505 Instruction Manual
505
PHOTO / CONTACT TACHOMETER
Instruction Manual
WARNING
Read instructions before operating:
Be sure these instructions accompany the tool when passed from one user to a new or inex­perienced user. Rotating equipment can cause flying particles
Wear Safety Goggles (User and bystanders).
Flying particles can cause eye injury.
Keep yourself, clothing and test equipment clear of moving parts.
Note: To zero previous readings on all tach
operations, Press and hold the START button then press the desired function button. If a stored value appears, release START button until the display goes off. Then press the START button immediately and a zero reading will be displayed until the unit is used for mea­suring RPM or the START button is released.
2
OPERATION SPECIFICATIONS
Function Range Accuracy
Photo Tach 6 - 30,000 RPM ± 0.1% of FS + 1 digit Contact Tach 6 - 20,000 RPM ± 0.1% of FS + 1 digit Surface Speed 0.9 - 3,046 m/min ± 0.1% of FS + 1 digit
2.0 - 9,990 ft/min ± 0.1% of FS + 1 digit
GENERAL SPECIFICATIONS
Display 5 Digit LCD Operating Temperature: 32°to 122°F
0°to 50°C
Operating Humidity: 80% Max. R.H. Power Supply: AA Alkaline Bat.
(2 each)
7
BATTERY REPLACEMENT
Measurement Procedure:
1. Remove the screw holding the battery compart­ment cover in place on the back of the 505.
2. Slide the cover off of the unit.
3. Remove the 2 each “AA” alkaline batteries and replace with the same type.
4. Replace the cover and screw.
STANDARD ACCESSORIES
Reflective Tape . . . . . . . . . . . . . . . . . . . . . . .A501
Contact RPM Adapter (screw on) . . . . . . . . .A502
RPM Adapter (Cone Type) . . . . . . . . . . . . . .A503
RPM Adapter (Funnel Type) . . . . . . . . . . . . .A504
Surface Speed Test Wheel . . . . . . . . . . . . . .A505
(O.D. 48.7 mm exactly)
Carrying case . . . . . . . . . . . . . . . . . . . . . . . .A915
6
PHOTO TACH OPERATION
Measurement Procedure:
1. Unscrew contact collar from optical end of 505 (if attached).
2. Attach a piece of reflectIive tape on the rotating object to be measured.
3. Depress and hold the START button and then press the Photo button (lower right) on the
505.
4. With the start button depressed, point the optical end at the rotating surface so the relective tape passes the lens every rotation.
5. Read the RPM on the LCD display.
Memory Recall
Note: The memory resets itself once the START button is depressed and stable measurements are displayed for 10 seconds or 12 revolutions (whichever is longer). The values are stored when the START button is released.
1. When you are finished taking measurements, release the START button.
2. Depress the MEMORY button once, the LAST reading will be displayed
3. Press the MEMORY button twice, the MAX reading will be displayed.
4. Press the MEMORY button three times, the MIN reading will be displayed.
Unit will auto power off after 5 seconds.
3
CONTACT TACH OPERATION
Measurement Procedure:
1. Screw the shaft assembly to the optical end of the 505.
2. Insert the cone or concave wheel that more closely matches the end of the component to be measured on the shaft assembly.
3. Press and hold the START button and then press the Contact button (lower left) on the
505.
4. While pressing the START button, hold the wheel against the end of the rotating shaft..
5. Read the RPM on the LCD.
Memory Recall
Note: The memory resets itself once the START button is depressed and stable measurements are displayed for 10 seconds or 12 revolutions (whichever is longer). The values are stored when the START button is released.
1. When you are finished taking measurements, release the START button.
2. Depress the MEMORY button once, the LAST reading will be displayed
3. Press the MEMORY button twice, the MAX reading will be displayed.
4. Press the MEMORY button three times, the MIN reading will be displayed.
Unit will power off after 5 seconds.
4
SURFACE SPEED OPERATION
Measurement Procedure:
1. Screw the shaft assembly to the optical end of the 505.
2. Insert the large wheel to the end of the shaft assembly.
3. Press and hold the START button and then press the ft/min (feet per minute) or m/min (meters per minute) on the 505.
4. While pressing the START button, hold the wheel against the moving surface.
5. Read the speed on the LCD.
Memory Recall
Note: The memory resets itself once the START button is depressed and stable measurements are displayed for 10 seconds or 12 revolutions (whichever is longer). The values are stored when the START button is released.
1. When you are finished taking measurements, release the START button.
2. Depress the MEMORY button once, the LAST reading will be displayed
3. Press the MEMORY button twice, the MAX reading will be displayed.
4. Press the MEMORY button three times, the MIN reading will be displayed.
Unit will power off after 5 seconds.