TPI 775 User Manual

775
Combination Carbon Monoxide/Combustible
Gas Detector
1
Contents
General Specifications
Sensor Specifications
Front View
Back View
Standard Accessories
Optional Accessories
General Description
Turning On
Operating Instructions
o General o Combustion Gas Leak Detection
o Carbon Monoxide Detection
Trouble Shooting Guide
Guarantee
LCD & LED Mode
• Tracker Mode
2
General Specifications
Dimensions
Goose Neck Length 16’’
Battery
Power Consumption
Sensor Life CO Sensor
Pressure Range 80 ~ 120kPa
Alarms Visual/Audible
Response Time CO
Leak Instantaneous
Operating Temperature
Sensor Specifications
Type Resolution Range Accuracy
Leak <50ppm 0~50,000ppm ±10%
CO 1ppm 0~2000ppm
240mm X 74mm X
55mm
1.5V Alkaline battery C size X 2
About 400mW in
typical use.
0°C ~ 50°C
Months until 80
% original signal
(24 month
warranted)
90% of reading
in 30 seconds
±5ppm or 5%
whichever is
greater
3
Front View
Back View
4
Standard Accessories
Instruction Manual Soft Pouch
Optional Accessories
Earphones
General Description
The 775 is a state-of-the-art Carbon Monoxide and Combustible Gas Leak detector. It is the first of its kind to combine both de­tection technologies into one easy to use hand-held affordable instrument.
5
Turning On.
Press the On/Menu button and the instrument will start its set up procedure as follows:-
NOTE-Should the battery life indicator LED change to RED and the ‘bat’ symbol be displayed then batteries are flat and need replac­ing.
Software Version
CO and Combustible Gas initialisation period. 25 second countdown.
6
Automatically Zeroes sensors to the air/environment you are in.
NOTE- Always turn instrument on in clean air
.
Automatically tests the Combustible Gas leak sensor
The instrument is now ready for use and the following screen will be displayed:-
7
NOTE-Should an error occur at any point of the set up procedure please refer to the trouble shooting guide for assistance.
Operating Instructions
General
The backlight can be toggled on and off by pressing the N/▼/ backlight button.
Although the instrument performs an automatic zero during the start up procedure a manual zero can be performed by pressing and holding down the Y/▲/ZERO button until the following screen is displayed:-
NOTE-Manual Re-Zero should only be performed in a clean air environment.
To turn the instrument OFF press and hold down the ON/MENU but­ton till the instrument beeps.
8
Combustible Gas Leak Detection
LCD & LED Indication Mode The presence of Combustible Gas will be shown as follows:-
Amount of
Gas Present
<100ppm 0 None None
>100ppm <500ppm 1 1 None
>500ppm <1000ppm 2 1+2 None
>1000ppm <1500ppm 3 1,2+3 None
>1500ppm <2000ppm 4 1,2,3+4 None
>2000ppm <2500ppm 5 2,3+4 1
>2500ppm <3000ppm 6 3+4 1+2
>3000ppm <4500ppm 7 4 1,2+3
LCD Level
Indicator
Indicator LEDs Lit
Green
Red
>4500ppm 8 None 1,2,3+4
An audible tone can be heard by turning the thumb wheel until it clicks to the on position.
9
Tracker Mode The 775 can also be used to Track/Trace a combustible gas leak by using the following method:-
1. Adjust the TICK ADJUST by moving the thumb wheel in
2. Approach the suspected leak area with the combustible
3. Repeat step 2 until leak is found.
4. If the tick stops, the concentration level has decreased.
an anti-clockwise direction until a uniform ticking sound is heard.
leak sensor until the tick begins to increase. When the tick increases DO NOT move the sensor from the area but re­adjust the TICK ADJUST by moving the thumb wheel back in a clockwise direction till the slower uniform tick­ing sound is heard again.
Move back in the opposite direction to find the leak again.
10
Carbon Monoxide Detection
The following information can be accessed for the purpose of am­bient Carbon Monoxide monitoring by pressing the ON/MENU but­ton. Each press of the ON/MENU button will move you onto the next screen as follows:
Record Maximum Readings
Displays the maximum recorded Carbon Monoxide value since switch on.
The recorded Maximum CO level can be zeroed by pressing the Y/ /ZERO button for 5 seconds.
Elapsed Time
Displays, in Hours and Minutes, the elapsed time since switch on.
11
Alarm Warning Level
Displays the current value that the personal audible and visual alarm is set at. Alarm is factory set at 30ppm CO.
The Alarm level can be adjusted by pressing the Y/▲/ZERO and N/ /backlight buttons.
Audible Alarm
Displays whether the Audible Alarm is switched on or off.
The Audible alarm can be toggled on and off by pressing the Y/▲/ ZERO and N/▼/backlight buttons.
NOTE- even though the audible alarm is switched off the visual alarm (RED LED will flash and ‘Warning’ on the LCD) will remain on.
12
**Factory use only**
Press ON/MENU button to return to Normal Operating Mode.
13
Trouble Shooting Guide
Problem Probable Cause Possible Remedy
Instrument won’t turn on ‘SEnS Err’ dis­played on Screen
CO error is dis­played
Flat batteries Check and replace
batteries Faulty Combustible Gas Sensor
Faulty CO sensor Return Instrument
Combustible Gas
Sensor needs re-
plaing
to supplier
14
Guarantee
Your 775 is guaranteed free from defects in materials and work­manship for 3 Years from the date of purchase. The Carbon Mon­oxide sensor is only guaranteed for 2 years.
Covered : - Repair parts and labour; or replacement of the product at the option of your supplier. Normal transportation charges to the purchaser are also covered.
Not covered : - Damage to the product which are the result of abuse, improper use or maintenance are not covered. Any other expenses, consequential damages, incidental expenses including damages to property are not covered. Transportation expenses to the customer are not covered.
To obtain warranty performance: - Include with the product your name, address, phone number, written description of the problem and proof of purchase date. Carefully package and return to your supplier.
This guarantee does not affect your statuary rights.
15
Visit TPI, The Value Leadertm at:
www.tpi-thevalueleader.com
Test Products International, Inc. Headquarters: 9615 SW Allen Blvd. Beaverton, OR 97005 USA 503-520-9197 • Fax: 503-520-1225 e-mail: info@tpi-thevalueleader.com
16
Test Products International UK Ltd. Longley House, East Park Crawley, West Sussex RH10 6AP England Tel: +44 (0)1293 561212 Fax: +44 (0)1293 813465 e-mail: info@tpi-uk.com
Loading...