Toxalert Tox-HCI-ANA User Manual

TOXALERT
HYDROGEN CHLORIDE SENSOR MODEL TOX-HCl/ANA
FEATURES: BENEFITS:
•••• Linear 4-20mA output signal •••• Industry standard signal can be directed to most controllers.
••• Automatic low sensitivity check •••• Reliable operation and monitoring integrity.
••• Power up & calibration delays •••• False alarm avoidance.
••• Convenient diagnostics •••• Simple maintenance.
GENERAL DESCRIPTION:
The Toxalert hydrogen chloride sensor module is desi Toxalert and other standard 4-20 mA loo controllers. The module sources an output current in chloride concentration. Toxalert utilizes h
ydrogen chloride sensors that are electrochemical cells. They are the self­powered, diffusion limited, metal-air batter t
ype. The rate at which atmosphere gases can get to the electrode throu barrier is then solel concentration of Current is the rate of consum in the cell.
Previous electrochemical sensors of this general type have used very thin plastic membranes. This results in handling and stability problems and high temperature and pressure coefficients which limit the usefulness of the device. The Toxalert sensor takes a radically different approach by allowing gas to diffuse into the sensor through a simple capillary. Not only is this extremely robust and stable, but entirely different diffusion laws apply resulting in low temperature and pressure coefficients and the capability to monitor gas as a percent volume.
gned for use in conjunction with
p
proportion to the hydrogen
y
gh a diffusion
y dependent on
gases in the atmosphere.
generated that is proportional to
ption of hydrogen chloride
1 of 2
TOXALERT INTERNATIONAL, Inc., PO Box 159, Mound, MN. 55364 PHONE: (952) 472-4541 • FAX: (952) 472-4960
www.toxalert.com
MODEL TOX-HCl/ANA
SPECIFICATIONS:
•••• Type: Electrochemical cell-diffusion barrier type •••• Operating Temperature : 4° to 122°F
•••• Range: 0 to 20 ppm hydrogen chloride in air -20° to 50°C
•••• Response Time: 100 seconds to 90% indication •••• Relative Humidity: 15 to 90% RH non-
•••• Typical Life: Two years in normal service condensing
•••• Electrical Data:
Input Voltage: 14 – 30 vdc Output Signal: Linear 4 to 20 mA Input Power: 1.4 Watt Signal Output-Trouble: 0 mA Input Current: 40 mA @ 28 vdc Wiring: 3 wire non-isolated Loop Resistance: 800 Ohms
•••• Unit Construction:
Mounting: Conduit ¾” NPT or flexible cable Physical: H: 7.6”, D: 4.6”, W: 4.2” Housing: Explosion proof (Nema 7) Weight: 2.7 pounds
(Div 1, Class 1, Groups C, D)