Town & Country Fireplaces TC36.CE3, TC36.CARE3 Installation And Operating Instructions Manual

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
WARNING: If the information in these instructions is not followed exactly, a re or explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
r %POPUUSZUPMJHIUBOZBQQMJBODF r %POPUUPVDIBOZFMFDUSJDBMTXJUDI r%POPUVTFBOZQIPOFJOZPVSCVJMEJOH r *NNFEJBUFMZDBMMZPVSHBTTVQQMJFSGSPN
a neighbour’s phone. Follow the gas supplier’s instructions.
r *GZPVDBOOPUSFBDIZPVSHBTTVQQMJFSDBMM
the re department.
SERIAL #
TC36.CE3 & TC36.CARE3 INSTALLATION AND OPERATING INSTRUCTIONS
Installation and service must be performed by a qualied installer, service agency or the gas supplier.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certied kit is used.
This appliance is suitable for installation in a bedroom or bed sitting room.
MODEL: TC36 & TC36AR SERIES C MODULAR DIRECT VENT
250313-48 TC36.CE3 &TC36.CARE2 5056.427CE
FIREPLACE
Table of Contents
Caution ........................................................................................... 3
Safety Fireplace Dimensions Minimum Clearances to Combustible Material Installation Requirements Manufactured (Mobile) Home Window Frame Removal Locating The Fireplace Top Standoffs Framing and Finishing TC36 Steel Stud Framing Kit TC36 Arched Steel Stud Framing Kit Adjustable Lintel Hearth Extension Maestro Control Plumbing and Electrical Gas Supply Gas Pressure Check Venting Wall Termination Venting Wall Termination Venting Chart Roof Termination Venting Chart Vent Terminal Clearance Vent Terminal Minimum Clearances Vent Pipe Sealant Insulated Collar Shield (Included) Vent Restrictor Adjustment Firebox Panels Installation Finishing Touch Trim Kit Instructions Lighting Instructions First Fire Maestro Control System Remote Control Initial Setup Maestro Control System - Operation Maintenance TC36.CE3 Replacement Parts TC36.CARE3 Replacement Parts Replacement Parts – Maestro Control System Wiring Diagram Wall Termination Kit Roof Termination Kit Wall Shield/ Ceiling Firestop Thimble Vent Pipe Dimensions Vent Offset Chart
Light Replacement ........................................................................45
Safety Label Location
.............................................................................................3
..................................................................... 5
...............................5
............................................................... 6
......................................................... 6
.................................................................6
................................................................... 7
.................................................................................. 7
....................................................................8
........................................................ 10
............................................ 12
...........................................................................14
.......................................................................... 15
........................................................................... 16
................................................................ 16
................................................................................... 19
..................................................................... 19
..........................................................................................20
..............................................................20
.....................................................23
.................................................... 24
...............................................................27
.............................................27
......................................................................... 28
.................................................28
...........................................................29
............................................................ 30
.............................................31
.....................................................................32
........................................................................................32
...............................................................33
......................................................... 33
............................................34
................................................................................. 37
.....................................................38
................................................39
............................. 40
............................................................................. 41
.................................................................... 42
...................................................................42
...................................................................................42
............................................................... 42
.................................................................43
.......................................................................... 44
................................................................... 47
TC36.CE3 250313-48
2
Caution
FOR YOUR SAFETY - Do not install or operate your Town & Country replace without
rst reading and understanding this manual. Any installation or operational deviation from the following instructions voids the Town & Country Fireplaces hazardous.
This appliance and its individual shut off valve must be disconnected from gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
Note: When lit for the rst time, the appliance will emit a slight odour for a couple of hours. This is due to the curing of paints, sealants and lubricants used in the manufacturing process. This condition is temporary. Open doors and windows to ventilate area. Smoke and fumes caused by the curing process may cause discomfort to some individuals.
Do not use the replace if any part has been under water. Immediately call a qualied service technician to inspect the replace and to replace any part of the control system and any gas control which has been under water.
TM
Warranty and may prove
Safety
Due to high temperatures, this gas appliance should be located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance.
Clothing or other ammable material should not be placed on or near the appliance.
Any grill, panel or door removed for servicing the unit must be replaced prior to operating. Failure to do so may create a hazardous condition.
Installation and repair should be done by a qualied service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc.. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
It is our policy that no responsibility is assumed by the Company or by any of its employees or representatives for any damages caused by an inoperable, inadequate, or unsafe condition which is the result, either directly or indirectly, of any improper operation or installation procedures.
This appliance must not be connected to a chimney ue serving a separate solid fuel burning appliance.
TC36.CE3 250313-48
3
Important Note for the Commonwealth of Massachusetts:
From Massachusetts Rules and Regulations 248 CMR 5.08:
(a) For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential
purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above
nished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satised.
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fuelled equipment, the
installing plumber or gas tter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the oor level
where the gas equipment is to be installed, in addition, the installing plumber or gas tter shall observe that a battery operated or hard-wired carbon
monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas
fuelled equipment. It shall be the responsibility of the property owner to secure the services of qualied licensed professionals for the installation of
hard-wired carbon monoxide detectors.
a. In the event that the side wall horizontally vented gas fuelled equipment is installed in a crawl space or an attic, the hard-wired carbon monoxide
detector with alarm and battery back-up may be installed on the next adjacent oor level.
b. In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall have a period of thirty
(30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detec-
tor with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall
comply with NFPA 720 and be ANSI/UL 2034 listed as IAS certied.
3. SIGNAGE. A metal or plastic identication plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet
above grade directly in line with the exhaust vent terminal for the horizontally vented gas fuelled heating appliance or equipment. The sign shall read, in
print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fuelled equipment shall not approve the installation unless,
upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.089(2)(a) 1
through 4.
(b) EXEMPTIONS. The following equipment is exempt from 248 CMR 5.089(2)(a) 1 through 4.
1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the
Board; and
2. Product Approved side wall horizontal vented gas fuelled equipment installed in a room or structure separate from the dwelling, building or struc-
ture used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side
wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by
the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved
side wall horizontally vented gas fuelled equipment does not provide the parts for venting the fuel gases, but identies “special venting systems”, the fol-
lowing requirements shall be satised by the manufacturer.
1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and
2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed
installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fuelled equipment, all venting instructions, all parts
lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
TC36.CE3 250313-48
4
48 9/16
26
24
38 1/2
47 7/8
32 1/2
11 11/16
38 1/2
11 11/16
47 7/8
32 1/2
38 1/2
28 1/8
11 1/8
36 1/8
24
Fireplace Dimensions
Fig. #1
STEEL STUD FRAMING KIT IS WIDER THAN UNIT
Minimum Clearances to Combustible Material
Fig. #2
COMBUSTIBLE FRAMING AND FINISH WALL ABOVE STANDOFFS
MAY USE COMBUSTIBLE FACING MATERIAL IN THIS AREA
NON-COMBUSTIBLE FINISH MATERIAL SEE FIG #7
STEEL FRAMING
STANDOFFS
D
E
NON-COMBUSTIBLE ZONE. DO NOT INSTALL ANY COMBUSTIBLE MATERI­AL, ELECTRICAL WIRING OR GAS PLUMBING IN THIS AREA.
MANTEL CLEARANCE
CHART
* MANTEL CLEARANCE
A 9”
F
C
MANTEL
**
Fig. #3
A
B
TOP OF LINTEL BAR
FIREPLACE FRONT
CEILING
24”
24"
*
32 1/8”
TC36.CE3 250313-48
38 1/8"
UNIT MAY BE RECESSED UP TO 6” WITH NON-CUMBUSTIBLE MASONRY TYPE MATERIAL
ADJACENT WALL OR MANTEL SUPPORT
4”
B 6”
C 3”
** MANTEL DEPTH
D 12”
E 6 3/4”
F 1 1/2”
Minimum Clearances:
Side standoffs .......................................................0 in. (0 mm)
Back standoffs ...................................................... 0 in. (0 mm)
Top standoffs ........................................................0 in. (0 mm)
Bottom of appliance ..............................................0 in. (0 mm)
Adjacent side wall .................................................4 in. (102 mm)
Ceiling to appliance ............................................24 in. (610 mm)
4"
*Mantel to appliance .................. ..........See Figure #2
**Maximum Mantel extension .. ..........See Figure #2
Mantel support ......................................................4 in. (102 mm)
Vertical vent pipe ..........................................1 3/4" in. (45 mm)
Horizontal Vent pipe (Top, sides and bottom) 1 3/4" in. (45 mm)
5
Fig. #4
Fig. #5
Installation Requirements
The Town & Country Fireplace installation and venting must conform to the current CAN/CGA-B149 installation code (in Canada) or the current National Fuel Gas Code, ANSI Z223.1 (in the USA), and approved per local codes. Only qualied (licensed or trained) personnel should install this product.
In the state of Massachusetts, only a licensed Plumber and Gas Fitter may install this product.
Manufactured (Mobile) Home
In some jurisdictions, the Town & Country Fireplace may be installed in Manufactured Homes after the "rst sale". Consult local codes for approval. The replace must be fastened in place.
Install in accordance with the current standard Mobile Homes, CAN/CSA Z240 MH (in CANADA), and the Manufacturer's Home Construction and Safety Standard, Title 24 CFR, Part 3280 or the current Standard for Fire Safety Criteria for Manufactured Home Installa­tions, Sites and Communities ANSI/NFPA 501A (in the USA).
Window Frame Removal
Fig. #5a
LATCH HANDLE
Warning: Turn off the replace, and allow ample time for the unit to cool before proceeding.
Caution: The ceramic glass is very fragile, and should be handled with care.
The window frame is held in place by two spring-loaded latches that are operated by a one-piece latch handle.
1. Remove the TC Finishing Touch Trim Kit from the window frame. (If installed)
2. Using a screwdriver or other similar object, push against the notch in the top of the latch and grab the bottom of the latch handle as it protrudes. Lift handle until latch hook disengages. Repeat for other side while holding glass so it does not tip out.
3. Tilt the top of the window frame out to clear the top edge of the unit. Grasp the sides of the frame and lift up and out to disengage from its bottom track.
4. Place the window frame in a safe place to avoid damage.
5. Re-assemble in reverse order. Latch handle should snap into place and be ush with
window frame when engaged correctly.
TIP: To ensure glass is properly latched, grasp the top left and
right sides of the glass frame, under moderate pressure it should pull forward and return to original position evenly on both sides.
6. Reinstall Trim Kit if required.
TC36.CE3 250313-48
6
Top Standoffs
The top standoffs are shipped loose inside the replace and must be installed on top of the replace as shown in Fig #6. Do this once the replace is on site and in position.
Locating The Fireplace
Fig. #6
TOP STANDOFFS
In planning the installation for the replace, it is necessary to determine where the unit is to be installed, location of vent system and where gas supply piping may be plumbed. Various installations are possible, such as, into an existing wall, a corner, a built-in wall or a wall projection (Fig #7). Due to high temperatures, do not locate this replace in areas of high traffic or near furniture or draperies.
The minimum clearances from the replace to combustible surfaces must be adhered to and are shown in Fig #2 and Fig #3.
Fig. #7
EXAMPLES OF COMMON LOCATIONS SEE FIG #11 FOR DIMENSIONS
TC36.CE3 250313-48
7
50
1/4
48 1/8”
Framing and Finishing
Note: The replace should be in place and venting installed before framing in or building an enclosure around the unit.
The Town & Country replace must be framed in as described below or totally en­closed with non-combustible material, such as facing brick.
Determine the total thickness of facing material to be used. A thickness of 3/4" will allow the nishing surface to be ush with the front of the unit. If preferred, additional masonry type non-combustible material can be installed above and to the sides up to 6 inches proud of the appliance.
The nishing material must not interfere with glass frame access.
A Steel Stud Framing Kit is supplied with the
replace and must be used unless the replace is totally enclosed with
non-combustible material. Assemble the framing kit as per the instructions on pages 10 & 11 of this manual. Attach the steel frame to the replace once the replace is in its nal
position. Secure the steel frame to the framing brackets on each side of the unit. Ensure that the studs are set back far enough to allow for thickness of nishing surface.
The sides, back and top of the replace can be framed in up to the steel studs and the replace standoffs using conventional lumber. Consult local building codes for specic requirements.
Due to high temperatures, non-combustible backer board, such as cement board or its equivalent, must be used to sheet in the front of the replace, extending 12" above and 5 9/16" to the side of the framing edge bars. (Fig #9) Standard sheet rock (dry wall) may be used beyond this.
If the backer board is not to be nished with other non-combustible material such as tiles, it is recommended that top sections of the board be a single sheet of calcium silicate board or its equivalent. Taped and mudded joints may crack due to the elevated temperatures.
Chase Insulation: When installing this replace against a non-insulated exterior wall or chase, it is recommended that the outer walls be insulated to same degree as other exterior walls. Do not place replace directly against the insulation. Cover the insulation and plastic vapour barrier with a solid surface, such as dry wall (sheet rock). Consult local codes. Do not insulate or use plastic vapour barrier within the framing kit.
CAUTION: SEE FIGURE #9a BEFORE PROCEEDING.
NOTE:
The chase must be properly sealed at the ceiling level or between oors in a multilevel
installation.
Fig. #8
NON-COMBUSTIBLE ZONE. DO NOT INSTALL ANY COMBUSTIBLE MATERIAL, ELECTRICAL WIRING, INSU­LATION, PLASTIC VAPOR BARRIER OR GAS PLUMBING WITHIN THE STEEL STUD FRAMING
STEEL STUD FRAMING KIT DIMENSIONS
(Supplied with replace)
ALL OTHER FRAMING CAN BE DONE WITH CONVENTIONAL LUMBER
IT IS HIGHLY RECOMEND­ED THAT A FULL HEADER BE INSTALLED ABOVE THE METAL FRAMING KIT
TC36.CE3 250313-48
8
5 9/16”
12”
20 13/16”
56 9/16”
29 3/8”
50 1/4”
79 15/16”
56 9/16”
Fig. #9
Fig. #9a
NON-COMBUSTIBLE BOARD DETAIL
NON-COMBUSTIBLE BOARD
NON-COMBUSTIBLE MATERIALS MUST EXTEND 12" ABOVE AND 5 9/16" TO THE SIDES OF THE FRAMING EDGES.
Fig. #10
NON-COMBUSTIBLE RECESSED INSTALLATION DETAIL
NON-COMBUSTIBLE BOARD
USE FULL SHEETS OF CALCIUM SILICATE BOARD AND FULL LENGTH METAL STUDS TO FINISH AND FRAME AROUND THE UNIT. CALCIUM SILICATE BOARD IS A HIGH GRADE MATERIAL WITH CEMENT, QUARTZ AND NATURAL MINERALS AS THE MAIN RAW MATERIALS. (NOTE: CALCIUM SILICATE IS 1/2” THICK)
CAUTION: CALCIUM SILICATE BOARD CAN BE DAMAGED IF DROPPED OR STRUCK. HANDLE WITH CARE. INSPECT BOARD PRIOR TO INSTALLATION AND DO NOT USE IF CRACKED.
NOTE: IT IS RECOMMENDED TO PRE-DRILL MOUNTING HOLES IN THE BOARD PRIOR TO SECURING TO THE FRAMING. THIS WILL PREVENT THE BOARD FROM CRACKING.
CALCIUM SILICATE BOARD
STEEL STUDS
NON-COMBUSTIBLE MATERIAL
Fig. #11
23 3/8”
MAXIMUM FACING DEPTH
MINIMUM COMBUSTIBLE FRAMING DIMENSIONS
Including Sheetrock
50 1/4”
12 11/16”
3/4”
48 1/4”
50 1/4”
NOTE: FIREPLACE SHOULD BE IN ITS FINAL LOCATION BEFORE FRAMING.
TC36.CE3 250313-48
9
TC36 Steel Stud Framing Kit
TC36.B2FRKITA
Each Kit Contains:
1
2
3
4
5
6
7
Item Part # Description Qty.
1 5049.9912 SCREW, TEKS Pkg #8 x 1/2” 40
2 9794.2 STUD, SIDES, 48”L 2
3 9794.5 STUD, OUTER SIDES, 48”L 2
4 9093.22 STUD, CENTER, 15 7/16”L 2
5 9193.501 STUD, HEADER, 49 7/8”L 1
6 9393.001 STUD, PLATE, 41 1/4”L 1
7 9194.5 BASE PLATE , 5 15/16”L 2
Fig. #12
1. Top Frame Assembly
r Lay out side studs (2) and center studs
(4) on a large at surface. (Fig #12)
5
r Using the screws provided (1), attach the
header stud (5) and the plate stud (6) to the center studs (4).
4
6
2
TC36.CE3 250313-48
10
2. Attach Side Studs (Legs)
Fig. #13
r "UUBDIUIFPVUFSTJEFTUVETUPUIFUPQ
of the header stud (5). (Fig #13)
r Fasten the outer side studs (3) at the
bottom using the base plates (7).
3. Attach the Assembled Frame to the Unit
r "MJHOUIFBTTFNCMFEGSBNFUPUIFVOJU
framing brackets. (Fig #14) Attach at the fastening points through the access holes in the outer side studs
(3).
5
3
7
Fig. #14
5
4. Secure to Existing Framing
r Secure the frame assembly to existing
framing through the stud header (5) and the stud plates (7).
5. Install Non-combustible Board
r Use drywall screws to install the
non-combustible board (Fig #15).
Fig. #15
Framing Brackets
7
Access holes to mounting screws
TC36.CE3 250313-48
11
TC36 Arched Steel Stud Framing Kit
Each Kit Contains:
Item Part # Description Qty.
1 5049.9912 SCREW, TEKS Pkg
1
2
3
4
5
#8 x 1/2” 40
2 9794.2 STUD, SIDES, 48”L 2
3 9794.5 STUD, OUTER SIDES, 48”L 2
4 9093.22 STUD, CENTER, 15 7/16”L 2
5 9193.501 STUD, HEADER, 49 7/8”L 1
6 9393.001 STUD, PLATE, 41 1/4”L 1
TC36.BRFRKITA
6
7
8
Fig. #19
2
7 9194.5 BASE PLATE , 5 15/16”L 2
8 9596 ARCH SUPPORT 2
5
1. Top Frame Assembly
Attachment point
r Lay out side studs (2) and center studs
(4) on a large at surface. (Fig #19)
4
r Using the screws provided (1), attach the
header stud (5) and the plate stud (6) to the center studs (4).
8
6
Attachment point
Attach together
8
Attachment point
2
TC36.CE3 250313-48
12
2. Attach Side Studs (Legs)
Fig. #20
r "UUBDIUIFPVUFSTJEFTUVETUPUIFUPQ
of the header stud (5). (Fig #20)
r Fasten the outer side studs (3) at the
bottom using the base plates (7).
3. Attach the Assembled Frame to the Unit
r "MJHOUIFBTTFNCMFEGSBNFUPUIFVOJU
framing brackets. (Fig #21) Attach at the fastening points through the access holes in the outer side studs
(3).
5
3
7
Fig. #21
5
4. Secure to Existing Framing
r Secure the frame assembly to existing
framing through the stud header (5) and the stud plates (7).
5. Install Non-combustible Board
r Use drywall screws to install the
non-combustible board (Fig #22).
Fig. #22
Framing Brackets
7
Access holes to mounting screws
TC36.CE3 250313-48
13
Adjustable Lintel
1. The adjustable lintel assembly has two orientations for desired nishing. A anged edge and a hemmed edge. The lintel comes factory installed with the ange edge out. If the desired edge is different from the factory setting, use the following steps to change it(Fig.#21).
2. Remove the window trim (Fig.#22).
3. Loosen the securing bolts in the upper and lower corners on each side of the lintel and remove the lintel. Rotate the assembly to have the desired edge away from the replace(Fig .#23).
4. The lintel assembly has a maximum range of adjustability of 1” to accommodate varying facing material thicknesses. The maximum depth is 6” (Fig.#25).
5. The lintel assembly can then be adjusted to align ush with your facing material by sliding in or out approximately 1”.
6. Tighten the securing bolts. (Fig.#23).
Fig. #16
HEMMED EDGE
FLANGED EDGE
Fig. #17
7. Re-attach the window trim.
TRIM
Fig. #18
SECURING BOLT
TC36.CE3 250313-48
14
1/4"
1" MAX
Hearth Extension
Fig. #23
WINDOW
FRAME
This replace may be recessed up to a maximum depth of 6”, this recess must be constructed from non combustible material. The space between the outside framing edge and the rebox must be completely free of any obstructions or debris and the window, with trim tted, must be able to move freely. No building material is permitted to protrude past the framing edges attached to the replace under ANY circumstance.
HEARTH
EXTENSION
Caution: While a hearth extension is not required and combustible ooring materials may be brought directly up to the replace, many materials (such as wood ooring) may not tolerate the radiant heat from this replace, resulting in discoloration, shrinking and cracking. For this reason, we suggest a non-combustible hearth that is no more than 1” above the bottom of the replace. If thicker, replaced must be raised accordingly.
Caution: Hearth extensions thicker than 1” will interfere with the window frame when opening.
Fig. #24
WINDOW
TRACK
SUB-
FLOOR
FRAMING EDGES
GLASS FRAME
NON COMBUSTIBLE FINISH MATERIAL
TC36.CE3 250313-48
15