TouchLink CCI Pro 700 User Manual

User Guide
CCI Pro 700
TouchLink Pro Conference Room Control Interface
TouchLink
®
68-2785-01 Rev. B
07 16

Safety Instructions

WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Extron Safety and Regulatory Compliance Guide, part number 68-290-01, on the Extron website,
www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer darauf
aufmerksam machen, dass im Inneren des Gehäuses dieses Produktes gefährliche Spannungen herrschen, die nicht isoliert sind und die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in der
im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung, EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer 68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y mantenimiento recogidas en la documentación proporcionada con el equipo.
Para obtener información sobre directrices de seguridad, cumplimiento de normativas, compatibilidad electromagnética, accesibilidad y temas relacionados, consulte la Guía de cumplimiento de normativas y seguridad de Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du produit d’une tension électrique dangereuse susceptible de provoquer un choc électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance importantes qui se trouvent dans la documentation fournie avec le matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets connexes, lisez les informations de sécurité et de conformité Extron, réf. 68-290-01, sur le site Extron, www.extron.com.
Istruzioni di sicurezza • Italiano
AVVISO: Il simbolo, , se usato sul prodotto, serve ad avvertire l’utente
della presenza di tensione non isolata pericolosa all’interno del contenitore del prodotto che può costituire un rischio di scosse elettriche.
ATTENTZIONE: Il simbolo, , se usato sul prodotto, serve ad avvertire
l’utente della presenza di importanti istruzioni di funzionamento e manutenzione nella documentazione fornita con l’apparecchio.
Per informazioni sulle linee guida di sicurezza, adempimenti normativi, compatibilità EMI/EMF, accessibilità e argomenti correlati, vedere la sicurezza di Extron e Regulatory Compliance Guide, parte numero 68-290-01, sul sito Web Extron, www.extron.com.
Instrukcje bezpieczeństwa • Polska
OSTRZEŻENIE: Ten symbol, , gdy używany na produkt, ma na celu
poinformować użytkownika o obecności izolowanego i niebezpiecznego napięcia wewnątrz obudowy produktu, który może stanowić zagrożenie porażenia prądem elektrycznym.
UWAGI: Ten symbol, , gdy używany na produkt, jest przeznaczony do
ostrzegania użytkownika ważne operacyjne oraz instrukcje konserwacji (obsługi) w literaturze, wyposażone w sprzęt.
Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji wzajemnej zgodności, zgodność EMI/EMF, dostępności i Tematy pokrewne, zobacz Extron bezpieczeństwa i regulacyjnego zgodności przewodnik, część numer
68-290-01, na stronie internetowej Extron, www.extron.com.
Инструкция по технике безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о наличии неизолированного опасного напряжения внутри корпуса продукта, которое может привести к поражению электрическим током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций по эксплуатации и обслуживанию в руководстве, прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности, соблюдении нормативных требований, электромагнитной совместимости (ЭМП/ЭДС), возможности доступа и других вопросах см. руководство по безопасности и соблюдению нормативных требований Extron на сайте Extron: www.extron.com, номер по каталогу - 68-290-01.
安全说明 简体中文
警告: 产品上的这个标志意在警告用户该产品机壳内有暴露的危险 电压,
有触电危险。
注意 产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维修)说明。
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍 使用的特性等相关内容,敬请访问 Extron 网站 www.extron.com,参见 Extron 安全规范指南,产品编号 68-290-01
安全記事 繁體中文
警告: 若產品上使用此符 號,是為了提醒使用者,產品機殼內存在著
可能會導致觸電之風險的未絕緣危險電壓。
注意: 若產品上使 用此符號,是為了提 醒使用者,設備隨附的用戶手冊中有重
要的操作和維護(維修)説明
有關安全性指導方針、法規遵守、EMI/EMF 相容性、存取範圍和相關主題的詳細資 訊,請瀏覽 Extron 網站:www.extron.com,然後參閱《Extron 安全性與法規 遵守手冊》,準則編號 68-290-01。
안전 지침 한국어
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을 경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에 대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및 규제 준수 안내서, 68-290-01 조항을 참조하십시오.
安全上のご注意
警告: この記号 が製品 上に表示 されている場合は、筐体 内に絶縁されて
いない高電 圧が流れ、感電の危険があることを示しています。
注意: この記号 が製品上に表示されている場合は、本機の取扱説明書
に 記載されている重要な操作と保守(整備)の指示についてユーザーの 注 意 を 喚 起する も の で す。
安全上のご注意、法規厳守、EMI/EMF適合性、その他の関連項目に つ い て は 、エ クスト ロンの ウェブ サ イト www.extron.com よ り 『 Extron Safety and Regulatory Compliance Guide』 (P/N 68-290-01) をご覧ください 。
日本語
Copyright
© 2016 Extron Electronics. All rights reserved.
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners. The following registered Trademarks (®), registered service Marks (SM), and Trademarks (™) are the property of RGBSystems, Inc. or Extron Electronics (see the current list of trademarks on the Terms of Use page at www.extron.com):
Registered Trademarks
Extron, AVTrac, Cable Cubby, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, Flat Field, FlexOS, Global Configurator, GlobalViewer, Hideaway, Inline, IPIntercom, IPLink, KeyMinder, LinkLicense, LockIt, MediaLink, MediaPort, NetPA, PlenumVault, PoleVault, PowerCage, PURE3, Quantum, SoundField, SpeedMount, SpeedSwitch, SystemINTEGRATOR, TeamWork, TouchLink, V-Lock, VersaTools, VN-Matrix, VoiceLift, WallVault, WindoWall, XTP, and XTPSystems
(SM)
Registered Service Mark
: S3 Service Support Solutions
Trademarks (™
AAP, AFL (Accu-RateFrameLock), ADSP(Advanced Digital Sync Processing), Auto-Image, CableCover, CDRS(ClassDRippleSuppression), DDSP(Digital Display Sync Processing), DMI (DynamicMotionInterpolation), DriverConfigurator, DSPConfigurator, DSVP(Digital Sync Validation Processing), eLink, Entwine, EQIP, FastBite, FOX, FOXBOX, IP Intercom HelpDesk, MAAP, MicroDigital, ProDSP, QS-FPC(QuickSwitch Front Panel Controller), Room Agent, Scope-Trigger, ShareLink, SIS, SimpleInstructionSet, Skew-Free, SpeedNav, Triple-Action Switching, True4K, Vector™ 4K, WebShare, XTRA, ZipCaddy, ZipClip
(®)
)

FCC Class A Notice

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference. This interference must be corrected at the expense of the user.
NOTE: For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the “Extron Safety and Regulatory
Compliance Guide
” on the Extron website.

Conventions Used in this Guide

Notifications

The following notifications are used in this guide:
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
TIP: A tip provides a suggestion to make working with the application easier.

Software Commands

Commands are written in the fonts shown here:
^AR Merge Scene,,Op1 scene 1,1 ^B 51 ^W^C
[01] R 0004 00300 00400 00800 00600 [02] 35 [17] [03]
EX!*X1&*X2)*X2#*X2! CE}
NOTE: For commands and examples of computer or device responses mentioned
in this guide, the character “0” is used for the number zero and “O” is the capital letter “o.”
Computer responses and directory paths that do not have variables are written in the font shown here:
Variables are written in slanted form as shown here:
Selectable items, such as menu names, menu options, buttons, tabs, and field names are written in the font shown here:

Specifications Availability

Product specifications are available on the Extron website, www.extron.com.

Extron Glossary of Terms

A glossary of terms is available at http://www.extron.com/technology/glossary.aspx.
Reply from 208.132.180.48: bytes=32 times=2ms TTL=32
C:\Program Files\Extron
ping xxx.xxx.xxx.xxx —t
SOH R Data STX Command ETB ETX
From the File menu, select New. Click the OK button.

Contents

Introduction............................................................ 1
Guide Overview .................................................. 1
Product Description ............................................ 1
Features ............................................................. 1
Application Diagram ........................................... 2
Installation Overview ........................................... 3
Panel Features ...................................................... 4
Front Panel Features ........................................... 4
Rear Panel Features ........................................... 5
Rear Panel Access ......................................... 5
Rear Panel Buttons and Connector ................ 6
Cable Routing ................................................. 9
Setup Menu .......................................................... 10
Navigation and Data Entry ................................ 10
Setup Menu System ......................................... 11
Status Submenu ........................................... 11
Network Submenu ........................................ 12
Display Submenu.......................................... 13
Audio Submenu ............................................ 14
Advanced Submenu ..................................... 15
Configuration Software ..................................... 17
Configuration Software Programs ..................... 17
Software Descriptions ................................... 17
Software Overview ........................................ 18
Software Download ...................................... 18
Software Installation ...................................... 19
Internal Web Page ............................................ 19
Web Page Access ........................................ 19
License Information ...................................... 20
Firmware Updates ........................................ 20
Reference Information ...................................... 21
Mounting .......................................................... 21
Network Port Requirements.............................. 21
Button Replacement ......................................... 21
Reset Modes .................................................... 23
Firmware Download .......................................... 24
viiCCI Pro 700 TouchLink Pro Conference Room Control Interface • Contents
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Contents viii

Introduction

This section contains basic information about the Extron CCI Pro 700 TouchLink Pro Conference Room Control Interface. Topics in this section include:
Guide Overview
Product Description
Features
Application Diagram

Guide Overview

This guide contains information about installing, operating, and configuring the CCI Pro 700 TouchLink Pro Conference Room Control Interface. In this guide, the terms “CCI Pro 700” and “interface” refer to the CCI Pro 700 TouchLink Pro Conference Room Control Interface.

Product Description

Features

The CCI Pro 700 is control system user interface optimized for conferences, collaboration, and AV control. It supports many critical functions needed in a conference environment, while providing a powerful and intuitive user interface for room control. The compact CCI Pro 700 includes a 3.5" color information display, a numeric keypad, and backlit buttons. The information display is customized using GUI Designer, and all buttons can be configured and customized using Global Configurator Plus and Professional, and Custom Button Builder.
Fully configurable — Controls conference systems and AV devices from a single
interface.
Audio, video, and Web integration — Works seamlessly with virtually any audio,
video, or Web conference solution.
Software communication support — Supports Microsoft® Lync®, Skype®, and Skype
for Business when used in conjunction with Extron Codec Connect.
IP Link Pro control processor compatibility — Directly communicates with any
IP Link Pro control processor via Ethernet.
Customizable 3.5 inch color information display with context-dependent
buttons — Displays contact information, dialing directories, and call status.
Six customizable function buttons — Control AV devices or call presets. Buttons
are included with labels for display on, display off, and source selection. Create custom labels and order custom buttons by using Custom Button Builder.
Dual color call status indicator — Shows various conference room conditions such
as microphone mute, privacy, or an incoming call.
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Introduction 1
Configurable buttons — Control critical conference functions. These backlit buttons
Projector
Ext TL
12 To To
for volume, navigation, call mode, keypad, and room and conference functions are grouped for easy user operation of the conference environment.
Power over Ethernet (PoE) — Allows the interface to receive power and control over
a single Ethernet cable, eliminating the need for a local power supply (PoE injector sold separately).
Light sensor — Adjusts screen and button brightness as the ambient room lighting
changes.
Adjustable sleep timer — Puts the interface into Sleep mode to save energy when
not in use.
Motion detector — Wakes the interface from Sleep mode when motion is detected
near the interface.
Extron control system software — Fully configures the interface. GUI Designer
configures the LCD screen layout. Global Configurator Plus and Professional configure the button functions.
Support for Extron Control App and Extron Control for Web
Pull-out tray — Provides easy access to reminders or system information, such as
contact numbers or system presets.
Section 508 compliance — Meets or exceeds Section 508 accessibility standards.

Application Diagram

100-240V ~ 50-60Hz
Extron IPCP Pro 550
IP Link Pro Control Processor
Monday, December 16, 2013 7:04 AM
Contacts
Sources
800.633.9876
Name +-
Menu DeleteKey
Andrew
Beth
2
1
ABC3DEF
Charlie
6
MNO5JKL4GHI
David
9
7
WXYZ8TUV
PQRS
Ervin
0
Frank
End
Call
Greg
Call
Harold
Kevin
Enter
Mike
Andrew
(800) 633 - 9876
ron
P Pro 1220TG
" Tabletop uchLink Pro uchpanel
Extron CCI Pro 700
TouchLink Pro Conference Room Control Interface
1234
2 3 7
1 2
1
+-+-
TxRxGTxRxGTxRxGTxRxG SGSG SGSGRTSCTS
SWITCHED 12 VDC 40W MAX TOTAL
3
4
4 5 6 8
5678
+-+-
TxRxGTxRxGTxRxGTxRxGRTSCTS
SGSGSGSG
5A MAX
12 VDC
Video Window
Ethernet
Full
Privacy
Screen
Near
Zoom
End
In
1 2 3
Far
Zoom
End
Out
Camera Display Presets
DVD / VHS
AUTO IMAGE
DEF
3
ABC
MNO
2
6
KL
,@
J
_
WXYZ
5
1
9
TVU
GHI
8
4
#
EO D
OPER
VI
PQRS
0
7
O
I UD A
*
V D /
DV
AUTO IMAGE
DEF
3
BC
O
A
N
M
2
6
KL
,@
J
_
XYZ W
5
1
9
I
U V T
GH
8
4
#
RS
O
PER
E D I
O
V
PQ
0
7
O
I D U A
*
TV
MP3
HS
TV
P M
1234
5678
RECEIVER
3
RECEIV
RELAYSIR/SERIALCOM
HELP
ER
HELP
IPCP PRO 550
PWR OUT = 12W
+V
-SG
+S
eBUS
LAN
1 2 3 4 G
FLEX I/O
Ethernet
TCP/IP
Network
RS-232
Blu-ray Player
IR
IR
1
1
STANDBY/ON
Satellite Receiver
PUSH PUSH
POWER GUIDE MENU RES 480 480p720p1080i1080p
DIRECTV
INPUTS
2
3
5
4
6 7
10
9
8
OUTPUTS
2
3
5
4
6 7
10
9
8
Extron XTP CrossPoint 1600
Modular Digital Matrix Switcher
11
11
SELECT
12
13
13
12
PQLS HDMI OPEN/CLOSEFL OFF
14
15
14
15
Ethernet
LANLAN
Cameras
Table Microphone with Mute and Light Control
Digital I/O Control
Document Camera
DIRECTV HD
16
16
ENTERPRESET
CONFIG
Video Conference Codec
Wireless Microphones
USB
CONTROL
ESC
VIEW
PRIMARY
REDUNDANT
POWER
XTP CROSSPOINT 1600
XTP SERIES DIGITAL MATRIX SWITCHER
I/OINPUTS
ING POWER 12V
1.0A MAX
I/O
AUDIO
VIDEO
1
2345
0102 ING0102ING0102IN G0102ING01 02
1
2345
Extron SI 3CT LP
Full-Range Speakers
Extron XPA 2001-70V
Power Ampliers
100-240V ~ 0.7A MAX
MIC +48V
1234
MIC/LINE INPUTS
5678
50/60 Hz
AT
234
1
Extron AXP 50 C AT
Audio Expansion Processor (Audio Expansion Typical of 5)
1
RESET
AXP 50 C AT
910
4 1
DMP 128 C AT
11 1273625
8
100-240V 0.5A, 50-60Hz
XPA 2001-70V
LIMITER/PROTECT
SIGNAL
OUTPUTS
Dante
Network
ATTENUATION HPF
10
12
8
6
14
80 Hz
18
4 2
26
OFF
0
234
56 78
INPUTS
L (SUMMED)
REMOTE
10V
50mA
R
G
GCV
DIGITAL I/O
70 V OUTPUT
STANDBY
CLASS 2 WIRING
12345G 6
111213 14 15 G1617181920G
100-240V 0.5A, 50-60Hz
78910G
XPA 2001-70V
ATTENUATION HPF
10 12
8 6
14
LIMITER/PROTECT
18
4 2
26
SIGNAL
0
1234
RS-232
TxRx G
REMOTE AT
EXP
RS-232
SIG LINK
POWER 12V
0.7A MAX
XTP IN
-+
100-240V 0.5A, 50-60Hz
REMOTE
INPUTS
70 V OUTPUT
10V
50mA
L (SUMMED)
R
G
STANDBY
80 Hz
OFF
GCV
CLASS 2 WIRING
Extron DMP 128 C AT
Digital Matrix
RESET
LAN
Processor
OVER XTP
RS-232 IR
RxTx
RxGTx
LAN
XPA 2001-70V
ATTENUATION HPF
10
12
8
14
LIMITER/PROTECT
18 26
SIGNAL
0
RELAYS
OUTPUTS
AUDIO
AUDIO
1
RL
ON
OFF
-+-+
HDMI
S/PDIF
Extron XTP R HDMI
Receiver
POWER 12V
0.7A MAX
-+
100-240V 0.5A, 50-60Hz
REMOTE
INPUTS
70 V OUTPUT
10V
50mA
L (SUMMED)
R
6
G
STANDBY
80 Hz 4 2
OFF
GCV
CLASS 2 WIRING
2
XTP R HDMI
RESET
RS-232
SIG LINK
XTP IN
XPA 2001-70V
LIMITER/PROTECT
SIGNAL
OVER XTP
RS-232 IR
RxGTx
LAN
REMOTE
INPUTS
ATTENUATION HPF
10V
L (SUMMED)
R
10 12
8 6
14
80 Hz
18
4 2
26
OFF
0
Projector
OUTPUTS
AUDIO
AUDIO
RL
ON
OFF
-+-+
HDMI
RxTx
S/PDIF
Extron XTP R HDMI
Receiver
100-240V 0.5A, 50-60Hz
XPA 2001-70V
70 V OUTPUT
50mA
G
STANDBY
LIMITER/PROTECT
SIGNAL
GCV
CLASS 2 WIRING
XTP R HDMI
RELAYS
1
2
RESET
REMOTE
INPUTS
70 V OUTPUT
ATTENUATION HPF
10V
50mA
L (SUMMED)
R
10 12
8 6
14
G
STANDBY
80 Hz
18
4 2
26
OFF
0
GCV
CLASS 2 WIRING
Figure 1. Typical Application Diagram
CCI Pro 700 TouchLink Pro Conference Room Control Interface • Introduction 2
Loading...
+ 23 hidden pages