TPI PGM100 Instruction Manual

PGM100
Carbon Monoxide
Single Gas Monitor
The Value Leader
TM
www.tpi-thevalueleader.com
Agency Listings................................................... 1
Safety Information................................................ 2
General Description & Physical Specifications.............. 3
Product Features..................................................4
Sensor Specifications, Alarm Settings, Bump Testing..... 5
Adjust Date / Time................................................6
Alarm Adjustment.................................................7
Calibration......................................................... 8
Operation and Use................................................9-10
Warranty and Repair Policy..................................... 11
TPI PGM100 SINGLE GAS MONITOR INSTRUCTION MANUAL For use with Carbon Monoxide (CO)
Read and understand instructions before use.
Warning: To prevent ignition of flammable or combustible atmos-
pheres, disconnect power before servicing.
Warning: To reduce the risk of ignition of a flammable atmosphere, bat-
teries must only be changed in an area known to be nonflammable.
Avertissement: Pour reduire le risque d’fallumage d’fune atmosphere
inflammable, des batteries doivent seulement etre changees dans un
secteur connu pour etre inflammables.
IP65
EMC Directive (2004/108/EC) EN 61000-4-2:1995, EN 61000-4-3:2002, EN 55011:2007
Class 1, Groups A, B, C & D Exia, Temp code: T4
1
Safety Information
1. IMPORTANT:
Read and understand this manual prior to use.
2. IMPORTANT:
Oxygen instruments will show high readings for up to 30 minutes if taken from warm air to cold temperatures and vice-versa. For best results let them "soak" in the ambient conditions prior to use.
3. WARNING: Substitution of components may impair intrinsic Safety.
4. WARNING: This instrument contains a lithium battery which may
leak or explode if improperly used. DO NOT DISPOSE OF IN A FIRE.
5. WARNING: Only service in an area known to be free of combustible
gases.
6. WARNING: Instruments are not certified intrinsically safe in environ-
ments above 21% oxygen.
7. WARNING: To verify operation prior to each day's use a function test
(bump test) should be performed. If the instrument does not pass this test, full calibration should be performed.
8. WARNING: Keep all openings free from dirt, debris and foreign
objects.
9. WARNING: Do not use a damaged or improperly operating instru-
ment. Contact a service representative immediately.
ONL
Y zero instrument in a gas free environment
SEULEMENT l'instrument zéro dans un gas libèrent l'environnenment.
WARNING: To maintain intrinsic safety, service must be performed by fac­tory authorized technicians with approved replacement parts only.
AVERTISSEMENT:
Pour maintenir la sûreté intrinsèque, service doit être exécuté par les techniciens autorisés par usine avec les pièces de rechange approuvées seulement
2
General Description
The TPI PGM100 is an exceptionally rugged personal gas monitor. The PGM100 is available in single gas configurations only. Preset alarms pro­vide visual, audible and vibration alerts for low and high alarm conditions. Built-in "Time Weighted Average" (TWA) and "Short Term Exposure Limit" (STEL) alarms provide even greater margin of safety for the user. A cus­tom display provides the user with easy to view information including gas concentration, time remaining in months to sensor replacement, battery low alert and activation of calibration process. (See Figure 1)
FUNCTION INDICATORS
Battery Low
Operation Time Remaining (months)
Calibration
High/Low Alarm Set Points:
Factory preset to OSHA requirements
TWA/STEL Alarms: Preset to OSHA limits
Other alarm settings available
Data logging: Up to 100 alarm events
Continuous "ON" Option
PHYSICAL SPECIFICATIONS
Operational Temp: -4 to 122° F (-20 to 50° C)
Humidity: 15-90% RH (Non-condensing)
Duty Cycle: Continuous
Response Time: T90 < 30 seconds
Alarms: Sound: 90 Db @ 12" (30cm)
Sight: Display Alerts 270° viewable LEDs Touch: Vibration
Power Source: 3.6V Lithium Battery
Size: 3.81" x 2.31" x 0.8" (9.67 x 5.87 x 2 cm)
Weight: 3.6 oz. (105 g)
Battery Life: 2+ Years
Sensor: Electrochemical
Construction: Environmental resistance IP65
Impact resistant rubberized housing Durable belt clip
3
Figure 1: Custom Display
Loading...