106711
OPERATION– INSTALLATION– PARTS MANUA
www.tpicorp.com
Made in
U.S.A.
Power requirements……........……………………………………..........120V, 60 Hz, 2.2 Amps.
PSI Rating...…...……...……………………………………………………………….……..130 psi
Generates 2,000 Cubic Ft. / Minute of Fan Propelled fine mist vapor, cooling
up to 200 sq.ft. (2-gallons/hr – full-on, without cycling)
Fan Motor………………………1-Speed, 120volt, 1/8 HP, sleeve bearing, permanently
lubricated, totally enclosed, permanent split capacitor.
Switch……………………………………………….…………….Toggle (Fan Only or Fan & Mist)
Blade…..…………………………………………..…..……………………………………Aluminum
Power cord...…...……………………..…….....18’ 18/3 SJT type, with molded plug GFCI Plug
Cooler Size……………………………………………….………………...…...……......10 Gallons
Cooler & Fan Head Dimensions………..………..………..………..……..17” Wide X 20” Long
POWER MISTER
MODEL: PM18-S
PART NO.:
SPECIFICATIONS
08554702
ELECTRICAL SHOCK
HAZARD.
x Serious injury or death
possible.
x Disconnect from electrical
supply before filling,
servicing, or moving
product.
x Read and understand all
safety information in this
manual before using
roduct.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION
1. Check local codes and utility standards. The
installation must comply with their rules.
2. Never use during rain, sleet, hail, snow or an
other inclement weather conditions.
3. Your cooling unit will run on 120 volt AC, 60
Hz (cycle) only.
4. Do not operate if plug or cord is damaged in
any way.
5. Do not step on or roll over power cord with
heavy or sharp objects.
6. Do not operate unit unless all parts are
securely in place.
7. Remove the plug from the electrical
receptacle by pulling on the plug and not on
the cord.
8. Test the GFCI safety plug monthly to ensure
it is functioning properly.
9. Do not operate near open containers of
flammable liquids or gases.
10. Do not place foreign objects through guards
into blades.
11. Never wash your unit with garden hose;
water may harm motor and pump.
12. If the unit is damaged or it malfunctions, do
not continue to operate it. Call TPI customer
service department at 1-800-251-0382.
Issue Date: 05-01-03 OIPM P/N 8914 Page 1 of 3
SET-UP INSTRUCTIONS
1. Remove unit from carton making sure
to locate water supply line and filter
assembly.
6
2. Attach water supply hose with filter
assembly to the pump.
3. Fill cooler with clean fresh water and
install fan and pump unit on cooler
(making sure that the supply hose goes
toward the bottom of the cooler).
4. Plug the GFCI safety plug directly into
a 120-volt A.C. 60 Hz grounded
electrical Power supply.
Note
: Improper voltage will burn out motor
and pump windings and void warranty.
ELECTRICAL SHOCK
HAZARD.
x Serious injury or death
possible.
x Disconnect from
electrical supply before
filling, servicing, or
moving product.
x Test GFCI per
instructions on this
page before using
roduct.
GFCI SAFETY PLUG TEST
The GFCI safety plug provides added safety for using
this cooler for indoors or outside environments.
OPERATING INSTRUCTIONS
1. Always make sure the unit is operated on a
level surface. The PM-18 unit has built in tip
over switch in the pump to remove power
from the unit in the event of a 35-degree tilt
or more. The PM-24 unit has a temperature
sensor to shut off water pump if no water is
flowing through pump for cooling.
2. Recommend the use of fresh water for daily
operations.
3. Caution do not operate pump without proper
water level or with no water unless you are
using the fan only option.
4. Check for leaks. If there are any leaks turn off
pump and reinsert tubing or hand tighten the
fitting that were leaking.
x Test the GFCI safety plug before each use.
x Plug GFCI into a power outlet – the indicator
will show power is available.
x Press the test button – indicator will turn off.
x Press reset button before use.
Note: Do Not Use If Above Test Fails.
PROPER MAINTENANCE
Check filter assembly occasionally. Replace i
it becomes clogged.
Clogged nozzles – remove, and place in a
cleaner overnight in a scale and limeremoving product. Flush line for a few
seconds then re-install nozzle. Use spare
nozzles as required. Note: Hand-tighten
nozzles only.
Recommend regular cleaning of unit with an
anti-bacterial agent. This includes the water
storage unit or cooler.
Cover the unit when not in use.
Issue Date: 05-01-03 OIPM P/N 8914 Page 2 of 3