
750a
Refrigerant Leak Detector
The Value Leader
TM
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com

Contents
• Specifications
• Product Features
• Replacement parts and accessories
• General Description
• Operating Instructions
• Battery Replacement
• Sensor Replacement
• Warranty
Specifications
Power Supply: 2 "C" Alkaline Batteries
Sensor: Conductive Polymer
Ionization (CPI)
Sensitivity: Selectable to 0.3 oz/yr
134a
Warm up: Approx 3 seconds
Response time: Instantaneous
Duty Cycle: Continuous
Battery Life: Approx. 30 hrs.
Size: 3.0" x 9.5" x 1.75"
(77 x 240 x 47) mm
Weight: 1.1 lbs (500g)
Probe Length: 16"
Standard Accessories
Sensor: A712
Instruction Manual: 750a Instruction Manual
Soft Pouch A700
Optional Accessories
Soft Case w/strap A755
Earphone A710
Test vial A713
General Description
The TPI 750a is a state-of-the-art refrigerant
leak detector capable of detecting all halogen
based gases. Selectable sensitivity combined
with an adjustable tick rate will allow any
service professional to pinpoint those tough
to find leaks even in contaminated
environments.
Operating Instructions:
1. Turn the unit on in an uncontaminated
2. The GREEN ready light will illuminate if there is
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com

Standard Accessories
Sensor: A712
Instruction Manual: 750a Instruction Manual
Soft Pouch A700
Optional Accessories
Soft Case w/strap A755
Earphone A710
Test vial A713
General Description
The TPI 750a is a state-of-the-art refrigerant
leak detector capable of detecting all halogen
based gases. Selectable sensitivity combined
with an adjustable tick rate will allow any
service professional to pinpoint those tough
to find leaks even in contaminated
environments.
Operating Instructions:
1. Turn the unit on in an uncontaminated
environment (clean air away from the system in
question) by moving the switch from the
OFF position to the LO position.
2. The GREEN ready light will illuminate if there is
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com

ample battery power. The RED LED may
flicker and the tick may sound during the
warm-up. To silence the tick, rotate the thumb
wheel fully counterclockwise.
3. Adjust the TICK ADJUST by rotating the thumb
wheel in a clockwise direction until a uniform
ticking sound is heard. The RED light will flash
at the same time the tick sounds.
4. Approach suspected leak areas with the sensor
until the tick begins to increase. When the tick
increases, do not move the sensor from the area,
rotate the TICK ADJUST slightly counterclockwise to slow the ticking and continue to
approach the suspected leak area with the sensor. Continue to slow the tick until the location
of the leak is found. If the tick stops, the concentration level has decreased. Movebackin the
opposited direction to find the leak again.
5. To find very small leaks use the same procedure
as listed in paragraph 4, but use the HI mode.
6. If the GREEN LED changes to orange color,
change the batteries.
7. An earphone can be plugged into the earphone
jack when using the instrument in noisy
environments.
8. If the tick is erratic, check the sensor for tightness and cleanliness. Cleaning the sensor with
9. If the instrument does not perform, replace the
Battery Replacement
1. Remove the battery compartment door from the
2. Remove the batteries and replace by sliding the
3. Replace the battery door by sliding the door into
4. For best performance use a quality alkaline bat-
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com

alcohol is permitted as long as the instrument is
turned off.
Warning: Turn unit off before cleaning or
replacing the sensor. Failure to do so may
result in a mild electrical shock.
9. If the instrument does not perform, replace the
sensor. Sensor replacement is recommended
annually.
Battery Replacement
1. Remove the battery compartment door from the
bottom of the handle by sliding the door away
from the front side of the instrument.
2. Remove the batteries and replace by sliding the
negative (-) end of the batteries in first.
3. Replace the battery door by sliding the door into
the slots provided in the handle and allow it to
snap into place.
4. For best performance use a quality alkaline battery.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com

Sensor Replacement
Replace the sensor when:
• The RED light remains illuminated at all times.
• The tick is erratic.
• There is reduced sensitivity.
To replace the sensor:
1. Turn the unit off.
2. Remove the old sensor by unscrewing in a counterclockwise direction.
3. Install the new sensor by screwing in a clockwise direction until finger tight.
4. Do not change the sensor in a hazardous environment
Warning: Turn unit off before cleaning or
replacing the sensor. Failure to do so may
result in a mild electrical shock.
Warranty and repair/exchange policy
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com

Warranty and repair/exchange policy
Your TPI 750a is warranted to be free from
defects in materials and workmanship for a period of one year after purchase (excluding sensor,
calibration and batteries). If within the warranty
period your instrument should become inoperative from such defects, the unit will be repaired
or replaced at our option. This warranty covers
normal use and does not cover damage which
results from alteration, tampering, accident,
misuse, abuse, neglect or improper maintenance. A purchase receipt or other proof of
original date of purchase will be required before
warranty performance will be rendered.
Instruments out of warranty will be repaired for a
service charge. Return the unit postpaid and
insured to:
Test Products International, Inc.
9615 SW Allen Blvd.
Beaverton OR 97005
(503) 520 9197
This warranty gives you specific legal rights and
you may also have other right which vary from
state to state.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com

Copyright © 2001, Test Products International, Inc
The Value Leader
TM
750a Instruction Manual
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com