Town & Country Fireplaces TC36.RHKA Installation And Operation Instructions Manual

IMPORTANT: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER
OPTIONAL REMOTE KIT
HEAT OUTLET DUCT
MAKE-UP AIR INLET DUCT
TC36.RHKA
INSTALLATION AND
240506-8 TC36.RHKA 5056.4277
OPERATING INSTRUCTIONS
Replacement Parts
ITEM DESCRIPTION PART NUMBER ITEM DESCRIPTION PART NUMBER
1...... DUCT ADAPTER PLATE ................... TC36.9128
2...... OUTLET GRILL ....................................5096.854
3...... REMOTE HEAT FLAP BOX ............... TC36.9122
4...... TRANSITION BOOT .............................5096.853
5...... BLOWER CASING FACE PLATE ................ 9144
6...... BLOWER FAN BRACKET ............................ 9146
7...... BLOWER WALL BRACKET ......................... 9147
8...... REMOTE BLOWER BOX ................... TC36.9141
9...... BLOWER ................................................. 5024.65
12
7 5/16”
15 5/16”
4
7
10 ..... WIRE PIG TAIL ............................... TC36.50625
11 ..... INLET GRILL ....................................... 5096.851
12 ..... INLET ADAPTER BOOT ..................... 5096.852
13 ..... JUNCTION BOX .................................. 5024.408
14 ..... RHEOSTAT KIT ................................... 5025.001
........ REMOTE BLOWER ASSEMBLY
............. (Items 5 to 10) ............................... TC36.9141
3
8
9
14
6
5
12 11
7
10
13
7 3/8”
7 3/8”
070606-8 TC36.RHKA 5056.4277
2
The amount of heat from this kit is affected by the length and number of bends. To maximize the performance the length and number of bends should be kept to a minimum.
MAXIMUM
DUCT LENGTH OF 25 FT.
INSTALLATION EXAMPLES
Duct clearance to combustible material:
- within 36” of unit = 1/2”
- more than 36” from unit = 0”
ROUND DUCT (6”)
RECTANGULAR DUCT
(10” X 3 1/4”)
MAXIMUM
DUCT LENGTH OF 25 FT.