Power requirements……........……………………………………..........120V, 60 Hz, 2.2 Amps.
PSI Rating...…...……...……………………………………………………………….……..130 psi
Generates 2,000 Cubic Ft. / Minute of Fan Propelled fine mist vapor, cooling
up to 200 sq.ft. (2-gallons/hr – full-on, without cycling)
Fan Motor………………………1-Speed, 120volt, 1/8 HP, sleeve bearing, permanently lubricated, totally enclosed, permanent split capacitor.
Switch……………………………………………….…………….Toggle (Fan Only or Fan & Mist) Blade…..…………………………………………..…..……………………………………Aluminum
Power cord...…...……………………..…….....18’ 18/3 SJT type, with molded plug GFCI Plug
Cooler Size……………………………………………….………………...…...……......10 Gallons
Cooler & Fan Head Dimensions………..………..………..………..……..17” Wide X 20” Long
POWER MISTER
MODEL: PM18-S
PART NO.:
SPECIFICATIONS
08554702
ELECTRICAL SHOCK
HAZARD.
x Serious injury or death
possible.
x Disconnect from electrical
supply before filling, servicing, or moving product.
x Read and understand all
safety information in this manual before using
roduct.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION
1. Check local codes and utility standards. The installation must comply with their rules.
2. Never use during rain, sleet, hail, snow or an other inclement weather conditions.
3. Your cooling unit will run on 120 volt AC, 60 Hz (cycle) only.
4. Do not operate if plug or cord is damaged in any way.
5. Do not step on or roll over power cord with heavy or sharp objects.
6. Do not operate unit unless all parts are securely in place.
7. Remove the plug from the electrical receptacle by pulling on the plug and not on the cord.
8. Test the GFCI safety plug monthly to ensure it is functioning properly.
9. Do not operate near open containers of flammable liquids or gases.
10. Do not place foreign objects through guards into blades.
11. Never wash your unit with garden hose; water may harm motor and pump.
12. If the unit is damaged or it malfunctions, do not continue to operate it. Call TPI customer service department at 1-800-251-0382.
Issue Date: 05-01-03 OIPM P/N 8914 Page 1 of 3
Page 2
SET-UP INSTRUCTIONS
f
p
1. Remove unit from carton making sure to locate water supply line and filter assembly.
6
2. Attach water supply hose with filter assembly to the pump.
3. Fill cooler with clean fresh water and install fan and pump unit on cooler (making sure that the supply hose goes toward the bottom of the cooler).
4. Plug the GFCI safety plug directly into a 120-volt A.C. 60 Hz grounded electrical Power supply.
Note
: Improper voltage will burn out motor
and pump windings and void warranty.
ELECTRICAL SHOCK
HAZARD.
x Serious injury or death
possible.
x Disconnect from
electrical supply before filling, servicing, or moving product.
x Test GFCI per
instructions on this page before using
roduct.
GFCI SAFETY PLUG TEST
The GFCI safety plug provides added safety for using this cooler for indoors or outside environments.
OPERATING INSTRUCTIONS
1. Always make sure the unit is operated on a level surface. The PM-18 unit has built in tip over switch in the pump to remove power from the unit in the event of a 35-degree tilt or more. The PM-24 unit has a temperature sensor to shut off water pump if no water is flowing through pump for cooling.
2. Recommend the use of fresh water for daily operations.
3. Caution do not operate pump without proper water level or with no water unless you are using the fan only option.
4. Check for leaks. If there are any leaks turn off
pump and reinsert tubing or hand tighten the fitting that were leaking.
x Test the GFCI safety plug before each use. x Plug GFCI into a power outlet – the indicator
will show power is available.
x Press the test button – indicator will turn off. x Press reset button before use.
Note: Do Not Use If Above Test Fails.
PROPER MAINTENANCE
Check filter assembly occasionally. Replace i
it becomes clogged.
Clogged nozzles – remove, and place in a
cleaner overnight in a scale and lime­removing product. Flush line for a few seconds then re-install nozzle. Use spare nozzles as required. Note: Hand-tighten nozzles only.
Recommend regular cleaning of unit with an
anti-bacterial agent. This includes the water storage unit or cooler.
Cover the unit when not in use.
Issue Date: 05-01-03 OIPM P/N 8914 Page 2 of 3
Page 3
r
r
r
A
r
f
EXPLODED VIEW AND REPLACEMENT PARTS LIST
ITEM # QTY. P/N DESCRIPTION
1 1 63755-101 FRONT GUARD (PAINTED) 2 1 63756-101 REAR GUARD (PAINTED) 3 1 58-381-001 SUPPORT TUBE ASSEMBLY 4 1 58158-001 MOTOR TOTALLY ENCLOSED 5 1 44115-001 CORDSET 6 1 58299-002 FAN BLADE ASSEMBLY 7 1 44114-001 SWITCH (TOGGLE-WATER PROOF) 8 3 44112-001 TEE (PLASTIC ORIFICE)
9 1 44109-001 TEE (PLASTIC 1/4") 10 4 44108-001 ORIFICE (BRASS) 11 1 44105-001 TUBING (1/4" NYLON) 80" LENGTH 12 2 42502-001 BOLT 1/4" - 20 X 1.25" CARRIAGE 13 2 43884-001 RUBBER BUSHING 14 2 4901 NUT 1/4" - 20 HI-CROWN NYLON 15 1 73047-001 PUMP CASE 16 1 73048-001 PUMP CASE (LID) 17 1 63924-001 COOLER (10 GAL.) 18 2 44108-002 ORIFICE PLUG 19 1 58380-001 PUMP 20 1 44104-001 FILTER
WARRANTY
TPI CORPORATION - P.O. Box 4973
Johnson City, TN 37602-4973
(800) 251-0382435-9201
TPI Corporation Guaranteed Customer Satisfaction Warranty States:
If you are ever dissatisfied with the quality of our workmanship or in the design o function of our equipment, you may return it to us for repair, replacement, or credit at ou discretion. A returned goods number will be issued at the time you contact us. This number is necessary to assure that you get proper credit for your return. Shipping costs for returns are at the expense of the customer unless otherwise negotiated.
We want satisfied Customers and will make every effort to satisfy our customers.
IN CASE OF PRODUCT FAILURE: It shall be the obligation of the owner to furnish to the company the following
1. Model Number and date of manufacture of product involved.
2. Complete description of the problem encountered with product.
SELLER'S LIABILITY
Seller will not be liable for any loss, damage, cost of repair, incidental or consequential damages of any kind, whether based on warranty, contract or negligence, and arising in connection with the sale, use or repair of the Products. Seller's maximum liability shall not in any case exceed the contract price for the Products claimed to be defective o unsuitable.
RETURNED GOODS
Equipment may be accepted for return with in 90 days of shipment, when authorized by us with our return labels. Request necessary permission and special Return
uthorization Tags. Currently listed equipment in new and unused condition, and in factory sealed cartons, may normally be returned for full credit less 25% (minimum charge $20.00) charge for handling, repacking and restocking, and less transportation charges both ways, at net prices prevailing at time of purchase or time of return, whichever is lower. TPI Corporation, however, reserves the right to refuse any return, at our discretion, if TPI Corporation is not responsible for error. All special, custom made o equipment with special finishes, and modified versions of cataloged numbers are not returnable. All returned merchandise is subject to inspection. Unsalvageable and damaged merchandise will be credited at salvage value or less costs of repairs.
DAMAGED GOODS
Minimum charge on replacement will be waived if order is accompanied by copy of proo of claim submitted to carrier. No repair, replacement, or other adjustment by the customer is authorized by us, unless so stated in writing by our Sales Service department.
information:
Issue Date: 05-01-03 OIPM P/N 8914 Page 3 of 3
Loading...