Town & Country Fireplaces TC36 SEE-THRUC SERIES, TC36.CSTE Installation And Operating Instructions Manual

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
WARNING: If the information in these instructions is not followed exactly, a  re or explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other  ammable vapors and liquids in the vicinity of this or any other appliance.
TC36 SEE-THRU INSTALLATION
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier call the  re department.
Installation and service must be performed by a quali ed installer, service agency or the gas supplier.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certi ed kit is used.
This appliance is suitable for installation in a bedroom or bed sitting room
071010-44 TC36_CSTE 5056.42801.C
MODEL
TC36ST
SERIES C MODULAR DIRECT VENT SEE-THRU FIREPLACE
Table of Contents
Caution ...........................................................................................3
Safety .............................................................................................3
Massachusetts Rules and Regulations ...........................................4
Fireplace Dimensions .....................................................................5
Minimum Clearances to Combustible Material ............................... 5
Installation Requirements ...............................................................6
Manufactured (Mobile) Home ......................................................... 6
Window Frame Removal ................................................................. 6
Top Standoffs ..................................................................................7
Locating The Fireplace ...................................................................7
Framing and Finishing .................................................................... 8
TC 36 Steel Stud Framing Kit ....................................................... 10
Hearth Extension .......................................................................... 12
Maestro Control – Plumbing and Electrical...................................13
Gas Supply ................................................................................... 15
Gas Pressure Check ..................................................................... 15
Venting .......................................................................................... 16
Wall Termination Venting .............................................................. 16
Wall Termination Venting Chart .................................................... 19
Roof Termination Venting Chart ................................................... 20
Vent Terminal Clearance ............................................................... 23
Vent Terminal Minimum Clearances .............................................23
Vent Pipe Sealant ......................................................................... 24
Vent Restrictor Adjustment ...........................................................25
Firebox Panels Installation ............................................................26
Finishing Touch Trim Kit Instructions ............................................. 27
Lighting Instructions .....................................................................28
First Fire ........................................................................................28
Maestro Control System ............................................................... 29
Remote Control Initial Setup ......................................................... 29
Maestro Control System - Operation ............................................ 30
APPENDIX
Maintenance ............................................................................. 33
TC36.CSTE Replacement Parts ............................................... 34
Replacement Parts – Maestro Control System ......................... 35
Wiring Diagram ......................................................................... 36
Wall Termination Kit ................................................................37
Wall Shield/Ceiling Firestop Thimble .......................................37
Roof Termination Kit ...............................................................37
Vent Pipe Dimensions ..............................................................38
Vent Offset Chart ...................................................................... 40
Safety Label Location ............................................................... 41
TC36_CSTE 071010-44
2
Caution
FOR YOUR SAFETY - Do not install or operate your Town & Country  replace without
 rst reading and understanding this manual. Any installation or operational deviation from the following instructions voids the Town & Country Fireplaces hazardous.
This appliance and its individual shut off valve must be disconnected from gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
Note: When lit for the  rst time, the appliance will emit a slight odour for a couple of hours. This is due to the curing of paints, sealants and lubricants used in the manufacturing process. This condition is temporary. Open doors and windows to ventilate area. Smoke and fumes caused by the curing process may cause discomfort to some individuals.
Do not use the  replace if any part has been under water. Immediately call a quali ed service technician to inspect the  replace and to replace any part of the control system and any gas control which has been under water.
TM
Warranty and may prove
Safety
Due to high temperatures, this gas appliance should be located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance.
Clothing or other  ammable material should not be placed on or near the appliance.
Any grill, panel or door removed for servicing the unit must be replaced prior to operating. Failure to do so may create a hazardous condition.
Installation and repair should be done by a quali ed service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
It is our policy that no responsibility is assumed by the Company or by any of its employees or representatives for any damages caused by an inoperable, inadequate, or unsafe condition which is the result, either directly or indirectly, of any improper operation or installation procedures.
This appliance must not be connected to a chimney  ue serving a separate solid fuel burning appliance.
TC36_CSTE 071010-44
3
Important Note for the Commonwealth of Massachusetts:
From Massachusetts Rules and Regulations 248 CMR 5.08:
(a) For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential
purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above
 nished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satis ed.
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fuelled equipment, the
installing plumber or gas  tter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the  oor level
where the gas equipment is to be installed, in addition, the installing plumber or gas  tter shall observe that a battery operated or hard-wired carbon
monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas
fuelled equipment. It shall be the responsibility of the property owner to secure the services of quali ed licensed professionals for the installation of
hard-wired carbon monoxide detectors.
a. In the event that the side wall horizontally vented gas fuelled equipment is installed in a crawl space or an attic, the hard-wired carbon monoxide
detector with alarm and battery back-up may be installed on the next adjacent  oor level.
b. In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall have a period of thirty
(30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detec-
tor with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall
comply with NFPA 720 and be ANSI/UL 2034 listed as IAS certi ed.
3. SIGNAGE. A metal or plastic identi cation plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet
above grade directly in line with the exhaust vent terminal for the horizontally vented gas fuelled heating appliance or equipment. The sign shall read, in
print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fuelled equipment shall not approve the installation unless,
upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.089(2)(a) 1
through 4.
(b) EXEMPTIONS. The following equipment is exempt from 248 CMR 5.089(2)(a) 1 through 4.
1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the
Board; and
2. Product Approved side wall horizontal vented gas fuelled equipment installed in a room or structure separate from the dwelling, building or struc-
ture used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side
wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by
the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved
side wall horizontally vented gas fuelled equipment does not provide the parts for venting the fuel gases, but identi es “special venting systems”, the fol-
lowing requirements shall be satis ed by the manufacturer.
1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and
2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed
installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fuelled equipment, all venting instructions, all parts
lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
TC36_CSTE 071010-44
4
Fireplace Dimensions
Fig. #1
CENTER OF FLUE OUTLET
Minimum Clearances to Combustible Material
Fig. #2
COMBUSTIBLE FRAMING AND FINISH WALL ABOVE STANDOFFS
MAY USE COMBUSTIBLE FACING MATERIAL IN THIS AREA
NON-COMBUSTIBLE FINISH MATERIAL SEE FIG #7
STEEL FRAMING
STANDOFFS
NON-COMBUSTIBLE ZONE. DO NOT INSTALL ANY COMBUSTIBLE MATERI­AL, ELECTRICAL WIRING OR GAS PLUMBING IN THIS AREA.
TOP STANDOFFS
MANTEL CLEARANCE
CHART
* MANTEL CLEARANCE
A 9”
Fig. #3
TOP OF LINTEL BAR
FIREPLACE FRONT
CEILING
*
MANTEL
UNIT MAY BE RECESSED UP TO 6” WITH NON-CUMBUSTIBLE MASONRY TYPE MATERIAL
ADJACENT WALL OR MANTEL SUPPORT
B 6”
C 3”
** MANTEL DEPTH
D 12”
E 6 3/4”
F 1 1/2”
Minimum Clearances:
Side standoffs .......................................................0 in. (0 mm)
Back standoffs ...................................................... 0 in. (0 mm)
Top standoffs ........................................................ 0 in. (0 mm)
Bottom of appliance ..............................................0 in. (0 mm)
Adjacent side wall .................................................2 in. (51 mm)
Ceiling to appliance ............................................ 24 in. (610 mm)
*Mantel to appliance .................. ..........See Figure #2
**Maximum Mantel extension .. ..........See Figure #2
Mantel support ......................................................2 in. (51 mm)
Vertical vent pipe ..........................................1 3/4" in. (45 mm)
Horizontal Vent pipe (Top, sides and bottom) 1 3/4" in. (45 mm)
TC36_CSTE 071010-44
5
Fig. #4
Fig. #5
Installation Requirements
The Town & Country Fireplace installation and venting must conform to the current CAN/CGA-B149 installation code (in Canada) or the current National Fuel Gas Code, ANSI Z223.1 (in the USA), and approved per local codes. Only quali ed (licensed or trained) personnel should install this product.
In the state of Massachusetts, only a licensed Plumber and Gas Fitter may install this product.
Manufactured (Mobile) Home
In some jurisdictions, the Town & Country Fireplace may be installed in Manufactured Homes after the " rst sale". Consult local codes for approval. The  replace must be fastened in place.
Install in accordance with the current standard Mobile Homes, CAN/CSA Z240 MH (in CANADA), and the Manufacturer's Home Construction and Safety Standard, Title 24 CFR, Part 3280 or the current Standard for Fire Safety Criteria for Manufactured Home Installa­tions, Sites and Communities ANSI/NFPA 501A (in the USA).
Window Frame Removal
LATCH HANDLE
Warning: Turn off the  replace, and allow ample time for the unit to cool before proceeding.
Caution: The ceramic glass is very fragile, and should be handled with care.
The window frame is held in place by two spring-loaded latches that are operated by a one-piece latch handle.
1. Remove the TC Finishing Touch Trim Kit from the window frame. (If installed)
2. Using a screwdriver or other similar object, push against the notch in the top of the latch and grab the bottom of the latch handle as it protrudes. Lift handle until latch hook disengages. Repeat for other side while holding glass so it does not tip out.
3. Tilt the top of the window frame out to clear the top edge of the unit. Grasp the sides of the frame and lift up and out to disengage from its bottom track.
4. Place the window frame in a safe place to avoid damage.
5. Re-assemble in reverse order. Latch handle should snap into place and be  ush with
window frame when engaged correctly.
TIP: To ensure glass is properly latched, grasp the top left and
right sides of the glass frame, under moderate pressure it should pull forward and return to original position evenly on both sides.
6. Reinstall Trim Kit if required.
TC36_CSTE 071010-44
6
Top Standoffs
The top standoffs are shipped loose inside the  replace and must be installed on top of the  replace as shown in Fig #6. Do this once the  replace is on site and in position.
Locating The Fireplace
Fig. #6
TOP STANDOFFS
In planning the installation for the  replace, it is necessary to determine where the unit is to be installed, location of vent system and where gas supply piping may be plumbed. Various installations are possible, such as, into an existing wall, a corner, a built-in wall or a wall projection (Fig #7). Due to high temperatures, do not locate this  replace in areas of high traffic or near furniture or draperies.
The minimum clearances from the  replace to combustible surfaces must be adhered to and are shown in Fig #2 and Fig #3.
Fig. #7
EXAMPLES OF COMMON LOCATIONS SEE FIG #11 FOR DIMENSIONS
TC36_CSTE 071010-44
7
Framing and Finishing
Note: The  replace should be in place and venting installed before framing in or building an enclosure around the unit.
The Town & Country  replace must be framed in as described below or totally en­closed with non-combustible material, such as facing brick.
Determine the total thickness of facing material to be used. A thickness of 3/4" will allow the  nishing surface to be  ush with the front of the unit. If preferred, additional masonry type non-combustible material can be installed above and to the sides up to 6 inches proud of the appliance.
The  nishing material must not interfere with glass frame access.
Two Steel Stud Framing Kits are supplied with the  replace and must be used unless the  replace is totally enclosed with non-combustible material. Assemble the framing kit as per the instructions on pages 10 & 11 of this manual. Attach the steel frame to the  replace once the  replace is in its  nal
position. Secure the steel frame to the framing brackets on each side of the unit. Ensure that the studs are set back far enough to allow for thickness of  nishing surface.
The sides, back and top of the  replace can be framed in up to the steel studs and the  replace standoffs using conventional lumber. Consult local building codes for speci c requirements.
Due to high temperatures, non-combustible backer board is supplied with the  replace and must be used to sheet in the front of the  replace, extending 12" above and 7 1/2"
to
the side of the framing edge bars. (Fig #9) Standard sheet rock (dry wall) may be used beyond this.
Chase Insulation: When installing this  replace against a non-insulated exterior wall or chase, it is recommended that the outer walls be insulated to same degree as other exterior walls. Do not place  replace directly against the insulation. Cover the insulation and plastic vapour barrier with a solid surface, such as dry wall (sheet rock). Consult local codes. Do not insulate or use plastic vapour barrier within the framing kit.
Fig. #8
NON-COMBUSTIBLE ZONE. DO NOT INSTALL ANY COMBUSTIBLE MATERIAL, ELECTRICAL WIRING, INSU­LATION, PLASTIC VAPOR BARRIER OR GAS PLUMBING WITHIN THE STEEL STUD FRAMING
STEEL STUD FRAMING KIT DIMENSIONS
(Supplied with  replace)
NOTE: FOR CLARITY ONLY ONE FACE OF THE TWO­SIDED FIREPLACE IS SHOWN WITH STEEL STUD FRAMING KIT ATTACHED. BOTH FACES MUST BE FRAMED WITH THE STEEL STUD FRAMING KIT SUPPLIED WITH THE FIREPLACE.
ALL OTHER FRAMING CAN BE DONE WITH CONVENTIONAL LUMBER
TC36_CSTE 071010-44
8
Fig. #9
NON-COMBUSTIBLE BOARD
NON-COMBUSTIBLE BOARD
NON-COMBUSTIBLE MATERIAL MUST EXTEND 12" ABOVE AND 7 1/2" TO THE SIDES OF THE FRAMING EDGES.
Fig. #10
NON-COMBUSTIBLE RECESSED INSTALLATION DETAIL
NON-COMBUSTIBLE BOARD
STEEL STUDS
NON-COMBUSTIBLE MATERIAL
Fig. #11
MINIMUM COMBUSTIBLE FRAMING DIMENSIONS
NOTE: FIREPLACE SHOULD BE IN ITS FINAL LOCATION BEFORE FRAMING.
TC36_CSTE 071010-44
9
TC36 Steel Stud Framing Kit
TC36.CSFRKITA
Each Kit Contains:
1
2
3
4
5
6
7
8
9
10
Item Part # Description Qty.
1 5049.9912 SCREW, TEKS Pkg
#8 x 1/2 40
2 9394.001 STUD, SIDES,
48”L 2
3 9794.501 STUD, OUTER
SIDES, 48”L 2
4 9093.22 STUD, CENTER,
15 1/2”L 2
5 9393.21 STUD, HEADER,
54 1/4”L 1
6 9393.001 STUD, PLATE,
41 1/4”L 1
7 9394.21 BASE PLATE ,
8”L 2
8 9397.01 NON-COMBUSTIBLE BOARD,
TOP 12” x 53 3/8” 1
9 9798 NON-COMBUSTIBLE BOARD,
SIDE 7 1/2” x 32” 2
10 5049.993 SCREW, DRYWALL, Pkg
1 1/4” 30
Fig. #12
1. Top Frame Assembly
Lay out side studs (2) and center studs
(4) on a large  at surface. (Fig #12)
5
Using the screws provided (1), attach the
header stud (5) and the plate stud (6) to the center studs (4).
4
6
2
TC36_CSTE 071010-44
10
2. Attach Side Studs (Legs)
Fig. #13
Attach the outer side studs (3) to the top of the header stud (5). (Fig #13)
Fasten the outer side studs (3) at the
bottom using the base plates (7).
NAIL TABS
3. Attach the Assembled Frame to
the Unit
Align the assembled frame to the unit
framing brackets. (Fig #14) Attach at
the fastening points through the
access holes in the outer side studs
(3).
5
3
7
Fig. #14
5
4. Secure to Existing Framing
Secure the frame assembly to existing
framing through the stud header (5) and the stud plates (7).
5. Install Non-combustible Board Top and Sides
Use drywall screws (10) to install the
non-combustible board top (8) and sides
(9).
Fig. #15
Framing Brackets
7
Access holes to mounting screws
8
TC36_CSTE 071010-44
9
11
1/4"
1" MAX
Hearth Extension
Fig. #20
WINDOW
FRAME
HEARTH
EXTENSION
While a hearth extension is not required for this  replace, one is recommended for aesthetic reasons. The hearth extension should be noncombustible and must not be any more than 1" above the bottom of the  replace. If thicker,  replace must be raised up accordingly.
Caution: Hearth extensions thicker than 1" will interfere with the window frame.
WINDOW
TRACK
SUB-
FLOOR
TC36_CSTE 071010-44
12
Maestro Control – Plumbing and Electrical
ACCESS PANEL
The gas control system is located on the side of the  rebox behind an access panel and the decorative  rebox panel (if installed). The  replace is operated via a wall control and a hand held remote control unit.
The wall control is connected to the  replace by a 25 ft. communication cable supplied with the  replace. The communication cable can be extended to 50 ft. with an optional 25 ft. extension kit.
Installation
1. Place the  replace in the desired location.
2. Remove the window from the  replace.
3. Remove access panel from right hand side of the  rebox (Fig #21)
4. Connect a 110 V. AC electrical supply to the outlet installed inside the control box
(Fig #22)
OUTLET
Fig. #21
Fig. #22
5. Connect the gas supply to the valve (Fig #23)
GAS CONNECTION
6. Plug the A/C adaptor into the outlet (Fig #24)
7. Attach the electrical box for the supplied wall control to the framing in the desired
location (up to 50 ft. away). (25 ft is supplied with  replace. An additional 25 ft can be achieved by using the optional kit (Part # 5005.064) available from your dealer).
ADAPTOR
Fig. #23
Fig. #24
TC36_CSTE 071010-44
13
8. Route the control cable as required to the wall control electrical box.
9. Attach the control cable to the wall control. (Fig #25)
10. Insert the 4 supplied “AA” batteries into the battery pack and connect to wall control.
(Fig #26)
11. Fasten the wall switch to the electrical box.
12. Fasten the faceplate to switch
13. If not already installed, install the burner and log set using the instructions supplied
with the burner kit.
14. Turn on the gas supply and check that all connections are tight and leak free.
15. Turn on gas and electrical supplies.
16. Press the center button on the wall control (Fig #27). The igniter will start to spark.
After a short delay the pilot will light, followed by the main burner.
17. Press the up button on the wall control and hold it for 5 seconds or until a clicking sound is heard from the gas control. Re­lease the button, check manifold pressure
Fig. #27
and ensure that it’s correct. (Fig #28)
Refer to burner installation manual.
Fig. #25
Fig. #26
Fig. #28
18. Press the center button of the wall control. The  replace will shut off.
19. Install the remaining screws in the access panel and tighten.
20. Remove the pressure gauge and the extension test  tting and thread the pressure test port plug into the pressure test port. Thread sealant is required on the threads. Refer to burner installation manual.
21. Turn the  replace on and verify that the connections are tight.
Standing Pilot Function
(Only for use where permitted)
The control system on this  replace is set to operate as electronic ignition. If required the system can be converted to a standing pilot by depressing a recessed button located on the lower right hand side of the wall control. (Fig #29) This should be depressed with a paperclip, pencil or other thin object. Once activated the pilot will run continuously. Please check with your local inspector to ensure that this is permitted in your area.
LEARN BUTTON
Fig. #29
STANDING PILOT BUTTON
TC36_CSTE 071010-44