This is to certify that models 352/353/354 conform
to the protection requirements of the council directive
89/336/EEC, in the approximation of laws of the member
states relating to Electromagnetic compatibility by
application of the following standards:
EN 50081-11992 Emissions Standard
EN 50082-11992 Immunity Standard
To ensure conformity with these standards, this
instrument must be operated in accordance with the
instructions and specifications given in this manual.
SAFETY CONSIDERATIONS2
WARNING: Please follow manufacturers test
procedures whenever possible. Make sure probe tip and
shaft are thoroughly cleaned before inserting it into any
food product.
GENERAL GUIDELINES
ALWAYS
• Test the 341/342 before using it to make sure it is operating properly.
• Inspect temperature probes before using to make sure there are no breaks
or shorts.
• Double check all connections before testing.
NEVER
• Insert the probe into an electrically charged medium.
• Touch the probe tip and shaft after it has been inserted in hot material.
TECHNICAL DATA3
Features and Benefits
Water Resistant Operates in any environment.
Auto Power OffInstrument automatically shuts off after 20 minutes of
inactivity.
Specifications
Range with K-Type Thermocouple Probe
RangeAccuracy
-328° to 2462°F±1%, ±4°F
Range with J-Type Thermocouple Probe
RangeAccuracy
-328° to 1832°F±1%, ±4°F
General Specifications
Power Supply9 Volt Battery
Battery Life200 hrs. Typical
Size (HxLxW)40mm x 190mm x 65mm (1.5” x 7.25” x 2.5”)
Weight315g (11.1 oz)
MEASUREMENT TECHNIQUES4
1. Controls and Functions:
Push Buttons
Turns the 341/342 on and off.
C/FSelects Centigrade of Fahrenheit
K/JSelects K or J type thermocouple.
Min/MaxSelects Min or Max reading
RECActivates the Min/Max feature.
1/0.1Selects resolution (341)
T1/T2/∆T Selects probe and differential mode (342)
HOLDFreezes the reading on the LCD
2. Step by Step Procedures
a.Connect the temperature probe to the 341/342.
b.Turn the 341/342 on.
c.Insert the tip of the probe into the substance
being measured.
d.Read the temperature on the LCD, allowing
approximately 30 seconds for the reading to
stabilize.
4’ Disposable K-type w/oven clipGK12M
Heavy duty surfaceCK13M
Heavy duty surface, right angleCK14M
Heavy duty chisel probeFK14M
Heavy duty gas (air) probeGK17M
Soft Carrying CaseA255
MAINTENANCE
1. Battery Replacement: The 341/342 will display battery symbol when the
internal 9 Volt battery needs replacement. Replace battery as follows:
a. Disconnect and remove all temperature probes from 341/342.
b. Loosen the 4 screws from the back of the 341/342.
c. Remove the back cover.
d. Remove old battery and replace it with new battery.
f. Reassemble instrument in reverse order from above.
2. Cleaning your 341/342
Use a mild detergent and slightly damp cloth to clean the surfaces of
341/342.