TC30.NG02DN For TC30 Series D Fireplaces
Contents of Package
Burner Assembly
Hardware Package
7 Pc Log Set
Ember Material
Log Grate
Figure 1: TC30_NG02DN Kit contents.
Burner/Grate Installation
Screws
Figure 2: Firebox base.
1. Place the keyhole slots of the burner (Figure 3) over the two screws located on the rebox oor (Figure 2).
5056.42902D
2
TC30_NG02DN 020317-16
Figure 3: Burner assembly over top of right side screw.
Figure 4: Burner assembly pushed back against right
side screw.
2. Slide the burner back to engage the screws in the small part of the keyhole slot and tighten screws (Figure 4).
3. Remove access cover to the vavle control center from right side of rebox (Figure 5)
Figure 5: Access cover to valve control center.
TC30_NG02DN 020317-16
3
5056.42902D
Figure 6: Gas and pilot supply tubes.
Interface module
4. Attach the pilot and gas supply tubes to the bulk head tting and tighten (Figure 6). Ensure the connections are gas tight.
Interface module
Ignition and sensor wires
Bulkhead plate
Figure 7: Ignition and sensor wires routing.
5. Feed the ignition and sensor wires through the bulkhead plate to the interface module. Tuck the ignition and sensor wires below the supply tubes (Figure 7).
5056.42902D
4
TC30_NG02DN 020317-16
Flame sensor wire (white)
Interface module
Figure 8: Interface module.
Ignition wire (red)
6. Attach the ignition and sensor wires to the Interface module as shown in Figure 8.
7. Reinstall the valve control center access panel (See Figure 5 on page 3).
A panel set must now be installed before the before the log grate can be installed. See Installation and Operating Instructions manual for details.
TC30_NG02DN 020317-16