Thank you for purchasing TPI products. The 360 series
thermometers are easy to use and built to last. They are
backed by a 3 year limited warranty. Please remember to
complete and return your product warranty registration
card.
2.Product Description
The ergonomically designed 360 series hand-held thermometers are waterproof and offer high accuracy and
reliability.
3
3.EC Declaration of Conformity
This is to certify that TPI 360 series thermometers conform to the protection requirements of the council directive 89/336/EEC, in the approximation of laws of the
member states relating to Electromagnetic compatibility
and 73/23/EEC. The Low Voltage Directive by application
of the following standards:
EN 50081-11992 Emissions Standard
EN 50082-11992 Immunity Standard
EN 61010-11993 Safety Standard
EN 61010-2-0311995 Safety Standard
EN 61010-2-0321995 Safety Standard
To ensure conformity with these standard, this instrument must be operated in accordance with the instructions and specifications given in this manual.
CAUTION: Even though this instrument complies with
the immunity standards, it’s accuracy can be affected
by strong radio emissions not covered in the above
standards. Sources such as hand-held radio transceivers, radio and TV transmitters, vehicle radios and
cellular phones generate electromagnetic radiation
that could be induced into the test leads of this instrument. Care should be taken to avoid such situations or
alternatively, check to make sure that the instrument is
not being influence by these emissions.
CAUTION: Please follow manufacturers test procedures whenever possible. Do not attempt to measure
unknown voltages or components until a complete
understanding of the circuit is obtained.
4
B. SAFETY CONSIDERATIONS
5
WARNING: Use caution when performing mea-
surements on temperatures above 100ºF.
GENERAL GUIDELINES
ALW
AYS
•Test your thermometer before using it to make sure it is
operating properly.
•Inspect temperature probes before using to make sure
there are no breaks or shorts.
•Double check all connections before testing.
NEVER
•Insert the probe into an electrically charged medium.
•Touch the probe tip or shaft after it has been inserted in
a hot substance.
C. TECHNICAL DATA
1.Features and Benefits
Large LCD Easy to read measurement results
High AccuracyReliable test results.
Water ProofRugged and built to last.
Auto OffAutomatically powers off after
5 minutes of inactivity.
Data LoggingRecord and time stamp results.
(367D Only)
6
2.Product Applications
Perform the following tests and/or measurements with
the 360 series thermometers:
Validate the temperature of incoming food product
prior to accepting deliveries.
Measure food storage temperature.
Verify cooking and storage temperature.
Confirm hot and cold holding cabinet temperatures.
Measure food reheating temperatures.
Monitor frozen food thawing temperature.
7
3.Specifications
Input TypeRange
Thermistor-58ºF to 302ºF (-50ºC to 150ºC)
K-Type Thermocouple-328ºF to 1,112ºF (-200ºC to 600ºC)
T-Type Thermocouple-328ºF to 752ºF (-200ºC to 400ºC)
K-Type ProbeYellow Cord
T-Type ProbeBlue Cord
Thermistor ProbeWhite Cord
Accuracy+/-(0.1% of reading + 0.4ºF (0.2ºC))
Resolution> -100ºC = 0.1ºC, <
100ºC = 1ºC
IP RatingIP 67
Units of Measure ºC / ºF Selectable
Operating Temperature-4ºF to 122ºF (-20ºC to 50ºC)
-100ºC = 0.1ºC, <
100ºC = 1ºC
Battery Type AA (LR6) x 2
Battery Life Up to 14,000 hours
Countdown TimerSelect from 1 second to 24 hours
Real Time ClockYes
Auto Power OffOff after 5 minutes, can be disabled
Over Temperature Alarm Yes
Field Calibration ModeYes
Fast Update ModeYes
Data Logging Mode367D Only
8
D. Measurement Techniques
1. Controls & Functions
LCD Display
Input Connector
On / Off Key
Right Arrow Key
Left Arrow Key
Menu Key
On / Off Key turns the 367 on for use or off
(stand by mode). The clock is displayed when the
instrument is off and the timer and alarm clock
are accessible.
Left Arrow Key is used to select parameters
when the 367 is in “menu” mode. This key is
also used to activate data hold.
Menu Key is used to activate menu mode and
is also used to cycle through various displays.
Right Arrow Key is used to change data,
start/stop the timer and activate alarm mode.
9
2.Clock, Timer, & Alarm
When the 367 is off, the real time clock is displayed and the
coundown timer and alarm clock functions are available. Press the
MENU key to cycle through each of the displays.
Real time clock display
The clock displays in a 24 hour format (hh:mm) and can be set from
the menu mode.
Press the MENU key to cycle to the next display.
10
11
Clock, Timer, & Alarm (continued)
Countdown timer display
One of the three preset countdown timers is displayed.
Pressing the LEFT ARROW key cycles through the timers. The timers
can be set from the menu mode.
Pressing the RIGHT ARROW key activates the timer and the arrows on
the left side of the timer will begin to scroll. Pressing the RIGHT ARROW
key again stops and resets the timer.
When the countdown timer reaches 0, an alarm consisting of 3 short
beeps repeating continuously will activate. Press any key to turn off the
alarm and reset the timer.
Press the MENU key to cycle to the next display.
12
Clock, Timer, & Alarm (continued)
Alarm clock display
The alarm clock set time is displayed.
To set the alarm press the LEFT ARROW key and the minutes digits will
blink. Press the RIGHT ARROW key to set the desired value. Holding the
key down will increase the value rapidly.
Press the LEFT ARROW key to cycle to the hour digits. Press the RIGHT
ARROW key to set the desired value. Holding the key down will increase
the value rapidly.
Press the LEFT ARROW key to exit (no digits blinking) and the alarm is
set.
13
Clock, Timer, & Alarm (continued)
To activate the alarm press the RIGHT ARROW key and an alarm bell will
display next to the time.
To deactivate alarm mode, press the RIGHT ARROW key again.
When the alarm clock set time is reached the alarm will begin to sound.
Press any key to turn off the alarm.
14
3. Performing Measurements
1.Turn the 367 on by pressing the On/Off key. The display will read
“OPEN” if no probe is attached.
MENU mode can be activated to change clock, display, and data
logging (367D only) settings after the 367 has been turned on.
Please see page 22. If no changes are necessary please proceed to
the next step.
2.Attach a temperature probe to the input connector and use the
screw collar to secure the probe to the thermometer.
3T
ouch or insert the probe into the item under test. The temperature
measured at the probe will display on the 367. Press the MENU key
to set the sub display to clock mode. The temperature will be dis-
played in the main display. Please see below.
4.From the temperature / clock display the following functions can be
performed.
Data Hold - Pressing the LEFT ARROW key freezes the display and
“HOLD” will be displayed. Pressing the LEFT ARROW key again returns
the 367 to normal operation.
15
Performing Measurements (continued)
Increased Update Rate - Pressing the RIGHT ARROW key increases the
update rate allowing quickly changing temperatures to be measured. “F”
will blink in the display while this mode is active. Please see below.
To return the update rate to normal press the RIGHT ARROW key. Note:
The update rate will automatically return to normal after 5 minutes.
5.Pressing the menu key will cycle through the clock, alarm clock,
timer, and data logging (367D only) functions.
367D Only - If you do not have a 367D please skip to page 20
6.Press the MENU key repeatedly until the sub display switches to
logger display mode. Please see below
16
Performing Measurements (367D Only)
7.“L” will flash when the 367D is logging. Pressing the RIGHT
ARROW key will activate and deactivate logging. The number to the
right will increase each time a new measurement has been logged.
NOTE: When logging is started all previously logged data will be
overwritten.
8.Pressing the LEFT ARROW key displays the current logging interval
setting (See below). The logging interval can be changed in menu
mode. (See appendix A)
9.Pressing the LEFT ARROW key again will cycle the 367D to the log-
ging reserved display (see below).
Performing Measurements (367D Only)
10. Reserved logging is used to tell the 367D to log at the preset start
and stop times. Pressing the RIGHT ARROW key enables (LrES
yes) or disables (LrES no) reserved logging. The start and stop
times can be checked as shown below.
11. Pressing the LEFT ARROW key displays the current logging start
time (See below). The logging start time can be changed in menu
mode. (See appendix A)
12. Pressing the LEFT ARROW key again displays the current logging
stop time (See below). The logging stop time can be changed in
menu mode. (See appendix A)
17
18
Performing Measurements (367D Only)
13. Press the MENU repeatedly to switch the 367D to store / recall
mode (See below)
14. Press the RIGHT ARROW key to select the location to store the cur-
rently displayed measurement. Allow 1 second for data storage.
15. Pressing the RIGHT ARROW key cycles to the next storage location.
There are 16 (0~15) total storage locations. Any existing data is
overwritten when the storage location is selected.
19
Performing Measurements (367D Only)
16. Pressing the LEFT ARROW key switches the 367D to recall mode
(See below).
17. Pressing the LEFT ARROW key selects the location to recall and dis-
play. Allow 1 second for data retrieval.
20
Performing Measurements (continued)
18.Press the MENU key to cycle the 367 to temperature / timer display
mode. The temperature and one of three preset countdown timers
is displayed. See below.
19.Pressing the LEFT ARROW key cycles through the timers. The
timers can be set from the menu mode. Pressing the RIGHT
ARROW key activates the timer and the arrows on the left side of
the timer will begin to scroll. Pressing the RIGHT ARROW key again
stops and resets the timer.
When the countdown timer reaches 0, an alarm consisting of 3
short beeps repeating continuously will activate. Press any key to
turn off the alarm and reset the timer.
21
Performing Measurements (continued)
20.Pressing the MENU key cycles the sub display to the temperature /
alarm clock display. See below.
To set the alarm press the LEFT ARROW key and the minutes digits
will blink. Press the RIGHT ARROW key to set the desired value.
Holding the key down will increase the value rapidly. Press the LEFT
ARROW key to cycle to the hour digits. Press the RIGHT ARROW
key to set the desired value. Holding the key down will increase the
value rapidly. Press the LEFT ARROW key to exit (no digits blinking)
and the alarm is set.To activate the alarm press the RIGHT ARROW
key and an alarm bell will display next to the time. To deactivate
alarm mode, press the RIGHT ARROW key again. When the alarm
clock set time is reached the alarm will begin to sound. Press any
key to turn off the alarm.
21. Pressing the MENU key cycles the 367 the temperature / clock dis-
play.
22
4. Menu Mode
Setting countdown timers
1.. To activate menu mode, press and hold down the MENU key until
the 367 beeps and “EDIT” is displayed. Pressing the MENU key
repeatedly will cycle through the various menu parameters.
2.Press the menu key and countdown timer 1 will be displayed.
a. Use the LEFT ARROW key to select hour, minute, or seconds and
use the RIGHT ARROW key to set the required time. Holding down
the RIGHT ARROW key will change the value rapidly.
3.When changes are complete, press and hold the MENU key to exit
menu mode and return to normal operation or press the MENU key
to cycle to the next timer.
4. “tr1” will change to “tr2” and timer two can be set by performing
the steps a & b above.
5.“tr2” will change to “tr3” and timer three can be set by performing
steps a & b above. Press and hold the MENU key to exit menu
mode and return to normal operation or press the MENU key to
cycle to the next function.
Menu Mode (continued)
Setting the clock
1. To activate menu mode, press and hold down the MENU key until
the 367 beeps and “EDIT” is displayed.
2.Press the menu key repeatedly until clock mode is displayed.
a. Use the LEFT ARROW key to select hour, minute, or seconds and
use the RIGHT ARROW key to set the required time. Holding down
the RIGHT ARROW key will change the value rapidly.
3.When changes are complete, press and hold the MENU key to exit
menu mode and return to normal operation or press the MENU key
to cycle to the function.
23
Menu Mode (continued)
Field calibration
1. To activate menu mode, press and hold down the MENU key until
the 367 beeps and “EDIT” is displayed.
2.Press the menu key repeatedly until field calibration mode is dis-
played (see display below). TO USE FIELD CALIBRATION AN ICE
BATH IS REQUIRED.
3.Insert the temperature probe into the ice bath. The measured tem-
perature is displayed. Allow the thermometer to completely stabilize
(approximately 5 minutes) and then press the LEFT ARROW key.
4.Calibration is complete.
24
25
Menu Mode (continued)
Auto power off
The auto power off function conserves battery life by turning the
367 off after 5 minutes of inactivity. To disable or enable this func-
tion perform the following steps.
If menu mode is active skip to step 2.
1.Press the menu key repeatedly until auto power off mode is dis-
played (see display below).
2.Press the RIGHT ARROW key to activate (yes) or deactivate (no)
auto power off mode.
26
Menu Mode (continued)
Over/Under temperature alarm
The over/under alarm can be used to alert you when the measured tem-
perature is above or below a set point. This mode is used with the gap
setting. (See next page)
1. To activate menu mode, press and hold down the MENU key until
the 367 beeps and “EDIT” is displayed.
2.Press the menu key repeatedly until over temperature alarm mode
is displayed (see display below).
3.Press the RIGHT ARROW key to activate (Lt-yes) or deactivate (Lt-
no) the over temperature alarm.
4.To increase the alarm point press the LEFT ARROW key until Lt-uP
is displayed. Press the RIGHT ARROW key to increase the displayed
value. Holding the RIGHT ARROW key down increases the display
rapidly.
5.To decrease the alarm point press the LEFT ARROW key until Lt-dn
is displayed. Press the RIGHT ARROW key to decrease the dis-
played value. Holding the RIGHT ARROW key down decreases the
display rapidly. After the desired alarm point is set press the MENU
key to go to the next selection or press and hold the MENU key to
exit menu mode.
27
Menu Mode (continued)
Over/Under temperature alarm gap
The over/under temperature alarm gap lets the 367D know how much
over or under the set point the temperature must be for the alarm to
sound. For example, if the set point is 160ºF and the gap is 4ºF, the alarm
will sound if the temperature goes above 164ºF or under 156ºF.
1. To activate menu mode, press and hold down the MENU key until
the 367 beeps and “EDIT” is displayed.
2.Press the menu key repeatedly until over temperature alarm mode
gap is displayed (see display below).
3.Gap mode sets how far away from the alarm set point the tempera-
ture must be before the alarm sounds.
4.To increase the gap point press the LEFT ARROW key until GAP-uP
is displayed. Press the RIGHT ARROW key to increase the displayed
value. Holding the RIGHT ARROW key down increases the display
rapidly.
5.To decrease the alarm point press the LEFT ARROW key until GAP-
dn is displayed. Press the RIGHT ARROW key to decrease the dis-
played value.Holding the RIGHT ARROW key down decreases the
display rapidly.
6.After the desired gap is set press the MENU key to go to the next
selection or press and hold the MENU key to exit menu mode.
28
Menu Mode (continued)
Unit of measure
If menu mode is active skip to step 2.
1. To activate menu mode, press and hold down the MENU key until
the 367 beeps and “EDIT” is displayed.
2.Press the menu key repeatedly until unit of measurement mode is
displayed (see display below).
3.Press the RIGHT ARROW key to switch between Celsius and
Fahrenheit unit of measurement.
4.After the desired unit of measure is set press the MENU key to go
to the next selection or press and hold the MENU key to exit menu
mode.
29
Menu Mode (continued)
Probe type select
The 367 will automatically detect the type of probe connected. To
manually select the type of probe follow the steps below.
If menu mode is active skip to step 2.
1. To activate menu mode, press and hold down the MENU key until
the 367 beeps and “EDIT” is displayed.
2.Press the menu key repeatedly until probe type selection mode is
displayed (see display below).
3.To manually select the type of probe being used press the LEFT
ARROW key to switch the main display to SEL. Press the RIGHT
ARROW key to select between “K” and “T” type thermocouple input.
4.To return the 367 to auto select press the LEFT ARROW key until
Auto is displayed.
5.After the desired probe type is selected press the MENU key to go
to the next selection or press and hold the MENU key to exit menu
mode.
30
E. Logging Parameters (367D Only)
1. To change the logging interval, press and hold the MENU key down
to activate menu mode until the 367 beeps and “EDIT” is displayed.
2.Press the menu key repeatedly until logger interval mode is dis-
played. See below.
3.To set the interval press the RIGHT ARROW key to set the desired
value in seconds. Holding the key down will increase the value
rapidly. Press the LEFT ARROW key and the minutes digits will
blink. Press the RIGHT ARROW key to set the desired value. Press
the LEFT ARROW key to cycle to the hour digits. Press the RIGHT
ARROW key to set the desired value.
4.After the desired interval is set press the MENU key to go to the
next selection or press and hold the MENU key to exit menu mode.
31
Logging Parameters 367D Only (continued)
1. To change the logging start time, press and hold the MENU key
down to activate menu mode until the 367 beeps and “EDIT” is dis-
played.
2.Press the menu key repeatedly until logger start time mode is dis-
played. See below.
3.To set the start time press the RIGHT ARROW key to set the desired
value in seconds. Holding the key down will increase the value
rapidly. Press the LEFT ARROW key and the minutes digits will
blink. Press the RIGHT ARROW key to set the desired value. Press
the LEFT ARROW key to cycle to the hour digits. Press the RIGHT
ARROW key to set the desired value.
4.After the desired start time is set press the MENU key to go to the
next selection or press and hold the MENU key to exit menu mode.
32
Logging Parameters 367D Only (continued)
1. To change the logging stop time, press and hold the MENU key
down to activate menu mode until the 367 beeps and “EDIT” is dis-
played.
2.Press the menu key repeatedly until logger start time mode is dis-
played. See below.
3.To set the stop time press the RIGHT ARROW key to set the desired
value in seconds. Holding the key down will increase the value
rapidly. Press the LEFT ARROW key and the minutes digits will
blink. Press the RIGHT ARROW key to set the desired value. Press
the LEFT ARROW key to cycle to the hour digits. Press the RIGHT
ARROW key to set the desired value.
4.After the desired stop time is set press the MENU key to go to the
next selection or press and hold the MENU key to exit menu mode.
33
Logging Parameters 367D Only (continued)
1. To enable (reserve) the logging function to begin at the specified
start time, press and hold the MENU key down to activate menu
mode until the 367 beeps and “EDIT” is displayed.
2.Press the menu key repeatedly until logger reserve mode is dis-
played. See below.
3.Pressing the RIGHT ARROW key enables (LrES yes) or disables
(LrES no) reserved logging.
4.After the desired reserved mode is set press the MENU key to go to
the next selection or press and hold the MENU key to exit menu
mode.
34
F. Retrieving Logged Data (367D Only)
1. Install the 367D PC interface software on the computer.
2.Attach the 367D interface dock to the 367D and connect the USB
cable from the dock to the PC.
3.The 367D interface software will automatically detect the 367D and
begin communication.
4. Through the software all data logged can be retrieved.
G. Optional Accessories
Part #Description
A365Belt clip holder
A367USB docking station / belt clip, cable, software (367D only)
GT13LBead type probe (food and non-food applications)
GT19LBead type probe with oven clamp
CT11L Surface temperature measurements
FT11LPenectration / Immersion measurements
This is a partial listing of temperature probes available for the 365.
Please visit www.tpi-thevalueleader.com for additional probes.
H. Troubleshooting and Maintenance
Troubleshooting
Problem
Does not power up•Dead or defective battery
Temperature reads •Very weak battery that will
highnot turn on the low battery
Only reads OPEN•Temperature probe not connected
Probable Causes
•Broken wire from battery
snap to PCB
indicator on the LCD
•Temperature probe defective
Maintenance
1.Battery Replacement: The 367 will display a battery
symbol when the internal 1.5 Volt batteries needs
replacement.
a.Disconnect the temperature probe.
b.Loosen the 4 battery cover screws located on the
back cover.
c.Remove the battery cover.
d.Remove old batteries and replace with new batteries.
Observe the correct polarity.
e.Reassemble the instrument in reverse
order from above.
2.Cleaning your 367:
Use a mild detergent and slightly damp cloth to clean the
surfaces of the 367.