0GU3030
2007.5
®
Wall Spout
TS170E
RENESSE
™
Installation and Owner’s Manual
English
Español
Français
Contents
Important Safeguards---------------1
Specifications -------------------------2
Before Installation--------------------2
Set-Up Drawing -----------------------3
Components ---------------------------3
Installation Procedure -------------4
Shower Setup -------------------------5
Maintenance --------------------------5
Troubleshooting ---------------------6
Replacement Parts-------------------6
Warranty---------------------------------7
Thank you for your recent purchase
•
of the TOTO® product. Please read the
enclosed information to ensure the
safe use of your product.
.
Important Safeguards
(For your safety please follow the instructions below)
Read the “ Important Safeguards” section throughly before installing the product.
●Following symbols indicate safe and proper use of the product. Failure to observe them may
result in injury or property damage. The symbols and their meanings are as follows.
●The following table demonstrates the use of safety symbols in this manual.
ENGLISH
Do Not
Caution
Do not connect the pipe adapter (please refer to Page #7) with
spout before attaching it to the water supply pipes.
Failure to observe this
symbol may result in
injury or property damage
Absolutely Do NOT.
Do not disassemble
Mandatory!
Caution
Failure to observe this caution may result in scratches on the spout
or looseness of setscrew.
Do not cause scratches to the O-ring.
Damaged O-ring may cause water leakage.
Do not disassemble or modify the product in anyway not
described in this manual.
Do not
disassemble
Careless disassembly or modification may result in the product failure.
Mount the wall spout firmly so that it may not be loose or
detached while using.
Loose setscrews will make mounting unstable, resulting in injuries.
Mandatory
Handle the threaded portion of showerhead with care.
You may hurt your fingers.
Apply pipe selaing tape to threads.
Failure to observe this caution may result in water leakage.
1
Specification
Water Supply
Pressure
Supplied Water Temperature
Water Quality
Ambient Temperature
Water Supply Connection
Humidity
Flow Rate
Depending on the model, some specifications may differ.
Minimum pressure
Maximum pressure
Before installation
20 psi (0.14MPa) (flowing pressure)
125 psi (0.86MPa) (static) Check local building code
Less than 185°F (85°C)
Water that meets National/Primary drinking water regulation
34 -104°F (2 - 40°C)
1/2” NPT
Maximum 90% RH
Max. 2.5 gallons per minutes (9.5L/min)
▪ Observe all local plumbing codes.
▪ Make sure water supply is shut off.
▪ Read these instructions carefully to ensure proper installation.
▪ Check to make sure you have the following parts indicated below.
● If the water supply pressure is higher than 125psi (0.86MPa), you should buy a
reducing valve to reduce the pressure to the range of 0.2-0.3MPa.
To use the faucet comfortably, the recommended pressure is about 30-45 psi
(0.2-0.3MPa).
●To prevent being scalded due to malfunction, the cold water supply pressure must
be higher than the hot water pressure, or you can make them equal. In addition,
if you increase the pressure of the hot water, it still must be lower than that of cold
water supply side.
●To prevent being scalded due to wrong operation, it is recommended the hot water
supply temperature is 140°F (60°C).
●For ease of water flow adjustment and inspection with tools, you should prepare an
extra stop valve.