FOR ARCHITECTS & DESIGNERS
TC54
SERIES D
IMPORTANT
This booklet is intended as a basic specication guide
for architects, designers and builders. Please refer to the
Instruction Manual supplied with the replace for detailed
information regarding installation and operation.
Product installation manuals can also be viewed at:
www.townandcountryreplaces.com
5056.9054-A
Dimensions | Clearances | Venting
TC54.D
280915-12
![](/html/0e/0edd/0edd612f44c016136a072fe7e8bf7de9113f27d29952543af4f4767b47d1f0b6/bg2.png)
62 9/16"
35 5/8"
Fireplace Dimensions
63 7/8"
FRAMING
LINTEL
34 1/8"
54 5/16"
Must allow for minimum 1/2 inch
gap for non-combustibel board
and facing
Examples of Common Locations
See “Minimum Combustible Framing Dimensions”
section on page 6 for precise framing dimensions.
48 1/8" 44 1/2"
34 1/8"
TC54D Cad Drawing
Available at
www.townandcountryreplaces.com
For diagonal installation, corner
of fireplace should maintain
standoff distance of 2” to
combustible framing material.
FOR REFERENCE ONLY. CONSULT MANUAL BEFORE INSTALLATION
280915-12
For diagonal installation, corner
of control box is permitted to
make contact with combustible
framing material.
2
5056.9054-A_TC54D
![](/html/0e/0edd/0edd612f44c016136a072fe7e8bf7de9113f27d29952543af4f4767b47d1f0b6/bg3.png)
Direct Vent Roof Installation
NOTE: A vertically vented TC54
cannot be power-vented.
Minimum total vent height for
propane: 20 feet.
48'
MAX.
40'
20'
Vertical termination cap
dimensions
16 1/2”
9”
Termination cap shown without
vertical vent pipe. For vent terminal
minimum clearances, see Roof Pitch
Table and Vent Terminal Minimum
Clearances Table - both on page 8.
Minimum total vent height for
natural gas: 10 feet.
Minimum 5’ of vertical vent
required before 1st elbow.
FOR REFERENCE ONLY. CONSULT MANUAL BEFORE INSTALLATION
10'
4' MAX.
'
5
3
280915-125056.9054-A_TC54D
![](/html/0e/0edd/0edd612f44c016136a072fe7e8bf7de9113f27d29952543af4f4767b47d1f0b6/bg4.png)
Wall Termination Venting
This unit can be vented horizontally (wall termination) ONLY with an approved High Capacity
Power Vent Kit (TCVT.PVAX2) using TC 8x11 Vent Pipe.
Blower outlets
Power vent
terminal
Finished exterior wall
29 5/8”
16 3/4”
Power vent terminal
19 1/8”
Power vent dimensions
Maximum vent length is 66 ft plus six 90 degree elbow or combination of other elbows equaling 90 degrees.
Minimum vent length is 10 ft plus one 90 degree elbow. The vent can be installed with any combination of
rise and run between the above figures including 3ft below the unit.
The premium Power Vent fan runs quietly outside, at the exterior terminal.
FOR REFERENCE ONLY. CONSULT MANUAL BEFORE INSTALLATION
280915-12
Up to 66 feet of run
plus six 90º elbows
Up to 3 feet below unit
4
Power vent
terminal
TC54D Cad Drawing
Available at
www.townandcountryreplaces.com
5056.9054-A_TC54D