Touchstone 80001, Onyx, 80002, Ivory, 80008 Owner's Manual

...
WALL MOUNTED ELECTRIC FIREPLACE HEATER
Model # :
80001 – Onyx
80002 – Ivory
80008 - Mirror
OWNER’S MANUAL
WARNING
CAUTION
AC 110-120V 60Hz 1500W
Read and understand this entire owner’s manual, including all safety information, before plugging in or using this product. Failure to do so could result in fire, electric shock, or serious personal injury.
Keep this owner’s manual for future reference. If you sell or give this product away, make sure this manual accompanies this product.
Wall Mounted Electric Fireplace
2
www.touchstonehomeproducts.com 800.215.1990
Wall Mounted Electric Fireplace
3
Table of Contents
Contents
General Information ................................................................................................................................................... 5
CSA Approval Listing Information ........................................................................................................................... 5
Fireplace Specifications ............................................................................................................................................ 5
Dimensional Drawings ............................................................................................................................................. 6
Unpacking Your Fireplace ......................................................................................................................................... 7
Parts and Hardware ................................................................................................................................................. 7
Tools Required ...................................................................................................................................................... 7
What’s in the Box ................................................................................................................................................. 7
Unpacking and Setup ................................................................................................................................................ 7
Unpacking Instructions: ........................................................................................................................................ 7
Testing the Fireplace Prior to Installation ............................................................................................................. 8
3-prong Outlet Installation .................................................................................................................................... 8
Installation ................................................................................................................................................................... 9
WARNINGS ............................................................................................................................................................... 9
Choosing Installation Location................................................................................................................................. 9
Choosing Wall Location ....................................................................................................................................... 9
Removing The Wall Mount Bracket From Fireplace .............................................................................................. 10
Removing The Glass Panel ..................................................................................................................................... 11
Wall Mounted Installation ...................................................................................................................................... 12
Heat Disable Switch ................................................................................................................................................ 14
Hanging Fireplace On Mounting Bracket .............................................................................................................. 15
Installing Logs and Glass Crystals ......................................................................................................................... 16
Faux Log Installation Instructions ...................................................................................................................... 16
Glass Crystal Installation Instructions ................................................................................................................ 17
Operating Fireplace .................................................................................................................................................. 19
Power ...................................................................................................................................................................... 19
Methods of Operation ............................................................................................................................................. 20
Control Panel and Remote Control Functions .................................................................................................... 20
Remote Control Operation ...................................................................................................................................... 20
Temperature Limiting Control ................................................................................................................................ 21
Care and Maintenance ............................................................................................................................................. 22
Cleaning .................................................................................................................................................................. 22
Maintenance ............................................................................................................................................................ 22
Warranty ................................................................................................................................................................... 23
www.touchstonehomeproducts.com 800.215.1990
Wall Mounted Electric Fireplace
IMPORTANT SAFETY INFORMATION
WARNING!
THIS FIREPLACE IS HOT WHEN IN OPERATION AND CAN CAUSE SEVERE BURNS Do not operate fireplace before reading and understanding operating instructions. Failure to operate
fireplace according to operating instructions could cause fire or injury.
Risk of burns. This fireplace is HOT when in operation and heating element is ON. Power to the fireplace
should be turned off and the fireplace allowed to cool before servicing. To disconnect power to the fireplace, turn controls to off, then remove plug from outlet.
Do not install damaged, incomplete, or substitute components. Young children should be carefully supervised when they are in same room with fireplace. Toddlers,
young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to the fireplace, install an adjustable safety gate to keep toddlers, young children and other at risk individuals away from the fireplace and hot surfaces.
Clothing and other flammable material should not be placed on or near the fireplace. Due to high temperatures, the fireplace should be located out of traffic and away from furniture and
draperies.
Ensure that you have incorporated adequate safety measures to protect infants/toddlers from touching hot
surfaces.
It is imperative that that the control compartments, circulating blower, and its passageway is the fireplace is
kept clean.
Under no circumstances should this fireplace be modified. Do not use the fireplace if any part has been under water. Do not operate the fireplace with the glass panel removed, cracked or broken. Keep the packaging material out of the reach of children. As with all plastic bags, these are not toys and
should be kept away from children and infants.
Servicing should only be done while the fireplace is disconnected from the power outlet. Unplug fireplace if not being used for an extended period of time. Do not operate this fireplace with a damaged cord or plug after the fireplace malfunctions, has been
dropped, or damaged in any manner.
Do not use outdoors. Never locate fireplace where it may fall into a bathtub or other water container. Do not run the cord under carpeting. Do not cover cord with throw rugs, runners, or the like. Arrange cord
away from traffic area and where it will not be tripped over.
Connect to properly grounded outlets only. Do not insert foreign objects into any ventilation or exhaust opening as this may cause and electric shock,
fire, or damage to the fireplace.
To prevent a possible fire, do not block the air intakes or exhaust in any manner. Do not use on soft
surfaces, like a carpet, where openings may be blocked.
Ensure clearances to combustibles are maintained when building a mantel or shelves above the fireplace.
Elevated temperatures on the wall or in the air above the fireplace can cause melting, discoloration or damage to the decorations, a TV or other electronic components.
4
www.touchstonehomeproducts.com 800.215.1990
Wall Mounted Electric Fireplace
5
General Information
CSA Approval Listing Information
This fireplace has been tested in accordance with the CSA Standards for fixed and location-dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact our technical support department at 800-215-1990 option 2.
Note: This fireplace must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition in the United States or the Canadian Electric Code, CSA C22.1 in Canada.
Fireplace Specifications
Model Number 80001 80002 80008
Description
Voltage
Watts Amps
Fireplace Width
Fireplace Height
Fireplace Depth
Net Weight
Shipping Weight
Onyx Ivory Mirror 120v AC 120v AC 120v AC Max 1500W Max 1500W Max 1500W 15 AMP Grounded Circuit
50.4” 50.4” 50.4”
21.65” 21.65” 21.65”
5.5” 5.5” 5.5” 50 lbs 50 lbs 50 lbs 55 lbs 55 lbs 55 lbs
15 AMP Grounded Circuit
15 AMP Grounded Circuit
www.touchstonehomeproducts.com 800.215.1990
Wall Mounted Electric Fireplace
Dimensional Drawings
80001/80002/80008 – Dimensions
6
www.touchstonehomeproducts.com 800.215.1990
Wall Mounted Electric Fireplace
Unpacking Your Fireplace
Parts and Hardware
Tools Required
Phillips-head screwdriver Stud finder Level Tape measure Electric drill 1/4” wood drill bit
What’s in the Box
7
Wall Bracket
Unpacking and Setup
Unpacking Instructions:
Wood Screws
**screws not drawn to scale**
Remote Control
Crystal Embers
Fire Log
Drywall anchors
**anchors not drawn to scale**
Plastic Tray
Remove all parts and hardware from the carton and place them on a clean, soft, dry surface. Check the parts
list to make sure no parts are missing. If parts are missing, please contact technical support at 800-215-1990 opt 2. for replacement parts.
NOTE: Dispose of plastic bag, as it may cause choking hazard with young children. Do not let children play with plastic bag.
www.touchstonehomeproducts.com 800.215.1990
Wall Mounted Electric Fireplace
8
Wiring
Touchstone Wall Mounted Electric Fireplaces come with a 3-prong plug which plugs into any standard 110v outlet.
Testing the Fireplace Prior to Installation
Before installing the fireplace, test the fireplace to make sure that it operates properly. Plug fireplace into approved outlet and power on fireplace. Once fireplace is tested, continue with
installation.
If you have any problems, please contact technical support at 800-215-1990 opt 2.
3-prong Outlet Installation
Only use this fireplace on a 120V AC, 15-Amp grounded circuit. Never overload the circuit. If this
fireplace trips the circuit breaker, unplug all other appliances on the same circuit before the next use. Avoid plugging other appliances into the same circuit as this fireplace.
Always check the fireplace plug and connections before each use.
Never plug this fireplace into an outlet that is cracked or has any loose wires or connections. Plugging this
fireplace into a faulty outlet could result in the outlet overheating or catching fire.
Make sure this plug fits securely into the outlet. Faulty wall outlet connections or loose plugs can cause the
outlet to overheat. If the outlet or faceplate is hot, discontinue use immediately and have a qualified electrician inspect and/or replace the faulty outlet.
The power cord supplied with the heater has three prongs: two flat blades (live and neutral) and one round
pin (ground). If a 3-slot receptacle is not available, an adapter MUST be used. The adapter MUST be properly grounded to the outlet box (see figure below).
NOTE: Adapter NOT INCLUDED.
www.touchstonehomeproducts.com 800.215.1990