Technical Data
TowiTek Universal Access Control Module UAC400
dimensions: 68x55x25 mm power requirements: 12V=(DC) @ 60mA max. maximum load for Relay: 50 VDC / 3A memory storage capacity up to 400 ID's
allowed ambient temperature: 0°C .... 40°C (no condensing moisture)
z.B. RFID-Antenna BN 19 15 27 or RF-Receiver BN 19 15 67
Disposal after end of using life for this product
Electronic devices of all kinds must not be disposed thru regular household waste disposal but should be turned in to a collection
point for proper recycling. Please check with your local
requirements.
Limited Warranty
This product was designed and manufactured with great care and comes with a warranty against material or manufacturing defects at time of purchase. This warranty is valid for 24 months starting with the day of purchase and can be claimed with original sales receipt. The warraty of TowiTek is limited to cost free repairing or replacement of the defective unit. Expenses and risk of transportation; compensation for installation and de-installation and all other expenses which may be related to the repair or exchange of this product are not refunded by TowiTek. The liability for consequential damages resulting from the use of this product – no matter of which exact kind – is generally ruled out.
TowiTek
Universal Access Control
Module UAC400
Nr. 19 15 80
User Guide
www.conrad.com
Thank you for purchasing this product of TowiTek! This user guide contains many important instructions on safe and proper use of this product. The purpose of this
user guide is to make sure you always will get best
performance and reliable operation of your new product.
PLEASE FULLY READ THIS USER GUIDE!
The handling of products operating with electric current requires you to follow the rules from VDE such as VDE 0100, VDE0550/0551, VDE 0700, VDE 0711 and VDE 0860 or other local rules in your country.
TowiTek modules are not designed and authorized for use in life support or life saving applications! Do not use the product for applications in which a temporary or permanent failure or malfunction could cause damage to persons or propery.
If the module is used to switch currents greater 24V it is necessary to have the installation done with no voltage applied and performed by a trained professional authorized for such work. The module may only be used in such application if it was installed in a safe to touch enclosure.
The module must only be used in dry and clean environment. The use near water, heavy dirt and/or high humidity is dangerous and not permitted.
The product must not be used in conjunction with any type of flammable liquid or gas or other environment with risk of spark triggered explosions.
Never exceed the limits or ratings listed in the 'Technical Data' section at the end of this user guide.
If the module is used in schools or educational facilities or similar institutions the operation must be supervised by trained and authorized staff.
The product itself and all parts thereof (including packing material) are not suitable toys for childern! (choking hazard, risk of electric shock, ...)
Intended use for this product
The TowiTek Universal Access Control Module UAC400 is the core processing unit for a simple but highly efficient access control system with up to 400 ID tokens. It is necessary to connect a input device via the Wiegand interface such for as example a RFID-reader or a RF-receiver unit.
Special features of the access control module UAC400
learns up to 400 ID tokens (e.g. cards, transmitters)
display of the the ID numbers
lost ID tokens can be deleted from the memory by choosing the related memory location
high capacity relay switch contact configurable for toggle or timer modes
Operating Instructions
Display of the memory location numbers
The module has a two digit LED display for showing memory location numbers. The last two digits of the memory number are represented by the two digits (00 ... 99). The highest digit (0,1,2,3) for showing the full range of 000..399 are displayed by the two dots on the top edge. The dot on the left side represents '+200' and the dot on the right side '+100'. Here are some examples for displayed numbers:
Clearing all 400 memory locations
Press down and keep down the key 'program' until the yellow LED marked 'learn' will light up for the third time. Release the key while the LED is still lit. The 'learn' LED will now flash quickly. Press the 'program' key again and keep it pressed for at least 1 second until the LED gets dark. The memory now is fully cleared.
If you enter clearing mode by accident and do not intend to erase the memory you can exit while the LED is blinking by pressing the program key just shortly (less than one second).
Learning and deleting ID tokens
The program key is pressed down and released right after the yellow 'learn' LED turns on.
The number of the first free memory location is shown on the display.
The 'learn' LED is dark to show the memory location is free. The memory location number can be changed using the 'up' and 'down' keys. Used memory locations will be indicated by lit yellow 'learn' LED.
After choosing any free or used memory location a new ID token can stored. If the memory location was used before the ID number will be overwritten by the new number. To do so, the new ID is read while the memory number is shown on the display. The 'learn' led will flash quickly after a valid ID number was received.
If the new ID is already known, the display will show the memory location where this ID is stored and the 'learn' LED will be lit to indicate the memory location is used. This prevents that the same ID accidentaly gets stored in more than one memory location.
To store the new ID on the selected memory location the program key is pressed for at least one second.
To return to normal operation mode without saving any changes the program key is pressed shortly (less than one second).
To delete a single memory location manually (for example if an ID token is reported to be lost) the location is selected in learning mode and the programing key is pressed for at least one second. The memory location is cleared and the module returns to normal operation mode.
Configuring the relay contact for toggle or time modes
The relay contact can either be set to toggle or timer mode. Using toggle mode, the contact is alternately closed an opened on reading a valid ID.
If using the timer mode, the relay contact will remain closed for a preset time after reading a valid ID. During the delay time, the display will show a countdown.
The configuration is done with such procedure:
The program key is pressed down and held down until the yellow 'learn' LED will light up for the second time.
The display will show a number in the range of 00 .. 99.
The value '00' represents toggle mode while '01-99' represents timer mode with delay time of 1-99 seconds. The configuration can be adjusted using the 'up' and 'down' keys.
Pressing the program key longer than one second will store the new configuration.
Pressing the program key shortly (less than one second) will exit confituration mode without storing the change.
Mounting and Assembly
The access control module UAC400 is delivered fully assembled in the TowiTek universal enclosure. A printed and shape cut front sticker is supplied with the product.
The universal enclosure can be mounted on standardized DIN-rails (30mm) using the supplied clips.
Connection Diagram
FIND MORE PRODUCTS FROM
EU-Declaration of conformity
The company
TowiTek HK Ltd.
ROOM 1613, 16/F.
TAI YAU BUILDING
181 JOHNSTON ROAD
WANCHAI, HONG KONG
declares in their own responsibility that the product
Universal Access Control Module UAC400
BN 19 15 80
complies to the standards
EN 55022 (EMV emission)
EN 61000-6-1 (EMV tolerance)
The above named company keeps records
with confirm the compliance to the standards
AVAILABLE AT
www.conrad.com
19 15 80 ENG - REV 1.00 / 12.08
Liu Hong Quan Shenzhen 15-12-2008
(managing director)
Loading...