12.3 3325
6 3 2 2
9 6 3 3 46.2 40.4 35 16.3 27.6 24.3 12.3 9.9 3791
12 6 4 4 60.6 52.9 45.8 21.3 40.1 35.2 17.7 15.6 3938
15 9 5 5 75 65.4 56.7 25.5 52.6 46.1 23.1 15.7 4075
18 9 6 6 89.4 77.9 67.5 31.3 52.6 46.1 23.1 18.5 4222
8 4 2 2
12 8 3 3 61.5 53.8 46.5 21.6 36.7 32.3 16.2 13 4164
16 8 4 4 80.7 70.5 61 28.2 53.4 46.8 23.5 18.8 4323
20 12 5 5 NA 87.1 75.4 34.9 70.1 61.4 30.7 24.6 4392
500 460
750 690
1000 920
21.1 18.6 16 7.46 18.7 16.2 8.1 6.5 2865
31.8 27.9 24.1 11.3 27.6 24.3 12.3 9.8 3642
42.3 37.1 32 14.9 36.7 32.3 16.2 13 4075
24 12 6 6 NA NA 89.8 41.6 70.1 61.4 30.7 24.6 4471
Note: Amps include motor Amp loads.
Note: Please see page 60 for custom color availability - add 10% to net heater cost.
Note: Products listed in this section are custom built and subject to 100% cancellation/restocking charges.
Page 27
6300 Series Multiple Angle Cabinet Unit Heater
Control Option (Step 8 on Model Designator)
SUFFIX DESCRIPTION LIST
B3 In-Built 1-Stage Stat and Relays which are operated by an internal 24 Volt source. 79
B4* In-Built 1-Stage Stat and Relays which are operated by an internal 120 Volt source. 323
B5 In-Built 2-Stage Stat & Relays which are operated by an internal 24 Volt source. 79
B6* In-Built 2-Stage Stat and Relays which are operated by an internal 120 Volt source. 323
*Motor fusing included for units with 120V internal or external control source.
Disconnect Option “C” Circuit Breaker (Step 10 on Model Designator)
27
KW
10 501 501 319 936 501 501 867 936
12 501 501 319 936 501 501 867 936
15 501 501 501 936 841 602 867 936
16 501 501 501 936 841 602 867 936
18 501 501 501 936 841 602 867 936
20 N/A 501 501 936 841 777 867 936
24 N/A N/A 501 936 841 777 867 936
208V 240V 277V 600V 208V 340V 480V 600V
2 252 252 319 936 425 417 867 936
3 252 252 319 936 425 417 867 936
4 252 252 319 936 425 417 867 936
5 252 252 319 936 425 417 867 936
6 252 252 319 936 425 417 867 936
8 252 252 319 936 425 417 867 936
SINGLE PHASE THREE PHASE
Circuit breakers shown in shaded areas are required by NEC because unit exceeds 48 Amps, all
others listed are optional unless otherwise stated.
Disconnect Option “D” Disconnect Switch
(Step 10 on Model Designator)
KW
208V 240V 277V 600V 208V 340V 480V 600V
2 195 195 195 250 250 250 240 250
3 195 195 195 250 250 250 240 250
4 195 195 195 250 250 250 240 250
5 195 195 195 250 250 250 240 250
6 240 195 195 250 250 250 240 250
8 270 240 240 250 250 250 240 250
10 N/A 313 240 250 282 250 240 250
12 N/A N/A 313 250 282 285 240 250
15 N/A N/A N/A 250 N/A 285 240 250
16 N/A N/A N/A 250 N/A 391 240 250
18 N/A N/A N/A 250 N/A 391 240 250
20 N/A N/A N/A 250 N/A N/A 313 250
24 N/A N/A N/A 250 N/A N/A 313 250
Disconnect option is not available on heaters with circut breakers.
SINGLE PHASE THREE PHASE
Fan Switch & Motor Fusing
(Step 11 on Model Designator)
SUFFIX DESCRIPTION ADDER
S Summer Fan Switch 48
M
Motor Fusing
(when not provided by
control option)
89
Filter Option
(Step 12 on Model Designator)
SUFFIX SIZE
33" 1 46" 1 26
F
66" 2 46 79" 2 52 33" 1
W
46" 1 60 66" 2 395 79" 2 629
Qty.
REQ'D
FILTER
TYPE
Replaceable
Washable
LIST
22
59
Page 28
8500 Series Commercial Slope Top Wall Convector
28
Manufactured in U.S.A.
• Front In/Top Out or Bottom In/Top Out air pattern.
• 16 gauge steel housing powder coated with
beige nish.
• Tubular pre-wired wireway with 40 Amp capacity.
• Connection boxes for right or left hand wiring with combination 1/2” - 3/4” knockouts at back and bottom.
• Stainless steel element with Aluminum ns.
• Linear limit type thermal overload with automatic reset.
• Limited by max amp draw of 25 Amps (with no controls).
HOW TO DESIGNATE A MODEL:
85 2 5 125 H B
Series Number
Cabinet Size
1=10”H x 3”D 2=14“H x 5”D 3=20”H x 5”D
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7
Watts per Foot
Unit Length (feet)
2, 3, 4, 5, 6, 7, 8, 9, 0 (enter 0 for 10’)
Selectable in 1 watt increments up to max per model series
Voltage
E = 120V F = 208V G = 277V H=240V
8510= 250 max 8520=500 max 8530=750 max
Air Flow
DST1
B=Bottom in F=Front in
• Pencil proof louver design.
• Custom colors available, consult factory. Note: Not for residential applications. Note: Disconnect limits amperage to 20 Amps.
Standard Models
Factory Installed Options
(see control option chart)
blank=none T1 or T2=Thermostat
R1, R2, or R9=Relay DS=Disconnect
HEATER
LENGTH
2’
3’
4’
5’
6’
7’
8’
8510 SERIES 8520 SERIES 8530 SERIES
WATTS
per
FOOT
100-250
333-750 N/A 626 756
100-250
333-750 N/A 717 866
100-250
333-750 N/A 819 1001
100-250
333-750 N/A 908 1100
100-250
333-750 N/A 999 1208
100-250
333-750 N/A 1098 1330
100-250
333-750 N/A 1208 1463
3” Depth x 10” Height
Max watts per foot = 250
MODEL LIST MODEL LIST MODEL LIST
516
8512
592
8513
683
8514
753
8515
825
8516
906
8517
998
8518
5” Depth x 14” Height
Max watts per foot = 500
8522
8523
8524
8525
8526
8527
8528
565
652
753
827
906
998
1098
5” Depth x 20” Heigh
Max watts per foot = 750
688
8532
787
8533
907
8534
1001
8535
1100
8536
1208
8537
1330
8538
9’
10’
100-250
8519
333-750 N/A 1329 1605
100-250
8510
333-750 N/A 1460 1765
1098
1208
8529
8520
1208
8539
1329
8530
Note: All models qualify for international use Note: Products listed in this section are custom built and subject to 100% cancellation/restocking charges.
1463
1605
Page 29
8500 Series Commercial Slope Top Wall Convector
Product Specications
CABINET:
Rugged 16 gauge front cover with discharge louvers in sloped top design. Pencil proof louver design for
sloped outlet and front inlet grill. The nish shall be durable powder coated paint. Air ow available as
bottom in - top out, or front in - top out.
ELEMENT:
All steel high mass element construction with Nickel-Chromium resistance wire embedded in compacted
efcient dielectric to ensure proper heat transfer. Aluminum ns mechanically bonded to steel tube allows
for increased surface area and even heat transfer.
LIMIT CONTROLS:
Automatic reset hydraulic thermal overload covers full length of heating element and shuts down heater when safe operating temperatures are exceeded.
WIRING:
Connection boxes in either end with ½ inch to ¾ inch knockouts at back and bottom. Tubular prewired wire way with 40 Amp capacity.
CONTROLS:
Optional built in tamper resistant thermostat and disconnect is adjustable through top outlet louver.
29
MOUNTING:
Heater shall be surface mounted to wall or mullion. Bottom inlet units must be mounted a minimum of 4
inches above nished oor front inlet.
Voltage & Wattage Specication
Voltage Standard Wattages Per Foot Heater Lengths
120-277 100,125,150,165,187,200,250 2’ through 10’
In-Built Control Options
SUFFIX DESCRIPTION LIST
In-Built Tamper Proof, Single Pole, Bimetal Thermostat - 0°-110°F temp. range, 25
T1
T2
DS Double Pole Disconnect Switch, 20 Amp 150
Note: Due to size limitations, 8510 series convectors can only have thermostats as In-Built control options.
SUFFIX DESCRIPTION LIST
In-Built Tamper Proof, Double Pole, Bimetal Thermostat - 0°-110°F temp. range,
Amp
25 Amp
102
132
Mounting/Air Flow Options
FRONT IN
TOP OUT
BOTTOM IN
TOP OUT
R1 DPST Relay, 30 Amps, up to 277V, 120V coil 145
R2 SPST Relay, 18 Amps @ 277V (max), 24V coil 145
24V Transformer and SPST Relay, 22 Amps @240V, 18 Amps @ 277V (max), 24V
R9
(cannot be used in conjunction with T2 option)
coil
159
Page 30
30
8800 Series Institutional Wall Convector
Manufactured in U.S.A.
• Single phase heaters available in all common voltages from 120V to 600V.
• 11 gauge perforated steel housing powder coated with textured ivory
nish.
• Tamper proof left side control panel houses built-in single pole thermostat
- range 40OF-110OF and disconnect switch. Thermostat on 120V-277V units is line voltage and low voltage (24V) on 346V-600V units.
• Linear limit type thermal overload with automatic reset.
• Tamper proof fasteners
• Stainless steel element with Aluminum ns.
Note: Not for residential applications.
Standard Models
UPC#
686334
899000 E8801050 899062 F8801050 208 2.404 899123 H8801050 240 2.083 899185 G8801050 277 1.805 899246 L8801050 346 1.445 899307 P8801050 480 1.042 899369 U8801050 600 0.833 899017 E8802075 899079 F8802075 208 3.606 899130 H8802075 240 3.125 899192 G8802075 277 2.708 899253 L8802075 346 2.168 899314 P8802075 480 1.563 899376 U8802075 600 1.25 899024 E8803100 899086 F8803100 208 4.808 899147 H8803100 240 4.167 899208 G8803100 277 3.610 899260 L8803100 346 2.890 899321 P8803100 480 2.083 899383 U8803100 600 1.667 899031 E8804125 899093 F8804125 208 6.010 899154 H8804125 240 5.208 899215 G8804125 277 4.513 899277 L8804125 346 3.613 899338 P8804125 480 2.604 899390 U8804125 600 2.083 899048 E8805150 899109 F8805150 208 7.212 899161 H8805150 240 6.25 899222 G8805150 277 5.415 899284 L8805150 346 4.335 899345 P8805150 480 3.125 899406 U8805150 600 2.5 899055 E8806200 899116 F8806200 208 9.615 899178 H8806200 240 8.333 899239 G8806200 277 7.220 899291 L8806200 346 5.780 899352 P8806200 480 4.167 899413 U8806200 600 3.333
MODEL WAT TS BTU’S VOLTS AMPS
120 4.167
500 1706
120 6.25
750 2560
120 8.333
1000 3413
120 10.417
1250 4266
120 12.5
1500 5120
120 16.667
2000 6826
LENGTH
(IN.)
18 2333
28 2657
36 2970
48 3337
60 3618
72 4017
LIST
International Models
UPC#
686334 984140 M8801050i
984157 H8801050i 240 2.1 984164 M8802075i 984171 H8802075i 240 3.1 984188 M8803100i 984195 H8803100i 240 4.2 984201 M8804125i 984218 H8804125i 240 5.2 984225 M8805150i 984232 H8805150i 240 6.3 984249 M8806200i 984250 H8806200i 240 8.3
MODEL WATTS BTU’S VOLTS AMPS
500 1706
750 2560
1000 3413
1250 4266
1500 5120
2000 6826
220 2.3
220 3.4
220 4.5
220 5.7
220 6.8
220 9.1
LENGTH
(IN.)
18 2333
28 2657
36 2970
48 3337
60 3618
72 4017
LIST
Page 31
HOW TO DESIGNATE A MODEL:
Element Voltage
8800 Series Institutional Wall Convector
Product Specications
CABINET:
Institutional enclosure 11 gauge perforated steel with sloped top design. Heavy duty end caps welded to the enclosure. Control compartment for housing thermostat and disconnect switch is accessible by use of
security type fastener. The entire enclosure is protected by epoxy powder coated paint nish.
ELEMENT:
All steel high mass element construction with Nickel-Chromium resistance wire embedded in compacted
efcient dielectric to ensure proper heat transfer. Aluminum ns mechanically bonded to steel tube allows
for increased surface area and even heat transfer.
LIMIT CONTROLS:
Automatic reset hydraulic thermal overload covers full length of heating element and shuts down heater when safe operating temperatures are exceeded.
WIRING:
Wiring connections shall be made in left end of cabinet enclosure. Wiring must enter into control enclosure behind perforated steel grill.
31
CONTROLS:
All controls are accessible only through control enclosure door. Security type fasteners restrict access to controls. Built in thermostat and disconnect switch with manual adjustment are located in control enclosure.
H 880 3 100
Series Number
L=346 P=480 U=600
E=120 F=208 G=277 H=240
Unit Length
1=18” 2=28” 3=36”
4=48” 5=60” 6=72”
Unit Wattage
050=500 075=750 100=1000
125=1250 150=1500 200=2000
left side view
5.00”
ACCESS DOOR
18.00” NOTE: Allow 12 inch clearance on left end of unit and 4” to the floor.
FLOOR
4.00” Minimum
Optional In-Built Controls
SUFFIX DESCRIPTION LIST
T2 Tamperproof, Hydraulic, Double pole In-Built thermostat range 40°-110°F, 25 Amp 134
24V* 24 Volt In-Built single pole thermostat for 120V 208V, 240V & 277V models. 162
*Not available on international models
Page 32
32
HOW TO DESIGNATE A MODEL:
M41
4100 Series Recessed Commercial Wall Convector
25 F 48
1000
T
Manufactured in U.S.A.
• Front In / Front Out air pattern
• 16 gauge steel housing powder coated with
textured beige nish.
• Tubular pre-wired wireway with 40 Amp capacity.
• Connection boxes for right or left hand wiring with combination 1/2”-3/4” knockouts at back and bottom.
• Steel heating element with steel ns.
• Linear limit thermal overload with automatic reset.
M4125 Dimensions - Cabinet Sizes 4” Deep x 11” High
LENGTH (Inches) WEIGHT (Lbs.)
24 20
36 33 818
48 39 949
60 49 1077
Series Number
Cabinet Size
25=11”H x 4”D 45=20”H x 5”D
Voltage/Phase
F=208V, 1 Phase G=277V, 1 Phase
H=240V, 1 Phase J=208V, 3 Phase
K=240V, 3 Phase
24, 36, 48, 60, or 72
Unit Length (Inches)
• Recess trim frame included.
• Custom colors available, consult factory. Note: Not for residential applications.
WATTS per FOOT
AVAILABLE
187 250 333
VOLTS AVAILABLE PH
208 240 277
Total Wattage
1
Blank=None
Control Option
(See control option chart)
T or T2=Thermostat R, R2, or R9=Relay
LIST
708
72 56 1198
LENGTH
(Inches)
WEIGHT
(Lbs.)
24 45
36 53 929 36 60 1072
48 63 1 1126 48 71 1 1306
60 77 1368 60 87 1591
72 92
24 47
36 57 997 36 60 1072
48 67 1 1217 48 71 3 1306
60 82 1473 60 87 1591
72 100 1791 72 106 1919
WATTS per FOOT
AVAILABLE
M4145 Dimensions - Cabinet Sizes 5” Deep x 20” High
187 250 333
500 666
VOLTS
AVAILABLE
208 240 277
208 240 277
LIST
PH
763 24 49
1646
775
LENGTH
(Inches)
72 106
24 49
WEIGHT
(Lbs.)
WATTS per FOOT
AVAILABLE
750
500 666 750
VOLTS
AVAILABLE
208 240 277
208 240
PH
LIST
873
1917
873
Note: Products listed in this section are custom built and subject to 100% cancellation/restocking charges.
Note: Please see page 60 for custom color availability - add 10% to net heater cost.
Page 33
4100 Series Recessed Commercial Wall Convector
CABINET:
4100 series casing shall be of square design with front inlet and outlet grills suitable for
recess installation. The cabinet is fabricated from 16 gauge cold rolled steel and nished
with powder coated baked enamel. Junction boxes are available for left or right wiring and connected by pre-wired 40 Amp capacity wireway.
ELEMENT:
All steel high mass element construction with Nickel-Chromium resistance wire embedded
in compacted efcient dielectric to ensure proper heat transfer. Aluminum ns mechanically
bonded to steel tube allows for increased surface area and even heat transfer.
LIMIT CONTROLS:
Automatic reset hydraulic thermal overload covers full length of heating element and shuts down heater when safe operating temperatures are exceeded.
WIRING:
Wiring connections shall be made in left end of cabinet enclosure. Wiring must enter into control enclosure behind perforated steel grill.
33
CONTROLS:
All controls are accessible only through control enclosure door. Security type fasteners restrict access to controls. Built in thermostat with manual adjustment are located in control enclosure.
In-Built Control Options for Single Phase Units
SUFFIX DESCRIPTION LIST
T In-Built Tamper Proof, Single Pole, Hydraulic Thermostat - 40°-110°F temp. range, 25 Amps 106
T2 In-Built Tamper Proof, Double Pole, Hydraulic Thermostat - 40°-110°F temp. range, 25 Amps 131
R DPST Relay, 30 Amps, up to 277V, 120V coil 139
R2 SPST Relay, 18 Amps @ 277V (max), 24V coil 147
R9 24V Transformer and SPST Relay, 22 Amps @24V, 18 Amps @ 277V (max), 24V coil 175
Note: No In-Built control options for 3 phase models.
12” Control Section
UNIT LENGTH MODEL 4125 LIST MODEL 4145 LIST
12” MSE4120-12 81 MSE4140-12 131
Note: Control section required when relay is ordered.
Solid Back Panel
UNIT LENGTH MODEL 4125 LIST MODEL 4145 LIST
24” MS4122 66 MS4142 106
36” MS4123 86 MS4143 11 7
48” MS4124 112 MS4144 179
60” MS4125 136 MS4145 223
72” MS4126 159 MS4146 259
Page 34
34
3000 Series Fan Forced Ceiling Heater
WHITE
Manufactured in U.S.A.
UPC#
686334
948821 E3035DWBW 750 or 1500 5120 120 13 948838 E3038DWBW 900 or 1800 6143 120 15 948883 H3032DWBW 750 or 1000 - 1500 or 2000 6826 208 / 240 8 948906 G3032DWBW 2000 6826 277 7
MODEL
Selectable Wattages, Back Cans, And Power Disconnects
• Wattage selectable at time of installation - models shipped wired to highest Wattage
Fan purge circuit (has 2 wire control circuit for use with remote wall thermostat)
• Models may not be used with remote double pole thermostat
• Drywall depth embossments on back can
• Powder coated 18 gauge steel front
• Manual reset thermal limit
• Steel block n element
• Propeller style fan blade - 1060 RPM / 100 CFM
• Weight 6 lbs.
• Optional eld installed control voltage relays available
• Rough in dimensions - 9 1/4” Wide - 12 1/8” High - 3 5/8” Deep
• Grill dimensions: 9 25/32” Wide - 13” High
3380 Series Commercial Fan Forced Ceiling Heater
Product Specications
Standard Models
SELECTABLE
INSTALLATION WATTAGE
MAX
BTU'S
VOLTS
MAX
AMPS
Field Installed Accessories
UPC#
686334
996846 30R 24 VOLT RELAY 996853 30R2 120 VOLT RELAY 951500 30R8 208/240 VOLT RELAY 951494 30R7 277 VOLT RELAY 996976 303EX8RW 1" EXTENDER 39 996969 303EX16RW 2" EXTENDER 40 996952 303EX32RW 460033 TB3000 T-BAR FRAME 58
MODEL DESCRIPTION LIST
4" SURFACE MOUNT FRAME
LIST
254
35
37
46
The heaters are be constructed of a heavy gauge steel housing. The rough-
in dimensions are 19-3/16” wide x 4” deep. The nish shall be baked-on
powder coat in Ceiling White color. The units shall be available in ratings from 1500 through 4800 Watts with an optional factory installed single pole thermostat.
The heaters have a low speed 600-RPM motor, which drives a vane axial
blower to deliver a quite 175 CFM’s of down ow air. The heating element shall be of the block nned type with large, parallel steel ns for quick heat
transfer. Unit shall have as standard, a manual reset capillary type limit control, for added safety. Unit weight 22 pounds.
Features & Standard Models
Recess, Surface, Or
“T” Bar Mounting
Fan purge circuit (has 2 wire control circuit for use with remote wall thermostat)
• Disconnect switch
• White powder coated 18 gauge steel grill
• Manual reset thermal limit
• Steel block n element
• Vane axial fan blade:
1.5KW - 4.0KW units: 700 RPM motor; 175 CFM 4.8KW units: 900 RPM motor; 200 CFM
• Rough in dimensions:
14 3/16” wide x 19 5/16” high x 4” deep
• Grill dimensions:
15 3/8” wide x 20 9/64” high
• Optional factory installed tamper resistant thermostat
UPC#
686334 366489 E3383D-RP 1.5 5120 120
366298 F3386D-RP 4.0 13600 208 19.2 72 °F 619 366304 F3387D-RP 4.8 16382 208 23.1 76 °F 697 366342 HF3384D-RP 2.0 / 1.5 6826/5120 240/208 8.3/7.2 36 °F 541 366359 HF3385D-RP 3.0 / 2.3 10200/7679 240/208 12.5/10.8 54 °F 366366 HF3386D-RP 4.0 / 3.0 13600/10200 240/208 16.8/14.4 72 °F 366373 H3387D-RP 4.8 16382 240 20 76 °F 696 366502 G3383D-RP 1.5 5120 277 5.4 27 °F 589 366410 G3384D-RP 2.0 6826 277 7.2 36 °F 617 366427 G3385D-RP 3.0 10200 277 10.8 54 °F 366434 G3386D-RP 4.0 13600 277 14.4 72 °F 366441 G3387D-RP 4.8 16382 277 17.3 76 °F 772
470889 M3384D-RPi 1680 5734 470896 M3385D-RPi 2520 8600 11.5 50 °F 619 470902 M3386D-RPi 4032 13761 18.3 72 °F 697
MODEL KW BTU’S VOLTS PH AMPS
Manufactured in U.S.A.
International Models
220 1
12.5 27 °F 589
1
7.6 30 °F 589
TEMP
RISE
LIST
617
697
Accessories
UPC 686334 377850 BOX3310 Additional Back Can 10 lbs 96 381109 3380EX33 Surface Mounting Adapter 1 lb 85 460026 TB3380 2X2 T-Bar Mounting Kit 7 lbs 57
Thermostat- Add sufx T to model
MODEL DESCRIPTION WT. LIST
Factory installed single pole, positive off. Range-60° F-105° F
111
Page 35
3480 Series Commercial Fan Forced Recessed Mounted Ceiling Heater
*
Manufactured in U.S.A.
Notes
Optional controls must be factory installed. Field installation is not acceptable and violates Listing and factory warranty.
Wall mounted control panels may control multiple units but cannot be used if in-built controls are selected.
480V units include 24V transformer and relay as standard (A1) ­only TS option control section can be added. Depth dimension of all 480V models is 10-7/8”
Degree F air rise is measured at 710 F.P.M. and 425 CFM. Throw designed for 8 to 12 foot ceilings. db RE 10
Unit Weight: 50 lbs.
Recommended Remote Thermostats: Line Voltage: Single Phase 208-240V ET5DS Single Phase 277V ET5SS Three Phase TW1512
Low Voltage: UT1001
-12
Watt=63.9
Product Specications
Contractor shall supply and install heavy duty ceiling mounted forced air electric heater(s) of the wattage, voltage and phase as indicated on the plans. The heater shall be so designed to provide an even distribution of heated air to the space to be heated by drawing return air in the periphery of the heater, across and through the element and be discharged from the center section of the heater by
means of an electric motor and axial ow fan blade.
Heaters shall be recessed type and mounted ush with the nished
ceiling. The return grille assembly shall be constructed of a one piece heavy gauge steel with 1/4” slots for return air and concentric rings for uniform air discharge. Grille assembly shall be attached to chassis by tamper-resistant (allen head) machine screws. All parts of enclosure shall be heavy gauge steel, zinc coated both sides and
nished in neutral off white powder coat paint.
Enclosure shall be constructed of 1/6” x 3/8” rounded edge horizontal steel louvers which shall be spaced for maximum opening of 5/16”. Louvers shall be welded at every intersection to evenly spaced 1/8” diameter vertical members. Discharge grille to have concentric rings for uniform air discharge. Grille assembly shall be attached to chassis by tamper-resistant (allen head) machine screws. All part of enclosure shall be heavy gauge steel, Zinc coated both
sides and nished in neutral off white colored powder coat nish.
Motor shall be permanent lubricated, unit bearing, totally enclosed, impedance protection. Motors shall operate at no more than 1300 RPM and shall be same voltage as the heater.
Heaters shall have a rating of 425 CFM at 710 F.P.M. with a maximum temperature rise of 44°F and 63.9 DB RE 1012 Watt.
Element assemblies shall consist of two or three corrosion resistant steel sheathed type elements mechanically bonded to
common corrosion resistant steel ns. Each sheathed element shall
consist of helically coiled Nickel Chromium alloy resistant wire completely embedded in and surrounded by magnesium oxide, enclosed and wedged into corrosion resistant steel sheaths. Elements shall have 2” cold conductor pins extending into sheath and shall have a density of no more than 60 Watts per inch.
Heaters shall be equipped with a “manual reset” thermal overload which disconnects elements and motor in the event normal operating temperatures are exceeded. For safety, if opened due to abnormal temperature, thermal overload shall remain open until manually reset. Automatic reset thermal overloads which allow the element to continue to cycle under abnormal conditions will not be accepted. Heaters shall be ETL listed.
Features
• White powder coated 20 gauge grill.
• 208V, 240V, & 277V units have manual reset thermal limit.
• 480V units have manual reset thermal limit, 24V control transformer,
and 24V relay (A1 sufx).
• Enclosed steel n sheath element.
• Rough in dimensions: 23-1/16” sq. x 9-1/8” deep.
Standard Models
UPC#
686344 367653 F3482
367660 G3482 277 7.2 318471 P3482A1 480 4.2 1460 470186 J3482 470209 K3482 240 4.8 470247 Y3482A1 480 2.4 1557 367684 F3483
367691 G3483 277 10.8 318488 P3483A1 480 6.3 1476 470193 J3483 470216 K3483 240 7.2 470254 Y3483A1 480 3.6 1573 367714 F3484
367721 G3484 277 14.4 318501 P3484A1 480 8.3 1490 367745 J3484 367752 K3484 240 9.7 318587 Y3484A1 480 4.8 1601 367769 F3485
367776 G3485 277 18.1 318549 P3485A1 480 10.4 1665 367790 J3485 367806 K3485 240 12.1 318402 Y3485A1 480 6.1 1755 366106 PT3480 Recess Frame - Weight 5 lbs. 142
470971 M3482T2i 470988 N3482T2i 240 8.3 470995 M3483T2i 471008 N3483T2i 240 12.5 471015 M3484T2i 471022 N3484T2i 240 16.7
*Optional Louver Outlet - $70 Adder
MODEL KW BTU’S VOLTS PH AMPS
208
2 6826
2 6826
3
10200
3
4
13600
4
5
17000
5
International Models
2 6826
3 10200
4 13600
208
208
208
208
208
208
208
220
220 13.6
220 18.2
1
3
1
3
1
3
1
3
1
9.6
5.6
14.4
8.3
19.2
11.1
24.1
13.9
9.1
TEMP
LIST
RISE
1334367677 H3482 240 8.3
15 °F
1431
15 °F
1350367707 H3483 240 12.5
22 °F
1448
1366367738 H3484 240 16.8
30 °F
1475
1532367783 H3485 240 20.8
37 °F
1626
15 °F 1334
22 °F 1350
30 °F 1366
Factory Installed Control Sections
SUFFIX DESCRIPTION LIST
A1 Transformer with 24V Secondary and 24V Relay 127
S Disconnect Switch 158
TA1S Thermostat / Transformer / Disconnect Switch 371
Single Pole Thermostat and Transformer with 24V Secondary and 24V
TA1
A1S Transformer with 24V Secondary and 24V Relay and Disconnect Switch 287
T2 Double Pole Thermostat 126
T2S Double Pole Thermostat and Disconnect Switch 281
R Relay Control Voltage Same as Heater (control voltage eld supplied) 78 R1 Relay 24V Control Voltage (control voltage eld supplied) 127 R2 Relay 120V Control Voltage (control voltage eld supplied) 117
T Single Pole (480V only) 95
L Factory installed adjustable louver diffuser option. 91
Relay
231
Product Dimensions
35
Page 36
3470 Series Commercial Fan Forced Surface Mounted Ceiling Heater
36
Product Specications
Contractor shall supply and install heavy duty ceiling mounted forced air electric heater(s) of the wattage, voltage and phase as indicated on the plans. The heater shall so be designed to provide an even distribution of heated air to the space to be heated by drawing return air in the periphery of the heater, across and through the element and be discharged from the center section of the heater by mean of an electric
motor and axial ow fan blade.
Motor: Motor shall be permanent lubricated, unit bearing, totally enclosed shaded pole type with impedance protection. Motors shall operate at no more than 1300 RPM and shall be same voltage as the heater.
Performance: Heaters shall have a rating of 425 CFM at 710 F.P.M. with a maximum temperature rise of 44°F and 63.9 DB RE 1012 Watt.
Element: Element assemblies shall consist of two or three corrosion resistant steel sheathed type elements mechanically bonded to common corrosion resistant
steel ns. Each sheathed element shall consist of helically coiled Nickel Chromium
alloy resistant wire completely embedded in and surrounded by Magnesium Oxide, enclosed and wedged into corrosion resistant steel sheaths. Elements shall have 2” cold conductor pins extending into sheath and shall have a density of no more than 60 watts per inch.
Thermal Overload: Heaters shall be equipped with a “manual reset” thermal overload which disconnects elements and motor in the event normal operating temperatures are exceeded. For safety, if opened due to abnormal temperature, thermal overload shall remain open until manually reset. Automatic reset thermal overloads which allow the element to continue to cycle under abnormal conditions will not be accepted.
Approval: Heaters shall be ETL listed. Commercial and Institutional Applications: Use in - vestibules, entrance
ways, lobbies, rest rooms and small ofce and guard building applications.
Standard Models
9.6
5.6
14.4
8.3
19.2
11.1
24.1
13.9
9.1
TEMP
LIST
RISE
1334367530 H3472 240 8.3
15 °F
1431
1350367561 H3473 240 12.5
22 °F
1463
1366367592 H3474 240 16.8
30 °F
1475
1532367639 H3475 240 20.8
37 °F
1626
15 °F 1334
22 °F 1366
30 °F 1366
UPC# 686334 367516 F3472
367523 G3472 277 7.2 324335 P3472A1 480 4.2 1460 470155 J3472 470162 K3472 240 4.8 470223 Y3472A1 480 2.4 1557 367547 F3473
367554 G3473 277 10.8 324342 P3473A1 480 6.3 1476 323864 J3473 470179 K3473 240 7.2 470230 Y3473A1 480 3.6 1587 367578 F3474
367585 G3474 277 14.4 324359 P3474A1 480 8.3 1490 367608 J3474 208 367837 K3474 240 9.7 324366 Y3474A1 480 4.8 1601 367615 F3475
367622 G3475 277 18.1 324373 P3475A1 480 10.4 1665 367646 J3475 208 367844 K3475 240 12.1 324380 Y3475A1 480 6.1 1755
470919 M3472T2i 470926 N3472T2i 240 8.3 470933 M3473T2i 470940 N3473T2i 240 12.5 470957 M3474T2i 470964 N3474T2i 240 16.7
*Optional Adjustable Louver Diffuser - $91 Adder
MODEL KW BTU’S VOLTS PH AMPS
208
2 6826
2 6826
3 10200
3 10200
4 13600
5 17000
International Models
2 6826
3 10200
4 13600
208
208
208
208
208
220
220 13.6
220 18.2
1
3
1
3
1
3
1
3
1
Factory Installed Control Sections
SUFFIX UNITS DESCRIPTION LIST
TS 1-Phase
TA1S 3-Phase
A1S
1 or 3
Phase
T Single Pole (480V only) 95
Single Pole Thermostat - range 40°-110°F and
Disconnect Switch
Single Pole Thermostat - range 40°-110°F & Transformer with 24V Secondary and 24V Relay & Disconnect Switch
Transformer with 24V Secondary and 24V Relay and
Disconnect Switch
265
277
283
*
Manufactured in U.S.A.
Product Dimensions
Wall Mounted Control Panels
UPC#
686334
605700 AF3401-24 208
605854 AG3401-24 277
605748 AF3402-24 208
605847 AG3402-24 277
605731 AF3403-24 208
605830 AG3403-24 277
MODEL VOLTS CONTACTORS
1 @ 35 AMPS
2 @ 35 AMPS
3 @ 35 AMPS
BOX
SIZE
1 2 " x 1 2 "
x 4 1/2"
1 5 " x 1 5 "
x 4 1/2"
1 8 " x 1 8 "
x 4 1/2"
LIST
360605793 AH3401-24 240
450605786 AH3402-24 240
600605779 AH3403-24 240
Notes
Optional controls must be factory installed. Field installation is not acceptable and violates Listing and factory warranty.
Factory installed control sections add 2-5/16” to the height of the unit.
Wall mounted control panels may control multiple units but cannot be used if In-Built controls are selected.
480V units include 24V transformer and relay as standard (A1)
- only TS option control section can be added. Depth dimension of all 480V models is 10-7/8”
Degree F air rise is measured at 710 F.P.M. and 425 CFM. Throw designed for 8 to 12 foot ceilings. db RE 10
Unit weight: 32 lbs.
Recommended Remote Thermostats: Line Voltage: Single Phase 208-240V ET5DS Single Phase 277V ET5SS Three Phase TW1512
Low Voltage: UT1001
-12
Watt=63.9
Page 37
CP & RCP Series Radiant Ceiling Panel Heaters
Product Description
For Surface Or Recessed Installation, Radiant Ceiling Panels radiate energy like the solar radiation which warms us, heats objects, not the air. With no moving parts, these heating panels create gentle warmth and toasty comfort.
Radiant Ceiling Panels provide a low surface temperature and broad heat distribution. Clean, gentle comfortable heat that is ideal for offsetting perimeter heat loss or neutralizing downdrafts
over glass. These versatile and exible panels may be used
virtually anywhere in homes, schools, hospitals, motels and a broad variety of other commercial or industrial installations.
Product Specications
Construction:
Radiant Ceiling Panels shall be made of highest quality steel casing.
Front panel shall be painted with textured powder coated nish. Electric Resistance element is xed between dielectric material and
insulation. Two inches of insulation is compressed to one inch by back
panel to minimize upward heat loss and radiant efciency. Radiant panels shall have 36” pre-wired exible cable for easy installation and
wiring connections.
Installation:
CP Series shall be designated as 2x2 or 2x4 size. All panels are 1”
thick. The size shall be nominal dimension to be manufactured to t drop ceiling systems. Standard units will t regular “T” Bar frame.
For regular or trim line or other frame sizes, special construction is required. RCP Series shall be used in recess mounting applications. RCP Series shall be 2” less in width to recess between nominal 24” center ceiling joists. RCP Series shall be complete with recess frame
for nished construction.
Accessories:
Surface mounting frames shall be optional for surface mounting the CP
Series, and are Aluminum mill nish. Frames can be painted white to
match panel.
Options:
Silk-screening the exposed surface to match ceiling tiles is available, as well as silicone sealed metal parts for high humidity applications.
Manufactured in U.S.A.
37
CP Series - “T” Bar & Surface Mounted RCP Series - Frame in Ceiling Mounted
UPC#
686334
458719 CP805
458733 CP705 2 277 458740 CP807
458764 CP707 3 277
458771 CP802
458795 CP702 .9 277 458801 CP803
458825 CP703 1 277 459105 SF400 Surface Frame for 2’ x 4’ Panels (CP only) 10 lb. 182 459099 SF200 Surface Frame for 2’ x 2’ Panels 6 lb. 144
MODEL WATTS BTU's AMPS VOLTS WT LIST
Dimensions: 2' x 4' (Nominal) x 1"
500 1707
750 2560
Dimensions: 2' x 2' (Nominal) x 1"
250 853
375 1280
2 208
20 lb. 412458726 CP125 4.2/2.1 120/240
4 208
20 lb. 425458757 CP127 6.3/3.1 120/240
1 208
13 lb. 270458788 CP122 2.1/1.0 120/240
2 208
13 lb. 327458818 CP123 3.1/1.6 120/240
UPC#
686334
458832 RCP805
458856 RCP705 2 277 458863 RCP807
458887 RCP707 3 277
458894 RCP802
458917 RCP702 .9 277 458924 RCP803
458948 RCP703 1 277
MODEL WATTS BTU's AMPS VOLTS WT LIST
Dimensions: 2' x 4' (Including Recessing Frame)
2 208
500 1707
4 208
750 2560
Dimensions: 2' x 2' (Including Recessing Frame)
1 208
250 853
2 208
375 1280
International Models
UPC#
686334
MODEL WATTS BTU's AMPS VOLTS WT LIST
Dimensions: 2' x 4' (Nominal) x 1"
471039 CP2205i 420 1434 1.9 220 471046 CP125i 500 1707 4.2/4.1 120/240 471053 CP2207i 630 2150 2.9 220 471060 CP127i 750 2560 6.3/3.1 120/240
Dimensions: 2' x 2' (Nominal) x 1"
471077 CP2202i 210 717 0.95
471084 CP122i 250 853
2.1/1.0 120/240
0.9 277
471091 CP2203i 315 1075 1.4 220
471107 CP123i 375 1280
3.1/1.6 120/240
1.4 277
20 412
20 425
13 270
13 327
UPC#
686334
MODEL WATTS BTU's AMPS VOLTS WT LIST
Dimensions: 2' x 4' (Including Recessing Frame)
471114 RCP2205i 420 1434 1.9 220 471121 RCP125i 500 1707 4.2/4.1 120/240 471138 RCP2207i 630 2150 2.9 220 471145 RCP127i 750 2560 6.3/3.1 120/240
Dimensions: 2' x 2' (Including Recessing Frame)
471152 RCP2202i 210 717 0.95 220 471169 RCP122i 250 853 2.1/1.0 120/240 471176 RCP2203i 315 1075 1.4 220 471183 RCP123i 375 1280 3.1/1.6 120/240
30 lb. 585458849 RCP125 4.2/2.1 120/240
30 lb. 646458870 RCP127 6.3/3.1 120/240
19 lb. 393458900 RCP122 2.1/1.0 120/240
19 lb. 493458931 RCP123 3.1/1.6 120/240
585
30
646
393
19
493
Page 38
38
CVX Series Radiant Cove Ceiling Heater
Manufactured in U.S.A.
Product Description
Cove Heaters have a subtly contoured concave surface with a saw-tooth prole. The concave parabolic face plate
performs a two-fold function: (1) it focuses the infrared rays and (2) directs the heat downward along cold perimeters and toward the center of the room. The sawtooth surface design increases the radiating surface area by 45%, thereby increasing the comfort level of the room faster and insuring more rapid recovery from heat losses.
Product Specications
Furnish and install Electric Cove Heaters where specied. The heaters shall be constructed of .962” thick Aluminum. The heater surface shall be concave in contour and saw-tooth in prole. The nish shall be of powder coat white nish.
The heaters shall be available in ratings from 450 through 1250 Watts, at 120, 240, 208 and 277 Volts. The heating element shall be of Nichrome wire, embedded in Magnesium Oxide powder, enclosed and sealed in Aluminum metal tubing. The heater shall be listed by ETL and the elements shall be supplied with a one year limited warranty.
Standard Models
UPC#
686334
457583 CV4512X 450 457590 CV45X 450 2 240 457606 CV45YX 450 2.0 208 457613 CV4527X 450 2 277 457620 CV6012X 600 457637 CV60X 600 3 240 457644 CV60YX 600 3 208 457651 CV6027X 600 2 277 457668 CV7512X 750 457675 CV75X 750 3 240 457682 CV75YX 750 3.6 208 457699 CV7527X 750 3 277 457705 CV9012X 900 457712 CV90X 900 4 240 457729 CV90YX 900 4 208 457736 CV9027X 900 3 277 457743 CV10012X 1000 457750 CV100X 1000 4 240 457767 CV100YX 1000 5 208 457774 CV10027X 1000 4 277 457781 CV11012X 1100 457798 CV110X 1100 5 240 457804 CV110YX 1100 5 208 457811 CV11027X 1100 4.0 277 457828 CV12512X 1250 457835 CV125X 1250 5 240 457842 CV125YX 1250 6.0 208 457859 CV12527X 1250 5 277
471190 CV4522Xi 471206 CV45Xi 1.9 240 471213 CV6022Xi 471220 CV60Xi 2.5 240 471237 CV7522Xi 471244 CV75Xi 3.1 240 471251 CV9022Xi 471268 CV90Xi 3.8 240 471275 CV10022Xi 471282 CV100Xi 4.2 240 471299 CV11022Xi 471305 CV110Xi 4.6 240 471312 CV12522Xi 471329 CV125Xi 5.2 240
MODEL WATTS BTU's AMPS VOLTS LENGTH W T. LIST
4 120
1536
5.0 120
2048
6 120
2560
8 120
3072
8 120
3413
9 120
3754
10 120
4266
International Models
450 1536
600 2048
750 2560
900 3072
1000 3413
1100 3754
1250 4266
2.0 220
2.7 220
3.4 220
4.1 220
4.5 220
5.0 220
5.7 220
42” 7 lb. 207
60” 10 lb. 258
72” 13 lb. 285
84” 14 lb. 322
96” 17 lb. 335
108” 19 lb. 373
120” 21 lb. 412
42” 7 207
60” 10 258
72” 13 285
84” 14 322
96” 17 335
108” 19 373
120” 21 412
Accessories & Dimensions
UPC#
686334
457927 CVCBX Ceiling Bracket* 1/2 lb. 14
457866 CVB42X
457873 CVB60X 60” Blank Section 8 lb. 70
457880 CVB84X
457912 CVSP Aerosol Touch-up Paint 1 lb. 44
MODEL DESCRIPTION WT. LIST
42” Blank Section 6 lb. 48
84” Blank Section 12 lb. 94
* Order 2 for units up to 72” Order 3 for units over 72”
Page 39
3000 Series Midsized Commercial Fan Forced Wall Heater - Multiple Wattage
Features
• Wattage selectable at time of installation.
• Models shipped wired to highest wattage.
• Approved for horizontal mounting - right or left discharge.
• Fan purge circuit.
• Disconnect switch.
• Drywall depth embossments on back can.
• 18 gauge powder coated steel & extruded Aluminum front.
• Manual reset thermal limit.
• Steel block n element.
• Propeller style fan blade: 1060 RPM motor; 100 CFM.
Approved for
wall or ceiling
installation
Manufactured in U.S.A.
• Weight 6 lbs.
• Rough in dimensions: 9-1/4” Wide x 12-1/8” High x 3-5/8” Deep.
• Grill dimensions: 10” Wide x 13-1/8” High.
Standard Models
39
UPC#
686334
TAMPERPROOF IN-BUILT DOUBLE POLE THERMOSTAT (50º - 90º TEMPERATURE RANGE)
996211 E3055T2DWB 750 or 1500 5120 120 12.5 298
996228 E3058T2DWB 900 or 1800 6143 120 15.0
996259 F3052T2DWB 1000 or 2000 6826 208 8.3
945691 F30522T2DWB
996280 H3052T2DWB 750 or 1000 - 1500 or 2000 6826 208 / 240 8.3 298
945721 H30522T2DWB
996310 G3052T2DWB 2000 6826 277 7.2 302
996068 E3055TDWB 750 or 1500 5120 120 12.5 280
996075 E3058TDWB 900 or 1800 6143 120 15.0
996105 F3052TDWB 1000 or 2000 6826 208 8.3
945639 F30522TDWB
996136 H3052TDWB 750 or 1000 - 1500 or 2000 6826 208 / 240 8.3 280
945660 H30522TDWB
996167 G3052TDWB 2000 6826 277 7.2 282
MODEL SELECTABLE INSTALLATION WATTAGE
500 or 750 or 1000 or 1250
or 1500 or 1750 or 2250
500 or 750 or 1000 or 1250
or 1500 or 1750 or 2250
TAMPERPROOF IN-BUILT SINGLE POLE THERMOSTAT (50º - 90º TEMPERATURE RANGE)
500 or 750 or 1000 or 1250
or 1500 or 1750 or 2250
500 or 750 or 1000 or 1250
or 1500 or 1750 or 2250
MAX
BTU’s AMPS
7680 208 10.8 344
7680 240 9.4 342
7680 208 10.8 325
7680 240 9.4 311
VOLTS
MAX
LIST
296
282
Accessories
UPC#
686334
996945 305EX8 1” EXTENDER 39
996938 305EX16 2” EXTENDER 40
996921 305EX32 4” SURFACE MOUNT FRAME 45
Note: Please see page 60 for custom color availability - add 10% to net heater cost.
MODEL DESCRIPTION LIST
Page 40
40
3320 Series Commercial Fan Forced Wall Heater
• Disconnect switch. • Built-In tamper proof thermostat.
• Automatic fan delay circuit.
• Powder coated 18 gauge steel grill with extruded Aluminum front frame.
• Automatic reset thermal limit.
• Steel block n element.
• Vane axial fan blade: 600 RPM motor; 175 CFM
• Rough-in dimensions: 14-3/16” Wide x 19-7/16” High x 4” Deep
• Grill dimensions: 15-29/32” Wide x 20-27/32” High
Furnish and install Heavy-Duty Forced Air wall heaters, where specied. The heaters
shall be constructed of a heavy 18 gauge steel housing with an extruded Aluminum frame. The rough-in dimensions are 19-7/16” High x 14-3/16” Wide x 4” Deep. The units shall be available in ratings from 750 to 4800 Watts at 240, 208, and 277 Volts.
Manufactured in U.S.A.
Standard Models
UPC#
686334
IN-BUILT SINGLE POLE TAMPERPROOF THERMOSTAT (50º - 90º TEMPERATURE RANGE)
FOR DOUBLE POLE THERMOSTAT REPLACE “T” IN MODEL NUMBER WITH “T2” -- Add $50 382052 E3321TD-RP 750 2560 381994 E3322TD-RP 1000 3413 8.3 380881 E3323TD-RP 1500 5120 12.5 638 380935 F3326TD-RP 4000 13800 381024 F3327TD-RP 4800 16560 23 681 380942 HF3323TD-RP 1500 / 1125 5120 / 3840 380959 HF3324TD-RP 2000 / 1500 6284 / 5120 8.3 / 7.2 27 380966 HF3325TD-RP 3000 / 2250 10350 / 7763 12.5 /10.8
381031 H3327TD-RP 4800 16560 240 20 674 380980 G3323TD-RP 1500 5120 380997 G3324TD-RP 2000 6284 7.2 27 381000 G3325TD-RP 3000 10350 10.8
381048 G3327TD-RP 4800 16560 17.3 667 398077 J3326TD-RP 4000 13800 398091 J3327TD-RP 4800 16560 13.33 820 398084 K3326TD-RP 4000 13800 398107 K3327TD-RP 4800 16560 11.57 820
396424 M3324TD-RPi 3360/1680 11468/5734 396437 M3325TD-RPi 4032/2016 13761/6881 18.3/9.16
MODEL WAT TS BTU’s VOLTS AMPS
International Models
The heaters shall have a low-speed 600 RPM, 4-pole motor which drives a vane axial
blower to deliver a quiet 175 CFM of down ow air. The heating element shall be
WT.
LIST
LBS.
120
208
240 /
208
277
208
240
220
6.25
19.2 648
6.2 / 5.4
4.1 26
11.11
9.64 780
15.3/7.64
637
26
648
29380973 HF3326TD-RP 4000 / 3000 13800 / 10350 16.7/14.4
647
29381017 G3326TD-RP 4000 13800 14.4
780
30
27 648
Features
Product Specications
of the sealed tubular type with large, parallel steel ns
for quick heat transfer. Unit shall have as a standard, a thermal overload cut-off for added safety, fan delay switch and built-in tamper proof thermostat which shall be calibrated to provide a range of 55°F. to 85°F. and manual disconnect switch. Optional accessories shall include a surface and semi­recess mounting adapter. All heaters shall be listed by ETL. The heating element shall be supplied with a manufactures 1-year limited warranty.
Accessories
UPC
686334
377850 BOX 3310
378451 3320EX33
382939 3320EX16
MODEL DESCRIPTION TYPE
----- Sufx - HD
Additional Rough-in
Box
4” Surface Mounting
Frame
2” semi recess
extender
16 Gauge Steel
Heavy Duty Grill
Installed
Factory
Installed
Field
WT. lbs.
3 99
1 90
1 77
2 99
LIST
4400 Series Low Prole Commercial Fan Forced Wall Heater - With Wall Box
• Powder coated 20 gauge steel front with extruded Aluminum frame.
• Manual reset
Manufactured in U.S.A.
thermal limit.
• Finned tubular steel element.
• Propeller style fan blade - 2200 RPM/70 CFM
• Weight 9 lbs.
• Rough in dimensions:
UPC
686334 BTU’S
328326 F4420T2RP 208 2000 6826 9.6 328333 HF4475T2RP 328340 HF4410T2RP 1000 / 750 3413 / 2560 4.2 / 3.6 328357 HF4415T2RP 1500 / 1125 5120 / 3840 6.3 / 5.4 328364 HF4420T2RP 2000 / 1500 6826 / 5120 8.3 / 7.2
328371 E4475TRP 328388 E4410TRP 1000 3413 8.33 328395 E4415TRP 1500 5120 12.5 328401 F4420TRP 208 2000 6826 9.6
MODEL VOLTS WATTS
DOUBLE POLE IN-BUILT THERMOSTAT (RANGE 50º - 90º F)
SINGLE POLE IN-BUILT THERMOSTAT (RANGE 50º - 90º F)
14-1/2” Wide x 7-1/8” High x 3-1/2” Deep
• Grill dimensions:16-7/8” Wide x 8” High
• Unit not approved for ceiling mount applications.
• Unit can be positioned to allow left, right or top discharge.
Note: Please see page 60 for custom color availability - add 10% to net heater cost.
UPC
686334 LBS.
329910 4400EX8 1” SEMI RECESSING EXTENDER 2 44 329903 4400EX16 2” SEMI RECESSING EXTENDER 3 47 329897 4400EX32 4” SURFACE MOUNTING FRAME 4 49 328449 4300PB WALL PLATE ADAPTOR (OD 21.5”x12.25”) 1 32
MODEL DESCRIPTION
Standard Models
750 / 562 2560 / 1920 3.1 / 2.7
240/208
750 2560 6.25
120
Accessories
MAX
AMPS LIST
315
296
WT.
LIST
Page 41
3420 & 3450 Series Heavy-Duty Fan Forced Wall Heaters
Features
• Powder coated bar stock steel tamper proof grille, with extruded Aluminum frame and 16 gauge housing.
• In-Built double pole tamper proof thermostat with a 40°-110°F temperature range & positive off; 3 phase heaters have 3 pole thermostat for positive off position.
• Manual reset thermal limit switch.
• Corrosion resistant steel tubular element with brazed steel ns.
• Permanently lubricated, unit bearing, shaded pole motor with impedance protection.
• Propeller type fan blade:
Note: Wall box required - may be ordered early for rough in purposes.
Manufactured in U.S.A.
1400 RPM motor; 245 CFM
• Factory installed options:
- contactors (3420 & 3450 series)
- circuit breakers (3450 series)
- control transformers (3450 series)
Standard Models
HEATER WALL BOX
UPC 686334 MODEL UPC 686334 MODEL
SERIES 3420 - ROUGH-IN DIMENSIONS: 19-3/8” H x 14-1/4” W x 4-1/4” D
GRILL DIMENSIONS: 21-15/32” H x 17-7/16” W
691130 F3422T
WATTS BTU’s VOLTS PH AMPS WT.
2000 6826
208
1
9.6
HEATER
LIST
957 691178 G3422T 277 7.2 384629 J3422T 384643 K3422T 240 4.8
2000 6826
691239 F3423T 691314 H3423T 240 12.5
3000 10239
208
208
3
1
5.6
14.4
1123 1280
981 1138
691277 G3423T 277 10.8 968 1125 384636 J3423T 384650 K3423T 240 7.3 691338 F3424T
691574 Box 3420
691369 G3424T 277 14.4
3000 10239
4000 13652 691406 J3424T 208 691413 K3424T 240 9.6 691437 F3425T 691512 H3425T 240 20.8 691482 G3425T 277 18.1
5000 17065 691536 J3425T 208 691567 K3425T 240 12.0
208
208
208
3
1
3
8.3
19.2
11.1
1123 1280
41 lbs.
1001 1158691383 H3424T 240 16.7
1123 1280
24
1
3
13.9
1136 1293
1234 1391
WALL
BOX LIST
157
41
TOTAL
LIST
1114691192 H3422T 240 8.3
HEATER WALL BOX
UPC 686334 MODEL UPC 686334 MODEL
SERIES 3450 - ROUGH-IN DIMENSIONS: 23-1/16” H x 14-1/4” W x 4-1/4” D
GRILL DIMENSIONS: 25-1/32” H x 17-7/16” W
691611 F3452T
WATTS BTU’s VOLTS PH AMPS WT.
2000 6826
208
1
9.6
312295 G3452T 277 7.2 384667 J3452T 384681 K3452T 240 4.8
2000 6826
687683 F3453T
3000 10239
208
208
3
5.6
14.4
1 312288 G3453T 277 10.8 384674 J3453T 384698 K3453T 240 7.3 691789 F3454T
691918 Box 3450
3000 10239
691819 H3454T 240 16.7 311991 G3454T 277 14.4
4000 13652 691857 J3454T 208 316651 K3454T 240 9.6 312981 F3455T
208
208
208
3
8.3
19.2
1
3
11.1
10.4
1 312387 G3455T 277 18.1 691901 J3455T 208 313070 K3455T 240 12.0
5000 17065
3
13.9
Note: Please see page 60 for custom color availability - add 10% to net heater cost. Note: Products listed in this section are custom built and subject to 100% cancellation/restocking charges.
55 lbs.
LIST
WALL
BOX LIST
TOTAL
HEATER
1227
1395 1577
1242 1424691772 H3453T 240 12.5
1395 1577
181
1273 1455
1395 1577
1401 1583312134 H3455T 240 20.8
1537 1719
LIST
1409691680 H3452T 240 8.3
Page 42
42
3420 & 3450 Series Heavy-Duty Fan Forced Wall Heaters
Product Specications
Contractor shall supply and install heavy duty wall mounted forced air electric heaters of the
wattage, voltage and phase as specied. The heater shall so be designed to provide an even
distribution of heated air to the space to be heated by drawing return air in the peripheral area of the heater across and through the element which shall then be discharged from the center section of
the heater by means of an electric motor and axial ow fan blade. Heaters shall be recessed type to extend no more than 1-1/2” from the nished wall or surface mounted to extend no more than 5-3/4” from the nished wall or semi-recessed type to extend no more than 3-1/2” from nished wall or semi-recessed type to extend no more than 2-1/2” from nished wall.
ENCLOSURE: Heater front shall withstand 10.8 ft. lbs. (324 poundals) impact and 400 lbs. static force applied to an 8 sq. in. area at center grille location with less than 1/16” permanent distortion. The combination return and supply grille assembly shall be constructed of 1/16” x 3/8” rounded edge horizontal steel louvers which shall be spaced for maximum opening of 1/4”. Louvers shall be welded at every intersection to three evenly spaced 1/16” diameter vertical members and completely framed in a heavy gauge natural anodized Aluminum extrusion. Front assembly shall be attached to the chassis by hidden tamper-resistant (Allen-head) machine screws. All other parts shall be 16 gauge steel
Zinc coated, both sides nished in a high gloss or bronze colored baked powder coat nish.
MOTOR:
Motor shall be a permanently lubricated unit bearing, totally enclosed shaded pole type with impedance protection. Motors shall operate at no more than 1400 RPM and shall be same voltage as the heater. A protective shield shall surround the motor to separate return air from heated air.
PERFORMANCE:
Heaters shall have a rating of 245 CFM at 660 F.P.M. with a maximum temperature rise of 73°F.
ELEMENTS:
Element assemblies shall consist of two or three corrosion resistant steel sheathed type elements
mechanically bonded to common corrosion resistant steel ns. Each sheathed element shall consist
of helically coiled Nickel Chromium alloy resistant wire completely embedded in and surrounded by Magnesium Oxide, enclosed and wedged into corrosion resistant steel sheaths. Elements shall have 2” cold conductor pins extending into the sheath and shall have a density of no more than 60 Watts per inch.
THERMAL OVERLOAD:
Heaters shall be equipped with a “manual reset” thermal overload which disconnects elements and motor in the event normal operating temperatures are exceeded. For safety, if opened due to abnormal temperature, thermal overload shall remain open until manually reset. Automatic reset thermal overloads which allow the element to continue to cycle under abnormal conditions will not be accepted.
APPROVAL:
Heaters shall be ETL Listed.
OPTIONAL CONTROL SYSTEMS:
Heaters shall be operated from wall-mounted, line voltage, heavy-duty (tamper-proof) thermostats. Heaters with built-in, pre-wired contactors shall be operated from wall-mounted, line voltage, pilot duty (tamper-proof) thermostats. Heaters built with, pre-wired contactors (and control transformers) shall be operated from wall-mounted, pilot duty (24V) or (120V) wall-mounted tamper-proof thermostats. Heaters shall be controlled by integrally mounted thermostats. Thermostats shall be heavy-duty, hydraulic type with a range of 40°F to 80°F and with remote sensing bulb placed in the return air. Thermostats shall be electrically rated at least 125% of heater rating. Thermostats
Page 43
3420 & 3450 Series Heavy-Duty Fan Forced Wall Heaters
Product Specications
shall be heavy-duty, hydraulic type with a range of 40°F to 80°F and with remote sensing bulb placed in the return air. Thermostats shall be electrically rated at least 125% of heater rating. Thermostats shall also act as a disconnect by breaking all ungrounded conductors in the OFF position. (Thermostat control knob shall be covered by a 16 gauge tamper-proof access plate to prevent adjustment by unauthorized personnel.)
CONTACTORS:
Where required, heaters shall be equipped with heavy-duty, denite purpose contactors with ame
path separators and dust covers. Contactors shall cycle all ungrounded conductors. Contactors shall have holding coils (of the same voltage as the heater) or (120 Volts) or (24 Volts).
CONTROL TRANSFORMERS: Heater shall be equipped with a Class 2 control transformer, sealed rating of 20 VA, to supply control circuits of (24 Volts) or (120 Volts). (120 Volt secondaries not available in single phase heaters over 3 KW).
CIRCUIT BREAKERS (3450 Series Only):
Heaters shall be equipped with built-in circuit breakers in order to allow the heaters to be supplied from feeder taps. A separate switch providing a positive off for control circuits shall be included where required. Circuit breakers and control switches shall be arranged so that all line side conductors will be separately enclosed when heater front is removed for servicing so that no current carrying parts are accessible without the use of additional tools.
43
Field Installed Accessories
Units with transformers must have a contactor. A control transformer with 120V secondary is available on all 3-phase
models, 208V/240V 1-phase units up to 3KW, and up to 4 KW on 277V. All heaters must be installed with a wall box.
MODEL DESCRIPTION
Sufx - R Contactor with Coil same as heater YES YES
Sufx - R1 Contactor with 24V Coil YES YES
Sufx - R2 Contactor with 120V Coil YES YES
Sufx - C Circuit Breakers - all models NO YES 340
Sufx - A1 Control Transformers With 24V Secondary NO YES 100
Sufx - A2 Control Transformers With 120V Secondary NO YES 134
UPC#
686334
691949 3450EX34 4” Surface Mounting Sleeve 6 lb.
691932 3450EX16 2” Semi-Recessing Sleeve 4 lb.
MODEL DESCRIPTION W T. LIST
SERIES OPTIONS
3420 3450
LIST
182
101
97
691925 3450EX8 1” Semi-Recessing Sleeve 4 lb.
691604 3420EX34 4” Surface Mounting Sleeve 5 lb.
691598 3420EX16 2” Semi-Recessing Sleeve 4 lb.
691581 3420EX8 1” Semi-Recessing Sleeve 3 lb.
78
101
97
78
Page 44
44
3310 Series Fan Forced Wall Heater - Without Summer Fan Switch
Features
• Powder coated 18 gauge steel front.
• Automatic reset thermal limit.
• Vane axial fan blade: 600 RPM / 175 CFM.
• Rough in dimensions: 14-3/16” Wide x 19-15/16” High x 4” Deep.
• Grill dimensions: 15-3/8” Wide x 20-9/64” High.
• Steel block n element.
• Weight 22 lbs.
• Units with dual wattage, factory wired to highest wattage.
• Wattage selectable at time of installation on some models.
Standard Models
MODELS WITH IN-BUILT DOUBLE POLE THERMOSTAT (50º - 90º F TEMPERATURE RANGE)
IVORY WHITE
UPC 686334 326346 E3312T2RP 326483 E3312T2RPW 1000 3413
326353 E3313T2RP 326490 E3313T2RPW
326360 F3316T2RP 326506 F3316T2RPW 4000 13648 326377 F3317T2RP 326513 F3317T2RPW 4800 16380 23 509
326407 HF3315T2RP 326544 HF3315T2RPW
326414 HF3316T2RP 326551 HF3316T2RPW
326421 H3317T2RP 326568 H3317T2RPW 4800 16380 240 20.0 520 326438 G3314T2RP 326575 G3314T2RPW 2000 6826 326445 G3315T2RP 326582 G3315T2RPW 3000 10240 10.8 326452 G3316T2RP 326599 G3316T2RPW 4000 13648 14.4 326469 G3317T2RP 326605 G3317T2RPW 4800 16380 17.3 512
IVORY
MODEL
UPC
686334
WHITE
MODEL
WATTS
1500 5120 12.5
750 2560 6.25
3000 / 2250 10240
1500 / 1125 5120 6.2 / 5.4 4000 / 3000 13648 16.8 / 14.4 2000 / 1500 6826 8.3 / 7.2
MAX
BTU’s
VOLTS AMPS LIST
120
208
240 / 208
277
Manufactured in U.S.A.
8.3 488
19.2 496
12.5 / 10.8
7.2
495
496
495
MODELS WITH IN-BUILT SINGLE POLE THERMOSTAT (50º - 90º F TEMPERATURE RANGE)
382526 E3312TRP 382618 E3312TRPW 1000 3413
380652 E3313TRP 384162 E3313TRPW
379946 F3316TRP 384186 F3316TRPW 4000 13648 380300 F3317TRP 384193 F3317TRPW 4800 16380 23
380560 HF3315TRP 382229 HF3315TRPW
379984 HF3316TRP 382236 HF3316TRPW
380317 H3317TRP 382243 H3317TRPW 4800 16380 240 20.0 486 329873 G3314TRP 384261 G3314TRPW 2000 6826
328500 G3316TRP 328524 G3316TRPW 4000 13648 14.4 379179 G3317TRP 384292 G3317TRPW 4800 16380 17.3 480
MODELS WITHOUT AN IN-BUILT THERMOSTAT
326629 E3312RP 326766 E3312RPW 1000 3413
326636 E3313RP 326773 E3313RPW
328531 F3316RP 326780 F3316RPW 4000 13648 326650 F3317RP 326797 F3317RPW 4800 16380 23 455
326681 HF3315RP 326827 HF3315RPW
326698 HF3316RP 326834 HF3316RPW
326704 H3317RP 326841 H3317RPW 4800 16380 240 20.0 465 326711 G3314RP 326858 G3314RPW 2000 6826
326735 G3316RP 326872 G3316RPW 4000 13648 14.4 326742 G3317RP 326889 G3317RPW 4800 16380 17.3 457
1500 5120 12.5
750 2560 6.25
3000 / 2250 10240
1500 / 1125 5120 6.2 / 5.4 4000 / 3000 13648 16.8 / 14.4 2000 / 1500 6826 8.3 / 7.2
1500 5120 12.5
750 2560 6.25
3000 / 2250 10240
1500 / 1125 5120 6.2 / 5.4 4000 / 3000 13648 16.8 / 14.4 2000 / 1500 6826 8.3 / 7.2
120
208
240 / 208
277
120
208
240 / 208
277
8.3
19.2 463
12.5 / 10.8
7.2
8.3
19.2 442
12.5 / 10.8
7.2
455
476
463
462328494 G3315TRP 328517 G3315TRPW 3000 10240 10.8
432
442
441326728 G3315RP 326865 G3315RPW 3000 10240 10.8
Page 45
3310 Series Fan Forced Wall Heater - With Summer Fan Switch
Features
• Powder coated 18 gauge steel front.
• Automatic reset thermal limit.
Manufactured in U.S.A.
• Steel block n element.
• Weight 22 lbs.
• Vane axial fan blade: 600 RPM / 175 CFM.
• Grill dimensions: 15-3/8” Wide x 20-9/64” High.
• Rough in dimensions: 14-3/16” Wide x 19-15/16” High x 4” Deep.
• Units with dual wattage, factory wired to highest wattage.
• Wattage selectable at time of installation on some models.
Product Specications
Typical Specications: Furnish and install Electric Forced Air Heaters where specied. The heaters shall be constructed of a heavy gauge steel housing. The rough-in dimensions are 14-3/16” Wide x 19-5/16” High x 4” Deep. The nish
shall be powder coated paint in ivory or white color. The units shall be available in ratings from 750 through 4800 Watts. The heaters shall have a low speed 600 RPM
motor which drives a vane axial blower to deliver a quiet 175 CFM of down ow air. The heating element shall be of the sealed block n type with large, parallel steel ns for quick heat transfer. Unit shall have a standard thermal
overload cutoff for added safety, a fan switch for fan only operation, and is available with a single pole, or double pole built-in thermostat, or no thermostat. The in-built thermostat shall be calibrated to provide a range of 50 degrees F. to 90 degrees F. All heaters shall be listed by ETL. The heating element shall be supplied with a manufacturer’s 1 year limited warranty.
Standard Models
MODELS WITH IN-BUILT DOUBLE POLE THERMOSTAT (50º - 90ºF TEMPERATURE RANGE)
IVORY WHITE
UPC
686334 686334
326063 E3312T2SRP 326209 E3312T2SRPW 1000 3413
326070 E3313T2SRP 326216 E3313T2SRPW
326087 F3316T2SRP 326223 F3316T2SRPW 4000 13648 326094 F3317T2SRP 326230 F3317T2SRPW 4800 16380 23 521
326124 HF3315T2SRP 326261 HF3315T2SRPW
326131 HF3316T2SRP 326278 HF3316T2SRPW
326148 H3317T2SRP 326285 H3317T2SRPW 4800 16380 240 20.0 530
IVORY
UPC
WHITE
WATTS MAX BTU’s VOLTS AMPS LIST
8.3
1500 5120 12.5
750 2560 6.25
3000 / 2250 10240
1500 / 1125 5120 6.2 / 5.4 4000 / 3000 13648 16.8 / 14.4 2000 / 1500 6826 8.3 / 7.2
120
208
240 / 208
19.2 509
12.5 / 10.8
498
509
45
MODELS WITH IN-BUILT SINGLE POLE THERMOSTAT (50º - 90ºF TEMPERATURE RANGE)
382571 E3312TSRP 382595 E3312TSRPW 1000 3413
379618 E3313TSRP 384018 E3313TSRPW
377713 F3316TSRP 384025 F3316TSRPW 4000 13648 377782 F3317TSRP 384032 F3317TSRPW 4800 16380 23 488
377607 HF3315TSRP 384070 HF3315TSRPW
377690 HF3316TSRP 384087 HF3316TSRPW
377768 H3317TSRP 384094 H3317TSRPW 4800 16380 240 20.0 497
International Models
---- ---- 396480 M3315T2SRPWi
---- ---- 396493 M3316T2SRPWi
1500 5120 12.5
750 2560 6.25
3000 / 2250 10240
1500 / 1125 5120 6.2 / 5.4 4000 / 3000 13648 16.8 / 14.4 2000 / 1500 6826 8.3 / 7.2
3360 11468 1680 5734 7.64 4032 13761 18.33 2016 6881 9.16
120
208
240 / 208
220
8.3
19.2 476
12.5 / 10.8
15.27
Note: Fan switch not available on 277V models. 277V models are available without a fan switch on previous page.
Accessories - All Models
IVORY WHITE
UPC
686334 686334
377850 BOX3310 377850 BOX3310 ADDITIONAL BACK CAN 329958 3310EX33R 329965 3310EX33WR SURFACE MOUNTING FRAME 85
MODEL
SUFFIX D DISCONNECT SWITCH Factory Installed 108
UPC
MODEL
DESCRIPTION ACCESSORY TYPE LIST
Field Installed
467
476
509
99
Page 46
46
3200 Series Midsized Fan Forced Wall Heater - With Wall Box
Features
• Units have white powder coat nish.
• Approved for horizontal mounting - right or left discharge.
• Drywall depth embossments on back can.
• Powder coated 18 gauge steel front.
• Manual reset thermal limit.
• Finned tubular steel element.
• Weight 6 lbs.
• Propeller style fan blade: 2200 RPM / 70 CFM.
• Optional eld installed In-Built thermostat.
• Rough in dimensions: 9-1/4” Wide, 12-1/8” High, 3-5/8” Deep.
• Grill dimensions: 9-25/32” Wide, 13” High.
“TWO WIRE INSTALLATION”
Standard Models
Manufactured in U.S.A.
UPC
686334 BTU’S
383462 F3220T2RPW 208 2000 6826 9.6
383479 H3275T2RPW 240 750 2560 3.1
383486 HF3210T2RPW
383493 HF3215T2RPW 1500 / 1125 5120 / 3840 6.3 / 5.4
383509 HF3220T2RPW 2000 / 1500 6826 / 5120 8.3 / 7.2
383516 HF3222T2RPW 2250 / 1688 7680 / 5762 9.4 / 8.1
International Models - BUILT-IN DOUBLE POLE (POSITIVE OFF) THERMOSTAT 50° - 90° F RANGE
396387 M3210T2RPWi
396394 M3215T2RPWi 1260 4300 5.7
396400 M3220T2RPWi 1680 5734 7.6
396417 M3222T2RPWi 1890 6451 8.6
Standard Models - BUILT-IN SINGLE POLE (POSITIVE OFF) THERMOSTAT 50° - 90° F RANGE
383523 E3275TRPW
383547 E3215TRPW 1500 5120 12.5
383554 E3275RPW
383561 E3210RPW 1000 3413 8.33
383578 E3215RPW 1500 5120 12.5
383585 F3220RPW 208 2000 6826 9.6
383592 H3275RPW 240 750 2560 3.1
383608 HF3210RPW
383615 HF3215RPW 1500 / 1125 5120 / 3840 6.3 / 5.4
383622 HF3220RPW 2000 / 1500 6826 / 5120 8.3 / 7.2
383639 HF3222RPW 2250 / 1688 7680 / 5762 9.4 / 8.1
MODEL VOLTS WATTS
BUILT-IN DOUBLE POLE (POSITIVE OFF) THERMOSTAT 50° - 90° F RANGE
1000 / 750 3413 / 2560 4.2 / 3.6
240/208
840 2867 3.8
220
750 2560 6.25
120
NO BUILT-IN THERMOSTAT
750 2560 6.25
120
1000 / 750 3413 / 2560 4.2 / 3.6
240/208
MAX
AMPS LIST
254
254
238383530 E3210TRPW 1000 3413 8.33
219
FIELD INSTALLED COMPONENTS
UPC
686334
383646 32T1
383653 32T2
MODEL DESCRIPTION LIST
Single Pole thermostat with positive off
for 120V units 50o - 90o F
Double Pole thermostat with positive off
for 240/208V units 50o - 90o F
Accessories
48
54
SURFACE MOUNTED EXTENDERS & FRAMES
WHITE
UPC
686334
996976 303EX8RW 1” EXTENDER 39
996969 303EX16RW 2” EXTENDER 40
996952 303EX32RW 4” SURFACE MOUNT FRAME 46
MODEL
DESCRIPTION LIST
Page 47
4300 Series Low Prole Fan Forced Wall Heater - With Wall Box
Features
• Available in ivory or white.
• Powder coated 20 gauge steel front.
• Manual reset thermal limit.
• Finned tubular steel element.
• Weight 9 lbs.
Manufactured in U.S.A.
• Propeller style fan blade - 2200 RPM / 70 CFM
• Rough in dimensions: 14-1/2” Wide, 7-1/8” High, 3-1/2” Deep
• Grill dimensions: 16-3/4” Wide, 7-5/8” High
• Unit not approved for ceiling mount applications.
• Unit can be positioned to allow left, right or top discharge.
Standard Models
IVORY WHITE
UPC
686334
327695 F4320T2RP 327749 F4320T2RPW 208 2000 6826 9.6 327701 HF4375T2RP 327756 HF4375T2RPW 327718 HF4310T2RP 327763 HF4310T2RPW 1000 / 750 3413 / 2560 4.2 / 3.6 327725 HF4315T2RP 327770 HF4315T2RPW 1500 / 1125 5120 / 3840 6.3 / 5.4 327732 HF4320T2RP 327787 HF4320T2RPW 2000 / 1500 6826 / 5120 8.3 / 7.2
---- ---- 396448 M4375T2RPi
---- ---- 396455 M4310T2RPi 840 2869 3.8
---- ---- 396462 M4315T2RPi 1260 4300 5.7
---- ---- 396479 M4320T2RPi 1680 5733 7.6
327794 E4375TRP 327879 E4375TRPW 327800 E4310TRP 327886 E4310TRPW 1000 3413 8.33 327817 E4315TRP 327893 E4315TRPW 1500 5120 12.5 327824 F4320TRP 327909 F4320TRPW 208 2000 6826 9.6 327831 HF4375TRP 327916 HF4375TRPW 327848 HF4310TRP 327923 HF4310TRPW 1000 / 750 3413 / 2560 4.2 / 3.6 327855 HF4315TRP 327930 HF4315TRPW 1500 / 1125 5120 / 3840 6.3 / 5.4 327862 HF4320TRP 327947 HF4320TRPW 2000 / 1500 6826 / 5120 8.3 / 7.2
327954 E4375RP 328036 E4375RPW 327961 E4310RP 328043 E4310RPW 1000 3413 8.33 327978 E4315RP 328050 E4315RPW 1500 5120 12.5 327985 F4320RP 328067 F4320RPW 208 2000 6826 9.6 327992 HF4375RP 328074 HF4375RPW 328005 HF4310RP 328081 HF4310RPW 1000 / 750 3413 / 2560 4.2 / 3.6 328012 HF4315RP 328098 HF4315RPW 1500 / 1125 5120 / 3840 6.3 / 5.4 328029 HF4320RP 328104 HF4320RPW 2000 / 1500 6826 / 5120 8.3 / 7.2
MODEL
International Models - DOUBLE POLE IN-BUILT THERMOSTAT (RANGE 50° - 90°F)
Standard Models - SINGLE POLE INBUILT THERMOSTAT (RANGE 50° - 90°F)
UPC
686334
DOUBLE POLE IN-BUILT THERMOSTAT (RANGE 50° - 90°F)
NO IN-BUILT THERMOSTAT
MODEL
VOLTS WATTS MAX BTU’s AMPS LIST
750 / 562 2560 / 1920 3.1 / 2.7
240/208
630 2150 2.9
220
750 2560 6.25
120
750 / 562 2560 / 1920 3.1 / 2.7
240/208
750 2560 6.25
120
750 / 562 2560 / 1920 3.1 / 2.7
240/208
47
245
250
227
206
Accessories
UPC
686334
327657 4300EX8 328456 4300EX8W 1” SEMI RECESSING EXTENDER 2 43
327664 4300EX16 328463 4300EX16W 2” SEMI RECESSING EXTENDER 3 46
327671 4300EX32 328470 4300EX32W 4” SURFACE MOUNTING FRAME 4 49
327688 4300P 328487 4300PW WALL PLATE ADAPTOR (OD 21.5” x 12.25”) 1 31
FIELD INSTALLED
THERMOSTATS
IVORY
MODEL
UPC
686334
329774 43T SINGLE POLE THERMOSTAT 50O - 90O F 1 46
329781 43T2 DOUBLE POLE THERMOSTAT 50O - 90O F 1 52
WHITE
MODEL
ACCESSORY OPTIONS
WT.
LBS.
LIST
Page 48
4800 Series Register Style Fan Forced Wall Heater - With Wall Box
48
Features
• Units have white powder coat nish.
• Powder coated 20 gauge steel front.
• Manual reset thermal limit.
• Finned tubular steel element.
• Propeller style fan blade - 2200 RPM / 70 CFM.
• Weight 9 lbs.
• Rough in dimensions: 14-1/2” Wide x 7-1/8” High x 3-1/2” Deep.
• Grill dimensions: 16-3/4” Wide x 7-5/8” High.
• Unit not approved for ceiling mount applications.
Manufactured in U.S.A.
• Left discharge only.
Standard Models
UPC
686334 BTU’S
328159 F4820T2RPW 208 2000 6826 9.6
328166 HF4875T2RPW
328173 HF4810T2RPW 1000 / 750 3413 / 2560 4.2 / 3.6
328180 HF4815T2RPW 1500 / 1125 5120 / 3840 6.3 / 5.4
328197 HF4820T2RPW 2000 / 1500 6826 / 5120 8.3 / 7.2
MODEL VOLTS WATTS
DOUBLE POLE IN-BUILT THERMOSTAT (50º - 90º F TEMPERATURE RANGE)
750 / 562 2560 / 1920 3.1 / 2.7
240/208
MAX
AMPS LIST
264
SINGLE POLE IN-BUILT THERMOSTAT (50º - 90º F TEMPERATURE RANGE)
328203 E4875TRPW
328210 E4810TRPW 1000 3413 8.33
328227 E4815TRPW 1500 5120 12.5
328234 F4820TRPW 208 2000 6826 9.6
328241 E4875RPW
328258 E4810RPW 1000 3413 8.33
328265 E4815RPW 1500 5120 12.5
328272 F4820RPW 208 2000 6826 9.6
328289 HF4875RPW
328296 HF4810RPW 1000 / 750 3413 / 2560 4.2 / 3.6
328302 HF4815RPW 1500 / 1125 5120 / 3840 6.3 / 5.4
328319 HF4820RPW 2000 / 1500 6826 / 5120 8.3 / 7.2
120
NO IN-BUILT THERMOSTAT
120
240/208
750 2560 6.25
750 2560 6.25
750 / 562 2560 / 1920 3.1 / 2.7
Accessories
UPC#
686334
MODEL DESCRIPTION WT. LBS. LIST
247
226
328456 4300EX8W 1” SEMI RECESSING EXTENDER 2 43
328463 4300EX16W 2” SEMI RECESSING EXTENDER 3 46
328470 4300EX32W 4” SURFACE MOUNTING FRAME 4 49
328487 4300PW WALL PLATE ADAPTOR (OD 21.5” x 12.25”) 1 31
329774 43T SINGLE POLE THERMOSTAT 50O - 90O F 1 46
329798 48T2 DOUBLE POLE THERMOSTAT 50O - 90O F 1 49
Page 49
3900 Series Hydronic Electric Baseboard Heater
• Permanent mount self contained unit.
• Heating elements are immersed in a heat transferring liquid enclosed
by a Copper tube casing with Aluminum ns.
• Powder coated 12 gauge heavy duty extruded Aluminum housing with junction boxes located on each end of the unit.
• Automatic linear limit.
• Wire guard extends along the entire outlet area of the baseboard.
• Commercial Brown unit has in-built wireway.
• Special colors available, consult factory.
Manufactured in U.S.A.
STANDARD WHITE COMMERCIAL BROWN
UPC
686334 686334
111416 E3904-28 111645 E3904-28C 400 1360 120 3.3 111423 F3904-28 111652 F3904-28C 400 1360 208 1.92 111430 H3904-28 111669 H3904-28C 400/300 1360/1024 240/208 1.6/1.4 111447 G3904-28 111676 G3904-28C 400/300 1360 277/240 1.4 111454 E3906-36 111683 E3906-36C 600 2048 120 5 111461 F3906-36 111690 F3906-36C 600 2048 208 2.9 111478 H3906-36 111706 H3906-36C 600/450 2048/1536 240/208 2.5/2.2 111485 G3906-36 111713 G3906-36C 600/450 2048 277/240 2.2 111492 E3910-48 111720 E3910-48C 1000 3413 120 8.3 111508 F3910-48 111737 F3910-48C 1000 3413 208 4.8 111515 H3910-48 111744 H3910-48C 1000/750 3413/2560 240/208 4.2/3.6 111522 G3910-48 111751 G3910-48C 1000/750 3413 277/240 3.6 111539 E3912-60 111768 E3912-60C 1250 4265 120 10.4 111546 F3912-60 111775 F3912-60C 1250 4265 208 6 111553 H3912-60 111782 H3912-60C 1250/938 4265/3201 240/208 5.2/4.5 111560 G3912-60 111799 G3912-60C 1250/938 4265 277/240 3.6 111577 E3915-72 111805 E3915-72C 1500 5100 120 12.5 111584 F3915-72 111812 F3915-72C 1500 5100 208 7.2 111591 H3915-72 111829 H3915-72C 1500/1125 5100/3825 240/208 6.3/5.4 111607 G3915-72 111836 G3915-72C 1500/1125 5100 277/240 5.4 111614 F3920-96 111842 F3920-96C 2000 6826 208 9.6
111638 G3920-96 111867 G3920-96C 2000/1500 6826 277/240 7.2
MODEL
UPC
MODEL
• Suitable for high altitude applications.
• 1 Year element warranty.
Standard Models
WATTS BTU’S. VOLTS AMPS
HEATER
LENGTH
(IN.)
28 16 350 372
36 22 401 426
48 27 467 495
60 33 531 578
72 41 597 639
96 58 709 763111621 H3920-96 111850 H3920-96C 2000/1500 6826/5100 240/208 8.3/7.2
WT.
(LBS)
WHITE
LIST
49
BROWN
LIST
Product Specications & Dimensions
The entire heater casing shall be
constructed of 6063 extruded Aluminum.
3.00”
minimum thickness of .100” (12 gauge) Aluminum shall be acceptable. Outlet grill shall cover entire length of air discharge opening and be constructed of steel. All casing and grill construction shall be painted with high quality durable powder coated paint. The heating element shall be high quality
8.50”
Nichrome wire encased in Magnesium Oxide and sealed in copper tube. The heating element shall be sealed in .312” diameter Copper tube and be
1.43
immersed in heat transfer liquid. Aluminum ns
shall be mechanically bonded to the entire heated length of the element for even heat transfer. Linear automatic thermal limit shall
4.10
2.42 WIRE NUT
extend the entire heater length of element and protect heater in case of an over-temperature
1.60
2.1
condition. Optional controls shall be mounted in junction box enclosures at either end of heater. Optional integral thermostat shall be located in junction box with adjustment knob or for tamper-proof operation. Optional disconnect switch shall be mounted in junction box. Optional 120 Volt or air conditioning receptacle shall be mounted in junction box.
Optional installation accessories shall include inside and outside corner sections for complete wall perimeter t. Prole of
corners and grill shall have appearance of heat sections for continuous architectural design. Corner accessories and heater sections shall be secured by alignment pins for easy alignment of multiple heater applications.
TEMPERATURE LIMITING DEVICE
Page 50
50
3700 Series Architectural Style Electric Baseboard Heater
• Available in white or brown with stainless steel heating element and
aluminum ns.
• Powder coated 12 gauge heavy duty extruded Aluminum housing construction with junction boxes located on each end of the unit.
• An automatic thermal linear limit is used along the entire heated length of the unit.
• Wire guard extends along the entire outlet area of the baseboard.
• Special colors available, consult factory.
Standard Models
STANDARD WHITECOMMERCIAL BROWN
UPC
686334
116008 E3703-024 116435 E3703-024B 375 1275 120 3.1
116015 F3703-024 116442 F3703-024B 375 1275 208 1.8
116022 H3703-024 116459 H3703-024B 375 / 281 1275 / 955 240 / 208 1.6/1.4
116039 G3703-024 116466 G3703-024B 375 / 281 1275 / 955 277 / 240 1.6/1.2
116046 E3705-028 116473 E3705-028B 500 1706 120 4.2
116053 F3705-028 116480 F3705-028B 500 1706 208 2.4
116060 H3705-028 116497 H3705-028B 500 / 375 1706 / 1275 240 / 208 2.1/1.8
116077 G3705-028 116503 G3705-028B 500 / 375 1706 / 1275 277 / 240 1.8/1.6
116084 E3706-036 116510 E3706-036B 600 2040 120 5
116091 F3706-036 116527 F3706-036B 600 2040 208 2.9
116107 H3706-036 116534 H3706-036B 600 / 450 2040 / 1530 240 / 208 2.5/2.2
116114 G3706-036 116541 G3706-036B 600 / 450 2040 / 1530 277 / 240 2.2/1.9
116121 E3707-040 116558 E3707-040B 750 2550 120 6.3
116138 F3707-040 116565 F3707-040B 750 2550 208 3.6
116145 H3707-040 116572 H3707-040B 750 / 563 2550 / 1914 240 / 208 3.1/2.7
116152 G3707-040 116589 G3707-040B 750 / 563 2550 / 1914 277 / 240 2.7.2.6
116169 E3710-048 116596 E3710-048B 1000 3413 120 8.3
116176 F3710-048 116602 F3710-048B 1000 3413 208 4.8
116183 H3710-048 116619 H3710-048B 1000 / 750 3413 / 2550 240 / 208 4.2/3.6
116190 G3710-048 116626 G3710-048B 1000 / 750 3413 / 2550 277 / 240 3.6/3.1
116206 G3707-048 116633 G3707-048B 750 2550 277 3.4
116213 E3712-060 116640 E3712-060B 1250 4250 120 10.4
116220 F3712-060 116657 F3712-060B 1250 4250 208 6
116237 H3712-060 116664 H3712-060B 1250 / 938 4250 / 3189 240 / 208 5.2/4.5
116244 G3712-060 116671 G3712-060B 1250 / 938 4250 / 3189 277 / 240 4.5/3.9
116251 G3709-060 116688 G3709-060B 938 3189 277 3.4
116268 E3715-072 116695 E3715-072B 1500 5100 120 12.5
116275 F3715-072 116701 F3715-072B 1500 5100 208 7.2
116282 H3715-072 116718 H3715-072B 1500 / 1125 5100 / 3825 240 / 208 6.3/4.7
116299 G3715-072 116725 G3715-072B 1500 / 1125 5100 / 3825 277 / 240 5.4/4.7
116305 G3711-072 116732 G3711-072B 1125 3825 277 4.1
116312 F3717-084 116749 F3717-084B 1750 5950 208 8.4
116329 H3717-084 116756 H3717-084B 1750 / 1313 5950 / 4464 240 / 208 7.3/6.3
116336 G3717-084 116763 G3717-084B 1750 / 1313 5950 / 4464 277 / 240 6.3/5.5
116343 G3713-084 116770 G3713-084B 1313 4464 277 4.7
116350 F3720-096 116787 F3720-096B 2000 6826 208 9.6
116367 H3720-096 116794 H3720-096B 2000 / 1500 6826 / 5100 240 / 208 8.3/7.2
116374 G3720-096 116800 G3720-096B 2000 / 1500 6826 / 5100 277 / 240 7.2/6.3
116381 G3715-096 116817 G3715-096B 1500 5100 277 5.4
116398 F3725-120 116824 F3725-120B 2500 8532 208 12
116404 H3725-120 116831 H3725-120B 2500 / 1875 8532 / 6375 240 / 208 10.4/9.0
116411 G3725-120 116848 G3725-120B 2500 / 1875 8532 / 6375 277 / 240 9.0/7.8
116428 G3718-120 116855 G3718-120B 1875 6375 277 6.8
MODEL
Note: Refer to 3900 Series for product dimension specications.
Note: Please see page 60 for custom color availability - add 10% to net heater cost.
UPC
686334
MODEL
WATTS BTU’s VOLTS AMPS
HEATER LENGTH
(IN.)
24 14
28 16
36 22
40 27
48 31
60 33
72 41
84 49
96 58
120 67
Manufactured in U.S.A.
WT.
WHITE
(LBS.)
BROWN
LIST
LIST
299 311
331 344
382 396
389 402
402 415
526 539
589 603
661 674
698 719
785 797
Product Specications
The entire heater casing shall be constructed of 6063 extruded Aluminum. Minimum thickness of .100” (12 gauge) Aluminum shall be acceptable. Outlet grill shall cover entire length of air discharge opening and be constructed of steel. All casing and grill construction shall be painted with high quality durable powder coated paint. The heating element shall be high quality nichrome wire encased in Magnesium Oxide and sealed in a stainless steel tube. Linear automatic thermal limit shall extend the entire heater length of element and protect heater in case of an over-temperature condition. Optional controls shall be mounted in junction box enclosures at either end of heater. Optional integral thermostat shall be located in junction box with adjustment knob or for tamper-proof operation. Optional disconnect switch shall be mounted in junction box. Optional 120 Volt or air conditioning receptacle shall be mounted in junction box. Optional installation accessories shall include inside and outside corner sections for complete wall
perimeter t. Prole of corners
and grill shall have appearance of heat sections for continuous architectural design. Corner accessories and heater sections shall be secured by alignment pins for easy alignment of multiple heater applications.
Page 51
Hydronic & Architectural Electric Baseboard Heater Accessories
Field Installed Accessories
Standard White Commercial Brown
DESCRIPTION
Single Pole, In-Built T-Stat, 22A @ 120-240V; 18A @ 277V; 50°-90° F 111874 3900T1 111959 3900T1C 61
Double Pole, In-Built T-Stat, 22A @ 120-240V; 18A @ 277V; 50°-90° F 111881 3900T2 111966 3900T2C 79
Air Conditioning Receptacle Section, 20 Amp @ 125-277V 111898 3900AC 111997 3900ACC 72
120V. Receptacle Section, 15 Amp 111904 3900REC 112000 3900RECC 67
Disconnect Switch, 20 Amp @ 125-277VAC; DPST 111942 3900DS 112048 3900DSC 99
STANDARD WHITE COMMERCIAL BROWN DESCRIPTION
UPC#
686334
MODEL
UPC#
686334
MODEL
Baseboard Sections
UPC#
686334
MODEL SECTION SIZE
UPC#
686334
MODEL
51
LIST
LIST
OUTSIDE
CORNER
INSIDE
CORNER
Outside and inside corner
sections are 6” on longest side
Dimension
3.00”
112154 39BS28 112215 39BS28C
112161 39BS36 112222 39BS36C 36” 256
112178 39BS48 112239 39BS48C 48” 317
112185 39BS60 112246 39BS60C 60” 380
112192 39BS72 112253 39BS72C 72” 438
112208 39BS96 112260 39BS96C 96” 563
115094 39BS120 115100 39BS120C 120” 751
111911 3900-ICS 112017 3900-ICSC Inside Corner
111928 3900-OCS 112024 3900-OCSC Outside Corner 125
111935 3900-CS 112031 3900-CSC Control Section 4” Blank 157
Blank Section
28” 215
-
Wireway Covers (White Units Only)
TEMPERATURE LIMITING DEVICE
UPC#
686334
112284 3900WW28 28” 2 47
MODEL LENGTH
SHIP WT.
(LBS)
123
LIST
4.10
1.43
1.60
2.42
8.50”
WIRE NUT
112291 3900WW36 36” 2.5 52
112307 3900WW48 48” 3.5 62
112314 3900WW60 60” 4.5 68
112321 3900WW72 72” 5.5 73
112338 3900WW96 96” 7.5 96
115117 3900WW120 120” 7.5 129
2.1
Page 52
52
2900HA Series Electric Baseboard - High Altitude Convection Heater
Features
• Available in white or ivory with Aluminum heating element and Aluminum ns.
• Painted 22 gauge steel front with 20 gauge junction boxes located on each end of the heater - junction boxes contain quick connect cable clamps and 6” ground lead wires.
• Over-temperature thermal limit extends entire length of heated area.
• A full length wireway provided along the back of the heater.
• Optional enclosed conduit wireway available.
• Heater can be mounted to the wall by using the key hole knockouts every 4” at the back of the heater.
Manufactured in U.S.A.
UPC#
686334 101226 E2903-024HAW 375 1275 120 3.1 101233 F2903-024HAW 375 1275 208 1.8 101240 H2903-024HAW 375 / 281 1275 / 955 240 / 208 1.6/1.4 101257 G2903-024HAW 375 / 281 1275 / 955 277 / 240 1.6/1.2 101264 E2905-028HAW 500 1706 120 4.2 101271 F2905-028HAW 500 1706 208 2.4 101288 H2905-028HAW 500 / 375 1706 / 1275 240 / 208 2.1/1.8 101295 G2905-028HAW 500 / 375 1706 / 1275 277 / 240 1.8/1.6 101301 E2906-036HAW 600 2040 120 5 101318 F2906-036HAW 600 2040 208 2.9 101325 H2906-036HAW 600 / 450 2040 / 1530 240 / 208 2.5/2.2 101332 G2906-036HAW 600 / 450 2040 / 1530 277 / 240 2.2/1.9 101349 E2907-040HAW 750 2550 120 6.3 101356 F2907-040HAW 750 2550 208 3.6 101363 H2907-040HAW 750 / 563 2550 / 1914 240 / 208 3.1/2.7 101370 G2907-040HAW 750 / 563 2550 / 1914 277 / 240 2.7.2.6 101387 E2910-048HAW 1000 3413 120 8.3 101394 F2910-048HAW 1000 3413 208 4.8 101400 H2910-048HAW 1000 / 750 3413 / 2550 240 / 208 4.2/3.6 101417 G2910-048HAW 1000 / 750 3413 / 2550 277 / 240 3.6/3.1 101424 G2907-048HAW 750 2550 277 3.4 101431 E2912-060HAW 1250 4250 120 10.4 101448 F2912-060HAW 1250 4250 208 6 101455 H2912-060HAW 1250 / 938 4250 / 3189 240 / 208 5.2/4.5 101462 G2912-060HAW 1250 / 938 4250 / 3189 277 / 240 4.5/3.9 101479 G2909-060HAW 938 3189 277 3.4 101486 E2915-072HAW 1500 5100 120 12.5 101493 F2915-072HAW 1500 5100 208 7.2 101509 H2915-072HAW 1500 / 1125 5100 / 3825 240 / 208 6.3/4.7 101516 G2915-072HAW 1500 / 1125 5100 / 3825 277 / 240 5.4/4.7 101523 G2911-072HAW 1125 3825 277 4.1 101578 F2920-096HAW 2000 6826 208 9.6 101585 H2920-096HAW 2000 / 1500 6826 / 5100 240 / 208 8.3/7.2 101592 G2920-096HAW 2000 / 1500 6826 / 5100 277 / 240 7.2/6.3 101608 G2915-096HAW 1500 5100 277 5.4 101653 F2925-120HAW 2500 8532 208 12 101660 H2925-120HAW 2500 / 1875 8532 / 6375 240 / 208 10.4/9.0 101677 G2925-120HAW 2500 / 1875 8532 / 6375 277 / 240 9.0/7.8 101684 G2918-120HAW 1875 6375 277 6.8
WHITE MODEL
• Optional In-Built thermostats eld installed in the junction box.
• HEIGHT: 6” DEPTH: 2-1/2”
• Ivory available with extended lead times-consult factory.
Standard Models
WATTS BTU’s VOLTS AMPS
HEATER
LENGTH (IN)
24 5 62
28 6 64
36 7 71
40 8 74
48 10 89
60 12 111
72 14 125
96 18 153
120 22 169
WT.
(LBS.)
LIST
2900A Series - International Models
UPC# 686334 WHITE MODEL WATTS BTU’s VOLTS HEATER LENGTH (IN)
115766 M2903-24AWi 115773 H2903-24AWi 240 115780 M2905-28AWi 115977 H2905-28AWi 240 115803 M2906-36AWi 115810 H2906-36AWi 240 115827 M2907-40AWi 115834 H2907-40AWi 240 115841 M2910-48AWi 115858 H2910-48AWi 240 115865 M2912-60AWi 115872 H2912-60AWi 240 115889 M2915-72AWi 115896 H2915-72AWi 240 115902 M2917-84AWi 118002 H2917-84AWi 240 118033 M2925-120AWi 118040 H2920-120AWi 240
375 1275
500 1706
600 2040
750 2550
1000 3413
1250 4250
1500 5100
1750 5950
2500 8532
Wireway Length Same As Baseboard Length
220
220
220
220
220
220
220
220
220
24” 10 81
28” 11 84
36” 11.5 93
40” 13 97
48” 14 116
60” 16 145
72” 19 163
80” 22 199
120” 31 220
WEIGHT (LBS) LIST
Page 53
2900S Series Electric Baseboard - Stainless Steel Element Convection Heater
Features
• Available in white or ivory with stainless steel heating element and Aluminum
ns.
• Painted 22 gauge steel front with 20 gauge junction boxes located on each end of the heater - junction boxes contain quick connect cable clamps and 6”ground lead wires.
• Over-temperature thermal limit extends entire length of heated area.
• A full length wireway provided along the back of the heater - enclosed conduit
Manufactured in U.S.A.
available.
• Heater can be mounted to the wall by using the key hole knockouts every 4” at the back of the heater.
Optional In-Built thermostats eld installed in the junction box.
• HEIGHT: 6” DEPTH: 2-1/2”
Standard Models
53
UPC IVORY UPC WHITE
686334 MODEL 686334 MODEL
104302 E2903-024S 104999 E2903-024SW 375 1275 120 3.1 104319 F2903-024S 105002 F2903-024SW 375 1275 208 1.8 104326 H2903-024S 105019 H2903-024SW 375 / 281 1275 / 955 240 / 208 1.6/1.4 104333 G2903-024S 105026 G2903-024SW 375 / 281 1275 / 955 277 / 240 1.6/1.2 104340 E2905-028S 105033 E2905-028SW 500 1706 120 4.2 104357 F2905-028S 105040 F2905-028SW 500 1706 208 2.4 104364 H2905-028S 105057 H2905-028SW 500 / 375 1706 / 1275 240 / 208 2.1/1.8 104371 G2905-028S 105064 G2905-028SW 500 / 375 1706 / 1275 277 / 240 1.8/1.6 104388 E2906-036S 105071 E2906-036SW 600 2040 120 5 104395 F2906-036S 105088 F2906-036SW 600 2040 208 2.9 104401 H2906-036S 105095 H2906-036SW 600 / 450 2040 / 1530 240 / 208 2.5/2.2 104418 G2906-036S 105101 G2906-036SW 600 / 450 2040 / 1530 277 / 240 2.2/1.9 104425 E2907-040S 105118 E2907-040SW 750 2550 120 6.3 104432 F2907-040S 105125 F2907-040SW 750 2550 208 3.6 104449 H2907-040S 105132 H2907-040SW 750 / 563 2550 / 1914 240 / 208 3.1/2.7 104456 G2907-040S 105149 G2907-040SW 750 / 563 2550 / 1914 277 / 240 2.7.2.6 104463 E2910-048S 105156 E2910-048SW 1000 3413 120 8.3 104470 F2910-048S 105163 F2910-048SW 1000 3413 208 4.8 104487 H2910-048S 105170 H2910-048SW 1000 / 750 3413 / 2550 240 / 208 4.2/3.6 104494 G2910-048S 105187 G2910-048SW 1000 / 750 3413 / 2550 277 / 240 3.6/3.1 104500 G2907-048S 105194 G2907-048SW 750 2550 277 3.4 104517 E2912-060S 105200 E2912-060SW 1250 4250 120 10.4 103008 F2912-060S 105217 F2912-060SW 1250 4250 208 6 103015 H2912-060S 105224 H2912-060SW 1250 / 938 4250 / 3189 240 / 208 5.2/4.5 103022 G2912-060S 105231 G2912-060SW 1250 / 938 4250 / 3189 277 / 240 4.5/3.9 103039 G2909-060S 105248 G2909-060SW 938 3189 277 3.4 103046 E2915-072S 105255 E2915-072SW 1500 5100 120 12.5 103053 F2915-072S 105262 F2915-072SW 1500 5100 208 7.2 103060 H2915-072S 105279 H2915-072SW 1500 / 1125 5100 / 3825 240 / 208 6.3/4.7 103077 G2915-072S 105286 G2915-072SW 1500 / 1125 5100 / 3825 277 / 240 5.4/4.7 103084 G2911-072S 105293 G2911-072SW 1125 3825 277 4.1 103091 F2917-084S 105309 F2917-084SW 1750 5950 208 8.4 103107 H2917-084S 105316 H2917-084SW 1750 / 1313 5950 / 4464 240 / 208 7.3/6.3
103114 G2917-084S 105323 G2917-084SW 1750 / 1313 5950 / 4464 277 / 240 6.3/5.5 103121 G2913-084S 105330 G2913-084SW 1313 4464 277 4.7 103138 F2920-096S 105347 F2920-096SW 2000 6826 208 9.6 103145 H2920-096S 105354 H2920-096SW 2000 / 1500 6826 / 5100 240 / 208 8.3/7.2 103152 G2920-096S 105361 G2920-096SW 2000 / 1500 6826 / 5100 277 / 240 7.2/6.3 103169 G2915-096S 105378 G2915-096SW 1500 5100 277 5.4 103213 F2925-120S 105422 F2925-120SW 2500 8532 208 12 103220 H2925-120S 105439 H2925-120SW 2500 / 1875 8532 / 6375 240 / 208 10.4/9.0 103237 G2925-120S 105446 G2925-120SW 2500 / 1875 8532 / 6375 277 / 240 9.0/7.8 103244 G2918-120S 105453 G2918-120SW 1875 6375 277 6.8
WATTS BTU’s VOLTS AMPS
HEATER LENGTH
(IN)
24 5 60
28 6 62
36 7 70
40 8 72
48 10 87
60 12 107
72 14 123
84 16 135
96 18 150
120 22 164
WT.
(LBS.)
LIST
Page 54
2900C Series Electric Baseboard - Heavy Duty Commercial Convection Heater
Features
54
Manufactured in U.S.A.
UPC#
686334
103831 E2903-024C 375 1275 120 3.1 103848 F2903-024C 375 1275 208 1.8 103855 H2903-024C 375 / 281 1275 / 955 240 / 208 1.6 / 1.4 103862 G2903-024C 375 / 281 1275 / 955 277 / 240 1.6 / 1.2 103879 E2905-028C 500 1706 120 4.2 103886 F2905-028C 500 1706 208 2.4 103893 H2905-028C 500 / 375 1706 / 1275 240 / 208 2.1 / 1.8 103909 G2905-028C 500 / 375 1706 / 1275 277 / 240 1.8 / 1.6 103916 E2906-036C 600 2040 120 5.0 103923 F2906-036C 600 2040 208 2.9 103930 H2906-036C 600 / 450 2040 / 1530 240 / 208 2.5 / 2.2 103947 G2906-036C 600 / 450 2040 / 1530 277 / 240 2.2 / 1.9 103954 E2907-040C 750 2550 120 6.3 103961 F2907-040C 750 2550 208 3.6 103978 H2907-040C 750 / 563 2550 / 1914 240 / 208 3.1 / 2.7 103985 G2907-040C 750 / 563 2550 / 1914 277 / 240 2.7 / 2.6 103992 E2910-048C 1000 3413 120 8.3 104005 F2910-048C 1000 3413 208 4.8 104012 H2910-048C 1000 / 750 3413 / 2550 240 / 208 4.2 / 3.6 104029 G2910-048C 1000 / 750 3413 / 2550 277 / 240 3.6 / 3.1 104036 G2907-048C 750 2550 277 3.4 104043 E2912-060C 1250 4250 120 10.4 104050 F2912-060C 1250 4250 208 6.0 104067 H2912-060C 1250 / 938 4250 / 3189 240 / 208 5.2 / 4.5 104074 G2912-060C 1250 / 938 4250 / 3189 277 / 240 4.5 / 3.9 104081 G2909-060C 938 3189 277 3.4 104098 E2915-072C 1500 5100 120 12.5 104104 F2915-072C 1500 5100 208 7.2 104111 H2915-072C 1500 / 1125 5100 / 3825 240 / 208 6.3 / 4.7 104128 G2915-072C 1500 / 1125 5100 / 3825 277 / 240 5.4 / 4.7 104135 G2911-072C 1125 3825 277 4.1 104142 F2917-084C 1750 5950 208 8.4 104159 H2917-084C 1750 / 1313 5950 / 4464 240 / 208 7.3 / 6.3 104166 G2917-084C 1750 / 1313 5950 / 4464 277 / 240 6.3 / 5.5 104173 G2913-084C 1313 4464 277 4.7 104180 F2920-096C 2000 6826 208 9.6 104197 H2920-096C 2000 / 1500 6826 / 5100 240 / 208 8.3 / 7.2 104203 G2920-096C 2000 / 1500 6826 / 5100 277 / 240 7.2 / 6.3 104210 G2915-096C 1500 5100 277 5.4 104265 F2925-120C 2500 8532 208 12.0 104272 H2925-120C 2500 / 1875 8532 / 6375 240 / 208 10.4 / 9.0 104289 G2925-120C 2500 / 1875 8532 / 6375 277 / 240 9.0 / 7.8 104296 G2918-120C 1875 6375 277 6.8
BRONZE
MODEL
WATTS BTU’s VOLTS AMPS
Bankers bronze with stainless steel heating element and Aluminum ns.
• Powder coated 22 gauge steel front with 20 gauge junction boxes located on each end of the heater - junction boxes contain quick connect cable clamps and 6” ground lead wires.
• Standard inlet and outlet wire guards.
• Over-temperature thermal limit extends entire heated length of unit.
• A full length wireway provided along the back of the heater.
• Heater can be mounted to the wall by using the key hole knockouts every 4” at the back of the heater.
Optional In-Built thermostats eld installed in the junction box.
• HEIGHT: 6” DEPTH: 2-1/2”
Standard Models
HEATER
LENGTH (IN)
24 5 137
28 6 171
36 7 195
40 8 204
48 10 236
60 12 282
72 14 324
84 16 360
96 18 398
120 22 418
WEIGHT
(LBS)
LIST
International Models
UPC#
686334
118057 M2903-024CI 118064 H2903-024CI 240 240 118071 M2905-028CI 118088 H2905-028CI 240 2.1 118095 M2906-036CI 118101 H2906-036C 240 2.5 118118 M2907-040CI 118125 H2907-040C 240 3.1 118132 M2910-048CI 118149 H2910-048CI 240 4.2 118156 M2912-060CI 118163 H2912-060C 240 5.2 118170 M2915-072CI 118187 H2915-072CI 240 6.3 118194 M2917-084CI 118200 H2917-084CI 240 7.3 118217 M2920-096CI 118224 H2920-096CI 240 8.3 118231 M2925-120CI 118248 H2925-120CI 240 10.4
BRONZE
MODEL
WATTS BTU’s VOLTS AMPS
375 1275
500 1706
600 2040
750 2550
1000 3413
1250 4250
1500 5100
1750 5950
2000 6826
2500 8532
220 1.7
220 2.3
220 2.7
220 3.4
220 4.6
220 5.7
220 6.8
220 8.0
220 9.1
220 11.4
HEATER
LENGTH (IN)
24 5 137
28 6 171
36 7 195
40 8 204
48 10 236
60 12 282
72 14 324
84 16 360
96 18 398
120 22 418
WEIGHT
(LBS)
LIST
Page 55
Electric Baseboard - Accessories
In-Built Thermostat Kits- With Two Cover Plates
IVORY & WHITE
UPC 686334
105460 TBS SPST-In-Built 22A @ 120-240V 18A @ 277V
502702 TBS-TP SPST-In-Built 22A @ 120-240V 18A @ 277V Tamperproof
105477 TBD DPST-In-Built 22A @ 120-240V 18A @ 277V
502719 TBD-TP DPST-In-Built 22A @ 120-240V 18A @ 277V Tamperproof
MODEL
NUMBER
DESCRIPTION
WEIGHT
(LBS)
1/2 lbs. 40
1/2 lbs. 52
Field Installed Accessories
IVORY WHITE BANKERS BRONE
DESCRIPTION
UPC 686334 MODEL UPC 686334 MODEL UPC 686334 MODEL
Disconnect Switch, 20
Amp, 120-277V
Corner Sections 105491 CS 105507 CSW 105514 CSB 34
106108 DS 106115 DSW 106122 DSB
WEIGHT
(LBS)
1 lb.
55
LIST
LIST
78
1” Joiner Kits 105521 JK 105538 JKW 105545 JKB 1/4 lb. 23
6” Blank Relay Section (Relay Not Included)**
Receptacle Section
(Baseboard Mounted)
15 Amp 120 VAC
Receptacle Section
(Mounted in 6” Blank)
15 Amp 120 VAC
Transfer Switch
(Mounted in 6” Blank)
16 Amp 120 VAC
Transfer Switch
(Mounted in 6” Blank)
16 Amp 240 VAC
105552 LVRS 105569 LVRSW 105576 LVRSB 1 1/2 lbs. 95
105583 BDR115 105590 BDR115W 105606 BDR115B 1/4 lb. 23
105613 DR115 105620 DR115W 105637 DR115B
105644 SR120 105651 SR120W 105668 SR120B 139
105675 SR220 105682 SR220W 105699 SR220B 169
2 lbs.
**Not for use with 24A06G-1 relay.
Optional Wireway Covers
UPC
MODEL
686334
105705 WWA01 24 20 1 33
105712 WWA02 28 24 1.5 36
105729 WWA03 36 32 2 39
105736 WWA04 40 36 2.5 45
105743 WWA05 48 44 3 47
105750 WWA06 60 56 4 50
105767 WWA07 72 68 5 57
105774 WWA08 84 80 6 65
105781 WWA09 96 92 7 75
105798 WWA00 120 116 8 91
BASEBOARD
LENGTH
(in.)
COVER
LENGTH
(in.)
WEIGHT
(LBS)
LIST
LENGTH
24” 105804 BBS024A 105903 BBS024AW 106009 BBS024C 5 52 107
28” 105811 BBS028A 105910 BBS028AW 106016 BBS028C 5 1/2 57 117
36” 105828 BBS036A 105927 BBS036AW 106023 BBS036C 6 69 135
40” 105835 BBS040A 105934 BBS040AW 106030 BBS040C 7 74 142
48” 105842 BBS048A 105941 BBS048AW 106047 BBS048C 8 83 146
60” 105859 BBS060A 105958 BBS060AW 106054 BBS060C 10 100 202
72” 105866 BBS072A 105965 BBS072AW 106061 BBS072C 12 120 222
84” 105873 BBS084A 105972 BBS084AW 106078 BBS084C 15 126 253
96” 105880 BBS096A 105989 BBS096AW 106085 BBS096C 17 147 283
120” 105897 BBS120A 105996 BBS120AW 106092 BBS120C 20 180 357
IVORY WHITE BANKERS BRONZE
UPC MODEL UPC MODEL UPC MODEL
Blank Sections
WEIGHT
(LBS)
IVORY
WHITE
LIST
110
BRONZE
LIST
Page 56
9100 Series - Radius Front Draft Barrier Heater
56
ETL listed up to 250 Watts / foot for industrial, commercial, or residential
applications.
Manufactured in U.S.A.
HOW TO DESIGNATE A MODEL:
Element Volts E = 120 F = 208 G = 277 H = 240
• Standard colors, white or ivory.
• “UNI-LOCK” construction allows snap-t, 2 piece
installation.
• Units can be controlled by optional In-Built thermostat or can be constructed with relays and / or transformers for low voltage or line voltage wall thermostats
• Thermal protection by full length manual reset linear limits
• Optional duplex receptacle section
• Wiring junction boxes on each end of the unit
• Custom colors and nishes available (consult factory)
• Limited by max Amp draw of 25 Amps (with no controls).
• Additional charges may be incurred if changes are made after production has begun - consult factory.
E 91 96 250 ITS PD
Model Series 91
Heater Length (inches) 28, 36, 48, 60, 72, 84, 96, 108, or 120
Watts Per Foot 100, 125, 150, 165, 187, 200, or 250
Features
Control Options Refer to Pg. 60
Factory Installed Accessories PD = Pedestal DR = Receptacle WM = Screen
Product Description
TECHNICAL INFORMATION
Air Intake Bottom
Air Discharge To p
Min Mounting Height 3”
Max Watts / Foot 250
Max Allowable Amps 25 Amps (20 Amps with disconnect)
Voltage / Phase 120V/208V/240V/277V Single Phase
Standard Models
MODEL
Heater
UNIT
LENGTH
9128 28” 298
9136 36” 343 45
9148 48” 394 48
9160 60” 459 54
9172 72” 524 58
9184 84” 604 68
9196 96” 660 75
91108 108” 728 87
91120 120” 797 98
LIST
BACK ADDER
FINISHED
39
MODEL
91BS012 12” 83 34
91BS024 24” 11 2 39
91BS036 36” 144 45
91BS048 48” 174 48
91BS060 60” 204 54
91BS072 72” 237 58
91BS084 84” 289 68
Blank Section
91BS096 96” 298 75
91BS108 108” 329 87
91BS120 120” 359 98
LENGTH
UNIT
LIST
BACK ADDER
Height 4 1/2”
Depth 3 1/8”
Length 28” to 120” in 1’ increments
Cabinet Material Material
Optional Controls That Can
FINISHED
Gauge
Be Built Into Unit
SUFFIX DESCRIPTION LIST
DR
PD
WM 1/4” wire mesh under grill
MODEL DESCRIPTION LIST
9100IC Inside Corner Section 90° or 135°
9100OC Outside Corner Section 90° or 135°
9100EC Right or Left End Cap 61
TECHNICAL INFORMATION
Aluminum
14
Thermostat and Disconnect Switch
(Control Section Required for Relays)
Factory Installed Accessories
Duplex Receptacle in 4” Extended
Enclosure (not available with 120” heater)
28” through 60” - 2 Required 124 72” through 96” - 3 Required 186
108” through 120” - 4 Required 248
Field Installed Accessories
187
$6.00
Per foot
180
Note: All models are suitable for International use Note: Extended enclosure per foot is 33 dollars.
Page 57
9100 Series - Radius Front Draft Barrier Heater
Product Specications
CABINET
9100 Series shall be constructed of 14 gauge extruded 6063 Aluminum heat treated to T5 hardness. The
uni-lock construction shall allow easy installation and access to back plate for wiring. The snap-t front
cover makes installation and service very simple. Custom factory enclosures to 1/16 inch increments are
built for exact wall to wall t up to 10 foot enclosure lengths. The 14 gauge back plate will have electrical
knockouts for incoming power on each end adjacent to junction box. Pedestal mounted units will have incoming power connection through the pedestal on bottom of unit and will have smooth back for optional
nished back. The die punched front cover will have no screw heads or fasteners.
ELEMENTS
High mass sheathed element construction with Nickel-Chromium resistance wire embedded in compacted
efcient die-electric to ensure proper heat transfer. Aluminum ns mechanically bonded to stainless steel
tube allows for increased surface area and even heat transfer.
LIMIT CONTROLS
Manual reset hydraulic thermal overload covers full length of heating element and shuts down heater when safe operating temperatures are exceeded.
57
WIRING
Wiring shall be in either end of the enclosure. Wiring can be in the junction box or optional control section if additional controls are needed. Pedestal mounted units shall have 1-1/4” hole through the pedestal and in the bottom of the enclosure for incoming power wiring. All heaters have a factory supplied built in raceway for wiring from either end of the heater or for wiring of continuous heater connections.
CONTROLS
Optional controls include single or double pole thermostat and disconnect switch that are factory wired in enclosed junction box on each end of heater enclosure. Relay, transformer relay and duplex receptacle options shall be mounted in extended length control section. Control section will add to heater enclosure length. The control section for the duplex receptacle will add 4” to enclosure length. The control section for other optional components or combinations of components will have two options (6” or 12”) depending on controls required.
APPLICATION
The 9100 series is ETL listed for commercial, industrial or residential applications on all units up to 250 Watts per foot.
Product Dimensions
OUTSIDE CORNER SECTION
BACK VIEW
INSIDE CORNER SECTION
6.0”
1-1/8"
1-9/16"
1-1/2"
4-1/2"
3" MINIMUM
3-1/8"
1-9/16"
FINISHED FLOOR
WALL MOUNT
3-1/8"
15/16"
PEDESTAL MOUNT
Ø .395 (TYP)
1-9/16"
2-1/16"
3"
2-7/16"
TYP
PEDESTAL BASE
3-1/16”
6.0”
Page 58
HOW TO DESIGNATE A MODEL:
9300 Series - Radius Front Draft Barrier Heater
58
ETL listed up to 750 Watts
/ foot for industrial or
commercial applications.
Manufactured in U.S.A.
Element Volts E = 120 F = 208 H = 240 G = 277 L = 347 P1 = 480 U1 = 600
J = 208 K = 240 P3 = 480 U3 = 600
Model Series 93
Single Phase
Three Phase
Features
• Leed and green compliance, 1 and 3 phase applications
• Industrial or commercial applications
• Standard color: Bankers Bronze (powder coated)
• Also available in other standard TPI colors and custom colors for an additional charge
• Uni-lock construction for snap t 2 piece installation
• Temperature control can be in-built or wall mounted
• Thermal protection by full length manual reset linear limits
• Optional accessories include: duplex receptacle, and inside
or outside corner sections for wall to wall custom t.
• Additional charges may be incurred if changes are made after production has begun - consult factory.
E 93 96 B 250 3 ITS PD
Heater Length (inches) 28, 36, 48, 60, 72, 84, 96, 108, or 120
Inlet B = Bottom F = Front
Watts Per Foot Per Element 100, 125, 150, 165, 187, 200, or 250
# of Elements 100, 125, 150, 165, 187, 200, or 250
Control Options Refer to Pg. 60 of TPI Heat catalog.
Factory Installed Accessories PD = Pedestal DR = Receptacle WM = Screen
Note: 480V single phase units minimum 36” heated length; 600V single phase units minimum 48” heated length 347-480-600 single phase and all three phase units are built with low voltage option factory installed
Product Description
TECHNICAL INFORMATION
Air Intake Bottom / Front
Air Discharge Top
Min Mounting Height 3” for bottom intake / 0” for front intake
Max Watts / Foot 750
Max Allowable Amps 25 without relay, 40 with relay
Voltage / Phase
120V/208V/240V/277V/347V,480V,600V Single Phase
208V,240V,480V,600V Three Phase
Standard Models
MODEL
UNIT
LENGTH
9328 28” 776
9336 36” 816 65
9348 48” 920 70
9360 60” 1022 75
9372 72” 1097 80
Heater
9384 84” 1173 85
9396 96” 1237 90
93108 108” 1298 95
93120 120” 1382 100
Note: All models are suitable for International use Note: Extended enclosure per foot is 100 dollars.
LIST
BACK ADDER
FINISHED
60
MODEL
93BS012 12” 318 55
93BS024 24” 373 60
93BS036 36” 419 65
93BS048 48” 485 70
93BS060 60” 542 75
93BS072 72” 586 80
93BS084 84” 643 85
Blank Section
93BS096 96” 700 90
93BS108 108” 756 95
93BS120 120” 811 100
UNIT
LENGTH
LIST
BACK ADDER
FINISHED
Height 7.5”
Depth 6.15”
Length 28” to 120” in 1’ increments
Cabinet Material
Material Gauge
Optional Controls That
Can Be Built Into Unit
TECHNICAL INFORMATION
Aluminum
12
Thermostat, Disconnect Switch, Transformer
(Control Section Required for Relays)
Factory Installed Accessories
SUFFIX DESCRIPTION LIST
DR
PD
WM 1/4” wire mesh under grill
IDS30 30 Amp/240V Disconnect Switch 95 IDS40 40 Amp/600V Disconnect Switch 95
Note: If using line voltage thermostat on 1 phase heaters, you cannot exceed 25 Amps due to Amp rating of thermostat. 347, 480, and 600V can use 30 Amps with in-built thermostat.
Duplex Receptacle in 4” Extended
Enclosure (not available with 120” heater)
28” through 60” - 2 Required 139 72” through 96” - 3 Required 210
108” through 120” - 4 Required 278
139
$4.00
Per foot
Field Installed Accessories
MODEL DESCRIPTION LIST
9300IC Inside Corner Section 90° or 135°
9300OC Outside Corner Section 90° or 135°
9300EC Right or Left End Cap 85
223
Page 59
Ø .395 (TYP)
3
1
16
"
TYP
PEDESTAL BASE
3"
2
15
16
2
7
16
"
"
Ø .395 (TYP)
3
1
16
"
TYP
PEDESTAL BASE
3"
7.500
6.15
2
15
16
7.500
6.15
3" MINIMUM
FINISHED FLOOR
2
7
16
"
"
12.0
9300 Series - Radius Front Draft Barrier Heater
Product Specications
CABINET
9300 Series shall be constructed of 12 gauge extruded 6063 Aluminum heat treated to T5 hardness. The
uni-lock construction shall allow easy installation and access to back plate for wiring. The snap-t front
cover makes installation and service very simple. Custom factory enclosures to 1/16 inch increments are
built for exact wall to wall t up to 10 foot enclosure lengths. The 12 gauge back plate will have electrical
knockouts for incoming power on each end adjacent to junction box. Pedestal mounted units will have incoming power connection through the pedestal on bottom of unit and will have smooth back for optional
nished back. The die punched front cover will have no screw heads or fasteners.
ELEMENTS
High mass sheathed element construction with Nickel-Chromium resistance wire embedded in compacted
efcient die-electric to ensure proper heat transfer. Aluminum ns mechanically bonded to stainless steel
tube allows for increased surface area and even heat transfer.
LIMIT CONTROLS
Manual reset hydraulic thermal overload covers full length of heating element and shuts down heater when safe operating temperatures are exceeded.
WIRING
Wiring shall be in either end of the enclosure. Wiring can be in the junction box or optional control section if additional controls are needed. Pedestal mounted units shall have 1-1/4” hole through the pedestal and in the bottom of the enclosure for incoming power wiring. All heaters have a factory supplied built in raceway for wiring from either end of the heater or for wiring of continuous heater connections.
59
CONTROLS
Optional controls include single or double pole thermostat and disconnect switch that are factory wired in enclosed junction box on each end of heater enclosure. Relay, transformer relay and duplex receptacle options shall be mounted in extended length control section. Control section will add to heater enclosure length. The control section for the duplex receptacle will add 4” to enclosure length. The control section for other optional components or combinations of components will have two options (6” or 12”) depending on controls required.
APPLICATION
The 9300 series is ETL listed for commercial or industrial applications on all units up to 750 Watts per foot on all units. 3 Phase units have a minimum of 300 Watts per foot.
Product Dimensions
OUTSIDE CORNER SECTION
12.0
12.0
7.500
3" MINIMUM
6.15
7.500
FINISHED FLOOR
6.15
Ø .395 (TYP)
3"
7
"
2
16
TYP
PEDESTAL BASE
1
"
3
16
INSIDE CORNER SECTION
Page 60
60
Draft Barrier Heaters - General Product Information
All Draft Barrier Heaters, unless otherwise noted, are build to order items. Consult factory for lead times.
Additional charges may be incurred if changes are made after production has begun - consult factory.
Electric Draft Barrier Features
• “UNI-LOCK” construction allows snap-t, 2 piece installation
• Heavy Gauge Aluminum Extruded enclosures, 6063 heat treated to T-5 hardness a. DBT/DBF & RDBT-PD-12 gauge front & back b. DBCT/DBCF- 10 gauge Front & Back c. CB-14 gauge Front & Back
• ASHDB Series is 16 gauge Steel Front with 18 Steel gauge back
• 1/4” pencil proof discharge louvers
How To Designate A Model
Digit (Example) MODEL NUMBER DESIGNATION - “ASI” DRAFT BARRIER
Digit 1= DBT Series Model Number ( DBT/DBF, CB, Etc.)
Use if Pedestals are Required*
Digit 2= PD
Digit 3= 4
Digit 4= 250
Digit 5= ITS (etc)
Completed example: DBT-PD-4250-ITS
(for extended enclosure, specify amount of required enclosure on
order write up, IE: 4’ Heated length w/ 2’6” of extended enclosure)
on specic models, refer to catalogue page to verify maximum WPF)
Wattage per Linear foot ( may not exceed allowable wattages
Control Options ; Refer to List Price chart for available options
( Verify on each model which options may be factory installed )
2’ to 5’ Heaters require 2 pedestals
6’ to 8’ Heaters require 3 pedestals
9’ & 10’ Heaters require 4 pedestals
Heated Length of Heater
Voltage & Wattage Specication
• Thermal protection by full length linear limits
• Multiple heaters, factory wired on same back plate, available in up to 10’ lengths
• Totally enclosed junction boxes
• Custom colors and nishes available (See Chart )
• Enclosures available for hydronic heating coils (consult factory for more information )
NOTE:
• Extended enclosures and Blank Sections are NOT punched. When a Control
Section is specied, ALWAYS
allow for an extended enclosure to compensate for the 6” or 12” length of the Section required.
• Note on order when nished
backs are required and add list adder to model list.
Total heater amperage must
not exceed the 25-Amp rating of the high temperature limit at any voltage or wattage. This applies to all Sill Line Model Series.
Voltage Standard Wattages Per Foot Heater Lengths
120-277 100, 125, 150, 165, 187, 200, 250*, 300, 333*, 375* 2’ through 10’
*Units with Extended Enclosures may require more Pedestals than standard length, must verify length of heater after extended enclosures for
total amount of pedestals. NOTE: All bottom inlet units must be mounted a minimum of 3 inches above nished oor.
Dual element models DBCT/DBCF and ASHDB. All elements are single phase. Consult factory for more information.
Control Options
Sufx Designation Description List Adder
CS 6 6” control section / will contain up to 2 control options
CS 12 12” control section / will contain up to 3 control options
ITS Single Pole, 25 Amp integral thermostat, 120,208,240 & 277 Volts 70
ITD Double Pole, 25 Amp integral thermostat, 120,208,240 & 277 Volts 76
IDS Double Pole Disconnect, 20 Amp, 120, 208, 240 & 277 Volts 70
IDS 30 30 Amp disconnect (9300 Series) 95
IDS 40 40 Amp disconnect (9300 Series) 75
LVTR Low voltage controls (trans & relay) 200
PR 120-277/24
PR 120-277/240
ATR*
* Not suitable for International use Note: Please refer to each model to verify how many controls may be integrally mounted, Control sections
will add length to the heater. Must use control section with PR 240/24, PR 208/24, 208/208 and ATR
Note: If using line voltage thermostat on single phase heaters you cannot exceed 25 Amps due to Amp rating of thermostat. 347, 480, and 600V models can use up to 30 Amps with in-built thermostat.
Power Relay, 18 Amp tested, Must specify coil voltage
Single Pole
Single Pole, rated 25 Amps, 120 to 240 Volts,
Contacts rated up to 277 Volts (must specify )
Coils are 24 Volt; 24 Volt transformer
48
95PR 120-277/120
302
CUSTOM PAINT COLORS
Durable Powder Coat Paint Finish
COLOR SIZE LIST
Bankers Bronze (Standard) ---
Eggshell White
Black
Gray
Beige
Simulated Bronze
or Clear Anodized
Special Colors 5lb Increment - Consult
ANODIZING CHARGES
204R1 Clear 313R1 Bronze or
Under 100 feet 571
100 feet - 200 feet 390
Over 200 feet ---
Under 100
Factory
Black
feet
96
LIST
ADDER
Page 61
DBF / DBT Series
DBCT / DBCF Series
Manufactured in U.S.A.Manufactured in U.S.A.
61
DBT Wall Mount
Model-300 WPF Max.
DBF Floor Mount
Model-250 WPF Max.
Cabinet Dimensions: 3-1/2” x 6” x 10’ Maximum Length
Not suitable for residential applications. Built to order:
consult factory for lead time.
LIST
MODEL
DBF-2/DBT-2
DBF-3/DBT-3
DBF-4/DBT-4
DBF-5/DBT-5
DBF-6/DBT-6
DBF-7/DBT-7
DBF-8/DBT-8
DBF-9/DBT-9
DBF-10/DBT-10
Extended Enclosure per foot
DBF/DBT-100BS
DBF/DBT-200BS
DBF/DBT-300BS
DBF/DBT-400BS
DBF/DBT-500BS
DBF/DBT-600BS
DBF/DBT-700BS
DBF/DBT-800BS
DBF/DBT-900BS
DBF/DBT-1000BS
DBF/DBT IC / Inside Corner Section
DBF/DBT OC / Outside Corner Section
180 - 270 Degrees - 6” longest side
DBF/DBT ECR / Right Hand End Cap
DBF/DBT ECL / Left Hand End Cap
DBF/DBT IECR / Inside Fitting Right End Cap
DBF/DBT IECL / Inside Fitting Left End Cap
DBF/DBT WT / 2”- 6” Wall Trim
DBF/DBT SP / 1 1/2” Splice Plate
DBF/DBT MF / Mullion Front up to 1’
DBF/DBT IF / Inside Filler up to 1’
3/4” Conduit Raceway (standard is 1/2”)
Mesh / 1/4” Wire Mesh under Grill
Pedestals - specify 2” or 3”
Clear Anodized Color Anodized Painted Bronze
Finished
Heater
LENGTH
2’ 404 103 434 129 334 40
3’ 497 145 551 177 394 55
4’ 603 182 651 227 462 50
5’ 717 220 785 276 544 56
6’ 868 259 902 325 664 62
7’ 982 302 1007 380 741 74
8’ 1095 342 1115 38 819 78
9’ 1216 384 1354 484 906 90
10’ 1278 430 1504 538 980 98
1’ 141 76 156 100 103 36
2’ 223 103 253 129 156 40
3’ 302 145 353 177 204 47
4’ 384 183 450 227 253 50
5’ 469 220 551 276 302 56
6’ 551 259 651 325 351 62
7’ 638 302 753 380 408 74
8’ 726 342 906 430 462 78
9’ 814 384 961 484 515 90
10’ 849 910 1104 538 594 98
Accessories
DESCRIPTION
90 - 180 Degrees
See Chart for required amount per Heater
Back
Adder
87 98 48
Blank Section
Finished
Heater
Back Adder
Clear
Anodized
342 470 187
70 70 64
88 95 70
64 95 45
90 100 75
$64.00 per Pedestal
Heater
Color
Anodized
LIST
$6.00 per foot
$7.00 per foot
Back Adder
Finished
Painted
Bronze
NOTE: DBF/DBT Series will permit a Thermostat mounted on one side and a Disconnect on the other side, more or other controls require a 6” or 12” control section. Typically, thermostats are mounted on left side of heater. Control Section will add to length of heater.
DBCT Wall Mount
Model-750 WPF Max.
DBCF Floor Mount
Model-600 WPF Max.
Cabinet Dimensions: 5” x 7” x 10’ Maximum Length
Not suitable for residential applications. Built to order:
consult factory for lead time.
LIST
MODEL / LENGTH
DBCT-2/DBCF-2
2’
DBCT-3/DBCF-3
3’
DBCT-4/DBCF-4
4’
DBCT-5/DBCF-5
5’
DBCT-6/DBCF-6
6’
DBCT-7/DBCF-7
7’
DBCT-8/DBCF-8
8’
DBCT-9/DBCF-9
9’
DBCT-10/DBCF-10
10’
Extended Enclosure per foot
DBCT/DBCF-100BS 1’ DBCT/DBCF-200BS 2’ DBCT/DBCF-300BS 3’ DBCT/DBCF-400BS 4’ DBCT/DBCF-500BS 5’ DBCT/DBCF-600BS 6’ DBCT/DBCF-700BS 7’ DBCT/DBCF-800BS 8’ DBCT/DBCF-900BS 9’
DBCT/DBCF-1000BS 10’
DBCT/DBCF IC / Inside Corner Section
DBCT/DBCF OC / Outside Corner Section
180 - 270 Degrees - 6” longest side
DBCT/DBCF ECR / Right End Plate
DBCT/DBCF ECL / Left End Plate
DBCT/DBCF IECR/ Right End Plate (inside t) DBCT/DBCF IECL/ Left End plate (inside t)
DBCT/DBCF WT / Wall Trim 2” - 6”
DBCT/DBCF SP / 1 1/2” Splice Plate
DBCT/DBCF IF / Inside Filler (up to 1’)
3/4” Conduit Raceway (standard is 1/2”)
Mesh / 1/4” Wire Mesh under Grill
Pedestals - specify 2” or 3”
WATTS/
Accessories
DESCRIPTION LIST
90 - 180 Degrees
Clear Anodized Color Anodized Painted Bronze
FT.
to 250
251-750
to 250
251-750
to 250
251-750
to 250
251-750
to 250
251-750
to 250
251-750
to 250
251-750
to 250
251-750
to 250
251-750
See Chart for required amount per Heater
Finished
Heater
Back
Adder
532
133
627 651 538
555
189
768 811 638
808
240
744 973 750
959
300
1081 1136 863
1153
353
1292 1355 1025
1338
404
1461 1537 1152
1482
466
1613 1701 1259
1648
513
1767 1866 1369
1766
573
1919 2028 1482
105 115 70
Blank Sections
166 93 177 119 120 27
302 132 319 162 2 11 47
430 187 473 220 300 55
562 204 603 283 387 67
689 220 728 353 460 78
823 259 854 420 560 90
952 404 1038 484 647 98
1085 468 1127 549 737 109
1218 513 1259 642 823 120
1349 574 1393 679 911 132
Finished
Heater
Back
Adder
560
161
715
218
849
283
1018
353
1218
420
1415
483
1569
549
1743
642
1919
679
Clear
Anodized
Anodized
429 587 249
70 70 64
141 161 55
141 161 83
90 105 67
$6.00 per foot
$7.00 per foot
$64.00 per Pedestal
Color
Heater
445
538
631
741
888
1030
1132
1262
1369
Finished
Back
Adder
47
55
68
78
90
98
109
120
133
Painted
Bronz
NOTE: DBCT/DBCF Series will permit a Thermostat mounted on one side and Disconnect on the other side, more or other controls require a 6” or 12” control section. Typically, Thermostats are mounted on left side of heater. Control Section will add to the length of heater.
Page 62
62
HEATER
BLANK
SECTION
DBTS Series Draft Barrier Heaters
Features
• Bottom air intake.
• Maximum watts per foot: 300.
• Dimensions: Depth 2-5/8'” x Height 4" Length 2’ to 10'.
• 14 gauge Aluminum housing.
• Voltages: 120V / 208V / 240V / 277V - 1 Phase
• No controls can be added without adding a control section and extended enclosure.
Manufactured in U.S.A.
Standard Models
MODEL LENGTH
DBTS-2 2’ 380 105 414 129 314 40
DBTS-3 3’ 501 142 499 177 360 47
DBTS-4 4’ 547 183 589 227 414 50
DBTS-5 5’ 633 223 684 276 480 56
DBTS-6 6’ 769 259 836 325 549 62
DBTS-7 7’ 879 302 941 380 633 74
DBTS-8 8’ 951 342 1043 430 691 78
DBTS-9 9’ 1061 384 1157 484 762 91
DBTS-10 10’ 1162 430 1273 538 836 103
Extended Enclosure per foot 70 78 36
DBTS-100BS 1’ 118 67 129 87 84 36
DBTS-200BS 2’ 183 105 211 129 117 40
DBTS-300BS 3’ 249 142 282 177 149 47
DBTS-400BS 4’ 314 183 355 227 183 50
DBTS-500BS 5’ 380 223 431 276 214 56
DBTS-600BS 6’ 443 259 510 325 249 62
DBTS-700BS 7’ 511 302 586 380 301 74
DBTS-800BS 8’ 571 342 679 430 314 78
DBTS-900BS 9’ 643 384 1098 484 346 91
DBTS-1000BS 10’ 713 430 819 538 576 103
CLEAR ANODIZED COLOR ANODIZED PAINTED BRONZE
HEATER
FINISHED
BACK ADDER
Not suitable for residential applications. 300
watts per foot maximum. Built to order:
consult factory for lead time.
LIST
HEATER
FINISHED
BACK ADDER
HEATER
BACK ADDER
FINISHED
Accessories
MODEL DESCRIPTION
DBTS IC
DBTS OC
DBTS ECR Right Hand End Cap
DBTS ECL Left Hand End Cap
DBTS IECR Inside Fitting Right End Cap
DBTS IECL Inside Fitting Left End Cap
DBTS WT Wall Trim 2” - 6” 64 95 45
DBTS SP Splice Plate 1 1/2” 64 95 45
DBTS MF Mullion Front up to 1’ 64 78 45
Note on order
Inside Corner Section
90° - 180°
Outside Corner Section
180° - 270° - 6” longest side
1/2” Conduit Raceway Standard
Mesh 1/4” Wire Mesh under grill $7.00 per foot
Pedestals - specify 2” or 3” $64.00 per Pedestal
CLEAR ANODIZED COLOR ANODIZED PAINTED BRONZE
342 473 187
342 473 187
70 70 64
84 95 70
LIST
Page 63
RDBT Series ASHDB Series
Cabinet Dimensions: 7” x 6” x 10’
Maximum Length
Not suitable for residential
applications. 300 Watts Per Foot
Maximum. Pedestals included with
unit. Rounded enclosure with at
top discharge. Special Build: consult
Manufactured in U.S.A.
factory for lead time.
LIST
MODEL LENGTH
RDBT-PD-2 2’ RDBT-PD-3 3’ RDBT-PD-4 4’ RDBT-PD-5 5’ RDBT-PD-6 6’ RDBT-PD-7 7’ RDBT-PD-8 8’ RDBT-PD-9 9’
RDBT-PD-10 10’
Extended Enclosure per foot
Clear
Anodized
Color
Anodized 750 819 557 954 1045 658
1174 1308 777 1400 1567 905 1633 1833 1045 1868 2102 1181 2103 2367 1317 2340 2638 1452 2577 2909 1611
167 193 87
Painted
Bronze
Blank Sections
RDBT-PD-100BS 1’ RDBT-PD-200BS 2’ RDBT-PD-300BS 3’ RDBT-PD-400BS 4’ RDBT-PD-500BS 5’ RDBT-PD-600BS 6’ RDBT-PD-700BS 7’ RDBT-PD-800BS 8’ RDBT-PD-900BS 9’
RDBT-PD-1000BS 10’
Accessories
Description
423 453 309 566 721 408 840 939 515
1043 1220 620 1257 1422 726 1464 1584 833 1673 1813 937 1887 2048 1045 2093 2276 1150 2304 2508 1276
Clear
Anodized
Color
Anodized
Painted
Bronze
LIST
RDBT-PDIC / Inside Corner Section
RDBT-PDOC / Outside Corner Section
90 - 180 Degrees
66 75 54
180 - 270 Degrees - 6” longest side
RDBT-PDIECR/Inside Fitting Right End Cap
RDBT-PDIECL/Inside Fitting Left End Cap
3/4” Conduit Raceway (standard is 1/2”)
Mesh - 1/4” Wire Mesh under Grill
164 213 95
$6.00 per Foot $7.00 per Foot
NOTE: RDBT-PD Series will permit a Thermostat mounted on one side and a Disconnect on the other side. More or other controls require a 6” or 12” control section. Typically, Thermostats are mounted on the left side of heater. Control Sections will add to length of heater.
CB Series
LIST
Clear Anodized Color Anodized Painted Bronze
Finished
Heater
Back
Adder
365 105 384 129 298 40 440 142 473 177 342 47 515 183 560 227 384 50 594 223 647 276 430 56 730 259 798 325 532 62 814 302 888 380 586 74 902 342 988 430 638 78 988 384 1088 493 691 91
1074 430 1186 538 748 103
64 74 30
Blank Sections 110 76 122 100 78 36 183 105 191 129 105 40 230 142 263 177 132 47 288 183 334 227 162 50 353 223 404 276 186 56 414 259 479 325 214 62 479 302 557 380 247 74 545 342 632 430 282 78 613 384 715 493 319 91 684 430 798 538 328 103
Heater
Finished
Back
Adder
Heater
Manufactured in U.S.A.
Not suitable for residential
applications. Bottom inlet
only. Built to order: consult
factory for lead time.
Cabinet Dimensions: 2-5/8” x 4-1/2” x 10’
Maximum Length
NOTE: CB Series will permit either a Thermostat or a Disconnect on only one side of the heater. More or other controls require a control section. Typically, Thermostats are mounted on the right side of heater. Control Sections will add to length of heater.
Model Length
CB-2 2’ CB-3 3’ CB-4 4’ CB-5 5’ CB-6 6’ CB-7 7’ CB-8 8’ CB-9 9’
CB-10 10’
Extended Enclosure
per foot
CB-100BS 1’ CB-200BS 2’ CB-300BS 3’ CB-400BS 4’ CB-500BS 5’ CB-600BS 6’ CB-700BS 7’ CB-800BS 8’ CB-900BS 9’
CB-1000BS 10’
Finished
Back
Adder
Not suitable for residential applications.
500 Watts per foot maximum. 16 gauge
Steel enclosure, 18 gauge backplate.
Heights may vary from 8” up to 20.”
Bottom Intake / Top Discharge. Special
build - consult factory for lead time.
Cabinet Dimensions: 5-1/2” x 8”
thru 20” x 10’ Maximum Length.
Cannot be Anodized
MODEL / LENGTH
ASHDB-2
2’
ASHDB-3
3’
ASHDB-4
4’
ASHDB-5
5’
ASHDB-6
6’
ASHDB-7
7’
ASHDB-8
8’
ASHDB-9
9’
ASHDB-10
10’
Extended Enclosure per foot 51 65 78
ASHDB-8/20-100BS 1’ 143 43 174 64 183 74 ASHDB-8/20-200BS 2’ 194 48 228 67 276 77 ASHDB-8/20-300BS 3’ 253 50 283 83 356 80 ASHDB-8/20-400BS 4’ 278 55 346 76 440 86 ASHDB-8/20-500BS 5’ 330 60 404 78 521 90 ASHDB-8/20-600BS 6’ 393 56 466 110 603 98 ASHDB-8/20-700BS 7’ 462 74 511 90 708 103 ASHDB-8/20-800BS 8’ 504 78 569 95 792 110 ASHDB-8/20-900BS 9’ 562 83 642 100 885 115
ASHDB-8/20-1000BS 10’ 620 90 709 108 914 142
ASHDB IC / Inside Corner Section
ASHDB OC / Outside Corner Section
180 - 270 Degrees - 6” longest side
ASHDB ECR / Right End Cap
ASHDB SP / 1 1/2” Splice Plate ASHDB WT / 2” - 6” Wall Trim
3/4” Conduit Raceway ( standard is 1/2”) $6.00 per Foot
Mesh / 1/4” Wire Mesh under Grill $7.00 per Foot
WATTS/
FT.
to 250 466
251-500 533 587 668
to 250 545
251-500 538 668 538
to 250 615
251-500 684 750 888
to 250 679
251-500 758 836 999
to 250 798
251-500 870 943 1136
to 250 934
251-500 1008 1071 1292
to 250 1090
251-500 1146 1225 1440
to 250 1211
251-500 1283 1376 1594
to 250 1346
251-500 1422 1531 1748
Accessories 8-12” High 13-16” High 17-20” High Description LIST
90 - 180 Degrees
ASHDB ECL / Left End Cap
Pedestals - Specify 2” or 3” $64.00 per Pedestal
NOTE: ASHDB Series will permit a Thermostat mounted on one side and a Disconnect on the other side, more or other controls require a 6” or 12” control section. Typically, Thermostats are mounted on left side of heater. Control Section will add to length of heater.
Accessories
Description LIST
CB IC / Inside Corner Section
90 - 180 Degrees
CB OC / Outside Corner Section
180 - 270 Degrees - 6” longest side
CB ECR / Right End Cap
CB ECL / Left End Cap CB WT / Wall Trim 2” - 6” CB SP / Splice Plate 1 1/2”
CB MF / Mullion Front up to 1’
1/2” Conduit Raceway
Mesh / 1/4” Wire Mesh under Grill
Pedestals - specify 2” or 3”
See Chart for required amount per Heater
8-12” High 13-16” High 17-20” High
Finished
Heater
See Chart for required amount per Heater
Back
Adder
Blank Sections
Manufactured in U.S.A.
LIST
Finished
Heater
Back
Adder
511
48
50
55
60
67
74
1146
78
1299
83
1452
90
305 320 336
74
593
76
676
80
760
84
865
91
990
95
103
108
115
52 83 109
Clear
Anodized
Anodized
342 473 187
70 70 64
64 78 45
64 86 45
Standard
$7.00 per foot
$64.00 per Pedestal
Heater
Color
593
703
809
919
1061
1213
1367
1519
1673
Finished
Back
Adder
95
100
105
109
117
120
127
132
142
Painted
Bronze
63
Page 64
MR Series Heavy Duty Metal Sheath Electric Infrared Heater
64
Heavy Duty Overhead Infrared Heaters for Indoor Spot Heating, Zone or Total Area
Heating Applications
• High-Density radiant heat, with 60° symmetric heat pattern.
Manufactured in U.S.A.
MR-2/4 KW
MR-6/13 KW
MR Series Safety Note
Ground fault protection must be used. To avoid potential hazards use model GF-SK-1 ground fault sensing switch with these heaters. This device is designed to provide a reliable way to quickly terminate power to the heaters in the event of a ground fault occurrence.
Standard Models
UPC#
686334
135177 MR-212-1 1.8* 6,143 120 1 135184 MR-220-1 135214 MR-224-1 240 8.5 135221 MR-227-1 277 7.2 135238 MR-248-1 480 4.2 135245 MR-257-1 600 3.3 135306 MR-420-1 135320 MR-424-1 240 18.8 135337 MR-427-1 277 16.3 135344 MR-448-1 480 9.5 135351 MR-457-1 600 7.5 135368 MR-620-3 135375 MR-624-3 240 14.5 25.0 135382 MR-627-3 277 N/A 21.7 135412 MR-648-3 480 7.5 13.0 135429 MR-657-3 600 5.8 10.0 135115 MR-1320-3 135122 MR-1324-3 240 33.0 135139 MR-1327-3 277 135153 MR-1348-3 480 17.0 29.0 135160 MR-1357-3 600 13.6 135252 MR-2720-3 135269 MR-2724-3 240 64.8 135283 MR-2748-3 480 32.4 135290 MR-2757-3 600 26.7
Note: Some 3-Phase models can be eld converted to single phase operation.
MODEL KW BTU’S VOLTS PHASE
208
2.0 6,826
208
4.5 15,359
208
6.0 20,478
208
13.5 46,076
208
27* 92,151
1
1
3 or 1
3
3 or 1
3
• ETL Listed for suspended high-bay indoor applications
• Rugged straight metal sheath elements installed, great for high vibration areas.
• Gold anodized Aluminum housing for efcient, long term reectivity & corrosion resistance.
• Terminal box with high-temp Silicone wire.
• Single or three phase wiring.
• ”L” brackets included for chain suspension, or rigid mounting.
AMPS
3-Ph 1-Ph
15.0
9.6
N/A
21.6
17.0 29.0
37.5
N/A 48.8
74.8
N/A
N/A
WT.
(Lbs.)
15.0 519 449069 HDWG-4 69
27.0 814 449076 HDWG-6 88
43.0 1261 449083 HDWG-13 151
288.0
Crated
LIST
9.0 410 449090 HDWG-2 57
2715 883047 HDWG-27 307
Optional Wireguards
UPC#
686334
MODEL LIST
Heavy Duty Metal Sheath Infrared Control Options
CONTROL FEATURES:
• (GF-SK-1) Positive “off” and built-in “on/off” rocker switch illuminates “red” during operation.
• Controls cannot be mounted directly on unit. Must use 6” minimum threaded conduit.
UPC
686334
486026 GF-SK-1
589376 DC-SK-1
MODEL DESCRIPTION
Ground Fault
Sensing Switch
Disconnect
Switch
RATING
(VAC)
208V - 600V
50A
120V - 600V
50A
Dimensions (In)
Ht. Wd. Dp.
10.3 10.3 5.0 12 737
5.0 6.0 4.0 5 360
WT.
(lbs.)
LIST
Page 65
MR Series Heavy Duty Metal Sheath Electric Infrared Heater
Note: The MR-27 Series includes (2) Terminal Box Assemblies, located on each end of the heater, requiring an electrical service to each end.
65
MR-27 KW
Manufactured in U.S.A.
MR Series Dimensions & Reector Pattern
DIMENSIONS (in.)
SERIES A B C
LENGTH WIDTH DEPTH
MR-2 28 9 7.25
MR-4 48.5 9 7.25
MR-6 30 19.88 7.5
MR-13 50.5 19.88 7.5
MR-27 96.75 28.25 14.88
60° Symmetric
NOTE: Take into account that the MR Series is designed with a 60° symmetrical
reector heat pattern. The sizing chart can
assist you based upon your mounting height.
Mounting Clearances & Recommended Mounting Height
Mounting Clearances Recommended Mounting Height
24” from ceiling
All MR Models
36” from vertical surface & from another heater
72” from face of heater to combustible surface
MR-27 Only 87” from face of heater to combustible surface 27.0 KW 15’ - 30’
1.8 & 2.0 KW 8’ - 10’
4.5 KW 8’ - 12’
6.0 KW 10’ - 14’
13.5 KW 12’ - 16’
Sizing Chart
Mounting
Height
8’
10’
12’
14’
16’
18’
20’ MR-27 28 23 644 41.9
24’ MR-27 33 27 891 30.3
30’ MR-27 41 32 1312 20.6
Heater
Model
MR-2 8 8 64 31.3
MR-4 9 8 72 62.5
MR-2 11 10 110 18.2
MR-4 11 10 110 40.9
MR-6 12 10 120 50.0
MR-4 12 11.5 138 32.6
MR-6 14 12 168 35.7
MR-13 15 13 195 69.2
MR-6 16 14 224 26.8
MR-13 18 16 288 46.9
MR-6 18 16 288 20.8
MR-13 21 18 378 35.7
MR-27 24 19 456 59.2
MR-13 23 20 460 29.3
MR-27 28 20 560 48.2
Length Wide
Coverage
(Sq. Ft.)
Watts / Sq.
Ft.
Product Specications
Housing:
.040 Gold anodized Aluminum housing for efficient, long-term reflectivity and corrosion resistance. High­density radiant heat. Housing is ETL Listed for indoor, dry environment applications only.
Reflector:
60 degree symmetric heat pattern.
Elements:
Rugged straight metal sheath elements. .430” diameter Incoloy 840 metal sheath. Nickel-Chrome alloy coiled filament imbedded within a Magnesium Oxide insulating powder and threaded end terminations. Available wattages in 1800, 2000, and 4500 Watts per element. Available in standard voltages from 120 to 600 Volts.
Controls:
Heavy Duty, Metal Sheath heaters are not manufactured with any control device on the unit. All controls and accessories should be specified as remote mounted. Please consult the technical sales department of factory for help in determining applicable controls. Please follow installation instructions that accompany each heater.
Accessories:
Wire guards and power contactor panels.
Page 66
TH & THSS Series Mul-T-Mount Electric Infrared Heater
66
Overhead Infrared Heaters for Snow & Ice Control, Outdoor Spot Heating & All Indoor
Heating Applications
Product Description
AVAILABLE IN 2 LAMP BROWN ENAMEL OR STAINLESS STEEL,
OR 3 LAMP STAINLESS STEEL.
• Listed for suspended, totally exposed (outdoor), high-bay (indoor) comfort heating and exterior snow & ice control applications.
• Listed for recessed applications.
• 20 gauge painted steel or stainless steel housings.
• Gold anodized Aluminum reectors & end caps.
• 50% higher Watt densities for 3-element units.
• 2-Lamp wiring, single phase.
• 3-Lamp wiring, three or single phase.
• Stainless steel models have non-corrosive housing, hardware and brackets; no ferrous metals used in the unit. Durable in harsh
Manufactured in U.S.A.
atmospheres & outdoor environments.
• High temperature lead wires.
• Clear Quartz Lamp(s) Included.
New Feature:
In-Built surface mounting brackets
allows for xture adjustment up to
45° horizontal tilt.
Mounting Clearances & Recommended Mounting Height
Mounting Clearances Recommended Mounting Height
2 & 3 Lamp
Models
2 Lamp Models
3 Lamp Models
72” from face of heater to combustible
96” from face of heater to combustible
3” from ceiling
24” from vertical surface
surface
surface
In-built surface
mounting
brackets
attached to
the top wiring
channel.
Product Dimensions
Mul-T­Mount Series Length Width Height Mtg. Ctr.
222 24" 15" 10-7/8" 23-1/2" 342 33" 15" 10-7/8" 32-1/2" 462 46" 15" 10-7/8" 45-1/2" 223 24" 21-1/2" 10-7/8" 23-1/2" 343 33" 21-1/2" 10-7/8" 34" 463 46" 21-1/2" 10-7/8" 45-1/2"
30° Symmetric & A30° Asymmetric Reector -
60° Symmetric & A60° Asymmetric Reector -
30° Symmetric & A30° Asymmetric Reector -
0 to 45o tilt @
15o increments
A B C D
90° Symmetric Reector
Dimensions (in.)
Indoor
Indoor
- Indoor
Outdoor
14’ - 30’
12’ - 18’
8’ - 12’
8’ - 10’
Page 67
TH & THSS Series Mul-T-Mount Electric Infrared Heater
30° Symmetric
60° Symmetric
90° Symmetric
30° Asymmetric
60° Asymmetric
Product SpecicationsReector Patterns
Series: 222, 342, 462 (Painted Version) 2-lamp 222, 342, 462 (Stainless Steel Version) 2-lamp 223, 343, 463 (Stainless Steel Version) 3-lamp
Housing:
20 gauge Galvanized Steel with a baked on, brown enamel (painted) nish. Housing is
ETL Listed for both indoor and totally exposed outdoor applications. 20 gauge Stainless Steel for durability and corrosion-resistance. Housing is ETL Listed for both indoor and totally exposed outdoor applications.
Reectors and End Caps:
.040 Gold anodized Aluminum reectors and end caps for superior reectivity. Five choices of reector patterns including 30 degree narrow (symmetric & asymmetric), 60
degree medium (symmetric & asymmetric), and 90 degree wide (symmetric).
Elements:
Clear quartz lamps. Coiled tungsten lament located within a sealed quartz envelope, halogen lled, with porcelain end caps and 6” wire pigtail leads. 96% radiant delivered efciency with high moisture and thermal shock resistance. Instantaneous heat-up
and cool-down performance. Available wattages from 500 to 3800 Watts per element. Available voltages from 120 to 600 Volts.
Controls:
Mul-T-Mount heaters are not manufactured with any control device on the unit. All
controls are accessories and should be specied as such. Please consult the technical
sales department of factory for help in determining applicable controls. Please follow installation instructions that accompany each heater.
Accessories:
Recessed mounting frames (painted or stainless steel), adjustable mounting brackets (stainless steel only), vertical mounting brackets (stainless steel only), wire guards, thermostats, snow detectors, SCR controllers, and power contactor panels.
67
Sizing Chart
Mounting Heights (FT.) Watts Delivered per Square Foot
8 10 12 14 16 18 20
Reective
30º 3.2
60º 3.2 10.5 x 9.5 13 x 12 15 x 14 17 x 16
90º 3.2 17 x 16 21 x 20 N / R N / R 11.8 7.6 - - - - -
30º 5.0 6 x 4 7.5 x 5.5 8.5 x 6.5 9.5 x 7.5 10.5 x 8.5 11.5 x 9.5 12.5 x 10.5 208.3 121.2 90.5 70.2 56.0 45.8 38.1
60º 5.0 11.5 x 9.5 14 x 12 16 x 14 18 x 16 20.5 x 18.5 23 x 21
90º 5.0 18 x 16 22 x 20 26 x 24 N / R N / R N / R 17.4 11.4 8.0 - - - -
30º 7.3 N / R 8.5 x 5.5 9.5 x 6.5 10.5 x 7.5 11.5 x 8.5 12.5 x 9.5 13.5 x 10.5 - 156.1 118.2 92.7 74.7 61.5 51.5
60º 7.3 12 x 10.5 15 x 12 17 x 14 19 x 16 21.5 x 18.5 24 x 21
90º 7.3 19 x 16 23 x 20 27 x 24 N / R N / R N / R 24.0 15.9 11.3 - - - -
30º 4.8
60º 4.8 10.5 x 10.5 13 x 13 15 x 15 17 x 17 21 x 21
90º 4.8 17 x 17 21 x 21 N / R N / R N / R 16.6 10.9 - - - - -
30º 7.5 N / R 7.5 x 6.5 8.5 x 7.5 9.5 x 8.5 10.5 x 9.5 11.5 x 10.5 12.5 x 11.5 - 153.8 117.6 92.9 75.2 62.1 52.2
60º 7.5 11.5 x 10.5 14 x 13 16 x 15 18 x 17 20.5 x 19.5 23 x 22
90º 7.5 18 x 17 22 x 21 26 x 25 N / R N / R N / R 24.5 16.2 11.5 - - - -
30º 10.95 N / R 8.5 x 6.5 9.5 x 7.5 10.5 x 8.5 11.5 x 9.5 12.5 x 10.5 13.5 x 11.5 - 198.2 153.7 122.7 100.2 83.4 70.5
60º 10.95 12 x 11 15 x 13 17 x 15 19 x 17 21.5 x 19.5 24 x 22 N / R 83.0 56.2 42.9 33.9 26.1 20.7 -
90º 10.95 19 x 17 23 x 21 27 x 25 N / R N / R N / R N / R 33.9 22.7 16.2 - - - -
(kW)
Pattern ( º )
Heater Output
# of Qtz. Lamps
L x W L x W L x W L x W L x W L x W L x W
5.5 x 4 6.5 x 5.5 7.5 x 6.5 8.5 x 7.5 9.5 x 8.5 10.5 x 9.5 11.5 x 10.5
2 - Quartz Lamp Heaters
5.5 x 5 6.5 x 6.5 7.5 x 7.5 8.5 x 8.5 9.5 x 9.5 10.5 x 10.5 11.5 x 11.5 174.5 113.6 85.3 66.4 53.2 43.5 36.3
3 - Quartz Lamp Heaters
Heat Pattern Coverage @ Floor Level
N / R N / R N / R
N / R
N / R
N / R N / R
N / R
8 10 12 14 16 18 20
145.5 89.5 65.6 50.2 39.6 32.1 26.5
32.1 20.5 15.2 11.8 - - -
45.8 29.8 22.3 17.4 13.2 10.4 -
57.9 40.6 30.7 24.0 18.4 14.5 -
43.5 28.4 21.3 16.6 10.9 - -
62.1 41.2 31.3 24.5 18.8 14.8 -
Mounting Heights (FT.)
Page 68
TH & THSS Series Mul-T-Mount Electric Infrared Heater
68
2 Lamp Mul-T-Mount Series
Brown Enamel Or Stainless Steel With 2 Clear Quartz Lamps Included
BROWN HOUSING
UPC#
686334
444163 222-30-TH-208V 444408 222-30-THSS-208V
444170 222-30-TH-240V 444415 222-30-THSS-240V 240 63016249
444187 222-30-TH-277V 444422 222-30-THSS-277V 277 63016279
481380 222-30-TH-480V 481434 222-30-THSS-480V 480 63016489
444194 222-A30-TH-208V 444439 222-A30-THSS-208V 208
444200 222-A30-TH-240V 444446 222-A30-THSS-240V 240 63016249
444217 222-A30-TH-277V 444453 222-A30-THSS-277V 277 63016279
481410 222-A30-TH-480V 481465 222-A30-THSS-480V 480 63016489
444224 222-60-TH-208V 444460 222-60-THSS-208V 208
444231 222-60-TH-240V 444477 222-60-THSS-240V 240 63016249
444248 222-60-TH-277V 444484 222-60-THSS-277V 277 63016279
481397 222-60-TH-480V 481441 222-60-THSS-480V 480 63016489
444255 222-A60-TH-208V 444491 222-A60-THSS-208V 208
444262 222-A60-TH-240V 444507 222-A60-THSS-240V 240 63016249
444279 222-A60-TH-277V 444514 222-A60-THSS-277V 277 63016279
481427 222-A60-TH-480V 481472 222-A60-THSS-480V 480 63016489
443296 222-90-TH-208V 444521 222-90-THSS-208V 208
444286 222-90-TH-240V 444538 222-90-THSS-240V 240 63016249
444293 222-90-TH-277V 444545 222-90-THSS-277V 277 63016279
481403 222-90-TH-480V 481458 222-90-THSS-480V 480 63016489
481083 342-30-TH-208V 480932 342-30-THSS-208V
481090 342-30-TH-240V 480949 342-30-THSS-240V 240 63025249
802611 342-30-TH-480V 802635 342-30-THSS-480V 480 63025489
481175 342-A30-TH-208V 481021 342-A30-THSS-208V 208
481182 342-A30-TH-240V 481038 342-A30-THSS-240V 240 63025249
444316 342-A30-TH-480V 444569 342-A30-THSS-480V 480 63025489
481113 342-60-TH-208V 480963 342-60-THSS-208V 208
481120 342-60-TH-240V 480970 342-60-THSS-240V 240 63025249
802918 342-60-TH-480V 802932 342-60-THSS-480V 480 63025489
481205 342-A60-TH-208V 481052 342-A60-THSS-208V 208
481212 342-A60-TH-240V 481069 342-A60-THSS-240V 240 63025249
444330 342-A60-TH-480V 444583 342-A60-THSS-480V 480 63025489
481144 342-90-TH-208V 480994 342-90-THSS-208V 208
481151 342-90-TH-240V 481007 342-90-THSS-240V 240 63025249
803212 342-90-TH-480V 803236 342-90-THSS-480V 480 63025489
802710 462-30-TH-480V 802734 462-30-THSS-480V
444361 462-A30-TH-480V 444613 462-A30-THSS-480V 30° Asymmetrical 63036489
803014 462-60-TH-480V 803038 462-60-THSS-480V 7.3 60° Symmetrical 63036489
444385 462-A60-TH-480V 444637 462-A60-THSS-480V 60° Asymmetrical 63036489
803311 462-90-TH-480V 803335 462-90-THSS-480V 90° Symmetrical 63036489
MODEL
NOTE: Consult the factory, the product instruction manual, or a licensed electrician for 3-phase wiring of all 2-element heaters.
STAINLESS STEEL
HOUSING
UPC#
686334
KW BTU’S VOLTS
MODEL Brown
3.2 10,922
5.0 17,065
24,915 480
REFLECTOR
PATTERN
208
30° Symmetrical
30° Asymmetrical
60° Symmetrical
60° Asymmetrical
90° Symmetrical
208
30° Symmetrical
30° Asymmetrical
60° Symmetrical
60° Asymmetrical
90° Symmetrical
30° Symmetrical 63036489
Replacement
Element
63016209
63016209
63016209
63016209
63016209
63025209
63025209
63025209
63025209
63025209
WT.
(Lbs.)
20 631 762
25 832 1066
32 1045 1281
LIST
Stainless
Steel
Page 69
TH & THSS Series Mul-T-Mount Electric Infrared Heater
3 Lamp Mul-T-Mount Series
Brown Enamel Or Stainless Steel Housing With 3 Clear Quartz Lamps Included
NOTE:
• 600-Volt Models also available, contact factory for more information.
• Asymmetrical pattern units are also available for 30° & 60°
Manufactured in U.S.A.
BROWN HOUSING
UPC#
686334
487481 223-30-TH-208V 443678 223-30-THSS-208V 487498 223-30-TH-240V 443685 223-30-THSS-240V 240 63016249 487504 223-30-TH-277V 443692 223-30-THSS-277V 277 63016279 487511 223-30-TH-480V 481588 223-30-THSS-480V 480 63016489 487528 223-60-TH-208V 443289 223-60-THSS-208V 208 487535 223-60-TH-240V 443739 223-60-THSS-240V 240 63016249 487542 223-60-TH-277V 443746 223-60-THSS-277V 277 63016279 487559 223-60-TH-480V 481595 223-60-THSS-480V 480 63016489 487566 223-90-TH-208V 443784 223-90-THSS-208V 208 487573 223-90-TH-240V 443791 223-90-THSS-240V 240 63016249 487580 223-90-TH-277V 443807 223-90-THSS-277V 277 63016279 487597 223-90-TH-480V 481601 223-90-THSS-480V 480 487603 343-30-TH-208V 481236 343-30-THSS-208V 487610 343-30-TH-240V 481243 343-30-THSS-240V 240 63025249 487627 343-30-TH-480V 811439 343-30-THSS-480V 480 63025489 487634 343-60-TH-208V 481267 343-60-THSS-208V 208 487641 343-60-TH-240V 481274 343-60-THSS-240V 240 63025249 487658 343-60-TH-480V 811637 343-60-THSS-480V 480 63025489 487665 343-90-TH-208V 481298 343-90-THSS-208V 208 487672 343-90-TH-240V 481304 343-90-THSS-240V 240 63025249 487689 343-90-TH-480V 811835 343-90-THSS-480V 480 63025489 487696 463-30-TH-480V 810531 463-30-THSS-480V 487702 463-60-TH-480V 810739 463-60-THSS-480V 10.95 60° Sym. 63036489 487719 463-90-TH-480V 810937 463-90-THSS-480V 90° Sym. 63036489
MODEL
STAINLESS STEEL
HOUSING
UPC#
686334
208
208
480
REFLECTOR
PATTERN
30°
Symmetrical
60°
Symmetrical
90°
Symmetrical
30°
Symmetrical
60°
Symmetrical
90°
Symmetrical
30° Sym. 63036489
KW BTU’S VOLTS
MODEL Brown
4.8 16382
7.5
25298
37372
Replacement
Element
63016209
63016209
63016209
63016489 63025209
63025209
63025209
WT.
(Lbs.)
25 1032 1163
33 1248 1482
41 1499 1735
LIST
Stainless
69
Steel
TH & THSS Series Product Accessories
UPC#
686334
881128 VMB-41-SS Wall Mounting Brackets (2) All Mul-T-Mount Models 12 208 851152 CHWG-222
851145 CHWG-342 342 Series 74 851626 CHWG-462 462 Series 101 854368 CHWG-223 223 Series 69 854351 CHWG-343 343 Series 90 854344 CHWG-463 463 Series 105
441995 RMF-222-SS-A 27 x 17-7/8 29-1/8 x 20 222 Series Stainless 449441 RMF-222-A 27 x 17-7/8 29-1/8 x 20 222 Series Painted 168 442077 RMF-342-SS-A 36 x 17-7/8 38-1/8 x 20 342 Series Stainless 441872 RMF-342-A 36 x 17-7/8 38-1/8 x 20 342 Series Painted 169 442107 RMF-462-SS-A 49 x 17-7/8 51-1/8 x 20 462 Series Stainless 449458 RMF-462-A 49 x 17-7/8 51-1/8 x 20 462 Series Painted 215
881104 RMF-223-SS 32 x 29-3/8 34-1/8 x 31-1/2 223 Series Stainless 15 349
881135 RMF-343-SS 41 x 29-3/8 43-1/8 x 31-1/2 343 Series Stainless 18 410
88 1111 RMF-463-SS 54 x 29-3/8 56-1/8 x 31-1/2 463 Series Stainless 20 500 487726 RMF-223 32 x 29-3/8 34-1/8 x 31-1/2 223 Series Painted 15 280 487733 RMF-343 41 x 29-3/8 43-1/8 x 31-1/2 343 Series Painted 18 294 487740 RMF-463 54 x 29-3/8 56-1/8 x 31-1/2 463 Series Painted 20 366 440783 31939009 440738 31940009 Reduces Quartz Lamp All 2500W Qtz. Lamp 112 440745 31941009 446150 632-1620 Red Quartz Lamps; 1.6kw, 208v 446167 632-1624 Red Quartz Lamps; 1.6kw, 240v 144 446228 632-2548 Red Quartz Lamps; 2.5kw, 480v 342 & 343 Series 169
MODEL DESCRIPTION FOR USE WITH
222 Series
Stainless Steel Wire Guards
Recessed Mounting Frames (UL)
Ceiling Cutout (in.) Frame Size (in.)
Red Vycor Sleeves
Brightness by 90%
All 1600W Qtz. Lamp
All 3650W Qtz. Lamp 138
222,223 & RPH Series
WT.
(LBS.)
2
6
9
11
2
2
LIST
56
230
285
349
85
144
Page 70
70
OCH Series Outdoor / Indoor Rated Quartz Electric Infrared Heater
Features
• Frosted Quartz Tube heating element (included)
• Listed for suspended, totally exposed (outdoor) and indoor spot heating applications
• Finish: High-temp brown powder coated nish or corrosion
Heats solid objects, not the air!
Manufactured in U.S.A.
FINISH - BROWN FINISH - STAINLESS STEEL
Includes Electrical Enclosure
UPC#
686334
MODEL LIST
UPC#
686334
Product Models
MODEL LIST
resistant stainless steel 24 gauge housing
• 60° Symmetric Heat Pattern
• Gold anodized Aluminum reector and end caps
• Painted models are direct wire, unless specied and are supplied with 6” lead wires for eld connection in the
internal wiring compartment. These models are available with a factory installed 6’ cord set. The 208V model must
have a eld supplied plug.
• Stainless steel models include an electrical enclosure assembled to the end of the heater housing and (2) 6” long
lead wires for direct eld connection.
• Two 2’ ft. long mounting chains and four S-Hooks included
• The OCH-Series can be surfaced mounted using the supplied mounting brackets which allow up to a 45° horizontal tilt adjustment.
CONNECTION
TYPE
WATTS BTU’S VOLTS AMPS
Qtz. Tube
Repl.
Element
WT.
(LBS.)
480444 OCH-46-120VE
480451 OCH-46-208VE 480536 OCH-46-208V-SSE 2000 6826 208 9.6 671-5061
480468 OCH-46-240VE 480543 OCH-46-240V-SSE 2000 6826 240 8.3 671-3785
480475 OCH-46-277VE 480550 OCH-46-277V-SSE 2000 6826 277 7.2 671-5018
480499 OCH-57-208VE
480482 OCH-57-240VE 480567 OCH-57-240V-SSE 3000 10239 240 12.5 671-3786
480505 OCH-57-277VE 480581 OCH-57-277V-SSE 3000 10239 277 10.8 671-5059
480512 OCH-57-480VE 480598 OCH-57-480V-SSE 2250 7679 480 4.7 671-5058
485975 OCH-46-120VCE 340 --- --- ---
485982 OCH-57-208VCE
485999 OCH-57-240VCE --- --- --- 2000 6826 240 8.3 671-3785
480529 OCH-46-120V-SSE
315
480574 OCH-57-208V-SSE
360
--- --- --- 2000 6826 208 9.6 671-5061
400
1500 5120 120 12.5 671-3784
370
Hard Wire
3000 10239 208 14.4 671-5060
410
1500 5120 120 12.5 671-3784 11
Corded
Product Accessories
UPC #
686334
480888 OCHWG-46
480895 OCHWG-57 OCH-57 Series Models 2 59
MODEL DESCRIPTION FOR USE WITH
OCH-46 Series Models 2 56
Stainless Steel Wire Guards
WT.
(LBS.)
LIST
10
12
13
881128 VMB-41-SS Wall Mtg. Brackets (2) ALL OCH Models 12 208
445948 VHC-15 Variable Heat Controller 208/240V OCH Models Only 3 162
485357 VHC-32 Variable Heat Controller 208/240V OCH Models Only 3 422
Page 71
OCH Series Outdoor / Indoor Rated Quartz Electric Infrared Heater
OCH Sizing Chart
Mounting Height Heater Model Watts
7’
8’
9’
10’
12’
OCH-46 1500 11 9 99 15.2
OCH-46 2000 11 9 99 20.2
OCH-46 1500 12 10 120 12.5
OCH-46 2000 12 10 120 16.7
OCH-57 3000 13 10 130 23.1
OCH-57 2250 13 10 130 17.3
OCH-46 1500 13 11 143 10.5
OCH-46 2000 13 11 143 14.0
OCH-57 3000 14 11 154 19.5
OCH-57 2250 14 11 154 14.6
OCH-57 3000 15 12 180 16.7
OCH-57 2250 15 12 180 12.5
OCH-57 3000 17 14 238 12.6
OCH-57 2250 17 14 238 9.5
Heat Pattern Coverage ( at oor level)
Length Width Sq. Ft.
Total Watts /
Sq. Ft.
Product Specications
Series:
OCH-46 & OCH-57
Housing:
24 gauge Aluminized Steel with a baked on brown powder coat finish. Housing is cETLus Listed for indoor or outdoor applications. Horizontal mounting only.
71
Reflectors and End Caps:
.040 Gold anodized Aluminum reflectors and end caps for superior reflectiveness. 60 degree medium (symmetric) pattern only.
Elements:
Quartz Tubes. Frosted quartz envelope with a Nickel-Chromium coiled filament, porcelain end caps, and threaded-screw (stud) terminations. Fast heat-up and cool-down performance. Available Wattages from 1500 to 3000 Watts per element. Available voltages from 120 to 480 Volts.
Controls:
OCH Series heaters are not manufactured with any control device on the unit. All controls are accessories and should be specified as such. Please consult the technical sales department of factory for help in determining applicable controls. Please follow installation instructions that accompany each heater.
Accessories:
Adjustable mounting brackets (stainless steel only), vertical mounting brackets (stainless steel only), wire guards, thermostats, SCR controllers, and power contactor panels.
Mounting Congurations & Reector Pattern
Mounting
• Chain, surface mount or use our vertical mounting bracket as shown below. (Note:) All units must be mounted horizontally.
• In-Built surface mounting bracket allows for xture adjustment up to a 45° horizontal tilt.
• As shown, the heater may be suspended at any horizontal angle desired.
Chain Mount:
(Chain supplied)
Reector Pattern:
OCH-46
Length: 44.4’’
Width: 5.4’’
Height: 6.5’’
OCH-57
Length: 55.4’’
Width: 5.4’’
Height: 6.5’’
Optional Vertical Mounting Bracket:
Model # VMB-41-SS
Mounting Clearances & Recommended Mounting Height
Mounting Clearances Recommended Mounting Height
3” from ceiling; 12” from vertical surface
72” from face of heater to combustible surface
36” from another heater
OCH-46 7’-9’
OCH-57 8’-10’
Page 72
72
RPH Series Outdoor Rated Stainless Steel Electric Infrared Heater
• Instant, high-intensity radiant heat, with 30° symmetric heat pattern.
• Listed for indoor spot heating and for outdoor unprotected applications.
• Specialized Ruby “Red” Quartz Lamp infrared heating element for glare reduction.
• Stainless Steel housing with Coilzak Aluminum reector for good reectivity & corrosion
resistance.
• Heating element and mounting plate included.
Manufactured in U.S.A.
• Dimensions: 24” x 5-3/8” x 4-1/2.”
Mounting Clearances Recommended Mounting Height
Mounting Plate (provided) on top center allows heater to be mounted parallel or angled using a standard pipe nipple and box cover (supplied by installer)
6” from ceiling
24” from vertical surface
72” from face of heater to combustible surface
UPC#
686334
884501 RPH-208-A 1600 5,461 208 1 7.7 632-1620 5 884518 RPH-240-A 1600 5,461 240 1 6.7 632-1624 5
MODEL WAT TS BTU’S VOLTS PHASE AMPS
REPLACEMENT
QUARTZ LAMP
RPH-208 8’-12’
RPH-240 8’-12’
WT.
LIST
(LBS.)
344 880992 RPHWG 34
Optional Wireguard
UPC#
686334
MODEL LIST
MM Series “Mitey Midget” Electric Infrared Heater
• Instant, high-intensity radiant heat, with 60° symmetric heat pattern.
• MM heaters excel as people-heaters in areas requiring a linear, compact & concentrated heat source.
• Listed for indoor industrial and commercial comfort heat applications.
• Heavy duty Aluminum extrusion with a bright
Aluminum insert for maximum reectivity.
• Anodized Aluminum housing, (0.62” thick).
• Heat Element Sold Separately.
Manufactured in U.S.A.
UPC
686334
444019 MM-13A 500 1707 120 1 13" 3 234 443906 MMWG-13 24
442763 MM-18A 750 / 1000 3413 208-240 1 18" 4 244 443913 MMWG-18 36
449540 MM-24A 900 / 1600 5461 208-277 1 24" 5 254 441896 MMWG-24 46
442725 MM-33A 2500 8533 480 1 33" 6 273 443920 MMWG-33 50
442039 MM-46A 3000 / 3800 12457 480-600 1 46" 7 299 442046 MMWG-46 60
All MM-13A through MM-46A models are ETL Listed for use with Quartz Lamps Only!
MODEL
• Dimensions: 3.750” Wide x 3.380” High.
MAX
WATTS
MAX
BTU'S
VOLTS PH
24” from face of heater to combustible surface
UNIT
LENGTH
Mounting Clearances
24” from ceiling & from vertical surface
36” from another heater
WT.
(LBS.)
LIST
Optional Wireguards
UPC
686334
MODEL LIST
FFH Series Electric Utility Infrared Heater
• Both FFH Series Heaters are excellent for Farrowing & Finishing applications.
• Both units feature an 8 ft. 18/3 grounded cordset to plug into any 120V service.
• Gold anodized Aluminum reectors, with a 90° symmetrical reector pattern.
• Compact housing design, with the following housing nish:
FFH-512A: Gold Anodized Finish
FFH-512A
FFH-912B
Manufactured in U.S.A.
UPC#
686334
883894 FFH-512A 550 1877 120 1 5 671-3492 4 22 5 3 225
882781 FFH-912B 450/900 3072 120 1 8 671-3454 4 17 6 4 410
MODEL WAT TS BTU’S VOLTS PHASE AMPS
FFH-912B: Brown Enamel Finish
• Quartz Tubes Heat Element(s), Wire Guard & (2) 4’ ft. Jack Chains are included.
• FFH-912B Only: Offers (2) On/Off toggle switches to operate heating elements independently.
• Listed for indoor industrial and commercial comfort heat
REPLACEMENT
QUARTZ TUBE
WT.
(LBS.)
MOUNTING
HEIGHT
6’
7’
8’
Dimensions (in.)
Length Width Height
SIZING CHART - FFH SERIES Heater Model
FFH-512A 7 6 42 13.1 FFH-912B 6 7 42 21.4 FFH-512A 8 7 56 9.8 FFH-912B 7 8 56 16.1 FFH-512A 9 8 72 7.6 FFH-912B 8 9 72 12.5
LIST
LENGTH WIDTH
COVERAGE
Mounting Clearances
3” from ceiling
24” from vertical surface
72” from oor
(Sq. Ft.)
WATTS
/ Sq. Ft.
Page 73
Electric Infrared Heating Elements
Clear & Red Quartz Lamps
Notes: Life expectancy of all heating elements - 5,000 hours (4yr. Pro-rated Warranty). All heating elements operate at 50 / 60 Hertz.
UPC
686334
440059 630-05129 500 120 8-11/16 5 MM-13A 101 442770 630-10209 444118 630-10249 240 440165 630-16209 440172 630-16249 240 119 440998 631-16249 240 144 446235 630-38579 3800 600 440189 630-16279 277 119 481731 630-16489 480 481748 630-25209 481755 630-25249 240 481762 630-25279 277 190 440547 630-25489 480
Model Sufx: 630 = Horizontal Burning “Clear”; 631 = Vertical OR Horizontal Burning “Clear”; = Horizontal Burning “Red”
Item # Watts Volts
1000
1600
2500
Color temperature emitted: approx. 4100° F (high brightness).
Approximately 96% radiant efciency.
Length (in.)
Overall Heated
208
13-11/16 10 MM-18A
208
19-11/16 16
208
28-11/16 25
Fits
Model 686334
222, 223 or
MM-24A
342, 343 or
MM-33A
LIST
440363 631-25489 440684 631-25609 600
178 107 ---- ---- ---- ---­119 ---- ---- ---- ---- 234
440677 630-36489 3650 480
444132 631-38579 3800 600
144
169
446150 632-1620 1600 208 19-11/16 16 222/223 446167 632-1624 1600 240 19-11/16 16 or RPH
150 446228 632-2548 2500 480 28-11/16 25 342 or 343 169
3/8” Diameter clear or red quartz envelope.
Coiled tungsten lament; sealed porcelain end caps; halogen gas lled.
UPC
Item # Watts Volts
480
2500
RED QUARTZ LAMPS
Excellent resistance to thermal shock.
Quartz Tubes
Notes: Life expectancy of all heating elements - 5,000 hours. All heating elements operate at 50 / 60 Hertz.
UPC
686334
443234 671-3784 1500 120 39-11/16 34-3/16 441810 671-5061 2000 208 39-11/16 34-3/16 441803 671-3785 2000 240 39-11/16 34-3/16 441933 671-5018 2000 277 39-11/16 34-3/16 441667 671-5060 3000 208 50-11/16 45-3/16 441476 671-3786 3000 240 50-11/16 45-3/16 441940 671-5059 3000 277 50-11/16 45-3/16 441957 671-5058 2250 480 50-11/16 45-3/16 440356 671-3454 450 120 12-15/16 8-7/16 FFH-912B 78 440080 671-3492* 550 120 19-1/2 16 FFH-512A 83 446242 671-5056 1000 120 18-5/16 14-7/16 CH-2212-1C 91 446259 671-5057 1425 240 27-5/16 23-7/16 CH-6424-1C 104
*3/8” Diameter
Item # Watts Volts
Length (in.)
Overall Heated
Fits
Model
OCH-46 124
OCH-57 138
LIST
• 5/8” Diameter frosted quartz envelope
Nickel-Chromium alloy coiled
• Color temperature emitted: approx.
• Approximately 60% radiant efciency
• Fast heat-up/cool-down
• Moisture resistance: High
• Mechanical ruggedness: Good
Metal Sheath Elements
Length (in.)
Overall Heated
28-11/16 25
41-11/16 38
element with porcelain end caps and pigtailed termination
1800° F (bright orange glow)
Fits
Model
342, 343 or
MM-33A
462, 463 or
MM-46A
73
LIST
162
222
222
234
144
Notes: Life expectancy of all heating elements - 5,000 hours. All heating elements operate at 50 / 60 Hertz.
UPC# 686334 445870 641-37211 1800 120 445832 641-35661 445795 641-35611 240 CH-224-1A, CH-624-3A 445849 641-36051 277 CH-277-1A, CH-627-3A 445801 641-35621 480 CH-248-1A, CH-648-3A 445887 641-50011 600 CH-257-1A, CH-657-3A 445856 641-36061 445818 641-35631 240 CH-424-1A, CH-1324-3A, CH-2724-3B 445863 641-36071 277 CH-427-1A, CH-1327-3A 446174 641-35641 480 CH-448-1A, CH-1348-3A, CH-2748-3B 445894 641-50021 600 CH-457-1A, CH-1357-3A, CH-2757-3B
Note: Inner reector shipped with replacement Metal Sheath Elements.
MODEL WATT S VOLTS
2000
4500
UPC# 686334 445788 641-70321 1800 120 445702 641-70241 445719 641-70251 240 CH-224-1C, CH624-3C 445726 641-70261 277 CH-227-1C, CH-627-3C 445733 641-70271 480 CH-248-1C, CH-648-3C 445771 641-70281 600 CH-257-1C, CH-657-3C 445597 641-70001 445603 641-70011 240 CH-424-1C, CH-1320-3B, CH-2720-3C 445610 641-70021 277 CH-427-1C, CH-1327-3B 445627 641-70031 480 CH-448-1C, CH-1348-3B, CH-2748-3C 445665 641-70041 600 CH-457-1C, CH-1357-3B, CH-2757-3C
MODEL WATTS VOLTS
2000
4500
LENGTH (in) Replacement Heating Element
Overall Heated Fits “CH-Models” Fits “FHK Models”
208 CH-220-1A, CH-620-3A
23-1/16 18
208
44-7/16 39
Overall Heated Fits “CH-Models” Only
208 CH-220-1C, CH-620-3C
24-1/16 18
208
45-7/16 39
CH-420-1A, CH-1320-3A, CH-2720-3B
LENGTH (in) Replacement Heating Element
CH-212-1A FHK-212-1CA
FHK 2.0 & 6.0 KW
FHK 4.5 & 13.5 KW
CH-212-1C
CH-420-1C, CH-1320-3B, CH-2720-3C
Models
Models
LIST
144
189
• 0.430” Diameter
LIST
Incoloy metal sheath envelope
• Nickel-
144
Chromium alloy coiled element imbedded in Magnesium Oxide insulating
189
powder
• Color temperature emitted: approx. 1600° F (dull orange glow)
• Approximately 50% radiant
efciency
• Slowest heat-up/ cool-down
• Moisture resistance: Lowest
• Mechanical ruggedness: Highest
Page 74

Electric Infrared Heating Controls

74
Variable Controllers
30-Amp or 80-Amp Enclosed
VHC-32
Manufactured in U.S.A.
• Solid State phase angle variable “Triac” knob controller adjusts heat settings from 10-100% with heat loads up to 15.4-Amps.
• 208/240 VAC single-phase, single stage controller, 3200 Watt max.
• Positive “Off” & built-in On/Off Rocker switch lights “red” during operation.
• NEMA 1 Aluminum enclosure with stainless steel face plate designed for wall mounting or suitable for semi-recessed applications.
• Must be mounted in a protected area.
• Can either operate Quartz Lamps or Quartz Tube Infrared Heaters.
UPC
686334
Model Description
485357 VHC-32 Variable Heat Controller 208/240-Volt; 15.4 Amp 3 5 5 3 lbs. 422 445948 VHC-15 Variable Heat Controller; 208/240-Volt; 15 Amp 3 5 5 3 lbs. 162 445634 18D-2-30CF (Open) SCR Controller - 26 Amp MAX; No Enclosure 6 6 9 11 lbs. 942 445641 18D-2-30CF (Enclosed) SCR Controller - 26 Amp MAX; Enclosure Included 8 10 12 15 lbs. 1398 445658 18D-2-80CF (Enclosed) SCR Controller - 80 Amp MAX; Enclosure Included 8 12 14 29 lbs. 2278
Manufactured in U.S.A.
• Solid state variable device controls heat loads up to 15-Amps.
• 208/240Volt “In-Line” Controller.
• Built in On/Off knob switch with positive “off” & surface plate included.
• Designed for a 2” x 4” electrical wall box mounting (not supplied).
• Must be mounted in a protected area.
• Can only operate Fostoria Quartz Tube Infrared Heaters.
VHC-15
18D-2-80CF ENC.
Manufactured in U.S.A.
• SCR Voltage Controller - 80 Amp MAX.
• Includes (1) 24-volt Potentiometer (3” square) to control the heat output.
• Only operates Quartz Lamps at 240 or 208-Volts, single phase only.
• Potentiometer can be mounted outside, but the SCR must be located in a protected area.
• Factory wired with millisecond fuses included.
Dimension (In.)
Depth Width Height
Wt. LIST
Snow & Ice Detectors
• Main control unit for Automatic Snow & Ice Control Systems.
• By sensing both temperature and moisture the system activates and melts any snow & ice accumulations until conditions subside.
• NEMA 3R Enclosure is UL Listed and houses timers and switching electronics to operate the system.
CIT-1
• Capability to monitor up to 6 sensors (CIT-1).
• Unit can be manually activated and can be controlled and monitored from an
APS-3C
Manufactured in U.S.A.
• Positioned above ground to maximize the sensors capability.
• Detects falling or blowing of precipitation such as snow when the
optional remote switch (Model RCU-).
temperature is below 38° F.
• Most common sensor device.
UPC#
686334
319614 APS-3C Snow / Ice Control Switch 6.56 11.5 9.25 8 lbs. 2533
319761 CIT-1 General Purpose Snow Sensor 3.25 3.25 4.13 1 lb. 9 11
Model Description
Depth Width Height
Dimension (In.)
Wt. LIST
Note: Any snow & ice control system should be used with the correct sized control panel (with contactors & fusing) as supplied by factory or your electrical contractor. Also, the APS-3C requires a control device (RCU-1, CIT-1, SIT-6E) in order to operate properly.
Contactor Enclosures
• Economical load handling / switch device, ideal for use with other control equipment.
• NEMA 1 Enclosures.
• Load rating up to 600V Max., 3-Pole.
• Magnetic contactor.
Cabinet Size (In.)
Depth Width Height
5 6 10 5
Wt.
(LBS.)
LIST
194
260
FEC-30-120
Manufactured in U.S.A.
UPC
686334
440851 FEC-30-120 440868 FEC-30-240 208/240 440875 FEC-60-120 440882 FEC-60-240 208/240
Model
Contactor
Amps
30
60
Coil
Voltage
120
120
Note: Installer to provide overload protection for all infrared heaters.
Page 75
Electric Infrared Heating Controls
Pre-Wired Contactor Panels
• Factory pre-wired for quick installation, with the following optional equipment: Snow & Ice Detector (APS-3C) Single & Two-Stage Thermostats Two-stage thermostats require a minimum 2-contactors.
Note: Contact factory for 3R, 4, 4X, & NEMA 12 “special” built models.
IMPORTANT FUSING INFORMATION
Fuses are NOT included since panels can be used with various infrared heat sources. Quartz
FPC2120
Manufactured in U.S.A.
120-V CONTROL SYSTEM 24-V CONTROL SYSTEM
UPC#
686334
MODEL
UPC#
686334
Lamp Heat Sources: Use FRS-600V (or equal) “Time Delay” fuses; Class RK-5. Quartz Tube & metal Sheath Heat Sources: Use KTS-R 600V (or equal) “Fast Acting” fuses; Class RK-1. Fuse circuits as close to calculated load as possible. Circuits less than 35 Amps will require the use of fuse reducers.
MODEL DEPTH WIDTH HEIGHT
Standard Models
MAX
AMPS
VOLTS
• Step-down transformer and secondary fusing for 24V or 120V control circuit.
• 3-Phase load rated.
• Fuses are NOT included.
• NEMA 1 Enclosures.
• Max 50-Amp branch circuit fusing.
CABINET SIZE (IN.)
WT.
(LBS.)
LIST
75
4459902 FPC8110 4864302 FPC8210
4460002 FPC2110 4864402 FPC2210 240
50
4460102 FPC7110 4864502 FPC7210 277/480 1891
4460202 FPC4110 4864602 FPC4210 480 1752
4460302 FPC8120 4864702 FPC8220
4460402 FPC2120 4864802 FPC2220 240
100
4460502 FPC7120 4864902 FPC7220 277/480 2336
4460602 FPC4120 4865002 FPC4220 480 2142
4460702 FPC8140 4865102 FPC8240
4460802 FPC2140 4865202 FPC2240 240
200
4460902 FPC7140 4865302 FPC7240 277/480 3337
4461002 FPC4140 4865402 FPC4240 480 3143
208
1752
6.75 16 24 52
208
2142
6.75 16 24 70
208
3143
6.75 24 30 88
4461102 FPC8160 4865502 FPC8260
4461202 FPC2160 4865602 FPC2260 240
300
4461302 FPC7160 4865702 FPC7260 277/480 4061
4461402 FPC4160 4865802 FPC4260 480 3865
208
3865
6.75 30 36 106
Page 76
76
FHK Series Portable Metal Sheath Electric Infrared Heater
• Double side wall housings to reduce operating temperatures.
• 6.0 and 13.5KW heaters have double top bafes to reduce
operating temperatures.
• 60° symmetrical heat pattern.
• Factory installed U-shaped metal sheath infrared heating elements have an average 5000 hour life.
• Heavy duty protective wire screens.
• GOLD anodized Aluminum internal reector.
• Ground fault protection must be used.
Square Feet Heated
2.0KW & 4.5KW Stand Models
Manufactured in U.S.A.
6.0KW & 13.5KW Hand Cart Models
NON-PROTECTED
KW
1.8 / 2.0 25 36 40 50 2 feet
4.5 64 75 90 125 3 feet
6 85 100 120 150 4 feet
13.5 192 225 270 375 7 feet
AREA
BELOW ABOVE BELOW ABOVE
35 oF 35 oF 35 oF 35 oF
SEMI-PROTECTED
AREA
Required
Clearance
From Front
of Heater
Standard FHK Models
UPC#
686334
881739 FHK-224-1A
881753 FHK-248-1A 480 1 4.2 880435 SO 16/3
881784 FHK-424-1A
881807 FHK-448-1A 480 1 9.4 880466 SO 14/3 103
882910 FHK-624-3A
882934 FHK-648-3A 480
MODEL KW BTU's VOLTS PH AMPS W T. LIST
2.0 6,826
4.5 15,359
6.0 20,478
240 1 8.3
17 lbs. 502
240 1 18.8
24 lbs. 561
3 14.4
240
1 25.0 880442 SO 10/3 142
37 lbs. 966
3 7.5 880497 SO 14/4 130
1 13 880466 SO 14/3 103
OPTIONAL 25' POWER CORD
UPC#
686334
880435 SO 16/3
880459 SO 12/3 130
880497 SO 14/4 130
MODEL LIST
92
882965 FHK-1324-3A
13.5 46,076
882989 FHK-1348-3A 480
Contact Factory for Special Build Models @ 208V, 277V or 600V.
240 3 33.0
3 17.0 316422 SO 12/4 141
1 29.0 880527 SO 8/3 239
880510 SO 8/4 269
65 lbs. 1601
Factory Pre-Wired FHK Models With 15 Ft. Cord & Grounded Plug
UPC#
686334
881715 FHK-212-1CA STAND 1.8 6,143 120 1 15.0 18 lbs. 482
MODEL TYPE KW BTU's VOLTS PHASE AMPS W T. LIST
FHK Infrared Control Options
UPC
MODEL # DESCRIPTION
686334
485814 TO-SK-1 Tip-Over Switch 208V - 600V 10.3 10.3 5.0 12 397
589376 DC-SK-1 Disconnect Switch 120V - 600V 5.0 6.0 4.0 5 360
486026 GF-SK-1 Ground Fault Sensing Switch 208V - 600V 10.3 10.3 5.0 12 737
Note: All SK-1 Models have NEMA-1 Enclosure, 50-Amp Max. & 1/3-Phase Rated.
Operating
Voltage (VAC)
Dimensions (In)
Ht. Wd. Dp.
WT.
(lbs.)
Model “TO” & “GF” features
LIST
include a positive “off” & a built-in on/off rocker switch that glows red during operation. Additionally, enclosure can mount directly to the terminal box on the back of the heater (FHK-6/13 only) or be mounted to a remote wall surface.
TO-SK-1
or GF-SK-1
Page 77
Chain mounted
CH 2212-1C
Portable Cart Unit CH 6424-1C
with FHK-1 Cart
CH Series Portable Quarts Infrared Heater
MODEL CH 2212-1C has two 1000 Watt elements that can be switched on / off by toggle switches to produce 1000 Watts or 2000 Watts of heat. - 15’ cord and NEMA 5-20 molded plug.
MODEL CH 6424-1C has two sets of 1425 Watt elements that can be switched on / off by toggle switches to produce 2850 Watts or 5700 Watts of heat. - 15’ cord and NEMA L6-30 twist lock plug.
• 60° symmetrical heat pattern. • Quartz tubes and built in wire guards included.
• Interior or protected outdoor use only. • GOLD anodized Aluminum reector and end caps.
UPC 686334 MODEL KW BTU's VOLTS PHASE AMPS WT. LIST
884099 CH-2212-1C 2.0 / 1.0 6826 / 3413 120 1 16.7 / 8.35 16 lbs. 547 884105 CH-6424-1C 5.7 / 2.85 19454 / 9727 240 1 23.8 / 11.9 31 lbs. 901 852401 FHK-1 OPTIONAL CART 20 lbs. 129
20 AMP Plug NEMA #5-20
Note: CH-2212-1C operates with a 20- Amp molded plug.
30 AMP Plug NEMA #6-30P
Note: CH-6424-1C operates with a 30- Amp twist lock plug.
Manufactured in U.S.A.
Listed
for
overhead
operation
77
PCH Series Portable Quartz Infrared Spot Heater
Features
• Suitable for portable spot heat or for curing
Width: 53” Height: 2-6’ Depth: 28”
• Average element life is 5000 hours
• Bright Aluminum reector and end caps
• 20 gauge powder coated Steel housing
• 15’ long, 3 wire (14/3) cordset with standard 3 pring NEMA 5-20P
UPC#
686334
884112 PCH-48C 1500 5120 120 1 30 504
MODEL WAT TS BTU’s VOLTS PHASE WT. LIST
clear coat paint
• Height adjustable from 2’ to 4’
• On-Off rocker switch standard
• 4 casters included; Tip-Over power cutoff safety switch
• 60o symmetrical heat pattern
• 5/8” diameter quartz tube included
Portable Infrared Instant On-Off Heat Gun
Features
• Provides instant spot heat in a controlled pattern
• Spot cure retouched paint and other
nishes
• De-wrinkle or relax materials such as cloth-vinyl-leather
• T-3 Tungsten IR lamp
• Spring loaded power button switch
• 10’ long, 18/3 grd. cordset with NEMA plug
UPC#
686334
592284 RHG-1012A
592277 RHG-1012B 1500
MODEL WATTS VOLTS AMPS WT. LIST
1000 120 8.4 3
Portable Electric Infrared Heat Panels
Features
• Portable panels are built to withstand rigors of industrial and heavy-commercial applications, such as auto collision repair shops.
• 20 gauge Steel frame, base, and housing construction.
• 3” Steel casters for high stability and ease of mobility
• Gold anodized Aluminum reectors and end caps allow 10% faster cure time than polished Aluminum reectors, especially in paint and dust-laden atmospheres.
• Elements achieve full temperature in less than 2 minutes
• Fused disconnect switches are installed on the back of each unit.
• Units are positioned with adjustable hinges allowing the user to use direct heat more precisely to the target area.
• Gentle but effective medium-wave radiant heat can quickly boost, ash-off, or cure a variety of nishes, and lessens the chance of blistering and/or overheating the coating.
• Medium-wave infrared heating elements are also effective for ash-off of water-based clear
coatings being mandated by environmental agencies in many states.
General Curing Guidelines
Material Type
Curing Time 3-5 mins 3-6 mins 8-20 mins 3-10 mins 12-30 mins 10-30 mins
Note: Curing times will vary depending on material and shop conditions. This chart is based on distances of 18-24” away from the target area.
Solvent Based
Primer
Water Based
Primer
Two Component
Primer
Water Based
Clear Coat
Standard Models
HP-5-QT
Acrylic enamel &
Polyurethane Clear Coat
HP-11-QT
Urethane Clear Coat &
High Solids Top Coat
2063
UPC#
686334
884129 HP-5-QT 4,800 884136 HP-6-QT 6,400 26.7 4 884143 HP-11-QT 11,200 46.7 7 6-3 SO 89-1/2 77 225 5800
Model WATTS VOLTS AMPS
20 4
240
HEAT
SOURCES
CABLE
TYPE (20’)
12-3 SO
Dimension (In.) Heated Area (In.) Width Height Width Height
44-5/8
66-5/8 61
56-1/2
40
44
Wt. LIST
116 2725
141 3150
Page 78
FES & YES Series Heat WaveTM Portable Electric & Wall or Ceiling Mounted Salamander
FES Series Product Features & Information
78
BUILDING SIZE: 1000 SQ. FEET 1500 SQ. FEET 2000 SQ. FEET
HEATER: 20 oF 40 oF 20 oF 40 oF 20 oF 40 oF
• Safety yellow heater enclosure with safety screens on both air intake and output openings.
• Optional 25’ long SO type cord, ready for plug attachment is available for each model.
• Long-life nned tubular heating elements.
• Thermostat adjustment 40° to 100° F.
• Magnetic contactor.
• Automatic reset.
• High-limit thermal cutout switch.
Manufactured in U.S.A.
• Fan only switch.
• 10” wheels.
• 800 CFM-15KW units - 1100 CFM-30KW units.
Standard FES Models
UPC#
686334
886017 FES-1520-3A 15 51195 208 3 42 45oF 65 lbs. 886079 FES-1524-1A 15 51195 240 1 63 45oF 69 lbs. 886024 FES-1524-3E 15 51195 240 3 36 45oF 65 lbs. 886031 FES-1548-3E 15 51195 480 3 18 45oF 65 lbs. 886048 FES-1560-3A 15 51195 600 3 15 45oF 65 lbs. 886055 FES-3048-3A 30 102390 480 3 36 90oF 83 lbs. 2537 886062 FES-3060-3A 30 102390 600 3 29 45oF 65 lbs. 2665
10 KW, 240V, 1Phase factory pre-wired model with 10 ft. cable & straight blade range plug.
MODEL KW BTU's VOLTS PH AMPS TEMP RISE W T. LIST
UPC
686334
MODEL KW BTU's VOLTS PHASE AMPS TEMP RISE WT. LIST
AVERAGE MINUTES TO ACHIEVE TEMPERATURE RISE*
TEMP RISE TEMP RISE TEMP RISE
10 KW 70 min 140 min 105 min 210 min --- --- 15 KW 47 min 94 min 71 min 142 min 94 min 188 min 30 KW
45 KW
* Based on a 15' ceiling height - lower ceiling height will reduce time required
23 min 46 min 35 min 70 min 47 min 94 min 10 min 30 min 20 min 35 min 35 min 40 min
THE ELECTRIC
ALTERNATIVE TO
PROPANE AND
KEROSENE SPACE
HEATERS
OPTIONAL 25' POWER CORD*
UPC 686334 MODEL LIST
316408 SO 6/4 295
1609
880530 SO 4/3 256 316408 SO 6/4 295 316422 SO 12/4 149 316408 SO 6/4 295 316422 SO 12/4 149
*Plug not included.
874434 FES-0924-1C 9 30717 240 1 38 25oF 55 lbs. 1532
886000 FES-1024-1CA 10 34130 240 1 42 30oF 60 lbs. 1532
45 Kilowatt FES Model
OPTIONAL 25’ POWER CORD
UPC 686334 MODEL LIST
316439 SO 4/4 300
316408 SO 6/4 295
UPC
686334
872225 FES-4548-3 45 153585 480 3 54.2 70°F 125 lbs. 4196
487405 FES-4560-3 45 153585 600 3 44 70oF 125 lbs. 4410
MODEL KW BTU’s VOLTS PH AMPS
• Safety yellow heater enclosure with safety screens on both air intake and output openings.
• Optional 25’ long SO type cord, ready for plug attachment is available for each model.
• Long-life nned tubular heating elements.
• Thermostat adjustment 40° to 100° F.
• Two 10” rear wheels and a front locking caster.
TEMP
RISE
WT. LIST
• High-limit thermal cutout switch with manual reset.
• 2200 CFM
• Fan only operation feature
Standard YES Models
• Wall / ceiling mount included with unit
• Unit is ready for direct wiring
UPC
686334
886086 YES-1520-3A 15 51195 208 3 42 45oF 60 lbs.
886185 YES-1524-1A 15 51195 240 1 63 45oF 60 lbs.
886093 YES-1524-3E 15 51195 240 3 36 45oF 60 lbs.
886109 YES-1548-3E 15 51195 480 3 18 45oF 60 lbs.
886123 YES-3048-3A 30 102390 480 3 36 90oF 72 lbs. 2416
MODEL KW BTU's VOLTS PHASE AMPS TEMP RISE W T. LIST
• Thermostat adjustment 40° to 100° F.
Manufactured in U.S.A.
1532
Wall Mounted
Ceiling Mounted
Page 79
198 Series 120 Volt Radiant and/or Fan Forced Portable Heater
• 3-Heat settings:
- 600 Watt radiant
- 900 Watt fan forced
- 1500 Watt radiant & fan forced
• Temperature control thermostat
• Dual safety system:
- Tip over switch
- Manual reset type limit control
• 6’ long - 3 conductor cord
• 1 year limited warranty
Width: 11”
Height: 15”
Depth: 12”
Standard Models
UPC
686334
445092 198 TMC 1500 / 900 / 600 5120 120 12.5 / 7.5 / 5 1 9 lbs. 148
MODEL WATTS
MAX
VOLTS AMPS PHASE W T. LIST
BTU's
178 Series 120 Volt Ceramic Fan Forced Portable Heater
• Two heat settings: 1500W / 950W plus fan only setting (20W)
• Temperature control thermostat
• 6’ long - 3 conductor cord
UPC
686334
445931 178 TMC 1500 / 950 5120 120 12.5 / 7.1 1 8 lbs. 132
Note: Photograph is a representation of stocked models. Actual model may vary in appearance.
MODEL WATTS MAX BTU's VOLTS AMPS PHASE W T. LIST
• Double safety system:
- Automatic reset type limit control
- Thermal cut-off device
Standard Models
Width: 11-1/4”
Height: 10”
Depth: 7”
188 Series 120 Volt “Milk-house” Style Fan Forced Portable Heater
79
• 1300W & 1500W heat settings plus fan only setting
• Temperature control thermostat
• 6’ long - 3 conductor cord
• Triple safety system:
- Tip over switch
- Automatic reset type limit control
- Thermal cut-off device
Standard Models
UPC
686334
800419 188 TASA 1500 / 1300 5120 120 12.5 / 10.8 1 9 lbs. 88
MODEL WATTS
MAX
BTU's
VOLTS AMPS PHASE W T. LIST
“Under-The-Desk” Conned Space Radiant Heat Panel
• Use under desks for personal comfort or in small areas for freeze protection or moisture removal.
• Built in stand.
• Temperature control thermostat.
Standard Models
Manufactured in U.S.A.
UPC#
686334
450881 170-TS 170 580 120 1 9 lbs. 157
MODEL WATTS BTU’s VOLTS PHASE WT. LIST
483 Series 120 Volt Portable Baseboard Convection Heater
Width: 10” Height: 16”
Depth: 9-1/2”
• 6' long - 3 conductor cord
Width: 22-3/4”
Height: 8”
Depth: 1-3/4”
• 1500 Watt convection heater
• Temperature control thermostat
• Manual reset type limit control
• Power on indicator light
Width: 48”
Height: 5-1/4”
Depth: 7-1/2”
• 6’ long - 3 conductor cord
Standard Models
UPC
686334
870887 483 TM 1500 5120 120 12.5 1 13 lbs. 156
MODEL WATTS
MAX
BTU’s
VOLTS AMPS PHASE WT. LIST
Manufactured in U.S.A.
Page 80
30 AMP Plug NEMA #6-30P
30 AMP Plug NEMA #6-30P
30 AMP Plug NEMA #6-30P
474 Series 240 Volt Dual Heat Fan Forced Portable Heater
80
• 2000W & 4000W heat settings
• Temperature control thermostat
• Manual reset type limit control
• 6’ long - 3 conductor cord
UPC#
686334
446181 H474 TMC 2000 / 4000 13652 240 8.3 / 16.6 1 20 lbs. 229
MODEL WATTS
MAX
VOLTS AMPS PHASE WT. LIST
BTU's
Width: 16”
Height: 16”
Depth: 8-1/2”
20 AMP Plug NEMA #6-20P
5800 Series Garage/Workshop 240/208 Volt Fan Forced Portable Heater
• Up to 4800 Watts of heating comfort for garage or utility room applications
• 4000 Watts available for smaller areas.
• Built in bi-metal double pole
thermostat - 50° to 90° range.
• Steel tubular heating element
• Wall/Ceiling bracket included
• Manual reset standard
• Power on and overheat pilot lights
UPC#
686334
503402 HF5840TC 4000/3000 13652
503396 HF5848TC 4800/3600 15086 20 / 17.3 30 Amp 300
MODEL WATTS
MAX
BTU's
VOLTS AMPS PHASE
240 / 208
ITEM WIDTH HEIGHT DEPTH
Heater 10.625 11” 9.625”
Bracket 2.5” 10” 14.0”
16.6 / 14.4
PLUG TYPE
20 Amp
1
WT.
(LBS)
17
LIST
225
ICH Series 240/208 Volt Construction Site/Utility Fan Forced Portable Heater
• Operates on 240V or 208V
• Steel tubular heating element
• 43°F air heat rise
• Internal overheat thermostat
• Temperature control thermostat
• 6’ long cordset
UPC#
686334
450874 ICH-240C 4000 / 3000 13648 240 / 208 16.7 / 14.4 1 15 lbs. 247
MODEL WATTS
MAX
BTU's
Width: 10 5/8”
Height: 12 3/4”
Depth: 10”
20 AMP Plug NEMA #6-20P
VOLTS AMPS PHASE W T. LIST
680 Series “Bulldog” 240/208 Volt Fan Forced Portable Unit Heater
Swivel base allows unit to be wall, oor, or
ceiling mounted.
• Operates on 240V or 208V
• Finned steel tubular heating element
20 AMP Plug NEMA #6-20P
HF684TC HF685TC,
• Internal manual reset thermal cut-out
• 6’ long cord with molded plug
• Temperature control thermostat with 35°F to 85°F range
Height: 17 1/2”
• 10’ air throw - 262 CFM
UPC#
686334
446280
446297 HF685TC 4800/3600 16384/12288 240/208 1 20.0/17.4 58oF 20 lbs. 395
446303 HF686TC 5600/4200 19107/14330 240/208 1 23.4/20.2 75 oF 20 lbs. 443
683500 A1560
* HF684TC UL listed only
MODEL WATTS
*HF684TC
4000/3000 13652/10239 240/208 1 16.7/14.5 48 oF 20 lbs 377
OPTIONAL WALL CEILING BRACKET FOR HF680 & ICH 240c
MAX
BTU's
VOLTS PHASE AMPS
SERIES HEATERS
TEMP
30 AMP Plug NEMA #6-30P
HF686TC
Width: 13 1/2”
Depth: 11 1/2”
RISE
WT. LIST
73
Page 81
Manufactured in U.S.A.
Specialty Heaters
RPH Series Pump House Convection Specialty Heater
81
• Provides protection against freezing for pump houses, utility rooms, relay stations, construction sheds, etc.
Aluminum nned heating element
• Powder coated epoxy steel case
• Automatic temperature control thermostat with a 35oF to 65oF range.
• Dimension 20” x 5-1/2” x 4”
Standard Models
UPC#
686334
999083 RPH1-5A 500 1706 120 4.2 5 lbs.
999090 RPH2-5A 500 1706 240 2.1 5 lbs.
984263 RPH22-5Ai 984270 RPH2-5Ai 240 2.1
MODEL WAT TS BTU’s VOLTS AMPS W T. LIST
International Models
500 1706
220 2.3
5 200
FH Series In-Floor Fan Forced Specialty Heater
• Powder coated 20 gauge steel case
• 14 gauge grill
Steel spiral nned heating element
• Auto reset thermal cut out with audible alarm.
• Floor opening: 14-1/8” x 7-1/4” x 7-3/8”
Manufactured in U.S.A.
• Grill dimensions: 15-13/16” x 8-13/16”
Standard Models
UPC#
686334
378239 FH15
378277 FH1T Single Pole Integral Thermostat Kit 1lb 148
MODEL WAT TS BTU’s VOLTS AMPS WT. LIST
750 2560 120 6.25
1500 5120 120 12.5
1500/1125 5120 / 3840 240/208 6.25/5.41
OPTIONAL FIELD INSTALLED THERMOSTATS
15 lbs 572
200
TSH Series Fan Forced Kickspace Specialty Heater
Fits into softs, stair risers or under utility cabinets
• Finned steel heating element.
• Manual reset thermal cut-out
• Recessed opening: 22-3/8” x 3-5/8” x 11-1/2”
Manufactured in U.S.A.
• Grill dimensions: 23-7/8 x 3-5/16
Standard Models
UPC#
686334
381802 TSH20J
970174 TSH20JW Above Model with White Grill
378376 TSH1TX Single Pole Integral Thermostat Kit 1lb
378383 TSH2TX Double Pole Integral Thermostat Kit 1lb
MODEL WATTS BTU’s VOLTS AMPS W T. LIST
1500 / 1000 5120 / 3412 120 12.5 / 8.4
1500 / 750 5120 / 2560 208 7.2 / 3.6
2000 / 1000 6284 / 3412 240 8.4 / 4.2
OPTIONAL FIELD INSTALLED THERMOSTATS
16 lbs 342
78
Page 82
82

CF & CFH Series Variable Speed Air Curtains

Product Specications
CABINET: Shall be constructed of 20 gauge rigid steel with baked on epoxy powder coat paint for du­rability. DISCHARGE VANES: Shall extend the entire width of the unit and be adjustable for optimum perfor-
mance of air ow.
BLOWERS: Shall be forward curved centrifugal type, DWDI with corrosion resistance scroll and wheel.
MOTORS: Shall be heavy duty, PSC, direct drive high efciency and designed for use with
SCR controllers. Motors shall be permanently lubricated for long life and have thermal over load protection. Motor shall have double insulation pro­tection for quieter operation. Quick disconnects shall be supplied to accommodate easy installation and service of motor. SCR SPEED CONTROL­LER: Supplied on all units compatible with the motor with low end adjustment for air volume control and sav­ings in power consumption. ELECTRIC HEAT (OPTION­AL): Electric heater available as eld installed option. Elec­tric heater shall be steel sheath element with helical wound
steel ns for maximum heat
transfer and safety.
Air Curtain with Heater
Module
NOTE: All heating sections are constructed of totally enclosed n tubular ele­ments for safety and longer operating life. With heat­ing section installed, unit becomes a 24 Volt control unit and can utilize a low voltage thermostat for con­trol of heating.
NOTE: For 72” through 120” units, order multiple heater modules corre­sponding to the actual air curtain models
686334
671200 36 CF36 3288/455 2672/333 671217 48 CF48 4168/786 4515/766 1606/583 4.4/3.6 519/189 82 1709 671224 60 CF60 4168/764 6544/931 1636/562 4.4/3.8 509/199 90 1843
671231 36 CFHD36 3288/1120 2672/819 671248 48 CFHD48 4256/929 4611/906 1662/500 5.9/4.8 586/168 85 1792 671255 60 CFHD60 4256/924 5763/1126 1652/509 5.2/4.4 708/172 93 1930
Model # Unit Width KW Volts Phase
CFHTR 36 10.0 208 3
MODEL
SIZE
UPC
(in)
72 2 EA: CF36 3288/455 5344/666 1659/620 7.8/6.8 944/308 148 3062 96 2 EA: CF48 4168/786 9030/1532 1606/583 8.8/7.2 1038/378 164 3318
108 3 EA: CF36 3288/455 8016/999 1659/620 11.7/10.2 1416/462 222 4594
120
72 2 EA: CFHD36 3288/1120 5344/1638 1689/603 8.8/8.6 1206/384 154 3222 96 2 EA: CFHD48 4256/929 9222/1812 1662/500 11.8/9.6 1172/336 170 3480
108 3 EA: CFHD36 3288/1120 8016/2457 1689/603 13.2/12.9 1809/576 231 4833
120
MODEL
STANDARD UNITS: 1/2 HP MODELS - UP TO 10’ HIGH DOORWAYS - WITHOUT HEAT SECTION
1 EA: CF48 4168/786
2 EA:CF36 2672/333 1659/620
HEAVY DUTY UNITS: 3/4 HP MODELS - UP TO 12’ HIGH DOORWAYS - WITHOUT HEAT SECTION
1 EA: CFHD48 4256/929 2 EA: CFHD36 3288/1120 1689/603
EXAMPLE
| | | | |
HEATER
WIDTH
CFHTR
KW VOLTS
208 240 7.2 9.0 15 14 480 3.6 4.5 15 14
3
277 208 14.4 18.0 20 12 240 12.5 15.6 20 12 208 240 12.0 15.0 20 12 480 6.0 7.5 15 14
5
277 208 24.0 30.0 35 8 240 20.8 26.6 30 10 208 240 18.0 22.5 25 10 480 9.0 11.3 15 14
7.5 277
208 36.0 45.0 50 6 240 31.2 39.0 45 8 208 240 24.0 30.1 35 8
10
480 12.0 15.0 20 12
36, 48, or 60 Inch Width
NOTE: 12KW MAXIMUM ON 36” WIDTH UNITS
277 240 41.6 52.0 60 6 208 240 28.8 36.0 40 8
12
480 14.4 18.0 20 12 277 1 43.3 54.1 60 6 208 240 36.0 36.0 55 6
15
480 18.0 18.0 30 10
FT. / MIN.
HI - LOW
PHASE
3
1
3
1
3
1
3
1
3
3
NOZZLE
CFM
9859/1432
9955/2544
VOLTS
120
120
Use the example shown (left) to order unit with heat section
HEATER
AMPS
8.3 10.4 15
10.8 13.5 15 14
13.8 17.25 20
18.0 22.5 25 10
20.8 26.0 30
27.0 33.8 40 8
27.7 34.4 40
36.1 45.1 50 6
33.3 41.6 45
41.6 52.0 60
MINIMUM CIRCUIT
RPM
HI - LOW
1659/620 3.9/3.4 472/154 74 1576
1606/583
1689/603 4.4/4.3 603/192 77 1659
1662/500
by specication
AMPS
AMPS
HI - LOW
12.2/10.4 1982/497 230 4721
14.7/13.4 2981/552 239 4961
MAXIMUM
FUSE AMPS
WATTS
HI - LOW
BTUH
10,239
17,075
25,597
34,130
40,956
51,195
75°C WIRE
AWG
14
12
10
8
8
6
Manufactured in U.S.A.
WT.
(lbs)
LIST
LIST
36” - 1205
48” - 1331
60” - 1377
SD Series - Setback on Demand Thermostat
FULLY AUTOMATIC: All the savings without any of the hassles of a programmable ther­mostat. Once installed, everything is automatic. When people are present it automatically controls to the comfort setting. When they leave, it automatically returns to the economy setting.
SMART COMFORT: The SD thermostat learns your schedule so you arrive to a comfortable temperature. Holidays are no problem. When no-one arrives, it automatically returns to the economy setting.
AUTO-CHANGEOVER: Our Auto-Changeover doesn’t limit your comfort settings. We incorporate an adjustable deadband to protect your equipment while maintaining comfort. Factory set at 1 degree, but adjustable from 1-5 degrees.
ONE MODEL WORKS WITH ALMOST ANY LOW VOLTAGE SYSTEM.: The SD ther­mostat works with low voltage systems up to 4 stages of heat, 4 stages of cool, or any com­bination up to a total of 4 stages including Heat Pumps.
Patent Pending
UPC#
686334
523646 SDHW1001 White Hardwire 375
MODEL COLOR TYPE LIST
Page 83
Features
• Single pole and double pole
• Heat only, cool only, & heat or cool
• DP models include positive off
• Celsius and Fahrenheit temperature scale
• Optional Thermometer
• 22 Amps, 277 Volts AC
EPET Series and HLT Series Hazardous Location

Thermostats & Controls

ET Series - Line Voltage
UPC #
686334 538725 AET5DWS Double Pole 22 Amp, 120-277V with leads, Anticipator 538732 AET5SWS Single Pole 22 Amp, 120-277V with leads, Anticipator 538886 ET5DS Double Pole 22 Amp, 120-277V, Heat Only 538749 ET5D4S Double Pole 22 Amp, 120-277V, 35-75oF Temp Range 538756 ET5DTS Double Pole 22 Amp, 120-277V, with Thermometer, Heat Only 538763 ET5DWS Double Pole 22 Amp, 120-277V, Heat Only with Leads 538770 ET5MS Heat Only, 2 Stage 538787 ET5SS Single Pole 22 Amp, 120-277V, Heat Only 538794 ET5S4S Single Pole 22 Amp, 120-277V, 35-75oF Temp Range 538800 ET5SRS Single Pole 22 Amp, Cooling Only 538893 ET5SRTS Single Pole Cool with Thermometer 538817 ET5STS Single Pole 22 Amp, Heat Only with Thermometer 538824 ET5SWS Single Pole 22 Amp, Heat Only with Leads 538831 ETD5MS Double Throw, 2 Stage Heat, 1 Stage Cool 538848 ETD5MTS 2 Heat, 1 Cool with Thermometer 538855 ETD5SS Single Pole Double Throw Heat/Cool 538862 ETD5STS Single Pole Double Throw Heat/Cool with Thermometer
Motor Rating (full load): 3/4 HP @ 125V, 1-1/2 HP @250V Pilot Duty Rating 125VA @ 24VAC NEMA Class Seven Div. 1 Approved Class I Group C & D, Class II Group E, F, & G Not rated for Group B
MODEL DESCRIPTION LIST
83
41.65
37.40
32.90
33.60
34.30
33.60
35.70
27.50
30.80
27.30
30.80
30.80
32.20
35.70
37.10
30.80
32.20
Features
• SPDT & DPDT Models
• Heat or cool compatible
• Celsius and Fahrenheit temperature scale
• Bi-Metal or capillary sensor
• Snap action switch
• Casting tapered top and bottom for 3/4” conduit
• 1/2” thick cast Aluminum housing
• Dimension 5-3/4” x 6-3/8” x 5.57”
UPC#
686334
538077 EPETD8D DPDT - Bi-Metal 22A @120-277VAC 50-90oF 453
538107 EPETD8S SPDT - Bi-Metal 22A @120-277VAC 50-90oF 429
528078 EPETP8D DPDT - Bi-Metal 22A @120-480VAC 50-90oF 467
528061 EPETP8S SPDT - Bi-Metal 22A @120-480VAC 50-90oF 442
523158 H LT-1 SPDT - Capillary 22A @120-277VAC 40-110oF 476
523165 H LT-2 DPDT - Capillary 22A @120-277VAC 40-110oF 502
HLT Series incorporates screwdriver temperature adjustment slot and all metal housing. External
MODEL DESCRIPTION LOAD RATINGS RANGE LIST
Master ctn: 4 pcs, 24 lbs (varies slightly by model), 16” x 14.5” x 6”
EPET Series incorporate plastic knob & Bi-Metal Sensor housing.
bulb and capillary sensor.
2000 Series - Line Voltage
UPC#
686334
502849 S2022H10AA White
502436 S2022H10AB Ivory
MODEL COLOR DESCRIPTION LIST
Single Pole with leads, 22 Amp 34
Features
• White or Ivory
• Single pole and double pole
• Heat Only
• DP models include positive off
• 22 Amps, 277 Volts AC
502856 D2022H10BA White
Double pole with leads, 22 Amp 45
502443 D2022H10BB Ivory
502917 S2025H10AA White Single Pole with leads, 25 Amp 51
502924 D2025H10BA White Double pole with leads, 25 Amp 60
Page 84
84
Thermostats & Controls
TW Series
Features
• Single and double pole models
• Wire leads
• Tamper resistant
Load Rating
• 22 Amps resistive @ 120 VAC
• 18 Amps resistive @ 277 VAC
UPC#
686334
502009 TW145 SP, Beige with Leads Tamper Resistant 59
502016 TW146 DP, Beige with Leads Tamper Resistant 69
MODEL DESCRIPTION TEMPERATURE SCALE LIST
Master Carton: 25 Pcs, 12 lbs. (varies slightly by model), 16” x 14” x 5.5”
Washdown Series
Features
• Single and double pole models
• Rain tight NEMA 4X rating
UPC#
686334
523424 TW155A SP, Rain tight 40-110oF 179
523431 TW255A DP, Rain tight 40-110oF 209
MODEL DESCRIPTION TEMPERATURE SCALE LIST
22 Amps @ 120/250/277 VAC, 5” x 5” x3” Case
• Stainless steel hardware
• Coil capillary temperature sensor
Industrial Series
Features
• Coil capillary (CKT) models
• Bi-Metal models (KT)
• Rugged steel case
• SPST & SDPT models
• Hard wired models rated for 22A resistive @125-250 VAC
• Corded models rated for 13A resistive @125VAC
UPC#
686334
534048 CKTD110 SPDT Heat or Cool 40 - 110oF Wire Leads F 110
534086 KT110 SPST Heat Only -10 - 100oF Wire Leads C & F 46
534109 KT121 SPST Heat Only -10 - 100oF 6’ Cord/Plug C & F 51
534178 KTD110 SPDT Heat or Cool -10 - 100oF Wire Leads C & F 47
534369 KTO110 SPST Cool Only -10 - 100oF Wire Leads C & F 47
534215 KTO121 SPST Cool Only -10 - 100oF 6’ Cord/Plug C & F 51
MODEL DESCRIPTION RANGE CONNECTIONS SCALE LIST
Master Carton: 13.75” x 14” x 9”, Qty 9-12, 14lbs.-16lbs. depending on model
L Series
Features
Features
• 6’ or 8’ Capillary
• 6’ or 8’ Capillary
• Rugged steel cage
• Rugged steel cage
• SPDT for Heat or Cool
• SPDT for Heat or Cool
UPC#
686334
534260 L06Y-01 SPDT Heat or Cool 0 - 90oF 6’ F 77
534277 L08Y-01 SPDT Heat or Cool 0 - 90oF 8’ F 90
MODEL DESCRIPTION RANGE CAPILLARY SCALE LIST
Master Carton: 13.75” x 14” x 9”, 12 Pcs, 18lbs.
• 25A resistive
• 25A resistive
• Rated differential of 6°F
• Rated differential of 6°F
Page 85
Thermostats & Controls
Electromechanical Humidistat
• 4.4 amp @ 120VAC
• 2.2 amp @ 240VAC
Standard Models
85
Features
• 50VA @ 24VAC - 240VAC
• 10% - 60% relative humidity range
T4398A 1021
Precision Mechanical
UPC#
686334
523370 H46D1214
MODEL DESCRIPTION LIST
Electromechanical De-Humidistat
• 4.4 amp @ 120VAC
• 2.2 amp @ 240VAC
Standard Models
UPC#
686334
589147 H1D1AA
MODEL DESCRIPTION LIST
Honeywell Line Voltage Thermostats
• Heat only thermostats
• Accurate temperature control
Standard Models
UPC#
686334
503303
MODEL VOLTAGE DIMENSIONS DESCRIPTION LIST
T4398A
1021
120-240 2.875”x4.375”x2.00D
Humidistat/Electromechanical
Features
• 50VA @ 24VAC - 240VAC
• 10% - 60% relative humidity range
Dehumidistat/Electromechanical
Features
• 22 Amp resistive for mechanical models
Precision Electric Heating. SPST,
50-80 OF,
22 Amp @ 120-240V 19 Amp @
277V
181
69
62
TL8230A 1003
Electronic Programmable
RFT-1 shown with
UT thermostat
RFR-5
• Heat only thermostats
• Accurate temperature control
UPC#
686334
503365
MODEL VOLTAGE DIMENSIONS DESCRIPTION LIST
TL8230A
1003
Wireless RF Interface Series
• Heat only, Cool only
• 4 wire Heat/Cool
• Standard 2 stage Heat/ 1 Stage Cool Heat Pumps
RFT-1
• Multistage heating and/or cooling equipment
UPC#
686334
523554 RFT-1
523561 RFR-5
523578 RFKit-5 RFT-1 & RFR-5 Package
MODEL DESCRIPTION VOLTAGE CONNECTIONS LIST
Features
• 16 Amp resistive for electronic models
• Energy Star compliant.
Standard Models
240/208 2.70”x4.90”x.90D
Features
RF Thermostat Transmitter
Dim: 4” x 5” x .875”
RF Relay Interface
Dim: 4.5” x 6” x 1.25”
Electronic Programmable Line
Voltage DPST, 15 Amp, 40-86 OF
179
• Works with most low voltage thermostats
• Temp Range: 50-130 F
• Max Operating Range: 50 Feet
2-AAA Batteries 6 Wires 100
24 VAC
2 AAA
24 VAC
R-C-R1
1-2-3-4-5
R-C-R1
1-2-3-4-5
100
200
Page 86
86
Thermostats & Controls
Low Voltage Programmable Thermostats
Features
• 7 Day, 4 Settings Per Day
• Pre-Programmed or Custom Settings
Standard Models
• Control Accuracy +/- 1oF of Setpoint Temp
• Backlit Display, Energy Star Compliant
TH115-A-024T
TH147-P
UPC#
686334
523400 TH115-A-024T
• 7 Day, 4 Settings Per Day
• Pre-Programmed or Custom Settings
MODEL DESCRIPTION LIST
Standard Models
UPC#
686334
523585 TH147-P
MODEL DESCRIPTION LIST
7 Day, 4 Settings per Day, Heating/Cooling, 1 Stage Heat/Cool
Temp Range Heat:41-82OF, Cool:59-95OF
2 Stage Low Voltage Thermostat
Heat Only
Temp Range:40-86OF
Dims:4.89”H x 2.79”W x .91”D
Features
• Control Accuracy +/- 1oF of Setpoint Temp
• Backlit Display, Energy Star Compliant
Dims: 5”W x 3”H x 1”D,
121
144
TW123
Features
• 24V single or 2 stage heat and cool
• Gas, oil, or electric with air conditioning.
• Heat only, Heat only with fan, Cool only.
• Battery only, common wire only or common wire with battery backup.
• System settings - Heat, Off, Cool, Auto, Emergency Heat.
• Temperature range - Heat 40-90oF, Cool 50-99oF.
• Dimensions: 3-9/16” H x 5-13/16” W x 1-1/2” D
Standard Models
UPC#
686334
691116 TW123 / TH5220D 750MV - 2DV
MODEL VOLTAGE
TEMP
RANGE
40-90 Heat 50-99 Cool
Round - Low Voltage
Features
• Heat only for 24V heating systems
• White color • Temperature range - 50o - 90oF
• Does not contain Mercury
• Dimensions 3-11/16” diameter
Standard Models
UPC#
686334
MODEL DESCRIPTION VOLTAGE MAX AMP LIST
MAX
AMP
1.0 337
LIST
260008 A6176 Heat/Cool 24 VAC 1.0 88
Page 87
Thermostats & Controls
UT Series - Low Voltage
Features
• Vertical or horizontal mounting
• Long life sealed contacts
• Does not contain Mercury
• Leveling not required
• Fahrenheit and Celsius temperature scales
• 2-3oF rated differential
• Anticipator (except UT9001)
Standard Models
UPC#
686334
523059 UT1001 Heat Only 24VAC or MV R &W None 17.60
523066 UT3001 Cool Only 24 VAC R, Y & G Cool/Off Fan/Auto 18.15
523134 UT6001 Deadband 24 VAC R, W & Y None 19.25
523073 UT8001 Heat/Cool 24 VAC RC, RH, W, Y, & G
523110 UT9001 Heat Only Millivolt R & W None 17.60
MODEL DESCRIPTION VOLTAGE TERMINALS SWITCHES LIST
Heat/Off/Cool Fan/
Auto
Master Carton: 50 pcs, 17 lbs, 19” x 11.5” x 9”
19.25
RK Series - Low Voltage
Features
• Heat only models
• Positive off
• Does not contain Mercury
• Leveling not required
• Long life sealed contacts
• Fahrenheit and Celsius temperature scales
• 2-3oF rated differential
Standard Models
87
Two switch unit shown.
UPC #
686334
526012 RK120EAA Heat Only 24VAC or MV 50o-90oF Yes 17.60 526203 RK124EAA Heat Only 24VAC or MV 35o-75oF Yes 17.60 526050 RK130EAA Heat Only Millivolt 50o-90oF No 14.85 526326 RK134EAA Heat Only Millivolt 35o-75oF No 14.85 526142 RKWP1AA Wall Plate NA NA NA 3.85
MODEL DESCRIPTION VOLTAGE RANGE ANTICIPATOR LIST
Master Carton: 100 Pcs, 24 lbs, 16.5” x 15” x 8”
Low Voltage Relays
Features
• Snap action switch
• 1/2” male conduit spud
• 45 second average time delay
• Temperature range - 50o - 90oF
• Built-In transformer
Standard Models
UPC#
686334
260039 24A05A-1 120 Volts
260046 24A05E-1 208 Volts
260053 24A01G-3 240 Volts
260107 24A06G-1 240 Volts
MODEL
PRIMARY VOLTAGE
DESCRIPTION LIST
Single Switch, single throw with In-Built Transformer for
remote mounting or in a factory provided optional enclosure
Two switch, single throw with In-Built Transformer, 25
Amps per switch
TG Series Thermostat Guards
Standard Models
179
264
Features
• 8 tumbler locks
UPC#
686334 589123 TG1 Plastic Stat Guard/ 6.25” x 3.625” x 3.25” Opening 32 589109 TG1B Metal Stat Guard/ 5.25” x 4.625” x 3” Opening 57 589130 TG2 Plastic Stat Guard/ 5.25” x 4.625” x 3.25” Opening 37 589161 TG2B Metal Stat Guard/ 6.25” x 3.625” x 3.25” Opening 57
589116 TG3 Plastic Stat Guard/ 8.125” x 4.625” x 3.625” Opening 37 589178 TG3B Metal Stat Guard/ 6.75” x 4.50” x 3.50” Opening 70 523615 TG4 Plastic Stat Guard / 3.50” x 3.937” x 1.75” Opening 37 523622 TG5 Plastic Stat Guard / 5” x 3.31” x 1.75” Opening 37 523639 TG6 Plastic Stat Guard / 5.75” x 4.625” x 1.75” Opening 37
MODEL DESCRIPTION LIST
Page 88
88

Thermal Area Treatment Heaters

Sizing formula for TAT Series heaters: 50 Watts of heat per square foot of heated space or 50W/sq ft.
Example: An 800 square foot structure will require 40,000 Watts of heat to obtain 150 degrees of prolonged heat to be effective. (800 sq ft x 50 Watts per square foot = 40,000 Watts of heat or 40KW of heat)
Product Features
• Heavy duty industrial construction
• Forward curved centrifugal blower
• High Temperature ball bearing motor
• Optional replaceable lter
• Single point power connection
• 24 volt control
• Heavy duty spiral nned elements constructed of stainless steel
• Safety devices include airow switch, automatic limit control and manual reset limit control for secondary protection
• Disconnect switch and Unit Mounted Thermostat with range of up to 120 to 150
• The “TAT” series is sold as a system that includes the base unit, three supplemental units and the remote timer/ temperature control (supplemental units may be purchased separately if necessary)
o
F
Product Specications
APPLICATIONS:
• The "TAT" series is designed to heat small and mid-sized rooms up to 150 heating to areas infected with insects. It kills adult insects and will dehydrate larvae and eggs, making them unable to hatch. Although chemical sprays only target adult insects, they can be used before utilizing the "TAT" system in order to kill the adult insects.
• The system is designed to bring the temperature up to 150
o
F in one hour or less, if all preliminary requirements are
met.
• The "TAT" system may be used for water remediation, as well, in combination with adequate ventilation. Specic
models for water remediation are also available.
TAT BASE UNIT:
• Heavy duty stainless steel spiral n heating elements
• High temperature, ball bearing 1/3 HP - 1075 RPM blower motor
• Forward curved centrifugal blower-900 CFM of air output
• Safety devices include airow switch, disconnect switch, automatic limit control and manual reset limit control for
secondary protection
• 50 Amp unit may be linked to a 30 Amp unit to provide heating for larger spaces.
• Timer/Temp controller may be used to control both units but must use the 50 Amp base unit as the master.
SUPPLEMENTAL TAT CONVECTORS
• 3 convectors are an integral part of each TAT system
• 120 Volt, 15 Amp (Standard wall plug) - 5120 BTU size
• Supplied with 25' prewired cable that connects them to the TAT base unit control section with a three pin connector
• If used in front of windows or large glass doors, they will reduce heat loss and provide more even heating
o
F. This provides effective portable
TIMER/TEMPERATURE CONTROL UNIT
• Timer/Temp Controller is an integral part of the TAT system
• 24 Volt control device that controls the heat output of the TAT base unit and up to three TAT convectors for an operating range of 120 - 150
o
F and for a time period of 1 -10 hours after the preset temperature is reached
• Supplied with a 25' prewired cable that connects to the TAT base unit control section using a four pin connector
• Mounts on Door outside the area being treated.
• LED lights will indicate when treatment is complete
Page 89
5"
7"
3"
CORD LENGTH: 6'10"
16AWG USASI HPN CORD
CORD LENGTH: 25' 18AWG SHIELDED CABLE
16AWG USASI HPN CORD
H
L
W
L
W
Thermal Area Treatment Heaters
Standard Models
UPC#
686334
STYLE MODEL
NUMBER
BASE
UNIT
KW
BASEBOARD
PERIMETER HEATER KW
TOTAL
SYSTEM
KW
BASE
UNIT
VOLTS
BASEBOARD
PERIMETER
HEATER
VOLTS
PHASE
397568 TAT5-240-1/3BB/1T 5.3 1.5 (X3) 9.8 240 120 1 24 12.5 Nema 10-30 Nema 5-15 12,900
397629 TAT5-208-1/3BB/1T* 5.3 1.5 (x3) 9.8 208 120 1 27 12.5 ---- Nema 5-15 12,900
397551 TAT8-240-1/3BB/1T 8.4 1.5 (X3) 12.9 240 120 1 37 12.5 Nema 14-50 Nema 5-15 13,500
397612 TAT8-208-1/3BB/1T* 8.4 1.5 (x3) 12.9 208 120 1 42 12.5 ---- Nema 5-15 13,500
397520 TAT20-480-3/3BB/1T 20 1.5 (X3) 24.5 480 120 3 26 12.5 Nema L16-30 Nema 5-15 15,000
397582 TAT-ILC-25 25’ Shielded Cable 250
*208 Volt models do not have a cord supplied
Accessories
BASE
UNIT
AMP
BASEBOARD
PERIMETER
AMP-EACH CIRCUIT (3)
PLUG TYPE
LIST
BASE UNIT PERIMETER
89
UPC#
686334
MODEL DESCRIPTION HP CFM / RPM MAX AMPS VOLTS WT (LBS) LIST
397636 TAT-24-FAN-120V-1 Thermal Area Treatment Floor Fan 1/3 5000/1160 3.1 120 30 325
UPC#
686334
MODEL DESCRIPTION KW BTU VOLTS PHASE AMPS TEMP RISE WT (LBS) LIST
397834 TAT-30 30KW Salamander 30 102390 480 3 36 43 115 2537
397841 TAT-45 45KW Salamander 45 153585 480 3 54.2 70 125 4196
Product Dimensions
L
W
• Safety yellow heater enclosure with safety screens on both air intake and output openings.
• Optional 25’ long SO type cord, ready for plug attachment is available for each model.
• Long-life nned tubular heating elements.
• Thermostat adjustment 120° to 150° F.
H
• Two 10” rear wheels and a front locking caster.
• High-limit thermal cutout switch with manual reset.
• 2200 CFM
• Fan only operation feature
10.625"
HANDLE ADDS 6" TO L"
TAT 30-45
CORD LENGTH: 25' 18AWG SHIELDED CABLE
CORD LENGTH: 6'10"
H
5"
7"
3"
H
L
TAT-24-FAN-120V-1
48"
WT. (LBS)
W
MODEL
• Single speed
• Head tilts 360
o
• Coated steel guards
• SJT type 3 conductor
• Steel hub / Aluminum blades
• Meets OSHA standards
LENGTH WIDTH HEIGHT
8.75"
DIMENSIONS
TAT-8-240-1 39” 26.5” 18” 180 TAT-5-240-1 39” 26.5” 18” 180
TAT-20-480-3 39” 30.5 18” 234
TAT-1-120-1 48” 8.5” 9.5” 23
Remote Timer 11” 3” 4.5” 5
TAT 30, 45 37” 24” 39” 115/125
TAT24-FAN-120V-1 10.5” 26” 26” 30
Page 90
90
Thermal Area Treatment Heaters
How It Works:
Washer
Move dryer, connect 30 Amp unit to 30 Amp dryer power supply.
Seal all exterior windows and doors before extermination process begins.
Dryer
30 Amp Power Supply
Heater Line 2
Heater Line 3
Heater Line 1
Move range/electric stove, connect 50 Amp unit to 50 Amp range power supply.
Use only if two systems are used together
Heater Line 2
30
AMP
TAT Base
Unit
Stove/Range
Master/Slave Unit Control Tether.
50 Amp Power Supply
Heater Line 1
50
Heater Line 3
AMP
TAT Base
Unit
Timer Control Line
Timer Control Unit
Diagram is for demonstrative purposes only and does not represent any actual structure or living environment. Two units may not be required for all situations, exterior climate, structure insulation, electrical service, and square footage all factor into effective treatment with this system.
Page 91
Hotpod Supplemental Duct Mounted Heating System
8” Hotpod
Patented Patent No. 8,285,127
6” Hotpod
Standard HotPod Models
HotPod - Features
• Use to heat cold rooms or additions without upgrading central system
Fan only operation for increased cfm output for A/C cycles
• 6" 1000/500 Watt and 8" 1440/720 Watt models available
• Two stage operation
• 120V corded and hard wire models available
• 10' Cord length on corded models
• Zero clearance for all models
• All models include UT8003 low voltage thermostat
• Optional wireless thermostat
• Silent boot option available for rigid duct applications Note: Silent Boot can only be used with rigid duct work
91
UPC#
686334
290074 HP6-1000120-2T 6” INLET, HARDWIRE 1000/500 120 8.33 26 4 1500 130 NA 10 1/2 x 8 1/2 x 6 513 290043 HP6-1000120-2CT 6” INLET, WITH CORD SET 1000/500 120 8.33 26 4 1500 130 5-15P 10 1/2 x 8 1/2 x 6 538 290081 HP8-1440120-2T 8” INLET, HARDWIRE 1440/720 120 12.6 23 6 1500 210 NA 11 x 10 1/2 x 8 625 290067 HP8-1440120-2CT 8” INLET, WITH CORD SET 1440/720 120 12.6 23 6 1500 210 5-15P 11 x 10 1/2 x 8 663
MODEL DESCRIPTION WATTS VOLTS
MIN.CIRC.
SIZE (AMP)
TEMP
RISE (F)
WT RPM CFM
NEMA
PLUG
DIMENSION
L X W X H
LIST
Multi-Pak Models - Includes 4 Hotpods
UPC#
686334
290036 HP6-1000120-2T 4 PACK 6” INLET, HARDWIRE 1000/500 120 8.33 26 16 1500 130 NA 10 1/2 x 17 x 12 2052 290111 HP6-1000120-2CT 290050 HP8-1440120-2T 4 PACK 8” INLET, HARDWIRE 1440/720 120 12.6 23 25 1500 210 NA 10 1/2 x 20 x 16 2500 290128 HP8-1440120-2CT 290333 HP6H-12PK* 12 PACK 6” INLET, HARDWIRE 1000/500 120 8.33 26 58 1500 130 NA 21 x 14 1/2 x 43 6156 290340 HP6C-12PK* 290357 HP8H-12PK* 12 PACK 8” INLET, HARDWIRE 1440/720 120 12.6 23 82 1500 210 NA 27 1/4 x 14 1/2 x 52 7500 290364 HP8C-12PK*
MODEL DESCRIPTION WAT TS VOLTS
4 PACK 6” INLET, WITH CORD SET
4 PACK 8” INLET, WITH CORD SET
12 PACK 6” INLET, WITH CORD SET
12 PACK 8” INLET, WITH CORD SET
1000/500 120 8.33 26 16 1500 130 5-15P 10 1/2 x 17 x 12 2152
1440/720 120 12.6 23 25 1500 210 5-15P 10 1/2 x 20 x 16 2652
1000/500 120 8.33 26 58 1500 130 5-15P 21 x 14 1/2 x 43 6456
1440/720 120 12.6 23 82 1500 210 5-15P 27 1/4 x 14 1/2 x 52 7956
*includes 1 HotPod display
Note: Multi-Pak specications (watts, volts, etc) are for each individual hotpod in the pack excluding weight.
MIN.CIRC.
SIZE (AMP)
TEMP
RISE (F)
WT.
LBS
RPM CFM
NEMA
PLUG
DIMENSION
L X W X H
LIST
Silent Booster Supplemental Duct Mounted Boosting System
Silent Booster - Features
• 120V corded and hardwire models available
• Adds 120 CFM Boost to duct heating or ventilation applications
• Can utilize optional TPI SilentBoot™ for whisper quiet operation in rigid duct application.
• 14” of duct, 4’ from register is all that is needed for installation
• Optional wireless thermostat can be utilized to control Silent Booster™ to increase room comfort
Moisture Control System - Features
• 120V, 8” Ducted Booster Fan; De-humidistat included
8” Silent Booster
6” Silent Booster
Standard Silent Booster Models
UPC#
686334 290371 SB6-120-T 6” SILENT BOOSTER (Hardwire) 120 15 4 1500 130 NA 10 1/2 x 8 1/2 x 6 225 290388 SB6-120-CT 6” SILENT BOOSTER (w/Cord Set) 120 15 4 1500 130 5-15P 10 1/2 x 8 1/2 x 6 250 290395 SB8-120-T 8” SILENT BOOSTER (Hardwire) 120 15 4 1500 210 NA 11 x 10 1/2 x 8 250 290401 SB8-120-CT 8” SILENT BOOSTER (w/Cord Set) 120 15 4 1500 210 5-15P 11 x 10 1/2 x 8 275
290418 MCS120-8CT
MODEL DESCRIPTION VOLTS
MOISTURE CONTROL SYSTEM
8” MOISTURE CONTROL SYSTEM
6” to 8” adapters available
• Includes all ductwork and outside damper
• Uses Heavy Duty booster fan to eliminate humidity from basements, crawl spaces, or damp areas.
MIN.CIRC.
SIZE (AMP)
120 15 4 1500 210 5-15P 11 x 10 1/2 x 8 350
WT RPM CFM
NEMA
PLUG
DIMENSION
L X W X H
LIST
Page 92
92
Hotpod Accessories, Thermostats, Ready-Pack, and MFH Models
Hotpod Accessories And Thermostat
UPC#
686334
290098 SB-6* 6” SILENT BOOT 4 37.50
290104 SB-8* 8” SILENT BOOT 4 62.50
523578 RFKIT-5 WIRELESS TRANSMITTER 6 200
Silent Boot
* Can be used with Hotpod models as a noise attenuator
Hotpod Ready-Pack Self Contained Systems
Note: does not mount to exsisting duct work.
• Includes all you need to install a complete Hotpod system
• Ideal for room or ofce additions
• RF Thermostat is standard with our Ready-Pack models, simplifying installation even further - Eliminates the need for thermostat wiring.
• Same specications for 6” and 8” Hotpod models apply to Ready-Pack
models.
MODEL DESCRIPTION LIST
HP6-1000120-2TRP 6” INLET, 1000W, 120V, READY-PACK 1137
HP6-1000120-2CTRP 6” INLET, 1000W, 120V, READY-PACK WITH CORDSET 1200
HP8-1440120-2TRP 8” INLET, 1440W, 120V, READY-PACK 1350
HP8-1440120-2CTRP 8” INLET, 1440W, 120V, READY-PACK WITH CORDSET 1390
MODEL DESCRIPTION WT LIST
Ready-Pack self contained system
RFT-1
( Shown With UT8003
Thermostat)
RFKIT-5 - Patent Pending
What’s IncludedFeatures
• 6” or 8” Hotpod with RFKIT-5 wireless thermostat and transmitter
• One outlet and one return air grill
• Two 90 degree elbows
• Flexible duct (12.5’)
• 8" models include 2 reducers - 8” to 6”
RFR-5
MFH Series Hotpod - For those LARGER areas
Features
• When the standard Hotpod is not enough
• 240V model has 6’ cord set with a NEMA-6-15P Plug
• Unit contains air ow switch
• Zero inch (0”) clearance installation
• All units are shipped with our UT8003 low voltage thermostat
• All units obtain a 33 degree temperature rise
RP models are Ready-Pack models and do not need existing duct work
Standard Models
UPC# 686334 290135 MFHE-0300-6-EAA 6" INLETS, 1500 W, 120V,2 STAGE THERMOSTAT 1500 120 132 250 1500 1300
290197 MFHE-0300-6-EAARP UNIT ABOVE WITH FLEX, BOOTS, GRILLS 1500 120 145 250 1500 1738 290142 MFHE-0300-6-EAAC 6" INLETS, 1500 W, 120V,2 STAGE THERMOSTAT, CORD 1500 120 132 250 1500 1338 290203 MFHE-0300-6-EAACRP UNIT ABOVE WITH FLEX, BOOTS, GRILLS 1500 120 145 250 1500 1775 290173 MFHE-0300-6-HAA 6" INLETS, 2000W, 240V, 2 STAGE THERMOSTAT 2000 240 132 250 1500 1375 290234 MFHE-0300-6-HAARP UNIT ABOVE WITH FLEX, BOOTS, GRILLS 2000 240 145 250 1500 1812 290159 MFHE-0300-8-EAA 8" INLETS, 1500W, 120V, 2 STAGE THERMOSTAT 1500 120 135 250 1500 1325 290210 MFHE-0300-8-EAARP UNIT ABOVE WITH FLEX, BOOTS, GRILLS, REDUCERS 1500 120 148 250 1500 1862 290166 MFHE-0300-8-EAAC 8" INLETS, 1500W, 120V, 2 STAGE THERMOSTAT,CORD 1500 120 135 250 1500 1362 290227 MFHE-0300-8-EAACRP UNIT ABOVE WITH FLEX, BOOTS, GRILLS, REDUCERS 1500 120 148 250 1500 1900 290180 MFHE-0300-8-HAA 8" INLETS, 3000W, 240V, 2 STAGE THERMOSTAT 3000 240 135 250 1500 1412 290241 MFHE-0300-8-HAARP UNIT ABOVE WITH FLEX, BOOTS, GRILLS, REDUCERS 3000 240 148 250 1500 1950
MODEL DESCRIPTION WAT T S VOLTS WT CFM RPM LIST
Fresh Air Make Up Units - Features
• Can be used with existing systems for fresh air intake
• Includes replaceable lter
• All units include duct stat and disconnect switch
• Available with 6" inlet and outlet only
Standard Models
UPC# 686334 290258 MFHE-0300-6-HAAF2D 6" INLETS, 3000W, 240V, FILTER, DUCT STAT 250 1500 1750 290265 MFHE-0300-6-FAAF2D 6" INLETS, 2000W, 208V, FILTER, DUCT STAT 250 1500 1700
MODEL DESCRIPTION CFM RPM LIST
Page 93
7200 Series Plenum Heater
HOW TO DESIGNATE A MODEL:
F 3 E 72 15 2 T
Phase
Element Voltage
F = 208V H = 240V G = 277V P = 480V
1 = Single Phase 3 = Three Phase
Motor Voltage
E = 120 G = 277 P = 480
Series Number
Element KW
3KW through 50KW
Manufactured in U.S.A.
Product Specications
• 20 gauge galvanized cabinet.
• Variable speed motor, factory set at maximum. Motor speed
can be eld adjusted to increase heat rise.
• Acoustically insulated with 1” berglass.
• Access panels on both sides of cabinet.
• 24 Volt controls.
• Air ow switch.
• Terminal blocks.
• Single point connection.
• Dust tight control enclosure.
• Filter rack on inlet with throw away lter.
• Inlet and outlet screens and duct connection.
• Automatic primary limit control and secondary fuse link.
• Optional wall thermostat, unit thermostat or SSR control which proportionally regulates heat output.
• Disconnect switch.
Standard Models
UPC#
686334
617680 F1G7203
606240 G1G7203 277/1 11.83 277 1 606905 F3G7203 208/3 9.32 277 1
617574 P3G7203 480/3 4.6 277 1 617666 F1G7205
606165 G1G7205 277/1 19.15 277 1.1 606424 F3G7205 208/3 14.97
606110 P3G7205 480/3 7.11 277 1.1 606554 F3E7210
617581 P3G7210 480/3 13.72 277 1.7 606516 F3E7210-2 208/3 33.05
617659 P3G7210-2 480/3 13.72 277 1.7 608602 F3E7215
606257 P3G7215 480/3 19.74 277 1.7 606943 F3E7215-2 208/3 46.93
606066 P3G7215-2 480/3 19.74 277 1.7 608831 F3E7220-2
606394 P3G7220-2 480/3 26.55 277 2.5 534420 F3E7223-2 617888 H3G7223-2 240/3 59.63 277 4.3 606875 P3G7225-2 25 480/3 34.37 277 4.3 2600 534437 H3G7230-2 606745 P3G7230-2 480/3 42.38 277 6.3 3570 618007 P3G7235-2 35 480/3 48.39 277 6.3 3780 606851 P3G7240-2 40 534444 P3G7245-2 45 480/3 62.72 277 8.6 4750 606417 P3G7250-2 50 480/3 68.74 277 8.6 5100
MODEL KW CFM RANGE
3 70-270
5 200-650
10 500-1200
15 500-1200
20 750-1600
23
1300-2000
30
1800-2800
2000-3600
VOLTS / PHASE
208/1 15.4
208/1 25.13
208/3 33.05
208/3 46.93
208/3 63.81
208/3 74.84
240/3 78.47
480/3 56.71
TOTAL
AMPS for
MOTOR &
HEATER
STAGE
1
1
1
1
2
1
2
2
2
2
2
MOTOR
VOLTAGE
277 1
277 1.1
277 1.1
120 5.3
120 5.3
120 5.3
120 5.3
120 8.3
120 11
277 6.3
277 8.6
FULL LOAD
AMPS for
MOTOR ONLY
MOTOR H.P.
2 MOTORS @
1/2 H.P. EACH
2 MOTORS @ 3/4 H.P. EACH
Heater Stages
See model chart for KW options.
1/15 98
1/6 11 8
1/4 141
1/2 163 2250534413 H3G7220-2 240/3 50.61 277 2.5
3/4 201
Blank = One 2 = Two
Control System
Blank = None T = Unit Thermostat
WT.
(LBS)
278
319
SSR = SSR Control
PRICE
1570606561 H1G7203 240/1 13.5 277 1
1620617765 H3G7203 240/3 8.21 277 1
1620617956 H1G7205 240/1 21.93 277 1.1
1650617994 H3G7205 240/3 13.12 277 1.1
1730617734 H3G7210 240/3 25.75 277 1.7
1810534390 H3G7210-2 240/3 25.75 277 1.7
1810608848 H3G7215 240/3 37.78 277 1.7
1900534406 H3G7215-2 240/3 37.78 277 1.7
2800
3900
4650
93
LIST
Page 94
94
7200 Series Plenum Heater
Product Dimensions
H
H
Discharge
Discharge
Screen
Screen
Air Flow
AIR FLOW
3”
3"
FILTER = A x B
FILTER=A X B
B
B
Filter Rack
L
L
Air
Air
Inlet
Inlet
*
5 1/2”
5 1/2" STANDARD
2"
2”
STANDARD
Filter Rack
Inlet
Inlet Screen
Screen
A
A
7200 Series A B L
3 KW 12” 14” 28” 14” 8”
7200
5 KW 14” 18” 36” 18” 8”
SERIES
3 KW
10 & 15 KW 18” 18” 36” 18” 10”
5 KW
20 KW 18” 22” 36” 22” 10”
10&15 KW
23 & 25 KW 18” 26” 36” 26” 10”
20 KW
Note: Control panel access standard as shown.
23&25 KW
For panel on opposite side access specify and order (Figure 5).
DIMENSIONS
DIMENSIONS
A B L
18" 18"
14"
18"
18"
22"
18"
18"
Note:
36"
36" 36"
36"
DISCHARGE
W H
DISCHARGE
W H
14"14"12" 28"
18"
22"
26"26"
8" 8"
10"
10"
10"
Control Panel Access Standard as Shown For Panel on Opposite
1” FILTER SLOT
OF UNIT
1" Filter Slot
* Control box depth depends on
actual components. Consult
Disconnect
Disconnect Switch
Switch
ACCESS DOORS
ACCESS DOORS
ON BOTH SIDES
W
W
ON BOTH SIDES
OF UNIT
Side Access Specify And Order Figure 5.
factory for exact dimensions.
ELECTRIC
ELECTRIC
CONTROL
CONTROL
PANEL
PANEL
H
H
DIMENSIONS
DIMENSIONS
7200
SERIES
7200 Series A B L
25-30-35 KW
25-30-35 KW 18” 44” 36” 44” 10”
40-45-50 KW
40-45-50 KW 18” 52” 36” 52” 10”
A B
18
DISCH'GE
W X H
DISCHARGE
44 36
44 X 10
W H
52 X 10
5218
L
L
Discharge
Discharge
Screen
Screen
W
W
L
NOTE: Control Panel Access
Note: Control panel access
Standard as Shown
standard as shown. For panel
For Panel on Opposite
on opposite side access specify
36
Side Access Specify And Order Figure 5.
and order (Figure 5).
2”
2"
3"
3”
5 1/2’
STANDARD
STANDARD
5-1/2"
Filter Rack
Filter Rack
*
Disconnect
Disconnect Switch
Switch
ELECTRIC CONTROL
Electric Control Panel
PANEL
B
ACCESS DOORS
Access
ON BOTH SIDES
On Both Sides Of Unit
OF UNIT
A
A
1" Filter Slot
1” FILTER SLOT
Page 95
7300 Series Plenum Heater
HOW TO DESIGNATE A MODEL:
F 3 E 73 15 2 T
Phase
95
Element Voltage
F = 208V H = 240V G = 277V P = 480V
1 = Single Phase 3 = Three Phase
Motor Voltage
E = 120 G = 277 P = 480
Series Number
Element KW
3KW through 18KW
Heater Stages
See model chart for KW options.
Control System
Blank = One 2 = Two
Manufactured in U.S.A.
The 7300 Series LowBoy Plenum Heater is designed to t jobs where the clear space between the ceiling
and the oor above is as small as 11-3/4 inches.
Product Specications
• 20 gauge galvanized cabinet.
• Variable speed motor, factory set at maximum. Motor speed
can be eld adjusted to increase heat rise.
• Acoustically insulated with 1” berglass.
• Access panels on bottom of unit.
• 24 Volt controls.
• Air ow switch.
• Terminal blocks.
• Single point connection.
• Dust tight control enclosure.
• Filter rack on inlet with throw away lter.
• Inlet and outlet screens and duct connection.
• Automatic primary limit control.
• Optional wall thermostat, unit thermostat or SSR control which proportionally regulates heat output.
• Disconnect switch.
Standard Models
SSR = SSR Control
Blank = None T = Unit Thermostat
UPC#
686334
618076 F1G7305
606301 G1G7305 277/1 20
617642 F3G7305 208/3 15
606455 P3G7305 480/3 8
609968 F3E7310
617598 P3G7310 480/3 14 277 2
606363 F3E7310-2 208/3 32
617697 P3G7310-2 480/3 14 277 2
534482 H3G7312
534499 P3G7312 480/3 17 277 3
608596 F3E7312-2 208/3 41
617703 P3G7312-2 480/3 17 277 3
534529 H3G7315
608725 P3G7315 480/3 21 277 3
618106 F3E7315-2 208/3 49
617536 P3G7315-2 480/3 21 277 3
608763 P3G7318
606189 P3G7318-2 480/3 25 2 277 3 2800
MODEL KW
5
10
12
15
18
CFM
RANGE
170-950
270-1500
VOLTS/
PHASE
208/1 26
208/3 32
240/3 32
240/3 39
480/3 25 1 277 3 2750
TOTAL AMPS for
MOTOR & HEATER
STAGE
1
1
2
1
2
1
2
MOTOR
VOLTAGE
FULL LOAD AMPS
for MOTOR ONLY
277 2
277 2 1760534451 H3G7305 240/3 14
120 4
120 4
277 3
120 8
277 3
120 8
MOTOR H.P.
1/4 163
2 Motors @
1/4 HP Each
WT.
(LBS)
219
LIST
PRICE
1700617543 H1G7305 240/1 22
1950617734 H3G7310 240/3 26 277 2
2000534468 H3G7310-2 240/3 26 277 2
2500
2550534505 H3G7312-2 240/3 32 277 3
2600
2650608510 H3G7315-2 240/3 39 277 3
Page 96
96
H
H
Air Flow
Air Flow
A
A
W
W
L
L
Discharge
Discharge
Screen
Screen
B
B
7300 Series Plenum Heater
Product Dimensions
6"
6”
Inlet
Inlet
Screen
Screen
G
2”
2"
F
F
G
8 1/2"
8 1/2”
Filter Rack
Filter Rack
Air Flow
Air Flow
1" Filter
1” Filter
ELECTRIC CONTROL
PANEL
Disconnect
Disconnect
Switch
Switch
ELECTRIC
CONTROL
Panel
C
C
7300 Series C F G H L W
7300 SERIES
5 & 10 KW
5 & 10 KW 28, 75” 1” 6” 11.75” 45” 26” 8” 10”
Note: Dimension C and G will vary
DIMENSIONS
28.75" 1"H11.75"
NOTE:Dimension C and G Will Vary With Accessories.
with accessories.
5 1/2”
5 1/2"
Note: Control panel access
NOTE: Control Panel access
standard as shown. For panel
Standard as shown
on opposite side access specify
For Panel on Opposite
and order (Figure 5).
Side Access Specify And Order Figure 5.
16 1/2"
16 1/2”
Inlet
DIMENSIONS
C F G
6"
L
Inlet
DISCHARGE
DISCHARGE
W
A B
A B
26"
10"8"45"
6"
6”
8 1/2"
8 1/2”
Note: Control panel access
NOTE:
standard as shown. For panel
Control Panel Access
on opposite side access specify
Standard as Shown For Panel On Opposite
and order (Figure 5).
Side Access Specify And Order Figure 5.
Filter Rack
Filter Rack
Air Flow
Air Flow
(2) 1" Filters
(2) 1” Filters
33 "
33”
Inlet
Inlet
H
H
L
L
2"
2”
F
F
A
AIR FLOW
Air Flow
A
Discharge
Discharge
Screen
Screen
B
B
W
W
DIMENSIONS
7300 Series C F G H L W
12, 15, & 18 KW 28, 75” 2” 6” 11.75” 45” 43” 8” 20”
Note: Dimension C and G will vary with accessories.
7300 SERIES
12,15 & 18 KW
NOTE:Dimension C and G Will Vary With Accessories.
DIMENSIONS
C F G
28.75" 2"H11.75"
Disconnect
Disconnect
Switch
Switch
6"
INlet
Inlet
Screen
Screen
G
G
ELECTRIC CONTROL
ELECTRIC
PANEL
CONTROL
PANEL
C
C
DISCHARGE
W
L
45"
43"
DISCHARGE
A B
A B
20"8"
Page 97
PD Series Packaged Duct Heater
Manufactured in U.S.A.
Standard Features
• Galvanized Steel Element Rack - Always 1” shorter than duct height and 1/2” shorter than duct width to allow insertion clearance
• Galvanized Steel Compartment with 1/2”
berglass Insulation & Hinged Cover
• Door Interlock Disconnect Switch
• Primary Automatic Reset Temp Limiting Control
• Load Carrying Secondary over Temperature Protective Device(s)
• Denite Purpose Magnetic Contactor(s)
• Differential Pressure Fan Inter-lock Switch
• Step Down Control Transformer / 24 Volt
• Permanently Attached Wiring Diagram on inside of Terminal Compartment Cover
Standard Models
97
UPC
686334
617000 PD5-128-1 5 617017 PD10-1810-1 10 18 10 4.75 6.5 28 41.7 2 37 1045 617024 PD15-1812-1 15 18 12 4.75 6.5 27 62.5 2 33 1224 617031 PD20-2012-1 20 20 12 9.125 7.5 31 83.3 2 37 1535 617048 PD25-2016-1 25 20 16 9.125 7.5 38 104.2 3 56 2447 617055 7PD2-128-1 2 617062 7PD3.5-128-1 3.5 12.6 801 617079 7PD5-128-1 5 18.1 1028 617086 8PD5-128-3 5 617093 8PD10-1810-3 10 18 10 4.75 6.5 22 27.8 1 27 918 617109 8PD15-1812-3 15 18 12 9.125 6.5 25 41.7 1 32 1068 617116 8PD15-1812-2-3 15 18 12 9.125 6.5 28 41.7 2 34 1123 617123 8PD20-2012-3 20 20 12 9.125 6.5 40 55.6 2 39 1358 617130 8PD25-2016-3 25 20 16 9.125 6.5 29 69.5 2 58 1368 617147 8PD30-2416-2-3 30 24 16 9.125 7.5 29 83.4 2 65 1947 617154 8PD30-2416-3 30 24 16 9.125 7.5 35 83.4 3 60 1980 617437 8PD35-2416-3 35 24 16 9.125 7.5 35 97.3 3 65 2114 617321 8PD40-2416-3 40 24 16 9.125 7.5 43 111.2 3 75 2670 617338 8PD45-3016-3 45 30 16 9.125 7.5 43 125.1 3 80 2726 617345 8PD50-3016-3 50 30 16 9.125 7.5 43 139 3 85 2781 617161 PD-128-3 5 617178 PD10-1812-3 10 18 10 4.75 6.5 22 24.1 1 26 835 617185 PD15-1812-1-3 15 18 12 4.75 6.5 20 36.2 1 30 934 617192 PD15-1812-2-3 15 18 12 9.125 6.5 26 36.2 2 33 957 617208 PD20-2012-3 19.9 20 12 9.125 6.5 28 47.9 2 39 1224 617215 PD25-2016-3 25 20 16 9.125 6.5 29 60.2 2 57 1368 617222 PD30-2416-2-3 30 24 16 4.75 6.5 25 72.3 2 57 1513 617239 PD30-2416-3-3 30 24 16 9.125 6.5 35 72.3 3 65 1580 617352 PD35-2416-3 35 24 16 9.125 7.5 35 84.3 3 65 1757 617369 PD40-2416-3 40 24 16 9.125 7.5 35 96.3 3 75 2025 617376 PD45-3016-3 45 30 16 9.125 7.5 43 108.4 3 80 2625 617383 PD50-3016-3 49.8 30 16 9.125 7.5 43 120 3 85 2737 617246 4PD5-128-3 5 617253 4PD10-1810-3 10 18 10 4.75 6.5 22 12.1 1 26 918 617260 4PD15-1812-3 15 18 12 4.75 6.5 20 18.1 1 30 968 617277 4PD15-1812-2-3 15 18 12 9.125 6.5 26 18.1 2 34 1112 617284 4PD20-2012-3 20 20 12 9.125 6.5 26 24.1 2 39 1135 617291 4PD25-2016-3 25 20 16 9.125 6.5 22 30.1 2 58 1169 617307 4PD30-2416-2-3 30 24 16 4.75 6.5 18 36.2 2 65 1201 617314 4PD30-2416-3-3 30 24 16 9.125 6.5 24 36.2 3 65 1268 617390 4PD35-2416-3 35 24 16 9.125 6.5 26 42.2 3 65 1624 617406 4PD40-2416-3 39.9 24 16 9.125 6.5 40 48.1 3 75 1836 617420 4PD50-3016-3 50 30 16 9.125 6.5 36 60.2 3 85 2225
MODEL NUMBER KW
POWER VOLTS/
PHASE
240-1
277-1 12 8 4.75 6.5 26
208-3
240-3
480-3
DUCT
WIDTH
DUCT
HEIGHT
W
12 8 4.75 6.5 26 20.9 1 22 779
12 8 4.75 6.5 26 13.9 1 22 899
12 8 4.75 6.5 26 12.1 1 21 756
12 8 4.75 6.5 26 6.1 1 21 867
A
DIMENSIONS
C E M
AMPS
7.2
CONTROL
STEPS
1 21
WT.
(LBS.)
LIST
779
Page 98

Product Index Listing

Model
Model
2605 20
2607 20
2610 20
2615 20
2620 20
2625 20
2630 20
2640 20
2650 20
8510 28
8512 28
8513 28
8514 28
8515 28
8516 28
8517 28
8518 28
8519 28
8520 28
8522 28
8523 28
8524 28
8525 28
8526 28
8527 28
8528 28
8529 28
8530 28
8532 28
8533 28
8534 28
8535 28
8536 28
8537 28
8538 28
8539 28
9128 56
9136 56
9148 56
9160 56
9172 56
9184 56
9196 56
9328 58
9336 58
9348 58
9360 58
9372 58
9384 58
9396 58
91108 56
Page
Page
Page
Model
Model
91120 56
93108 58
93120 58
316422 76
880435 76
880435 76
880442 76
880459 76
880466 76
880466 76
880497 76
880497 76
880510 76
880527 76
31939009 69
31940009 69
31941009 69
A1560 80
DBTS IECR 62
170-TS 79
178 TMC 79
188 TASA 79
18D-2-30CF 74
18D-2-80CF 74
198 TMC 79
222-30-TH-208V 68
222-30-TH-240V 68
222-30-TH-277V 68
222-30-TH-480V 68
222-30-THSS-208V 68
222-30-THSS-240V 68
222-30-THSS-277V 68
222-30-THSS-480V 68
222-60-TH-208V 68
222-60-TH-240V 68
222-60-TH-277V 68
222-60-TH-480V 68
222-60-THSS-208V 68
222-60-THSS-240V 68
222-60-THSS-277V 68
222-60-THSS-480V 68
222-90-TH-208V 68
222-90-TH-240V 68
222-90-TH-277V 68
222-90-TH-480V 68
222-90-THSS-208V 68
222-90-THSS-240V 68
222-90-THSS-277V 68
222-90-THSS-480V 68
222-A30-TH-208V 68
222-A30-TH-240V 68
Page
Page
Model
Model
222-A30-TH-277V 68
222-A30-TH-480V 68
222-A30-THSS-208V 68
222-A30-THSS-240V 68
222-A30-THSS-277V 68
222-A30-THSS-480V 68
222-A60-TH-208V 68
222-A60-TH-240V 68
222-A60-TH-277V 68
222-A60-TH-480V 68
222-A60-THSS-208V 68
222-A60-THSS-240V 68
222-A60-THSS-277V 68
222-A60-THSS-480V 68
223-30-TH-208V 69
223-30-TH-240V 69
223-30-TH-277V 69
223-30-TH-480V 69
223-30-THSS-208V 69
223-30-THSS-240V 69
223-30-THSS-277V 69
223-30-THSS-480V 69
223-60-TH-208V 69
223-60-TH-240V 69
223-60-TH-277V 69
223-60-TH-480V 69
223-60-THSS-208V 69
223-60-THSS-240V 69
223-60-THSS-277V 69
223-60-THSS-480V 69
223-90-TH-208V 69
223-90-TH-240V 69
223-90-TH-277V 69
223-90-TH-480V 69
223-90-THSS-208V 69
223-90-THSS-240V 69
223-90-THSS-277V 69
223-90-THSS-480V 69
24A01G-3 87
24A05A-1 87
24A05E-1 87
24A06G-1 87
303EX16RW 34
303EX16RW 46
303EX32RW 34
303EX32RW 46
303EX8RW 34
303EX8RW 46
305EX16 39
305EX32 39
305EX8 39
Page
Page
Model
Model
30R 34
30R2 34
30R7 34
30R8 34
32T1 46
32T2 46
3310EX33R 45
3310EX33WR 45
3320EX16 40
3320EX33 40
3380EX33 34
342-30-TH-208V 68
342-30-TH-240V 68
342-30-TH-480V 68
342-30-THSS-208V 68
342-30-THSS-240V 68
342-30-THSS-480V 68
342-60-TH-208V 68
342-60-TH-240V 68
342-60-TH-480V 68
342-60-THSS-208V 68
342-60-THSS-240V 68
342-60-THSS-480V 68
342-90-TH-208V 68
342-90-TH-240V 68
342-90-TH-480V 68
342-90-THSS-208V 68
342-90-THSS-240V 68
342-90-THSS-480V 68
342-A30-TH-208V 68
342-A30-TH-240V 68
342-A30-TH-480V 68
342-A30-THSS-208V 68
342-A30-THSS-240V 68
342-A30-THSS-480V 68
342-A60-TH-208V 68
342-A60-TH-240V 68
342-A60-TH-480V 68
342-A60-THSS-208V 68
342-A60-THSS-240V 68
342-A60-THSS-480V 68
343-30-TH-208V 69
343-30-TH-240V 69
343-30-TH-480V 69
343-30-THSS-208V 69
343-30-THSS-240V 69
343-30-THSS-480V 69
343-60-TH-208V 69
343-60-TH-240V 69
343-60-TH-480V 69
343-60-THSS-208V 69
Page
1
INDEX
Page 99
Product Index Listing
Model
343-60-THSS-240V 69
343-60-THSS-480V 69
343-90-TH-208V 69
2
343-90-TH-240V 69
343-90-TH-480V 69
343-90-THSS-208V 69
343-90-THSS-240V 69
343-90-THSS-480V 69
INDEX
3900AC 51
3900ACC 51
3900-CS 51
3900-CSC 51
3900DS 51
3900DSC 51
3900-ICS 51
3900-ICSC 51
3900-OCS 51
3900-OCSC 51
3900REC 51
3900RECC 51
3900T1 51
3900T1C 51
3900T2 51
3900T2C 51
3900WW120 51
3900WW28 51
3900WW36 51
3900WW48 51
3900WW60 51
3900WW72 51
3900WW96 51
39BS120 51
39BS120C 51
39BS28 51
39BS28C 51
39BS36 51
39BS36C 51
39BS48 51
39BS48C 51
39BS60 51
39BS60C 51
39BS72 51
39BS72C 51
39BS96 51
39BS96C 51
4300EX16 47
4300EX16W 47
4300EX16W 48
4300EX32 47
4300EX32W 47
4300EX32W 48
Page
Model
4300EX8 47
4300EX8W 47
4300EX8W 48
4300P 47
4300PB 40
4300PW 47
4300PW 48
43T 47
43T 48
43T2 47
4400EX16 40
4400EX32 40
4400EX8 40
462-30-TH-480V 68
462-30-THSS-480V 68
462-60-TH-480V 68
462-60-THSS-480V 68
462-90-TH-480V 68
462-90-THSS-480V 68
462-A30-TH-480V 68
462-A30-THSS-480V 68
462-A60-TH-480V 68
462-A60-THSS-480V 68
463-30-TH-480V 69
463-30-THSS-480V 69
463-60-TH-480V 69
463-60-THSS-480V 69
463-90-TH-480V 69
463-90-THSS-480V 69
483 TM 79
48T2 48
4PD10-1018-3 97
4PD15-1218-2-3 97
4PD15-1218-3 97
4PD20-1220-3 97
4PD25-1620-3 97
4PD30-1624-2-3 97
4PD30-1624-3-3 97
4PD35-1624-3 97
4PD40-1624-3 97
4PD50-1630-3 97
4PD5-812-3 97
630-05129 73
630-10209 73
630-10249 73
630-16209 73
630-16249 73
630-16279 73
630-16489 73
630-25209 73
630-25249 73
Page
Model
630-25279 73
630-25489 73
630-36489 73
630-38579 73
631-16249 73
631-25489 73
631-25609 73
631-38579 73
632-1620 69
632-1620 73
632-1624 69
632-1624 73
632-2548 69
632-2548 73
6333D052033B30D0F 25
6333D052433B30D0F 25
6333D053834B30D0F1 25
6333D054134B30D0F1 25
6333D054833B30D0F 25
6333D103834B30D0F1 25
6333D104134B30D0F1 25
6346D102033B30D0F 25
6346D102433B30D0F 25
6346D104833B30D0F 25
641-35611 73
641-35621 73
641-35631 73
641-35641 73
641-35661 73
641-36051 73
641-36061 73
641-36071 73
641-37211 73
641-50011 73
641-50021 73
641-70001 73
641-70011 73
641-70021 73
641-70031 73
641-70041 73
641-70241 73
641-70251 73
641-70261 73
641-70271 73
641-70281 73
641-70321 73
671-3454 73
671-3492 73
671-3784 73
671-3785 73
671-3786 73
Page
Model
671-5018 73
671-5056 73
671-5057 73
671-5058 73
671-5059 73
671-5060 73
671-5061 73
7PD2-812-1 97
7PD3.5-812-1 97
7PD5-812-1 97
8PD10-1018-3 97
8PD15-1218-2-3 97
8PD15-1218-3 97
8PD20-1220-3 97
8PD25-1620-3 97
8PD30-1624-2-3 97
8PD30-1624-3 97
8PD35-1624-3 97
8PD40-1624-3 97
8PD45-1630-3 97
8PD50-1630-3 97
8PD5-812-3 97
9100EC 56
9100IC 56
9100OC 56
91BS012 56
91BS024 56
91BS036 56
91BS048 56
91BS060 56
91BS072 56
91BS084 56
91BS096 56
91BS108 56
91BS120 56
9300EC 58
9300IC 58
9300OC 58
93BS012 58
93BS024 58
93BS036 58
93BS048 58
93BS060 58
93BS072 58
93BS084 58
93BS096 58
93BS108 58
93BS120 58
A1600 22
A1601 22
A5105 15
Page
Page 100
Product Index Listing
Model
A51100 18
A5120 15
A5150 15
A5175 18
A5520/UHB 10
A6176 17
A6176 86
AD5120 15
AD5120 15
AD5150 15
AD5150 15
AD5175 15
AET5DWS 83
AET5SWS 83
AF3401-24 36
AF3402-24 36
AF3403-24 36
AG3401-24 36
AG3402-24 36
AG3403-24 36
AH3401-24 36
AH3402-24 36
AH3403-24 36
APS-3C 74
ASHDB ECL 63
ASHDB ECR 63
ASHDB IC 63
ASHDB OC 63
ASHDB SP 63
ASHDB WT 63
ASHDB-10 63
ASHDB-2 63
ASHDB-3 63
ASHDB-4 63
ASHDB-5 63
ASHDB-6 63
ASHDB-7 63
ASHDB-8 63
ASHDB-8/20-1000BS 63
ASHDB-8/20-100BS 63
ASHDB-8/20-200BS 63
ASHDB-8/20-300BS 63
ASHDB-8/20-400BS 63
ASHDB-8/20-500BS 63
ASHDB-8/20-600BS 63
ASHDB-8/20-700BS 63
ASHDB-8/20-800BS 63
ASHDB-8/20-900BS 63
ASHDB-9 63
B5105 15
B51100 18
Page
Model
B5150 15
B5175 18
BBS024A 55
BBS024AW 55
BBS024C 55
BBS028A 55
BBS028AW 55
BBS028C 55
BBS036A 55
BBS036AW 55
BBS036C 55
BBS040A 55
BBS040AW 55
BBS040C 55
BBS048A 55
BBS048AW 55
BBS048C 55
BBS060A 55
BBS060AW 55
BBS060C 55
BBS072A 55
BBS072AW 55
BBS072C 55
BBS084A 55
BBS084AW 55
BBS084C 55
BBS096A 55
BBS096AW 55
BBS096C 55
BBS120A 55
BBS120AW 55
BBS120C 55
BDR115 55
BDR115B 55
BDR115W 55
BOX 3310 40
BOX3310 34
BOX3310 45
CB ECL 63
CB ECR 63
CB IC 63
CB MF 63
CB OC 63
CB SP 63
CB WT 63
CB-10 63
CB-1000BS 63
CB-100BS 63
CB-2 63
CB-200BS 63
CB-3 63
Page
Model
CB-300BS 63
CB-4 63
CB-400BS 63
CB-5 63
CB-500BS 63
CB-6 63
CB-600BS 63
CB-7 63
CB-700BS 63
CB-8 63
CB-800BS 63
CB-9 63
CB-900BS 63
CF36 82
CF48 82
CF60 82
CFHD36 82
CFHD48 82
CFHD60 82
CH-2212-1C 77
CH-6424-1C 77
CHWG-222 69
CHWG-223 69
CHWG-342 69
CHWG-343 69
CHWG-462 69
CHWG-463 69
CIT-1 74
CKTD110 84
CP122 37
CP122i 37
CP123 37
CP123i 37
CP125 37
CP125i 37
CP127 37
CP127i 37
CP2202i 37
CP2203i 37
CP2205i 37
CP2207i 37
CP702 37
CP703 37
CP705 37
CP707 37
CP802 37
CP803 37
CP805 37
CP807 37
CS 55
CSB 55
Page
Model
CSW 55
CTBDB 55
CTBDB 55
CTBDB-TP 55
CTBDW 55
CTBSB 55
CTBSB 55
CTBSB-TP 55
CTBSW 55
CV10012X 38
CV10022Xi 38
CV10027X 38
CV100X 38
CV100Xi 38
CV100YX 38
CV11012X 38
CV11022Xi 38
CV11027X 38
CV110X 38
CV110Xi 38
CV110YX 38
CV12512X 38
CV12522Xi 38
CV12527X 38
CV125X 38
CV125Xi 38
CV125YX 38
CV4512X 38
CV4522Xi 38
CV4527X 38
CV45X 38
CV45Xi 38
CV45YX 38
CV6012X 38
CV6022Xi 38
CV6027X 38
CV60X 38
CV60Xi 38
CV60YX 38
CV7512X 38
CV7522Xi 38
CV7527X 38
CV75X 38
CV75Xi 38
CV75YX 38
CV9012X 38
CV9022Xi 38
CV9027X 38
CV90X 38
CV90Xi 38
CV90YX 38
Page