![](/html/12/12a2/12a28796ca329bc26e042c9ef79fb2ae687396a22334450b49f055391cc9d7c5/bg1.png)
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
These instructions are supplementary to the Installation and
Operating Instructions supplied with the replace and should be
kept together. Refer to the Installation and Operating Instructions for
proper gas supply, safety requirements and operating instructions
TC30
COUNTRY HOME
BURNER KIT
INSTRUCTIONS
(NATURAL GAS ONLY)
Visit www. townandcountryfireplaces.net for the most recent version of this manual
020317-16 TC30_NG02DN 5056.42902D
PART#
TC30.NG02DN
For TC30 Series D
Fireplaces
![](/html/12/12a2/12a28796ca329bc26e042c9ef79fb2ae687396a22334450b49f055391cc9d7c5/bg2.png)
Contents of Package
Burner Assembly
Hardware Package
7 Pc Log Set
Ember
Material
Log Grate
Figure 1: TC30_NG02DN Kit contents.
Burner/Grate Installation
Screws
Figure 2: Firebox base.
1. Place the keyhole slots of the burner (Figure 3) over the two screws located on the rebox oor
(Figure 2).
5056.42902D
2
TC30_NG02DN 020317-16
![](/html/12/12a2/12a28796ca329bc26e042c9ef79fb2ae687396a22334450b49f055391cc9d7c5/bg3.png)
Figure 3: Burner assembly over top of right side screw.
Figure 4: Burner assembly pushed back against right
side screw.
2. Slide the burner back to engage the screws in the small part of the keyhole slot and tighten
screws (Figure 4).
3. Remove access cover to the vavle control center from right side of rebox (Figure 5)
Figure 5: Access cover to valve control center.
TC30_NG02DN 020317-16
3
5056.42902D
![](/html/12/12a2/12a28796ca329bc26e042c9ef79fb2ae687396a22334450b49f055391cc9d7c5/bg4.png)
Figure 6: Gas and pilot supply tubes.
Interface module
4. Attach the pilot and gas supply tubes to the bulk head tting and tighten (Figure 6). Ensure the
connections are gas tight.
Interface module
Ignition and sensor wires
Bulkhead plate
Figure 7: Ignition and sensor wires routing.
5. Feed the ignition and sensor wires through the bulkhead plate to the interface module. Tuck the
ignition and sensor wires below the supply tubes (Figure 7).
5056.42902D
4
TC30_NG02DN 020317-16
![](/html/12/12a2/12a28796ca329bc26e042c9ef79fb2ae687396a22334450b49f055391cc9d7c5/bg5.png)
Flame sensor
wire (white)
Interface module
Figure 8: Interface module.
Ignition wire (red)
6. Attach the ignition and sensor wires to the Interface module as shown in Figure 8.
7. Reinstall the valve control center access panel (See Figure 5 on page 3).
A panel set must now be installed before the before the
log grate can be installed. See Installation and Operating
Instructions manual for details.
TC30_NG02DN 020317-16
5
5056.42902D